• 제목/요약/키워드: Capsule Endoscope

검색결과 40건 처리시간 0.034초

전기 자극 강도에 따른 소장 내부에서의 수축력 관계 (Relationship between electrical stimulus strength and contraction force from the inside of small intestine)

  • 우상효;김태완;이정현;박희준;문연관;원철호;이승하;박일용;조진호
    • 센서학회지
    • /
    • 제17권1호
    • /
    • pp.1-8
    • /
    • 2008
  • Recently, capsule endoscope was developed to observe small intestine in human body. However, the capsule does not have any locomotive ability, which reduces the benefit of the capsule endoscope. Many researches have done to give locomotion to the capsule, still it consumes too much power to generate the motion by small battery. One of the moving method is electrical stimulus that consumes less power than many methods. The electrical stimulus method causes contraction in the small intestine, and it moves the capsule. Some of papers showed it is possible to guide the capsule by electrical stimulus, however the relationship between electrical stimulus at the mucous and contraction force in the small intestine is not reported, yet. In this paper, the mucous in the small intestine was stimulated, and measured the contraction force in the small intestine is shown. The result shows, the relationship between electrical stimulus parameters (voltage, duration) and contraction force. Also, equation between electrical stimulus parameters and contraction force is roughly induced.

각변위 방식을 이용한 캡슐의 오리엔테이션 측정 방법 (Orientation Tracking Method based on Angular Displacement for Wireless Capsule Endoscope)

  • 유영선;김명유;유영갑
    • 한국콘텐츠학회논문지
    • /
    • 제8권2호
    • /
    • pp.27-32
    • /
    • 2008
  • 본 논문은 각변위 방식을 이용한 소화경로 모델링 및 경로에 대한 캡슐의 오리엔테이션 측정 방법을 제안하였다. 제안하는 방법은 캡슐 내시경의 자세를 3차원 방향벡터와 이의 회전성분으로 표현하였다. 소화경로에 대한 캡슐의 오리엔테이션 정보인 롤, 피치 그리고 요우 값은 각각 $1.6^{\circ}$ 이내의 오차를 보였다. 제안된 방법은 자기장을 이용한 오리엔테이션 측정에서 롤값 측정 문제를 해결하였다. 오일러 각을 이용한 기존의 오리엔테이션 측정 방식과 비교하여 알고리즘의 복잡도를 줄였다.

초음파 거리를 이용한 캡슐 내시경의 위치 및 자세각 추정 (Position and Attitude Estimation of a Capsule Endoscope based on Ultrasonic Ranging)

  • 김은정;김명유;김덕기;김용대;유영갑
    • 전자공학회논문지SC
    • /
    • 제44권5호
    • /
    • pp.38-44
    • /
    • 2007
  • 본 논문은 초음파 거리를 이용하여 캡슐 내시경의 3차원 위치 측정 방법과 자세각을 측정하는 방법을 제시하였다. 인체의 불규칙한 초음파 전달 특성들에 의해 발생되는 측정 에러를 줄이기 위해서 제안된 트랙킹 시스템은 초음파센서들을 사용하였다. 캡슐 내시경과 바인더 시스템까지의 거리 정보를 이용하여 캡슐 내시경의 3-D 위치 정보와 자세 정보를 추적하는 방법을 제안한다. 제안된 방법은 Matlab으로 랜덤 오차를 포함하여 시뮬레이션 하였다. 3-D 위치 측정 결과는 평균오차 0.8mm, 자세 측정 결과는 평균 오차 $0.2^{\circ}$의 결과를 얻었다. 캡슐 내시경의 위치 정보와 자세 정보를 이용하여 의사들이 정확한 발병 위치를 진단 할 수 있도록 하였다.

