An assessment of friction factor and viscosity models for predicting the refrigerant characteristics in adiabatic capillary tubes (마찰 계수와 점성 계수 모델이 단열 모세관 유동에 미치는 영향 평가)

  • Son, Ki-Dong;Park, Sang-Goo;Jeong, Ji-Hwan;Kim, Lyun-Su
    • Proceedings of the SAREK Conference
    • /
    • 2008.11a
    • /
    • pp.47-54
    • /
    • 2008
  • Capillary tubes are widely used as expansion device in small refrigeration systems. The refrigerant flowing in the capillary tube experiences frictional and accelerational head losses, and flashing, simultaneously. In this paper flow characteristics of adiabatic capillary tubes with various friction factor models, two-phase viscosity models, and two-phase frictional multiplier models were simulated. The predicted pressure distribution, mass flow rate are compared with experimental data reported in literature. It is confirmed that the predicting accuracy with homogeneous model can be improved by employing the suitable correlations of friction factor and two-phase viscosity model, and two-phase frictional multiplier.

  • PDF

Development of Infiltration Model Considering Temporal Variation of Soil Physical Properties Under Rainfalls (토양의 물리적 특성의 변화를 고려한 강우의 침투모형 개발)

  • 정하우;김성준
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.35 no.3
    • /
    • pp.36-46
    • /
    • 1993
  • The purposes of this study are to develop three-layered Green-Ampt infiltration model considering temporal variation of physical properties of soil and to evaluate the model with field experiment on bare-tilled and soybean-growing soil plots under natural rainfalls. Infiltration tests were conducted on a sandy loam soil. The model has three-layered soil profile including a surface crust, a tilled layer, a subsoil and considers temporal variation of porosity, hydraulic conductivity, capillary pressure head on a tilled layer by natural rainfalls and canopy density variation of crop. Field measurement of porosity, average hydraulic conductivity and average capillary presure head on a tilled layer were conducted by soil sampler and air-entry permeameter at regular intervals-after tillage. It was found that temporal variation of porosity and average hydraulic conductivity might be expressed as a function of cumulative rainfall energy and average capillary pressure head might be expressed as a function of porosity of a tilled soil. The model was calibrated by an optimization technique, Hooke and Jeeves method using hourly surface runoff data. With the calibrated parameters, the model was verified satisfactorily.

  • PDF

An Experimental Study of Liquid.Gas Heat Exchange Pipe Inserted Capillary Tube for Room Air-Conditioner (모세관 삽입 룸 에어컨용 액.가스 열교환 배관에 관한 실험적 연구)

  • Kim, Jae-Dol
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.30 no.6
    • /
    • pp.702-708
    • /
    • 2006
  • This study shows the experimental characteristics of the double pipe inserted liquid pipe with small diameter in the gas pipe with large diameter for circulating of a liquid of high temperature, pressure and a gas of low temperature, pressure at the same time. So the functions of pipe and pipe's expansion and heat transfer are presented simultaneously. In the result, the temperature of gas refrigerant at the inlet of compressor increased about $5^{\circ}C$ by the heat transfer with liquid refrigerant in case of the double pipe. And liquid gas refrigerant which the temperature at the inlet of evaporator decreased about $3^{\circ}C$ comparing with the existing type flows into an evaporator COP of the double pipe increased about $7{\sim}10%$ comparing with that of the conventional pipe. And the noise of the double pipe at capillary tube is less than that of the conventional type about 3dB. Consequently. it is convinced the superiority of the double pipe in the heat loss and soundproofing aspect.

A Study on the Heat Transfer Characteristics of Loop Type Capillary Heat Pipe (루프형 세관 히트 파이프의 열전달특성에 관한 연구)

  • Yoon, Suck-Hun;Choi, Jae-Hyuck
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.24 no.3
    • /
    • pp.346-353
    • /
    • 2000
  • In this paper, heat transfer characteristics of a loop type capillary heat pipe were experimentally investigated for the effect of several fill charge ratios of working fluid and heat loads. This type of heat pipe consists of a heating section, a cooling section and an adiabatic section. The heat pipe used has a 0.002m internal diameter, a 0.34m length in one turn and consists of 19 turns. Heating and cooling sections each have a length of 70mm. Experiments were performed to measure the temperature distributions and the pressure variation of the heat pipe. Heat transfer performance, effective thermal conductivity, boiling heat transfer and condensation heat transfer coefficients were calculated for various operating conditions of heat pipe and it was found that heat transfer characteristics of this type heat pipe were very excellent. As shown by this experimental study, this type of heat pipe operates by oscillatory flow caused by pressure and temperature oscillations.

