• Title/Summary/Keyword: Capacity Range

Search Result 1,877, Processing Time 0.027 seconds

A Study on Physiological Parameter, Physical Health Status, and Health Perception in the Elderly (노인의 생리적 지수와 신체건강 상태, 건강지각과의 관계연구)

  • Han, Ae-Kyung
    • Korean Journal of Adult Nursing
    • /
    • v.16 no.3
    • /
    • pp.460-469
    • /
    • 2004
  • Purpose: The purpose was to investigate the physiological parameter and physical health status and health perception in the elderly, and to find the correlation between these variables. The subjects were 139 in Kyungi senior center. Method: The instruments for this study were physiological parameters, which were composed of vital capacity, blood pressure, pulse oxygenation, hand grip power, body fat and physical health status scale developed by researcher, and health perception scale developed by Ware(1976). The data were analyzed by the SPSS-PC 11.0 version. Results: 1) 7.9% of subjects were included in abnormal range of vital capacity, 40.3% were systolic hypertension and 11.5% were diastolic hypertension. And 92.1% were included in normal range of pulse oxygenation, 79.8% were weakened hand grip power, and 10.1% of subjects were included in normal range of body fat. 2) The total mean score of the physical health status was 26.34 of a possible maximum score of 45. The physical health status score of women was lower than man's. 3) The mean score of man's health perception was 24.52 and women's was 20.39 of a possible maximum score of 44. 4) There was a significant positive correlation between hand grip power and physical health status(r=.28, p=.001). And a significant correlation between physical health status and health perception was found (r=.24, p=.004). Conclusion: It is concluded that the blood pressure, hand grip power and body fat among the physiological parameters of elderly subjects in Kyungi senior center were included in abnormal range. The factors were related life style. therefore, it is suggested that the health education to change life style for the elderly is needed.

  • PDF

Scope Minimization of Join Queries using a Range Window on Streaming XML Data (스트리밍 XML 데이타에서 영역 윈도우를 사용한 조인 질의의 범위 최소화 기법)

  • Park, Seog;Kim, Mi-Sun
    • Journal of KIISE:Databases
    • /
    • v.33 no.2
    • /
    • pp.224-238
    • /
    • 2006
  • As XML became the standard of data exchange in the internet, the needs for effective query processing for XML data in streaming environment is increasing. Applying the existing database technique which processes data with the unit of tuple to the streaming XML data causes the out-of-memory problem due to limited memory volume. Likewise the cost for searching query path and accessing specific data may be remarkably increased because of special structure of XML. In a word it is unreasonable to apply the existing database system to the streaming environment that processes query for partial data, not the whole one. Thus, it should be able to search partial streaming data that rapidly satisfies join predicate through using low-capacity memory, based on a store technique suitable to streaming XML data. In this thesis, in order to study the store technique for low-capacity memory, the PCDATA and the CDATA-related parts, which can be used as predicate on join query, were fetched and saved. In addition, in an attempt to compare rapid join predicates, the range window of streaming XML data was set with the object of selectively joining windows that satisfies the query, based on Cardinality * and + among the structure information of DTD.

Comparisons of Regeneration Methods Using Physical and Chemical Treatment for Phosphate Removal Restoration of Filter Media (여재의 인 제거기능 회복을 위한 물리화학적 재사용 방안 비교)

  • Kim, Ji Ah;Choi, I Song;Oh, Jong Min;Kim, Won Jae;Park, Jae Roh
    • Ecology and Resilient Infrastructure
    • /
    • v.3 no.3
    • /
    • pp.201-206
    • /
    • 2016
  • The purpose of this study is to find the regeneration method of filter media using physical and chemical treatment for restoration of phosphorus adsorption ability. The filtration material used in this study is called Adphos. In an experiment of heating treatment, re-used filter media is heated to a high temperature before the adsorption test. The results show that the $PO{_4}^{3-}-P$ adsorption capacity is in the range of 0.0021 - 0.0030 mg/g and the removal efficiency is in the range of 26.1 - 39.4%. In the experiment of acid or basic treatment, re-used filter media is exposed to a different pH condition before the adsorption test. The results show that the $PO_4^{3-}-P$ adsorption capacity is in the range of 0.0010 - 0.0066 mg/g and the removal efficiency is in the range of 15.8 - 87.1% after the acid treatments which have pH values of 1 - 5. However, after the basic treatments which have pH values of 8 - 11, the results show that the $PO{_4}^{3-}-P$ adsorption capacity is in the range of 0.0018 - 0.0034 mg/g and the removal efficiency is in the range of 26.7 - 48.0%. In an experiment of chemical treatment using NaCl, re-used filter media was exposed to a different NaCl concentration before the adsorption test. The results show that the $PO{_4}^{3-}-P$ adsorption capacity is in the range of 0.0036 - 0.0050 mg/g and the removal efficiency is in the range of 50.5 - 71.1%. In conclusion, chemical treatment using NaCl shows a high recovery probability of phosphorus adsorption ability of filter media.

