Influence of Dither Motion on the Friction Coefficient of a Capsule-type Endoscope

디더운동이 캡슐형 내시경의 마찰계수 감소에 미치는 영향

  • 홍예선 (한국항공대학교 항공우주및기계공학부) ;
  • 최일수 (한국항공대학교 대학원 항공우주및기계공학과) ;
  • 김병규 (한국과학기술연구원 마이크로시스템 센터)
  • Published : 2005.08.01

Abstract

Development of a locomotive mechanism fer the capsule type endoscopes will largely enhance the ability to diagnose disease of digestive organs. In connection with it, most of researches have focused on an installable locomotive mechanism in the capsule. In this paper, it is introduced that the movement of a capsule type endoscope in digestive organ can be manipulated by magnetic force produced outside human body. Since the magnetic force is provided by permanent magnets, no additional power supply to the capsule is required. Using a robotic manipulator for locating the external magnet, the capsule motion control system can cover the whole human digestive organs. This study is particularly concentrated on dither motion effect to improve the mobility of capsule type endoscope. It was experimentally found out that the friction coefficient between the capsule and digestive organ can be remarkably reduced by superposing yawing or rolling dither motion on the translatory motion. In this paper, the experimental results obtained with the direction, amplitude and frequency of sinusoidal dither motion changed is reported.

Keywords

References

  1. Kim, B., Lee, S., Park, J. H., Park, J. O., 'Inchworm-like Micro robot for Capsule Endoscope,' Proceedings of IEEE International Conference on Robotics & Biomimetics, 2004
  2. Dario, P., Stefanini, C. and Menciassi, A., 'Modeling and Experiments on a Legged Microrobot Locomoting in a Tubular, Compliant and Slippery Environment,' 9th International Symposium on Experimental Robot, 2004
  3. Lim, Y. M., Park, J. S., Kim, B. K., Park, J. O., Kim, S. H., 'Experimental Study on the Movement of Pneumatic Actuating Mechanism for Self-Propelling Endoscope,' J. of the KSPE Vol. 8, No. 10, pp. 194-199, 2001
  4. NORIKA -www.rfnorika.com
  5. Sendoh, M., Ishiyama, K., Arai, K.I., 'Fabrication of Magnetic Actuator for Use in a Capsule Endoscope,' IEEE Transactions on Magnetics, Vol. 39,No. 5, 2003 https://doi.org/10.1109/TMAG.2003.816731
  6. Sendoh, M., Ishiyama, K., Arai, K.I., ' Fabrication of Magnetic Actuator for Use in Colon Endoscope,' IEEE International Symposium on Micromechatronics & Human Science, 2003
  7. Baek, N. K., Sung, I. H. and Kim, D. E., 'Frictional Resistance Characteristics of a Capsule Inside the Intestine for Micro-endoscope Design,' Journal of Engineering in Medicine, 2003
  8. Baek, N. K., Kim, D. E., 'Tribological Characteristics of Endoscope Capsule Inside of Small Intestine,' Proc. of the KSPE, pp. 142-145, 2002