• 제목/요약/키워드: Capsule Endoscope

검색결과 40건 처리시간 0.021초

A Paddling Based Locomotive Mechanism for Capsule Endoscopes

  • Park Suk-Ho;Park Hyun-Jun;Park Sung-Jin;Kim Byung-Kyu
    • Journal of Mechanical Science and Technology
    • /
    • 제20권7호
    • /
    • pp.1012-1018
    • /
    • 2006
  • Diagnosis and treatment using the conventional flexible endoscope in gastro-intestinal tract are very common since advanced and instrumented endoscopes allow diagnosis and treatment by introducing the human body through natural orifices. However, the operation of endoscope is very labor intensive work and gives patients some pains. As an alternative, therefore, the capsule endoscope is developed for the diagnosis of digestive organs. Although the capsule endoscope has conveniences for diagnosis, it is passively moved by the peristaltic waves of gastro-intestinal tract and thus has some limitations for doctor to get the image of the organ and to diagnose more thoroughly. As a solution of these problems, various locomotive mechanisms for capsule endoscopes are introduced. In our proposed mechanism, the capsule-type microrobot has synchronized multiple legs that are actuated by a linear actuator and two mobile cylinders inside of the capsule. For the feasibility test of the proposed microrobot, a series of in-vitro experiments using small intestine without incision were carried out. From the experimental results, our proposed microrobot can advance along the 3D curved and sloped path with the velocity of about $3.29\sim6.26mm/sec$ and $35.1\sim66.7%$ of theoretical velocity. Finally, the proposed locomotive mechanism can be not only applicable to micro capsule endoscopes but also effective to advance inside of gastro-intestinal tract.

지렁이 모사 로봇의 모델링 및 실험 검증 (Modeling and Experimental Validation of Earthworm-like Robot)

  • 박석호;김병규;권지운
    • 대한기계학회논문집A
    • /
    • 제30권3호
    • /
    • pp.287-294
    • /
    • 2006
  • In recent years, capsule endoscope is highlighted for the patient's convenience and the possibility of the application in the small intestine. However, the capsule endoscope has some limitations to get the image of the digestive organ because its movement only depends on the peristaltic motion. In order to solve these problems, locomotion of capsule endoscope is necessary. In this paper, we analyze the locomotive mechanism of earthworm-like robot proposed as locomotive device of capsule endoscope and derive the condition which can Judge the possibility of its mobility using theoretical analysis. Based on a biomechanical modeling and simulation, the critical stroke, that is minimum stroke of the earthworm-like robot to perform motion inside small intestine, is obtained. Also, this derived critical stroke can be validated by the moving test of fabricated earthworm-like robot. Consequently, it is expected that this study can supply useful information to design of earthworm-like robot for mobility of capsule endoscope.

캡슐 내시경의 기술적 특징과 동향 (Technical Characteristics and Trends of Capsule Endoscope)

  • 김기윤;원경훈;최형진
    • 한국통신학회논문지
    • /
    • 제37권4C호
    • /
    • pp.329-337
    • /
    • 2012
  • 캡슐 내시경은 인체 내부의 소화기관 병변을 조사할 수 있는 캡슐 모양의 전자장치로서 인체 내에 케이블을 삽입하는 기존 푸시 타입(push-type)내시경과는 달리 환자에게 공포와 고통을 주지 않는 시술로 인식되고 있어, 최근 환자와 의사 모두에게 큰 관심을 끌고 있다. 이 기술은 바이오 기술(BT), 정보통신 기술(IT), 나노 기술(NT) 등의 성숙과 융합으로 2000년에 들어와 처음으로 가능하게 되었으며, LED를 포함한 광학계와 이미지 센서, 통신 모듈, 파워 모듈 등으로 구성되어 있다. 캡슐 내시경은 첨단 기술의 총체로 유비쿼터스 시대에 다양한 기술 분야의 핵심 기술을 필요로 한다. 따라서 본 논문에서는 캡슐 내시경의 구성에 관해 소개하고, 현재 데이터 전송을 위해 사용되고 있는 대표적인 RF 무선 통신 방식 및 인체 통신 시스템 방식에 대해 비교하였다. 아울러 현재 상용된 캡슐 내시경의 사양을 비교 분석하고, 미래의 캡슐 내시경의 진화 방향과 기술적 도전 과제를 제시하였다.