Soft Plasma Flash X-ray Generator Utilizing a Vacuum Discharge Capillary

  • Sato, Eiichi;Hayasi, Yasuomi;Usuki, Tatsumi;Sato, Koetsu;Takayama, Kazuyoshi;Ido, Hideaki
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.400-403
    • /
    • 2002
  • The fundamental experiments for measuring soft x-ray characteristics from the vacuum capillary are described. These experiments were primarily performed in order to generate line spectra such as x-ray lasers. The generator consists of a high-voltage power supply, a polarity-inversion ignitron pulse generator, a turbo-molecular pump, and a radiation tube with a capillary. A high-voltage condenser of 200 nF in the pulse generator is charged up to 20 kV by the power supply, and the electric charges in the condenser are discharged to the capillary in the tube after closing the ignitron. During the discharge, weakly ionized plasma forms on the inner and outer sides of a capillary. In the present work, the pump evacuates air from the tube with a pressure of about 1 mPa, and a demountable capillary was developed in order to measure x-ray spectra according to changes in the capillary length. In this capillary, the anode (target) and cathode elements can be changed corresponding to the objectives. The capillary diameter is 2.0 mm, and the length is adjusted from 1 to 50 mm. When a capillary with aluminum anode and cathode electrodes was employed, both the cathode voltage and the discharge current almost displayed damped oscillations. The peak values of the voltage and current increased when the charging voltage was increased, and their maximum values were -10.8 kV and 4.7 kA, respectively. The x-ray durations observed by a 1.6 ${\mu}$m aluminum filter were less than 30 ${\mu}$s, and we detected the aluminum characteristic x-ray intensity using a 6.8 ${\mu}$m aluminum filter. In the spectrum measurement, two sets of aluminum and titanium electrodes were employed, and we observed multi-line spectra. The line photon energies seldom varied according to changes in the condenser charging voltage and to changes in the electrode element. In the case where the titanium electrode was employed, the line number decreased with corresponding decreases in the capillary length. Compared with incoherent visible light, these rays from the capillary were diffracted and diffused greatly after passing through two slits.

  • PDF

Effects of Sagungsan on the Hemostasis, Intracranial Pressure, Blood Pressure and Cardiovascular System in Expreimental Animals (사궁산(莎芎散)이 실험동물(實驗動物)의 지혈(止血), 뇌압(腦壓), 혈압(血壓) 및 심혈관계(心血管系)에 미치는 영향(影響))

  • An, Il-Hoe;Park, Young-Soon;Kim, Seh-Gil
    • The Journal of Internal Korean Medicine
    • /
    • v.15 no.1
    • /
    • pp.80-98
    • /
    • 1994
  • According to the original documents, Sagungsan is considered as an effective drug for controlling the hypertensive epistaxis induced by tension of autonomic nerve and it's hyperfunction. The present experiment was designed to understand the effect of Sagungsan extract on the hemostatic action, intracranial pressure, blood pressure and cardiovascular system in experimental animals. And thus the bleeding time, prothrombin time, capillary dilation, blood pressure, Intracranial pressure, and enzymatic analysis of the ATPase activities were studied. The result obtained here were as followings: 1. Sagungsan water extract reduced the bleeding time in mouse, and prolonged the prothrombin time in rabbits. 2. The drug extract increased the tail volume by capillary dilation in rats. 3. The drug extract inhibited the increase of intracranial pressure and arterial blood pressure in rabbits. 4. At the early time, the increase of arterial blood pressure by the drug extract significantly inhibited by pretreated atropin and regitine in rabbits. 5. The drug extract relaxed the smooth muscle by stimulating the Mg2+-Ca2+-ATPase activities of gastric sarcoplasmic reticulum isolated from rabbit stomach. 6. The drug extract stimulated the heart contraction by inhibiting the $Mg^{2+}-Ca^{2+}-ATPase$ activities of cardiac sarcoplasmic reticulum isolated from rabbit heart. The inhibitory mechanism was reversible and noncompatitive. 7. The drug extract increased the hepatic blood volume by stimulating the hepatic total ATPase activities and hepatic metabolism. 8. The drug extract acted as a tranquilizer by inhibiting the neural Na+-K+-ATPase activity. According to the results, Sagungsan water extract dilated the capillaries, stimulated the heart beat, and thus increased the blood flow with decreasing the intracranial pressure and blood pressure. These effects stanches the epistaxis collectively.

