• 제목/요약/키워드: Capture Device

검색결과 166건 처리시간 0.024초

An Evaluation for Predicting the Far Wake of Tidal Turbines

  • 양창조;황안둥
    • 한국마린엔지니어링학회:학술대회논문집
    • /
    • 한국마린엔지니어링학회 2012년도 전기공동학술대회 논문집
    • /
    • pp.155-156
    • /
    • 2012
  • In the modern age, as man's demand of energy is continuously grew, tidal becomes one of the sustainable energy sources that have been investigating thoroughly recently. Tidal turbine has proved high potential as a future power-generating device. To effectively capture tidal energy on site, a group of tidal turbines should be used and positioned in some formation with proper size and space so that energy can be absorbed from multiple point. Thus, the turbines together with the flow filed becomes a huge domain, a tidal farm. So, it becomes more convenient if a whole turbine farm is simulated by means of actuator discs since the time and cost for analysis can be reduced. This paper aims to evaluate the operating performance (power efficiency and energy restoration rate), mutual influence (for different longitudinal and lateral spaces), the influence of velocity profiles, turbulence intensity and the far wake characteristic of tidal turbines operating in farm formation. The results of this study help contributing to the present development of tidal turbine as the future potential energy conversion machinery.

  • PDF

균형조절치료가 뇌활성도에 미치는 영향 (The Effect of Balance Control Therapy on Brain Activation)

  • 오영택;한동욱
    • 대한물리의학회지
    • /
    • 제8권2호
    • /
    • pp.163-173
    • /
    • 2013
  • PURPOSE: This study determined the effect of balance control therapy in the brain activation. METHODS: Twenty-two college students who showed decrease of muscle strength in O-ring test were as participants in this study. And the subjects were randomly divided into experimental group (n=13) and control group (n=9). Measurement device is portable EEG (Nihonkhoden, Japan). Examinations used twenty electrodes attached to the head to capture electrical brain signals during 5 minutes with brain activated states such as the awaked state and the data were compared between the two groups. RESULTS: After treatment by balance control therapy, P3 (p<.025) and P4 areas (p<.025) showed a significantly lower ST index in the experimental group than the control group, The variation of ST index in P4 area (p<.025) was decreased in the experimental group but was increased in the control group. CONCLUSION: These results showed that the balance control therapy was helpful to change the brain activation such as the stress (ST) index at the sensory area in the college students.

몬테칼로 시뮬레이션을 활용한 양성자가속기 단기사용 시 구성품의 방사화 평가 (A Study on the Radioactive Products of Components in Proton Accelerator on Short Term Usage Using Computed Simulation)

  • 배상일;김정훈
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제43권5호
    • /
    • pp.389-395
    • /
    • 2020
  • The evaluation of radioactivated components of heavy-ion accelerator facilities affects the safety of radiation management and the exposure dose for workers. and this is an important issue when predicting the disposal cost of waste during maintenance and dismantling of accelerator facilities. In this study, the FLUKA code was used to simulate the proton treatment device nozzle and classify the radio-nuclides and total radioactivity generated by each component over a short period of time. The source term was evaluated using NIST reference beam data, and the neutron flux generated for each component was calculated using the evaluated beam data. Radioactive isotopes caused by generated neutrons were compared and evaluated using nuclide information from the International Radiation Protection Association and the Korea Radioisotope association. Most of the nuclides produced form of beta rays and electron capture, and short-lived nuclides dominated. However, In the case of 54Mn, which is a radioactive product of iron, the effect of gamma rays should be considered. In the case of tritium generated from a material with a low atomic number, it is considered that handling care should be taken due to its long half-life.

