• Title/Summary/Keyword: Capillary flow

Search Result 386, Processing Time 0.022 seconds

Tc-99m DPD 골스캔과 복부 CT 영상에서 보이는 위암의 석회화 (Visualization of the Gastric Calcification due to Cancer on Tc-99m DPD and Abdominal CT Images)

  • 정영진;강도영
    • 대한핵의학회지
    • /
    • 제38권5호
    • /
    • pp.344-346
    • /
    • 2004
  • A 69-year-old woman was presented with progressed dysphagia, gastric soreness and weight loss during 2 months. She was performed abdomen x-ray, EGDS and abdomen CT. Abdomen x-ray demonstrated punctuate calcification on LUQ. EGDS showed an ulceroinfiltrative mass with bleeding on cardia to antrum of stomach. And CT showed diffuse gastric wall thickness with multiple calcifications. Biopsy of the stomach and esophagus during EGDS examination revealed an adenocarcinoma, with signet ring cell type, infiltrating the wall of the stomach and the distal esophagus. Then acne scan was performed a few days later. It revealed intense uptake in LUQ, corresponding to the calcium containing neoplasm seen on the abdomen x-ray, EGDS and abdomen CT. And there was no evidence of any metastatic lesion and thyroid uptake on the bone scan. There are many reports about accumulation of the tracer in extraosseous lesion, but only a few literatures were reported about gastric calcification in stomach cancer. More over, no reports showed CT images. We are performed many diagnostic examinations and found well correlation between them. The reason of gastric calcification is considered with calcium deposition within extracellular space due to hemorrhage or necrosis. Other possibility offered to explain gastric calcification have been increased blood flow and/or increased neovascularity with capillary leaks of tracer, and specific enzymatic (phosphatases) receptor binding of tracer. So, it was happened ion exchange between intracellular calcium and phosphate groups of tracer.

확장표면을 적용한 액체식 제습기에서 제습액 분배 특성에 관한 실험적 연구 (Experimental Study on Liquid Desiccant Distribution Characteristics at a Dehumidifier with Extended Surface)

  • 이민수;장영수;이대영
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.645-649
    • /
    • 2009
  • Liquid desiccant cooling technology can supply cooling by using waste heat and solar heat which are hard to use effectively. For compact and efficient design of a dehumidifier, it is important to sustain sufficient heat and mass transfer surface area for water vapor diffusion from air to liquid desiccant on heat exchanger. In this study, the plate type heat exchanger is adopted which has extended surface, and hydrophilic coating and porous layer coating are adopted to enhance surface wettedness. PP(polypropylene) plate is coated by porous layer and PET(polyethylene terephthalate) non-woven fabric is coated by hydrophilic polymer. These coated surfaces have porous structure, so that falling liquid film spreads widely on the coated surface foaming thin liquid film by capillary force. The temperature of liquid desiccant increases during dehumidification process by latent heat absorption, which leads to loss of dehumidification capacity. Liquid desiccant is cooled by cooling water flowing in plate heat exchanger. On the plate side, the liquid desiccant can be cooled by internal cooling. However the liquid desiccant on extended surface should be moved and cooled at heat exchanger surface. Optimal mixing and distribution of liquid desiccant between extended surface and plate heat exchanger surface is essential design parameter. The experiment has been conducted to verify effective surface treatment and distribution characteristics by measuring wall side flow rate and visualization test. It is observed that hydrophilic and porous layer coating have excellent wettedness, and the distribution can be regulated by adopting holes on extended surface.

