• 제목/요약/키워드: Capacity utilization

검색결과 866건 처리시간 0.028초

교차로 용량분석을 위한 교통류 특성 기초조사 (A Basic Investigation on the Characteristics of Traffic Flow for the Capacity Analysis of Signalized Intersections)

  • 이승환
    • 대한교통학회지
    • /
    • 제7권2호
    • /
    • pp.89-111
    • /
    • 1989
  • This study concentrates on a basic investigation research related to some of parameters to be used for the analysis of capacity and the level of service for signalized intersections. The parameters to be studied are ideal saturation flow rate, large vehicle's passenger car equivalent(PCE) ane the lane utilization factors of through and left turn vehicles. The field data were collected at six intersections in Seoul using video cameras so as to reflect conditions in urban areas. In this study discharge headway based on a rear bumper of each vehicle was used and all the parameters were estimated using a regression technique. The findings of this research are as follows : 1. The saturation headway and saturation flow rate on a single lane with the lane width of 3.1m are 1.652 seconds and 2,180 pcphgpl. It was found that the frist 5 vehicles in the queue experience some start-up lost time. 2. It was confirmed that the new method adopted for the estimate of large vehicle's PCE gives larger PCE values than those derived from the method commonly used. 3. For the estimate of lane utilization factors of through and left turn vehicles, a relationship was established and the corresponding formulas were developed.

  • PDF

CXL 메모리 및 활용 소프트웨어 기술 동향 (Technology Trends in CXL Memory and Utilization Software )

  • 안후영;김선영;박유미;한우종
    • 전자통신동향분석
    • /
    • 제39권1호
    • /
    • pp.62-73
    • /
    • 2024
  • Artificial intelligence relies on data-driven analysis, and the data processing performance strongly depends on factors such as memory capacity, bandwidth, and latency. Fast and large-capacity memory can be achieved by composing numerous high-performance memory units connected via high-performance interconnects, such as Compute Express Link (CXL). CXL is designed to enable efficient communication between central processing units, memory, accelerators, storage, and other computing resources. By adopting CXL, a composable computing architecture can be implemented, enabling flexible server resource configuration using a pool of computing resources. Thus, manufacturers are actively developing hardware and software solutions to support CXL. We present a survey of the latest software for CXL memory utilization and the most recent CXL memory emulation software. The former supports efficient use of CXL memory, and the latter offers a development environment that allows developers to optimize their software for the hardware architecture before commercial release of CXL memory devices. Furthermore, we review key technologies for improving the performance of both the CXL memory pool and CXL-based composable computing architecture along with various use cases.

공공부문 하드웨어 규모산정 지침 활용 활성화 방안에 대한 연구 - 제도적 측면을 중심으로 - (The Role of Government A Study on Utilization Method of Hardware Sizing Guidelines in Public Sector - In aspect of institutional viewpoint -)

  • 최광돈;정해용;나종회
    • 디지털융복합연구
    • /
    • 제4권1호
    • /
    • pp.73-81
    • /
    • 2006
  • In this study, It is suggested how to utilize hardware capacity sizing system for WEB, WAS, OLTP server's CPU, memory, and disk capacity by its user reasonably. To achieve goal of this study, we presented specific approaches in aspect of institutional viewpoint. The result of this study can be reflected gradually in the guideline of informatization related budgeting by MPB(Ministry of Planning and Budget) and e-government supporting program.

  • PDF

정전비용을 고려한 신재생에너지원의 최적 연계 용량 및 연계 위치 결정에 관한 연구 (Determining Optimal Installed Capacity and the Interconnected Bus of Renewable Energy Sources Considering the Cost of Energy Not Supplied)

  • 김성열;이성훈;김진오
    • 전기학회논문지
    • /
    • 제61권10호
    • /
    • pp.1393-1398
    • /
    • 2012
  • Due to environmental regulation and technical improvements, renewable energy sources (RES) are increasingly penetrated and operated in power systems. Clean energy technologies have become cost-competitive with conventional power systems, and in the near future, the generation cost of RES is expected to approach grid parity. In this situation, it should be considered an extraordinarily important issue to be maximized resulting in utilization of RES as well as to develop technologies for efficiency improvement of RES. Therefore, in this paper, the method for determining an optimal installed capacity and interconnected location of RES is proposed in order to minimize the cost of energy not supplied, which can contribute to improve distribution reliability.

전력보상설비의 상호 협조제어에 따른 운영여유용량의 확보 (Securing Operation Margin Capacity as Coordination Control among the Power Compensation Equipments)

  • 이상덕;백영식
    • 전기학회논문지
    • /
    • 제59권6호
    • /
    • pp.1011-1016
    • /
    • 2010
  • It is an important issue to electric power system operations that it can reliably supply large-capacity power to consumption area as due to increasing power demand growth. For this purpose, The FACTS equipment based on Power IT technology with the existing mechanical compensators has been applied to power system. Therefore we suggest on this paper that a plan for coordination control of multiple power compensation equipment in order to increase the utilization of each facility and secure operation margin capacity. As the result of simulation, it is possible to cope actively with a suddenly changed power system. This helps greatly for the voltage stability and supply reliability in a suddenly changed power system.