디더 운동이 캡슐형 내시경의 마찰계수 감소에 미치는 영향 (Influence of Dither Motion on the Friction Coefficient of a Capsule-type Endoscope)

  • 홍예선;최민준
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2005년도 춘계학술대회 논문집
    • /
    • pp.1068-1073
    • /
    • 2005
  • Development of a locomotive mechanism for the capsule type endoscopes will largely enhance the ability to diagnose disease of digestive organs. In connection with it, most of the researches have focused on an installable locomotive mechanism in the capsule. In this paper, it is introduced that the movement of a capsule type endoscope in digestive organ can be manipulated by magnetic force produced outside human body. Since the magnetic force is provided by permanent magnets, no additional power supply to the capsule is required. Using a robotic manipulator for locating the external magnet, the capsule motion control system can cover the whole human digestive organs. This study is particularly concentrated on dither motion effect to improve the mobility of capsule type endoscope. It was experimentally found out that the friction coefficient between the capsule and digestive organ can be remarkably reduced by superposing yawing or rolling dither motion on the translatory motion. In this paper, the experimental results obtained while the direction, amplitude and frequency of sinusoidal dither motion were changed are reported.

  • PDF

INVESTIGATION OF ENDOSCOPE CAPSULE DESIGN ON THE FRICTIONAL RESISTANCE INSIDE THE INTESTINE

  • Baek, N.K.;Sung, I.H.;Kim, J.S.;Kim, D.E.
    • 한국윤활학회:학술대회논문집
    • /
    • 한국윤활학회 2002년도 proceedings of the second asia international conference on tribology
    • /
    • pp.367-368
    • /
    • 2002
  • The design of capsule body for self-propelled endoscope is important from the frictional resistance point of view. The capsule should be able to overcome the frictional resistance in order to move along the intestine. The motivation of this work was to gain a better understanding of the capsule body design on the frictional resistance of the capsule inside an intestine. A special experimental set-up was built to measure the frictional resistance as the capsule was being pulled inside the pig intestine specimen. Tests were performed with open and closed intestine specimens. Experimental data showed that smooth cylindrical capsule geometry resulted in the least frictional resistance. The resistance inside the closed intestine specimen was about four times higher than that of the open specimen. It is expected that the results of this work will be used to design the optimum propulsion system for the microendoscope.

  • PDF

디더운동이 캡슐형 내시경의 마찰계수 감소에 미치는 영향 (Influence of Dither Motion on the Friction Coefficient of a Capsule-type Endoscope)

  • 홍예선;최일수;김병규
    • 한국정밀공학회지
    • /
    • 제22권8호
    • /
    • pp.57-63
    • /
    • 2005
  • Development of a locomotive mechanism fer the capsule type endoscopes will largely enhance the ability to diagnose disease of digestive organs. In connection with it, most of researches have focused on an installable locomotive mechanism in the capsule. In this paper, it is introduced that the movement of a capsule type endoscope in digestive organ can be manipulated by magnetic force produced outside human body. Since the magnetic force is provided by permanent magnets, no additional power supply to the capsule is required. Using a robotic manipulator for locating the external magnet, the capsule motion control system can cover the whole human digestive organs. This study is particularly concentrated on dither motion effect to improve the mobility of capsule type endoscope. It was experimentally found out that the friction coefficient between the capsule and digestive organ can be remarkably reduced by superposing yawing or rolling dither motion on the translatory motion. In this paper, the experimental results obtained with the direction, amplitude and frequency of sinusoidal dither motion changed is reported.