  • PDF

Gas Chromatography-Nitrogen Phosphorous Selective Detection을 이용한 혈장중 Haloperidol 및 대사체인 Reduced Haloperidol의 동시정량 (Simultaneous Determination of Haloperidol and Its Metabolite, Reduced Haloperidol, in Plasma by Gas Chromatography Using Nitrogen Phosphorous Selective Detection)

  • 박경호;이민화;심창구;이명걸;박종세
    • Journal of Pharmaceutical Investigation
    • /
    • 제22권3호
    • /
    • pp.197-204
    • /
    • 1992
  • A gas chromatographic method using nitrogen phosphorous selective detection was developed for simultaneous determination of haloperidol and its metabolite, reduced haloperidol, in human plasma. Combelen was used as internal standard, The method involved extraction and trimethylsilylation followed by the injection of $2-4\;{\mu}l$ of benzene layer, which was used to dissolve the trimethylsilylated derivatives of haloperidol and reduced haloperidol, onto SE-54 column [5% phenyl methyl silica fused capillary column, $16m{\times}0.22\;mm$ $(I.D.){\times}0.33\;{\mu}m$ (coated thickness)]. The temperature of column oven was programmed from $200^{\circ}C\;to\;300^{\circ}C$ at the increase rate of $10^{\circ}C/min and also the temperatures of injector and detector were set at $300^{\circ}C$. Helium was used as carrier gas and its flow rate was maintained at 30 ml/min. The detection was conducted with nitrogen phosphorous selective detector. The retention times for combelen, reduced haloperidol and haloperidol were found to be 9.14, 9.75 and 9.99 min, respectively. The detection limits for haloperidol and reduced haloperidol in human plasma were both 0.2 ng/ml. The coefficients of variation of the intra-assay were generally low (below 9.8%). The mean absolute recoveries of added haloperidol and reduced haloperidol from plasma were 72% and 84%, respectively. No interferences from endogenous substances were found.

  • PDF

Solderable 이방성 도전성 접착제를 이용한 BGA 접합공정 개발 (Development of BGA Interconnection Process Using Solderable Anisotropic Conductive Adhesives)

  • 임병승;이정일;오승훈;채종이;황민섭;김종민
    • 반도체디스플레이기술학회지
    • /
    • 제15권4호
    • /
    • pp.10-15
    • /
    • 2016
  • In this paper, novel ball grid array (BGA) interconnection process using solderable anisotropic conductive adhesives (SACAs) with low-melting-point alloy (LMPA) fillers have been developed to enhance the processability in the conventional capillary underfill technique and to overcome the limitations in the no-flow underfill technique. To confirm the feasibility of the proposed technique, BGA interconnection test was performed using two types of SACA with different LMPA concentration (0 and 4 vol%). After the interconnection process, the interconnection characteristics such as morphology of conduction path and electrical properties of BGA assemblies were inspected and compared. The results indicated that BGA assemblies using SACA without LMPA fillers showed weak conduction path formation such as solder bump loss or short circuit formation because of the expansion of air bubbles within the interconnection area due to the relatively high reflow peak temperature. Meanwhile, assemblies using SACA with 4 vol% LMPAs showed stable metallurgical interconnection formation and electrical resistance due to the favorable selective wetting behavior of molten LMPAs for the solder bump and Cu metallization.

Micromorphological Features of Pan Horizon in the Soils Derived from Different Parent Materials

  • Zhang, Yongseon;Sonn, Yeon-Kyu;Moon, Yong-Hee;Jung, Kangho;Cho, Hye-Rae;Han, Kyeong-Hwa
    • 한국토양비료학회지
    • /
    • 제47권4호
    • /
    • pp.242-248
    • /
    • 2014
  • We have five soil series of pan soils in South Korea out of 391 series: Gangreung, Bugog, Yeongog, Jangweon, and Pogog. Productivity decreases in pan soils as pan horizons impede percolation and capillary rise of water and interrupt root extension. This study was performed to investigate pedogenic processes of pan soils mainly located in footslope and river terrace by analyzing physicochemical properties and soil micro-morphology. Korean pan soils belong to Alfisols, Ultisols, or Inceptisols and have udic or aquic soil moisture regime, mesic temperature regime, and mixed mineral substances. Texture of pan horizons selected for the present study was mainly silty clay loam with clay contents ranging from 26.3 to 45.3%. Bulk density of the pan horizons ranged from 1.4 to $2.1Mg\;m^{-3}$ and their soil structure were subangular or angular structure. In terms of micro-morphological structure, Bt horizon of Gangreung series was formed as platy and striated b-fabric structure possibly affected by uplift of coastal terrace following clay sedimentation by flood. Jangweon series showed micro-morphology of massive structure and crystallic b-fabric as macropores between coarse debris established by debris fall in slope were filled with silt-sized particles. The Bt horizons having massive structure and striated b-fabric in Yeongog, Pogog, and Bugog series implies that those horizons experienced horizontal mass flow after clay accumulation.

