• Title/Summary/Keyword: Capacity-building

Search Result 1,769, Processing Time 0.03 seconds

Component deformation-based seismic design method for RC structure and engineering application

  • Han, Xiaolei;Huang, Difang;Ji, Jing;Lin, Jinyue
    • Earthquakes and Structures
    • /
    • v.16 no.5
    • /
    • pp.575-588
    • /
    • 2019
  • Seismic design method based on bearing capacity has been widely adopted in building codes around the world, however, damage and collapse state of structure under strong earthquake can not be reflected accurately. This paper aims to present a deformation-based seismic design method based on the research of RC component deformation index limit, which combines with the feature of Chinese building codes. In the proposed method, building performance is divided into five levels and components are classified into three types according to their importance. Five specific design approaches, namely, "Elastic Design", "Unyielding Design", "Limit Design", "Minimum Section Design" and "Deformation Assessment", are defined and used in different scenarios to prove whether the seismic performance objectives are attained. For the components which exhibit ductile failure, deformation of components under strong earthquake are obtained quantitatively in order to identify the damage state of the components. For the components which present brittle shear failure, their performance is guaranteed by bearing capacity. As a case study, seismic design of an extremely irregular twin-tower high rise building was carried out according to the proposed method. The results evidenced that the damage and anti-collapse ability of structure were estimated and controlled by both deformation and bearing capacity.

Heating and Cooling Load Evaluation Study with TAC Based BIN Data (TAC를 반영한 BIN 데이터 기반의 냉난방 부하 변화에 관한 연구)

  • Lee, Kwang Seob;Kim, Yu Jin;Min, Kyung Chon;Lee, Euy Joon;Kang, Eun Chul
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.29 no.9
    • /
    • pp.463-471
    • /
    • 2017
  • According to the Korea industrial standard of air conditioning systems (KS C 9306), cooling and heating loads for buildings can be calculated by using maximum and minimum temperature in BIN data. Cooling and heating loads can be determined by building set temperature and ambient temperature. Cooling and heating system capacity of buildings can be normally designed according to determined heating and cooling loads. Cooling and heating system capacity can be reduced by updated BIN data, applying TAC (Technical Advisory Committee) values. In this study, updated BIN data have been analyzed using ambient temperature of 19 areas in Korea for the last 10 years (2005~2014) provided by KMA (Korea Meteorological Administration). Building cooling and heating loads have been calculated following TAC based BIN data. As a result, designed system capacity decreased depending on applying TAC. Those were reduced as 7.1% ($100m^2$ building), 8.7% ($1,000m^2$ building) in cooling capacity, 11.7% in heating capacity when TAC 2.5% applied. And also, it is expected system initial and operating cost by decreasing system capacity.

Development of Capacity Spectrum Method for Shear Building to Estimate the Maximum Story Drift (전단빌딩의 최대 층간변위를 예측하기 위한 역량스펙트럼법 개발)

  • Kim, Sun-Pil;Kim, Doo-Kie;Kwak, Hyo-Gyoung;Ko, Sung-Hyuk
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.20 no.3
    • /
    • pp.255-264
    • /
    • 2007
  • In the current domestic and overseas standards concerning seismic design, especially on the capacity & demand spectra in the multi-story building, failure is caused more by story drift than by displacement; and the existing capacity spectrum method (CSM) does not make a close estimate of story drift because response is derived using displacement. Therefore, this paper proposes an improved CSM to estimate story drift and its direct effect on the collapse of structures, yet still maintaining the same advantage and convenience of the existing CSM about a most basic model of multi-story building: shear building. To establish its reliability, the proposed method is applied to an example model and results are then compared with those obtained through nonlinear time-history analysis.

An Evaluation of Seismic Performance for Existing School Building Using Capacity Spectrum Method (성능스펙트럼법을 이용한 기존 학교 건축물의 내진성능평가 및 보강효과 검증)

  • Jang, Jeong-Hyun;Hwang, Ji-Hoon;Yang, Kyeong-Seok;Takashi, Kamiya;Choi, Jae-Hyouk
    • Journal of Advanced Engineering and Technology
    • /
    • v.5 no.1
    • /
    • pp.11-18
    • /
    • 2012
  • Large scale earthquake was occurred in different parts of the world like Japan (in 1995), Republic of Pakistan (2005), in China (2008) etc and enormous structures were damaged. As a result of collapse of school buildings structures numerous students are died and it had a big impact on the international community. Therefore, the interest of preparing the seismic resistant school building structures in our country is increases as school building are used as emergency shelter for local residents. But the current standard of seismic design ratio of 3.7% is applied for school building in Korea which is only significant earthquake damage is expected. In order to overcome the current situation, seismic performance evaluation is carried out for the existing school building and an accurate and appropriate seismic retrofit is required based on performance evaluation to upgrade the existing school buildings. In this paper, nonlinear analysis on existing school buildings for ATC-40(Applied Technology Council, ATC) and FEMA-356(Federal Emergency Management Agency, FEMA) are carried out using the capacity spectrum method to evaluate seismic performance and to determine the need for retrofitting. In addition, after reinforcement to enhance the seismic performance is applied the seismic performance evaluation is carried out to verify the effectiveness of seismic retrofit.