자계 센서를 이용한 캡슐형 내시경의 위치 측정 (Position Detection of a Capsule-type Endoscope by Magnetic Field Sensors)

  • 박준병;강헌;홍예선
    • 한국정밀공학회지
    • /
    • 제24권6호
    • /
    • pp.66-71
    • /
    • 2007
  • Development of a locomotive mechanism for the capsule type endoscopes will largely enhance their ability to diagnose disease of digestive organs. As a part of it, there should be provided a detection device of their position in human organs for the purpose of observation and motion control. In this paper, a permanent magnet outside human body was employed to project magnetic field on a capsule type endoscope, while its position dependent flux density was measured by three hall-effect sensors which were orthogonally installed inside the capsule. In order to detect the 2-D position data of the capsule with three hall-effect sensors including the roll, pitch and yaw angle, the permanent magnet was extra translated during the measurement. In this way, the 2-D coordinates and three rotation angles of a capsule endoscope on the same motion plane with the permanent magnet could be detected. The working principle and performance test results of the capsule position detection device were introduced in this paper showing that they could be also applied to 6-DOF position detection.

PZT 구동기를 이용한 지렁이 이동방식의 캡슐형 내시경용 마이크로 로봇 (An Earthworm-Like Locomotive Mechanism for Capsule Endoscopes Using PZT Actuator)

  • 지창열;박석호;윤석진;김병규;박장현
    • 대한기계학회논문집A
    • /
    • 제30권1호
    • /
    • pp.84-89
    • /
    • 2006
  • A wireless capsule endoscope has been developed to replace the conventional endoscope. However, the commercialized capsule endoscope moves passively by peristaltic waves, which has some limitations for doctors to diagnose more thoroughly and actively. In order to solve this problem, a locomotive mechanism is proposed for wireless capsule endoscopes. Based on the tests of various actuators, a piezo actuator is selected as a micro actuator for capsule endoscope. In general, piezo actuators are known to have limited displacement with high voltage supply. In order to overcome the limitation of common piezo actuator, the impact based piezo actuator, is developed to realize long stroke up 11mm. By using the impact based piezo actuator, a prototype of an earthworm-like locomotive mechanism was developed. In addition, the proposed locomotive mechanism has engraved clamps mimicked the claw of an insect. The earthworm-like locomotive mechanism has 15 mm in diameter and 30mm under retraction stage and 41 mm under elongation stage in total length. Hollow space is allocated to comprise essential endoscope components such as a camera, a communication module, bio sensors, and a battery. For the feasibility test of proposed locomotive mechanism, a series of experiments were carried out including in-vitro tests. Based on results of the experiments, we conclude that the proposed locomotive mechanism is effective to be used for micro capsule endoscopes.

무선 캡슐내시경 조종을 위한 머리부착형 디스플레이 인터페이스 시스템의 개발 (Development of Head Mounted Display Interface System for Controlling Wireless Capsule Endoscope)

  • 황영은;손영돈
    • 대한의용생체공학회:의공학회지
    • /
    • 제43권6호
    • /
    • pp.417-423
    • /
    • 2022
  • The present study proposed a new interface system for capsule endoscopy by using head mounted display (HMD) device, which can control the orientation of the capsule endoscope with electromagnetic actuator (EMA) system. The orientation information of the HMD user was detected by the gyroscope sensor built into the device and then calculated to as an angle increment using Unity Engine compiler. The measured angle changes from the HMD were converted to the current values of the corresponding coils to be changed in the EMA system. Two experiments were designed to measure the accuracy and the intuitiveness of the HMD interface system. In the angle accuracy measurement, the capsule endoscope driven by HMD interface system showed the averaged errors of 0.68 degrees horizontally and 1.001 degrees vertically for given test angles. In the intuitiveness measurement, HMD interface system showed 1.33 times faster manipulation speed rather than the joystick interface system. In this respect, the HMD interface system for capsule endoscopy was expected to improve the overall diagnostic environment while maintaining comfort of patients and clinicians.

캡슐형 내시경 개발을 위한 소장 내에서의 캡슐저항력 특성 (Tribological Characteristics of Endoscope Capsule Inside of Small Intestine)

  • 백남국;김대은
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2002년도 춘계학술대회 논문집
    • /
    • pp.142-145
    • /
    • 2002
  • In order to develop a self-propelled microendoscope, the frictional resistance of the capsule-type endoscope inside the intestine should be understood. In this work the frictional resistance behaviors of capsules with different designs were experimentally investigated using a pig intestine. It was found that cylindrical capsule design had the least frictional resistance. Also, the resistance increased as the speed of the capsule motion was decreased. It is expected that the results of this work will be used to design the optimum propulsion system for the microendoscope.

  • PDF