Effects of Motor Imagery Practice in Conjunction with Repetitive Transcranial Magnetic Stimulation on Stroke Patients

  • Ji, Sang-Goo;Cha, Hyun-Gyu;Kim, Ki-Jong;Kim, Myoung-Kwon
    • Journal of Magnetics
    • /
    • 제19권2호
    • /
    • pp.181-184
    • /
    • 2014
  • The aim of the present study was to examine whether motor imagery (MI) practice in conjunction with repetitive transcranial magnetic stimulation (rTMS) applied to stroke patients could improve theirgait ability. This study was conducted with 29 subjects diagnosed with hemiparesis due to stroke.The experimental group consisted of 15 members who were performed MI practice in conjunction with repetitive transcranial magnetic stimulation, while the control group consisted of 14 members who were performed MI practice and sham therapy. Both groups received traditional physical therapy for 30 minutes a day, 5 days a week, for 6 weeks; additionally, they received mental practice for 15 minutes. The experimental group was instructed to perform rTMS and the control group was instructed to apply sham stimulation for 15 minutes. Gait analysis was performed using a three-dimensional motion capture system, which is a real-time tracking device that delivers data via infrared reflective markers using six cameras. Results showed that the velocity, step length, and cadence of both groups were significantly improved after the practice (p<0.05). Significant differences were found between the groups in velocity and cadence (p<0.05) as well as with respect to the change rate (p<0.05) after practice. The results showed that MI practice in conjunction with rTMS is more effective in improving gait ability than MI practice alone.

Acquisition Model for 3D Shape Measurement Data

  • Park, Jong-Sik;Jang, Wang-Jin;Lee, Seong-Beom;Park, Chan-Seok
    • International Journal of Precision Engineering and Manufacturing
    • /
    • 제9권4호
    • /
    • pp.16-21
    • /
    • 2008
  • The demand for three-dimensional (3D) shape measurements is increasing in a variety of fields, including the manufacture of molds and dies. The most popular technology for 3D shape measurement is the coordinate measuring machine (CMM) with a contact trigger probe. Although a CMM provides a high degree of accuracy, it is inefficient due to its long measuring time. It also has difficulty measuring soft objects that can be deformed by the touch of the contact probe. In addition, a CMM cannot digitize areas that are difficult to reach, and cannot capture very minute details on the surface of complex parts. For these reasons, optical non-contact measurement techniques are receiving more attention since they eliminate most of the problems associated with contact methods. Laser scanning is emerging as one of the more promising non-contact measurement techniques. This paper describes various acquisition considerations for laser scanning, including the accuracy of the 3D scan data, which depends on the charge-coupled device (CCD) gain and noise. The CCD gain and noise of a 3D laser scanner are varied while keeping the other conditions constant, and the measurement results are compared to the dimensions of a standard model. The experimental results show that a considerable time savings and an optimum degree of accuracy are possible by selecting the proper CCD gain and noise.

내시경 수술시스템의 주변장치 개발 (Development of Peripheral Devices on the Endoscopic Surgery System)

  • 이영묵;송철규;이상민;김원기
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1995년도 춘계학술대회
    • /
    • pp.164-166
    • /
    • 1995
  • The objectives of study are to develop a peripheral device on the endoscopic surgery system. These systems are consist of the following units. They are a color monitor of high resolution, light source, computer system and endoscopic camera with a C-mount head, irrigator, color video printer, Super VHS recorder and a system rack. The color monitor is a NTSC monitor for monitoring the image projected of the surgical section. The lightsource is necessary to irradiate the interior of a body via an optic fiber, The light projector will adapt the brightness in accordance with changing distance from the object. A miniature camera using a color CCD chip and computer system is used to capture and control an image of the surgical section[1]. The video printer is a 300 DPI resolution using thermal sublimation methods, which is developed by Samsung Electronics Co., Ltd. The specification of the endoscopic data management system is consist of storage of a captured image and pathological database of patients [2-4].

  • PDF

선택적 암호화가 가능한 윈도우 미디어 보호 방법 (Protection of Windows Media Video Providing Selective Encryption)