A Study on Ductility Capacity of Reinforced Concrete Beam without Shear Reinforcement Using Cockle Shells as Fine Aggregate (고막 패각을 잔골재로 사용한 전단보강근이 없는 철근콘크리트 보의 연성에 관한 연구)

  • Kim, Jeong-Sup;Kim, kwang-seok
    • Journal of the Korea Institute of Building Construction
    • /
    • v.5 no.2 s.16
    • /
    • pp.139-146
    • /
    • 2005
  • As a result of compressive strength, specimens having mixture rate of cockle shells of $15\%\;and\;20\%$ showed more increases of compressive strength than non-mixture specimens as age increases. Ductility capacity of specimens was higher in specimens mixing cockle shells than in specimens using general fine aggregates and specimen of $10\%$ of cockle shells was highest in ductility capacity. To sum up all experimental results, ductility capacity of specimen without shear reinforcement using mixture of cockle shell was higher than non-mixture specimen and it is considered that mixture of cockle shells up to $20\%$ as fine aggregate for concrete will be available. Continuous researches on durability, workability and economy of crushed cockle shells used for substitute fine aggregate of concrete will be needed.

Study on the Railway Station Building's Electrical Capacity Analysis and the Lighting Load (철도역사 건물 전기용량 분석과 조명부하에 관한 연구)

  • Kang, Og-Goo;Jang, Woojin
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.63 no.2
    • /
    • pp.102-106
    • /
    • 2014
  • Energy saving is as important as developments of green energy and alternative energy. The need for development of high-efficiency lighting apparatus further increased. This paper compared with the size of electrical equipment and analyzed the size of electrical capacity for the railway station building. Also discussed energy saving measures that can be achieved by using high-efficacy lighting fixtures, and the percentage of the lighting load capacity of the entire building.

Effect of Two Glomus Species Inoculations on Survival, Photosynthetic Capacity, Growth, Morphology ana Root Ginsenoside Content of Panax quinquefolius L.

  • Fournier, Anick R.;Khanizadeh, Shahrokh;Gauthier, Louis;Gosselin, Andre;Dorais, Martine
    • Journal of Ginseng Research
    • /
    • v.27 no.4
    • /
    • pp.178-182
    • /
    • 2003
  • Vesicular-arbuscular mycorrhizae (VAM) fungi naturally colonise American ginseng roots and this relationship is highly beneficial to enhance plant productivity. Our goal was to determine the effect of adding two Glomus species (Glomus etuticatum, G. intraradices) on survival, photosynthetic capacity, growth, morphology and root ginsenoside content of one-year-old American ginseng plants grown in a broadleaf forest. While our study revealed that VAM inoculations significantly affected root morphology and Re ginsenoside content, the survival, photosynthetic capacity and root growth of American ginseng plants were not significantly influenced by VAM inoculations. Surface area and volume of rootlets were 16-25% higher for ginseng grown in VAM-inoculated soil compared to those grown in the control plots. Also, Re ginsenoside content was 18 % higher in YAM-inoculated roots compared to controls.

An Examination on capacity of heat source system and the operating rate for safety factor in office building (사무소 건물 열원기기 용량과 가동률에 대한 안전율의 적정성 검토)

  • Ha, Jong-Sung;Lee, Dong-Soo;Cha, Bong-Min;Jang, Jong-Woon;Kim, Se-Hwan
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.512-518
    • /
    • 2006
  • Economize the energy, further study is highly needed at the very beginning stage of the building plan. To fulfill this study, research of the buildings in Busan will be carried out, and find out the relations between pure load of buildings and capacity of heat & cooling equipment. Therefore this study is suggesting better idea of calculating capacity from having a thorough grasp of the problem with comparing and analyzing of extra-factor.

  • PDF

The effect of finite element modeling assumptions on collapse capacity of an RC frame building

  • Ghaemian, Saeed;Muderrisoglu, Ziya;Yazgan, Ufuk
    • Earthquakes and Structures
    • /
    • v.18 no.5
    • /
    • pp.555-565
    • /
    • 2020
  • The main objective of seismic codes is to prevent structural collapse and ensure life safety. Collapse probability of a structure is usually assessed by making a series of analytical model assumptions. This paper investigates the effect of finite element modeling (FEM) assumptions on the estimated collapse capacity of a reinforced concrete (RC) frame building and points out the modeling limitations. Widely used element formulations and hysteresis models are considered in the analysis. A full-scale, three-story RC frame building was utilized as the experimental model. Alternative finite element models are established by adopting a range of different modeling strategies. Using each model, the collapse capacity of the structure is evaluated via Incremental Dynamic Analysis (IDA). Results indicate that the analytically estimated collapse capacities are significantly sensitive to the utilized modeling approaches. Furthermore, results also show that models that represent stiffness degradation lead to a better correlation between the actual and analytical responses. Results of this study are expected to be useful for in developing proper models for assessing the collapse probability of RC frame structures.

An Analysis of Various Factors that Determines the Size of Electric Room(22.9Kv class) (전기실의 면적을 결정하는 제 요소의 분석(22.9Kv class))

  • Eo, Ik-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2001.07a
    • /
    • pp.443-445
    • /
    • 2001
  • As the new large buildings are continuously being built with the advanced technology and skills, an adequate size of electric room needs to be obtained so that engineers establish an efficient and reliable system in the electric room. Considering the current capacity, its expansion and its connecting system, the final size of it should be determined in order to bring an effective use of the building. Usually the extension of electricity capacity is on the increase after construction and it comes from the lack of scientific evaluation on the electric room. Later when the expansion of computer and important electric equipment that needs much capacity is impossible, it will cause a great deal of damage to the renting business of the building as well as becomes the unstable factors of the whole system. Therefore, it is important to have the exact method of calculating the effective size of electric room, the heart of the building, especially when the value of land price is very high. In addition, it should be calculated in an accurate way due to the diversification of the system and the compact size of the electricity equipment. However, the research on this area and the comparison and evaluation of the size after construction have not been made enough and the results of them have not been applied when calculating a new size of electric room. Accordingly, this study examines three methods prescribed in the standards of electricity installation technology through case analysis and suggests substantial data by system, capacity, and purpose.

  • PDF