캡슐 내시경 시스템의 최신 의료 영상처리 및 진단 기술 (Recent Advances in Medical Image Processing and Diagnosis Technology for Capsule Endoscope Systems)

  • 김기윤;김태권
    • 한국통신학회논문지
    • /
    • 제38C권9호
    • /
    • pp.802-812
    • /
    • 2013
  • 캡슐 내시경 시스템은 최소 침습적 방법으로 의료진이 환자의 소화기관 검사를 수행할 수 있는 혁신적 기술로 최근 주목 받는 융합 기술이다. 일단 환자가 비타민 알약 크기의 캡슐을 삼키면, 캡슐 내 무선 또는 인체통신 모듈에 의해 전송된 영상정보를 바탕으로 의료진은 캡슐 내시경 진단 시스템을 통해 혈액 이상, 용종, 궤양, 크론병 등 다양한 질환을 진단할 수 있다. 캡슐 내시경은 기존의 케이블 내시경을 대신할 수 있는 혁신 기술이지만 정확한 병증 진단 및 분석 소요 시간 측면에서 단점을 가지고 있다. 즉, 캡슐 내시경은 캡슐내의 소형 카메라를 이용하여 6~12만 프레임의 방대한 양의 정지 영상을 촬영하기 때문에 촬영된 영상을 의료진이 확인하고 정확한 병변을 분석하는데 오랜 시간이 걸린다. 따라서 캡슐 내시경 시스템은 빠른 병변 진단을 위한 도구 및 정확한 병변 진단을 위한 의료 이미지 영상 처리가 필수 요소이다. 본 논문에서는 캡슐 내시경 시스템의 주요 제조사들을 중심으로 거의 알려져 있지 않은 소화기 영상의 빠른 병변 진단 도구에 대한 최근 경향과 정확한 병변 검출을 위한 의료 영상 처리 기술의 최신 동향을 분석하였다.

캡슐형 내시경을 위한 체내 이동용 마이크로 로봇 (Locomotive Microrobot for Capsule Endoscopes)

  • 양성욱;박기태;이승석;나경환;김진석;최종호;박석호;박종오;윤의성
    • 로봇학회논문지
    • /
    • 제4권1호
    • /
    • pp.62-67
    • /
    • 2009
  • For diagnoses of digestive organs, capsule endoscopes are widely used and offer valuable information without patient's discomfort. A general capsule endoscope which consists of image sensing module, telemetry module and battery is able to move along gastro-intestinal tracts passively only through peristaltic waves. Thus, it is likely to have some limitations for doctor to acquire images from the desired organs and to diagnose them effectively. As solutions to these problems, a locomotive function of capsule endoscopes has being developed. We have proposed a capsule-type microrobot with synchronized multiple legs. However, the proposed capsular microrobot also has some limitations, such as low speed in advancement, inconvenience to controlling the microrobot, lack of an image module, and deficiency in a steering module. In this paper, we will describe the limitations of the locomotive microrobot and propose solutions to the drawbacks. The solutions are applied to the capsular microrobot and evaluated by in-vitro tests. Based on the experimental results, we conclude that the proposed solutions are effective and appropriate for the locomotive microrobot to explore inside intestinal tracts.

  • PDF

다량의 내장 사진에 의한 화상 구성 (Composite Endoscope Image Construction based on Massive Inner Intestine Photos)

  • 김은정;유관희;유영갑
    • 전자공학회논문지SC
    • /
    • 제44권1호
    • /
    • pp.108-114
    • /
    • 2007
  • 본 논문은 캡슐 내시경 검사시 진단시간을 줄이기 위해 내시경에서 촬영된 다량의 사진들을 한 장의 이미지로 재구성하는 방법을 제안하였다. 모델링을 단순화하기 위해, 내장을 연속적인 3-D 원통들의 합으로 가정하였다. 제안된 방법은 캡슐 내시경으로부터 촬영된 다량의 사진들을 이용하여 한 장의 2-D 평면 이미지로 재구성한다. 재구성된 이미지를 이용하여 3-D 원통형 모델을 구현하였다. 제안된 이미지 복원 방법은 그래픽 라이브러리인 OpenGL을 사용하여 시뮬레이션 하였다. 재구성된 이미지는 2-D 평면에 전체 내장이 펼쳐진 것과 같은 영상으로 의사들이 넒은 부위의 내장을 한 번에 검사할 수 있어서 빠르게 발병 위치를 확인할 수 있다.