뿜칠 방수 멤브레인이 시공된 터널 라이닝의 수분이동에 관한 수치해석 연구 (A Numerical study on the Moisture Transport of Concrete Tunnel Linings with the Sprayable Waterproofing Membrane)

  • 이철호;최순욱;강태호;장수호
    • 터널과지하공간
    • /
    • 제26권3호
    • /
    • pp.212-219
    • /
    • 2016
  • 뿜칠 방수 멤브레인은 숏크리트 사이에 시공되어 라이닝 크랙을 통한 누수를 방지하는 목적으로 최근 유럽 국가를 중심으로 시공 사례가 늘어가고 있다. 뿜칠 방수 멤브레인은 방수 시트에 비해 복잡한 단면에도 시공이 용이하기 때문에 이용 사례가 늘어갈 것으로 전망된다. 뿜칠 방수 멤브레인은 폴리머로 구성된 재료로서 투수성이 매우 낮지만 수분의 이동에 의해 포화가 되고 이로인해 콘크리트 재료에 간극수압이나 동결 문제를 일으킬 수 있는 우려가 있다. 본 연구에서는 뿜칠 방수 멤브레인의 수분이동과 계절변화를 고려하여 숏크리트 라이닝의 열-습도 전달 장기 해석을 수행하였다. 해석을 통해 뿜칠 방수 멤브레인의 수분 흡수 작용과 수분 이동으로 인한 상대습도 변화를 고찰할 수 있었으며 이로 인한 장기적 변화를 모사할 수 있었다.

Staphylococcus aureus 신속 검출을 위한 효소면역측정 스트립 센서 (Enzyme-linked Immunosorbent Assay Strip Sensor for Rapid Detection of Staphylococcus aureus)

  • 박소정;김영기
    • 공업화학
    • /
    • 제22권5호
    • /
    • pp.522-525
    • /
    • 2011
  • 본 연구에서는, enzyme-linked immunosorbent assay (ELISA)와 면역크로마토그래픽 기법을 결합하여 Staphylococcus aureus 검출을 위한 면역스트립을 제작하였다. 면역스트립은 4개의 서로 다른 기능을 가진 멤브레인을 이용하여 만들어졌다. 니트로셀룰로오스 멤브레인은 항체와의 결합력이 높기 때문에, 포획항체를 고정화하였고, 다공성 멤브레인들을 통하여 모세관 현상으로 인해 시료흐름을 유도하였다. 효소반응에 의해 생성된 발색신호는 디지털카메라와 자체 제작된 소프트웨어를 이용하여 정성, 정량분석 하였다. 최적의 분석조건 하에서 30 min 이내에 $2.7{\times}10^4{\sim}2.7{\times}10^7CFU/mL$ 범위의 S. aureus 농도를 측정할 수 있었다.

Clinical assessment and management of auricular arteriovenous malformation: retrospective study