  • PDF

Comparison of Viscosity Measurement of a Liquid Carbon Dioxide Used for a High-Pressure Coal Gasifier (고압 석탄 가스화기용 액상 이산화탄소의 점성측정 방법비교에 관한 연구)

  • KIM, KANGWOOK;KIM, CHANGYEON;KIM, HAKDUCK;SONG, JUHUN
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.26 no.6
    • /
    • pp.581-589
    • /
    • 2015
  • In this study, the viscosity of a liquid carbon dioxide ($LCO_2$) that can potentially be used in a wet feed coal gasifier was evaluated. A pressurized capillary viscometer was employed to obtain the viscosity data of $LCO_2$ using two different methods. During the first method, the measurements were conducted under quasi-steady and high pressure flow conditions where two-phase flow was greatly minimized. The viscosity of $LCO_2$ was determined using turbulent friction relationship. At the second flow condition where unsteady flow is induced, the viscosity of $LCO_2$ was measured using the half-time pressure decay data and was further compared with values calculated by the first method.

Permeability Measurement of a Circular Braided Preform for Resin Transfer Molding

  • Cho, Yun Kyoung;Song, Young Seok;Kang, Tae Jin;Chung, Kwansoo;Youn, Jae Ryoun
    • Fibers and Polymers
    • /
    • v.4 no.3
    • /
    • pp.135-144
    • /
    • 2003
  • Permeability of the preform is one of key factors in design of RTM (Resin Transfer Molding) mold, determination of processing conditions, and modeling of flow in the mold. According to previous studies, permeability measured in the unsaturated fiber mats are higher than that in the saturated fiber mats by about 20% because of the capillary pressure. In this study, permeabilities of several fiber preforms are measured for both saturated and unsaturated flows. A saturated experiment of radial flow has been adopted to measure the permeability of anisotropic fiber preforms with high fiber content, i.e., circular braided preforms. In this method, four pressure transducers are used to measure the pressure distribution. Permeabilities in different directions are determined and the experimental results show a good agreement with the theory. Since permeability is affected by the capillary effect, permeability should be measured in the unsaturated condition for the textile composites to be manufactured under lower pressure as in the Vacuum Assisted Resin Transfer Molding (VARTM).

Discrimination of Geographical Origin far Ligusticum Root (Ligusticum wallichii) by Capillary Electrophoresis (Capillary electrophoresis(CE)를 이용한 천궁의 원산지 판별)

  • Kim, Jung-Hyun;Kim, Eun-Young;Chung, Kyung-Sook;Rhyu, Mee-Ra
    • Applied Biological Chemistry
    • /
    • v.46 no.4
    • /
    • pp.380-384
    • /
    • 2003
  • Optimal extraction, separation and capillary rinsing conditions for capillary electrophoresis (CE) were established to discriminate the geographical origin of ligusticum root (Ligusticum wallichii) using 113 samples (domestic sample n = 62, foreign sample n = 51). Ligusticum root was extracted with 30% ethanol and separated on a uncoated fused-silica $(50\;{\mu}m{\times}27\;cm)$ capillary. Conditions for optimal analysis include: temperature, $40^{\circ}C$; voltage, 10 kV; and pressure injection time, domestic and foreign samples were 5 sec and 2 sec, respectively. The optimal separation buffer was 0.1 M phosphate buffer (pH 2.5) containing 15 mM iminodiacetic acid with 40% methanol. Under the optimal conditions established for CE, the ratio of specific peak area (peak LW-1) to other peak area (peak LW-5) was effective in discrimination geographical origin of ligusticum root. The mean accuracy for correct discrimination of geographical origin of domestic and foreign ligusticum roots were 65% and 63%, respectively.