  • 박지현;류재철
    • 정보처리학회논문지B
    • /
    • 제16B권2호
    • /
    • pp.101-108
    • /
    • 2009
  • IP 셋톱박스에 서비스되는 콘텐츠는 IP 네트워크를 통하여 전송되므로 네트워크 해킹 도구를 이용하면 스트리밍되는 콘텐츠를 저장후 불법이용이 가능하다. 따라서 안전한 스트리밍 서비스를 위해서는 스트리밍 환경에 적합한 콘텐츠 보호 방법이 요구된다. 최근까지 스트리밍 서비스되는 콘텐츠는 MPEG-2 TS를 이용하였지만, 낮은 압축률과 TS 패킷의 높은 오버헤드때문에 현재는 WMV, MPEG-4, H.264로 점차 옮겨가고 있다. 본 논문은 스트리밍되는 윈도우 미디어 콘텐츠를 보호하기 위한 DRM을 제안한다. 제안하는 방법은 기존의 WMV 스트리밍 시스템에 비의존적으로 설계되어 기존의 스트리밍 환경에 적용이 용이하고, 사용자 기기의 성능을 고려하여 DRM 처리 시간을 조절할 수 있도록 선택적 암호화 기법을 제공한다. 본 논문에서는 실험을 통하여 선택적 암호화를 이용하여 DRM 처리시간을 감소시킬 수 있음을 보인다.

발바닥굽힘근 근피로가 발목관절 고유수용성 감각을 감소시키는가? (Does Plantar-Flexor Muscle Fatigue Degrade Proprioceptive Sense at the Ankle Joint?)

  • 한진태
    • PNF and Movement
    • /
    • 제17권3호
    • /
    • pp.463-469
    • /
    • 2019
  • Purpose: This study investigated the effect of plantar-flexor muscle fatigue on the force sense and joint reposition sense of ankle joints in the healthy adults. Methods: Fifteen healthy subjects (male: 9, female: 6) participated in this study. A digital dynamometer was used to measure the force sense error while a wireless motion capture device was used to measure the joint reposition sense error. To induce plantar-flexor muscle fatigue for a dominant lower extremity, the subjects were asked to perform plantar flexion until exhaustion while barefoot. The differences in force sense error and joint reposition sense error for the ankle joint were measured immediately. The Wilcoxon test was used to compare these values before and after inducing plantar-flexor muscle fatigue. Results: The force sense error and joint reposition sense error of ankle joints after inducing plantar-flexor muscle fatigue increased significantly compared to the values before inducing muscle fatigue. Conclusion: This study suggests that plantar-flexor muscle fatigue could degrade the force sense and joint reposition sense in ankle joints. In addition, it could deteriorate ankle proprioception.

분무특성 파악을 위한 이미지 프로세싱 기법 연구 (A study on the Image processing method for the Measurements of Spray characteristics)

  • 전재형;김태영;홍문근;이수용
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2010년도 제34회 춘계학술대회논문집
    • /
    • pp.85-88
    • /
    • 2010
  • 액체 추진기관을 개발하는데 있어 분사기의 분무특성 파악은 필수적이다. 본 연구에서는 디지털 이미지 프로세싱 기법을 이용하여 Gas-Centered Swirl Coaxial(GCSC) 분사기의 분무특성들 중 분무각도, 분열길이, 액적크기를 측정하는 방법에 대하여 알아본다. 스트로보스코프와 CCD 카메라를 이용한 직접사진기법으로 분무 이미지를 저장하였고, 그 결과를 처리하기 위한 이미지 처리방법과 알고리듬의 검토가 이루어졌다. 이 방법이 아직 확실한 검증이 필요하고 한계성을 지니지만, 분사기 개발에 정확하고 더 많은 데이터를 제공할 수 있기를 기대한다.

  • PDF

PC기반 실시간 소프트웨어 GPS 수신기 설계 (Design of a PC based Real-Time Software GPS Receiver)

  • 고선준;원종훈;이자성
    • 대한전기학회논문지:시스템및제어부문D
    • /
    • 제55권6호
    • /
    • pp.286-295
    • /
    • 2006
  • This paper presents a design of a real-time software GPS receiver which runs on a PC. The software GPS receiver has advantages over conventional hardware based receivers in terms of flexibility and efficiency in application oriented system design and modification. In odor to reduce the processing time of the software operations in the receiver, a shared memory structure is used with a dynamic data control, and the byte-type IF data is processed through an Open Multi-Processing technique in the mixer and integrator which requires the most computational load. A high speed data acquisition device is used to capture the incoming high-rate IF signals. The FFT-IFFT correlation technique is used for initial acquisition and FLL assisted PLL is used for carrier tracking. All software modules are operated in sequence and are synchronized with pre-defined time scheduling. The performance of the designed software GPS receiver is evaluated by running it in real-time using the real GPS signals.