  • Kim, Do Gon;Cho, Hyun Geun;Ryu, Jeong Yeop;Lee, Joon Seok;Lee, Seok Jong;Lee, Jong Min;Lee, Sang Yub;Huh, Seung;Kim, Ji Yoon;Chung, Ho Yun
    • 대한두개안면성형외과학회지
    • /
    • 제22권3호
    • /
    • pp.141-147
    • /
    • 2021
  • Background: Arteriovenous malformation (AVM) which is a high-blood-flow lesion with connections between arteries and veins without an intervening capillary bed, is difficult to manage. The ear is the second most common site of extracranial AVM. However, studies regarding the management of this condition remain lacking. The purpose of this study was to share managing experiences in our center and to investigate the treatment effect through a retrospective analysis of cases. Methods: Among 265 patients with AVM treated in our vascular anomalies center between January 2008 and January 2021, 10 patients with auricular AVM were included in the study to investigate the lesion distribution, clinical stage, and treatment methods by performing a retrospective evaluation. Results: Among 10 patients, five patients had AVMs distributed in the upper half of the ear, one patient in the lower half of the ear, and four patients in whole ear, respectively. Seven patients had Schobinger stage II, and three had stage III. One patient received surgical treatment only, four patients received sclerotherapy only, and five patients received both surgical treatment and sclerotherapy. The posttreatment status was checked as controlled in two patients, improved in seven patients, persistent in one patient. There were no worsening patients. Conclusion: Auricular AVM is a disease that is difficult to manage by one specific department, thus requiring a collaborative management effort from multidisciplinary team.

BOTANI: High-fidelity multiphysics model for boron chemistry in CRUD deposits

  • Seo, Seungjin;Park, Byunggi;Kim, Sung Joong;Shin, Ho Cheol;Lee, Seo Jeong;Lee, Minho;Choi, Sungyeol
    • Nuclear Engineering and Technology
    • /
    • 제53권5호
    • /
    • pp.1676-1685
    • /
    • 2021
  • We develop a new high-fidelity multiphysics model to simulate boron chemistry in the porous Chalk River Unidentified Deposit (CRUD) deposits. Heat transfer, capillary flow, solute transport, and chemical reactions are fully coupled. The evaporation of coolant in the deposits is included in governing equations modified by the volume-averaged assumption of wick boiling. The axial offset anomaly (AOA) of the Seabrook nuclear power plant is simulated. The new model reasonably predicts the distributions of temperature, pressure, velocity, volumetric boiling heat density, and chemical concentrations. In the thicker CRUD regions, 60% of the total heat is removed by evaporative heat transfer, causing boron species accumulation. The new model successfully shows the quantitative effect of coolant evaporation on the local distributions of boron. The total amount of boron in the CRUD layer increases by a factor of 1.21 when an evaporation-driven increase of soluble and precipitated boron concentrations is reflected. In addition, the concentrations of B(OH)3 and LiBO2 are estimated according to various conditions such as different CRUD thickness and porosity. At the end of the cycle in the AOA case, the total mass of boron incorporated in CRUD deposits of a reference single fuel rod is estimated to be about 0.5 mg.

색전술에 의한 안면부 동정맥 기형의 치료 : 증례 보고 (Treatment of Facial Arteriovenous Malformations by Embolization: A Case Report)

  • 김정연;임현수;남옥형;이효설;최성철;김미선
    • 대한소아치과학회지
    • /
    • 제49권2호
    • /
    • pp.228-233
    • /
    • 2022
  • 동정맥 기형(Arteriovenous malformations, AVMs)은 동맥과 정맥이 직접적으로 연결되어 모세혈관과 연결되지 않은 희귀한 선천성 기형 중 하나이다. AVM은 유아기 후반이나 소아기까지는 임상적으로 나타나지 않을 수 있다. 특히 안면 AVM은 생명을 위협하는 치과적 응급 상황을 일으킬 수 있다. 전신병력이 없는 만 5세 여아가 하악 좌측 제2유구치의 후방 치은 주위의 자발적인 잇몸 출혈로 내원하였다. 감별진단 및 치료를 위해 전신마취 하에 대퇴정맥 접근을 통한 혈관조영술이 시행되었다. 동맥색전술 만으로도 혈류량이 효과적으로 감소되었다. 5개월 동안의 경과관찰에서 재발되지 않았다. 본 연구는 성장기 환자에서 이환된 혈관의 색전술이 외과적 절제술보다 더 효과적이고 안전한 방법이 될 수 있다고 보고하는 바이다.