하수처리장 변압기 설치사례 연구를 통한 전력손실 저감방안 (Case Studies on the Electric Power Loss Reducing Methodology for Transformer Installation in Sewage Treatment Plant)

  • 김주영;최창규
    • 조명전기설비학회논문지
    • /
    • 제25권1호
    • /
    • pp.70-77
    • /
    • 2011
  • Sewage treatment plants, consuming 1,756[GWh] which is 0.53[%] of national wide electricity consumption, is one of the electricity consuming facilites. At the research of electricity consumption and power quality analysis on sewage treatment plants, average utilization of transformer was less than 40[%] because peak load was very lower than its capacity due to excess capacity. So reduction of power loss can be achieved by transformer design optimization. The achievement in this research, is to meet reduction of power loss through optimizing the capacity and to improve as high efficiency-low loss transformer while the transformer is operating.

공공부문 하드웨어 규모산정 지침 활용 활성화 방안에 대한 연구 - 제도적 측면을 중심으로 - (The Role of Government A Study on Utilization Method of Hardware Sizing Guidelines in Public Sector - In aspect of institutional viewpoint -)

  • 최광돈;정해용;나종회
    • 한국디지털정책학회:학술대회논문집
    • /
    • 한국디지털정책학회 2006년도 춘계학술대회
    • /
    • pp.311-318
    • /
    • 2006
  • In this study, It is suggested how to utilize hardware capacity sizing system for WEB, WAS, OLTP server's CPU, memory, and disk capacity by its user reasonably. To achieve goal of this study, we presented specific approaches in aspect of institutional viewpoint. The result of this study can be reflected gradually in the guideline of informatization related budgeting by MPB(Ministry of Planning and Budget) and e-government supporting program.

  • PDF

시뮬레이션 기법을 이용한 주문형 멀티미디어 서버의 성능 평가 (A Performance Evaluation of Multimedia-on-demand Server Using Simulation Method)

  • 박기진
    • 한국시뮬레이션학회논문지
    • /
    • 제7권2호
    • /
    • pp.33-43
    • /
    • 1998
  • To evaluate the server performance and forecast capacity requirements, we carry out simulation of Multimedia-on-demand(MOD) server. In multimedia service environment, especially for on-demand service, one of the key problems is capacity planning, which requires ensuring that adequate computer resources will be available to meet the future workload demands in a cost-effective manner. In this paper, we design and implement a simulation model for MOD server with failures of components (e.g., processors, disks and networks). By acquisition of utilization and queue length parameters, we can estimate desirable capacity of server components with various arrival rates of customers and failure rates of components. For a given failure probability, we also compute packet delay probability and reliability of the server. It is possible to derive some important design information of the MOD server by using the above parameters.

  • PDF

재고설비규모를 위한 최적분배 모델의 연구 (A Study on the Optimum Allocation Model for Inventory Capacity)

  • 최진영;정기호
    • 산업경영시스템학회지
    • /
    • 제5권6호
    • /
    • pp.1-6
    • /
    • 1982
  • The objective of this thesis to Provide a better insight into the effect of the amount of in-process storage has on the efficiency of production line with variable operation times. It is assumed that the material enters the line at the first work station and is then processed progressively through the line until it exits at the last work station, a finite amount of in-process storage is provided before all but the first work station of the line and the operation time of the work stations are statistically independent and follow exponential distribution. Under the above assumption, optimum allocation model is developed and following two approaches are used : 1) Given the available storage capacity, optimum allocation which minimizes the number of items in the line. 2) Given the available storage capacity, optimum allocation which. maximizes the utilization factor of the line. In a balanced three stage line, the production line efficiency is maximized under both categories when the second in-process storage is larger than the first.

  • PDF

아이스 슬러리의 수송 및 냉열이용에 관한 연구 (A Study on Transport and Heat Utilization of Ice Slurries)

  • 길복임;이윤표;정동주;조봉현;최은수
    • 설비공학논문집
    • /
    • 제13권11호
    • /
    • pp.1065-1071
    • /
    • 2001
  • To investigate hydraulic and thermal characteristics of ice slurries in a circular tube, ice slurries were tested in a flow loop with a constant heat flux test section, for ranges of flow velocity, ice fraction and heat flux. Heat transfer coefficients and friction factors of ice slurries were calculated by measuring the outer wall temperatures of the test section and the pressure drops over the test section. Heat transfer coefficients of ice slurries were 9% higher than the heat transfer coefficients expected by Petukhov. Friction factors were about 4% lower than the friction factors expected by Petukhov. The effective thermal capacity of ice slurry with 12.8% ice fraction, was found to be about 3 times higher than the thermal capacity of water.

  • PDF