Chirp spread spectrum 변조를 이용한 인체 내외 통신 기법 (Human Body Communication Using Chirp Spread Spectrum Modulation)

  • 김경철;전명운;김기현;이정우;남상욱
    • 한국통신학회논문지
    • /
    • 제35권5A호
    • /
    • pp.440-446
    • /
    • 2010
  • 다양한 분야에서 IT와 BT의 융합이 논의되고 있으며 의료 산업에서 캡슐 내시경의 개발은 인체를 매개로 무선 통신을 한다는 점에서 그 예라 할 수 있을 것이다. 하지만 인체 채널에서의 통신은 송신 전력의 제한이 엄격할 수 밖에 없으며, 아직 채널 특성에 대한 활발한 연구도 이루어지지 않아서 그 채널을 추정하기가 매우 어렵다. 따라서 정확한 채널 추정이 필요한 일반적인 부호화 / 복호화 기법을 사용할 수 없으며, 기존 통신망에서 유입되는 간섭 신호에 취약할 수 밖에 없다. 본 논문에서는 채널 추정이 필요 없으면서도, 주위 간섭 신호의 영향에 강인한 Chirp Spread Spectrum Differential Binary Phase Shift Keying(CSS-DBPSK) 기법을 소개하고, Chirp Spread Spectrum On-Off Keying (CSS-OOK) 기법을 제안한다. CSS-DBPSK, CSS-OOK를 이용하면 일반 OOK에 비하여 target BER (Bit Error Rate) 10-5)을 위한 Eb/N0을 약 5dB, 2dB 낮출 수 있으며 간섭 신호에 대한 성능 저하도 막을 수 있다.

자기력을 이용한 충격형 액추에이터의 설계 및 성능 평가 (Design and Performance Evaluation of Impact Type Actuator Using Magnetic Force)

  • 민현진;임형준;김병규;김수현
    • 대한기계학회논문집A
    • /
    • 제26권7호
    • /
    • pp.1438-1445
    • /
    • 2002
  • For robotic endoscope, some researchers suggest pneumatic actuators based on inchworm motion. But, the existing endoscopes have not been replaced completely because human intestine is very sensitive and susceptible to damage. We design and test a new locomotion of robotic endoscope that allows safe maneuverability in the human intestine. The actuating mechanism is composed of two solenoids at each side and a single permanent magnet. When the current direction is reversed, repulsive force and attractive at the opposition side propels permanent magnet. Impact force against robotic endoscope transfers momentum from moving magnet to endoscope capsule. The direction and moving speed of the actuator can be controlled by adjustment of impact force. Modeling and simulation experiments are carried out to predict the performance of the actuator. Simulations show that force profile of permanent magnet is the dominant factor for the characteristic of the actuator. The results of simulations are verified by comparing with the experimental results.

영상 프레임 분석을 통한 대용량 캡슐내시경 영상의 지능형 판독보조 시스템 (Intelligent Diagnosis Assistant System of Capsule Endoscopy Video Through Analysis of Video Frames)

  • 이현규;최민국;이돈행;이상철
    • 지능정보연구
    • /
    • 제15권2호
    • /
    • pp.33-48
    • /
    • 2009
  • 캡슐내시경검사는 일반 내시경 검사에 비해 고통이 없고 합병증이 적다고 보고되어 있어 향후 지속적인 발전 가능성이 매우 큰 분야로 잘 알려져 있다. 그러나, 캡슐내시경을 이용한 진단은 캡슐이 동일한 위치에 상주할 경우 반복적으로 촬영된 유사한 영상을 오래도록 관찰 하여야 하므로, 진단자로 하여금 막대한 시간적 비용을 발생하게 한다. 따라서 보다 현실적이고 실용적인 캡슐내시경 검사를 위한 효율적인 탐색 및 진단 방법으로써 캡슐내시경영상에 대한 지능형 탐색방법이 요구된다. 본 논문에서 제안하는 지능형 판독보조 시스템은 영상차감을 통해 중복영상을 최소화한 후 프레임단위로 영상이 내포한 정보를 일차원도표(map)의 형태로 제공하고, 이러한 결과도표의 분석도구 및 방법을 제안함으로써 진단시간을 큰 폭으로 단축할 수 있는 방법을 제안하였다. 즉, 비교연산 한 정규화된 교차상관(Normalized Cross-Correlation) 방법을 통해 전처리 된 인접영상에 대한 유사도를 추출하고, 설정된 임계값이상의 영상들만을 탐색 범위로 지정하여 중복 촬영된 영상의 탐색을 최소화 한다. 이외에도 영상간 유사도, 엔트로피와 명암도를 통해 얻어진 이동도표, 특성도표와 명암도표를 분석하여 효율적으로 사용자가 탐색을 원하는 부위에 대한 탐색밀도를 높이는 등의 다양한 진단 매뉴얼을 제시한다.

  • PDF