Experimental Study on the Cooling and Heating Characteristics of System A/C Applying the Digital Scroll Compressor (디지털 스크롤 압축기를 적용한 시스템 에어컨의 냉난방특성에 대한 실험적 연구)

  • Jeon, Yong-Ho;Kim, Dae-Hoon;Kwon, Young-Chul;Jang, Geun-Sun;Lee, Yoon-Soo;Moon, Je-Nyung;Yoon, Baek;Hong, Ju-Tae
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.6
    • /
    • pp.454-460
    • /
    • 2003
  • In order to investigate the cooling and heating characteristics of a variable-capacity system A/C applying a digital scroll compressor, the cooling and heating capacities and COP are measured by the psychrometric calorimeter. The capacity of the system is controlled by the digital scroll compressor, which is operated by controling PWM valve and the loading vs. unloading time. In the case of unloading compared that of loading, the consumption power of the compressor is about 11% and the capacity variation of the system A/C is within about 1%. When the system A/C is operated under the cooling and heating standard conditions, COP is nearly uniform but cooling capacity and heating capacity increase at minimum, rated and maximum modes. The system A/C applying the digital scroll compressor is effective for the range with high load or the width of large load variation. When the auxiliary heater is on, at the cold region, the system A/C produces the excellent heating capacity.

Increasing Hosting Capacity of Distribution Feeders by Analysis of Generation and Consumption (배전선로 부하량 및 발전량 분석을 통한 신재생 접속허용용량 기준 상향에 대한 연구)

  • Kim, Seong-Man
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.5 no.4
    • /
    • pp.295-309
    • /
    • 2019
  • This paper demonstrates that the verification and analysis of the increase of hosting capacity of distributed energy resources in distribution system for the high penetration of distributed energy resources. In the case of generally designed distribution feeders in South Korea, it can host up to 10 MVA of distributed energy resources and the over voltage due to reverse power flow is prohibited beyond the range by the law of electric utility. However, it should take into consideration that there are some factors of extra hosting capacity such as generation characteristics of distributed energy resources and minimum loads that always exist to distribution system. For these reason, we choose a specific distribution system hosted 10 MVA of distributed energy resources monitored by distribution system operator and verify the impact of increasing hosting capacity such as power flow and voltage profile of distribution system. By the result, we could find that it is possible to increase the hosting capacity and define the factors to expand the hosting capacity of distributed energy resources in distribution system.

Estimation of ultimate torque capacity of the SFRC beams using ANN

  • Engin, Serkan;Ozturk, Onur;Okay, Fuad
    • Structural Engineering and Mechanics
    • /
    • v.53 no.5
    • /
    • pp.939-956
    • /
    • 2015
  • In this study, in order to propose an efficient model to predict the torque capacity of steel fiber reinforced concrete (SFRC) beams, the existing experimental data related to torsional response of beams is reviewed. It is observed that existing data neglects the effects of some parameters on the variation of torque capacity. Thus, an experimental research was also conducted to obtain the effects of neglected parameters. In the experimental study, a total of seventeen SFRC beams are tested against torsion. The parameters considered in the experiments are concrete compressive strength, steel fiber aspect ratio, volumetric ratio of steel fibers and longitudinal reinforcement ratio. The effect of each parameter is discussed in terms of torque versus unit angle of twist graphs. The data obtained from this experimental research is also combined with the data got from previous studies and employed in artificial neural network (ANN) analysis to estimate the ultimate torque capacity of SFRC beams. In addition to parameters considered in the experiments, aspect ratio of beam cross-section, yield strengths of both transverse and longitudinal reinforcements, and transverse reinforcement ratio are also defined as parameters in ANN analysis due to their significant effects observed in previous studies. Assessment of the accuracy of ANN analysis in estimating the ultimate torque capacity of SFRC beams is performed by comparing the analytical and experimental results. Comparisons are conducted in terms of root mean square error (RMSE), mean absolute error (MAE) and coefficient of efficiency ($E_f$). The results of this study revealed that addition of steel fibers increases the ultimate torque capacity of reinforced concrete beams. It is also found that ANN is a powerful method and a feasible tool to estimate ultimate torque capacity of both normal and high strength concrete beams within the range of input parameters considered.

Pressure-settlement behavior of square and rectangular skirted footings resting on sand

  • Khatri, Vishwas Nandkishor;Debbarma, S.P.;Dutta, Rakesh Kumar;Mohanty, Bijayananda
    • Geomechanics and Engineering
    • /
    • v.12 no.4
    • /
    • pp.689-705
    • /
    • 2017
  • The present study deals with the Pressure-settlement behavior of square and rectangular skirted footing resting on sand and subjected to a vertical load through a laboratory experimental study. A series of load tests were conducted in the model test tank to evaluate the improvement in pressure-settlement behavior and bearing capacity of square and rectangular model footings with and without structural skirt. The footing of width 5 cm and 6 cm and length/width ratio of 1 and 2 was used. The relative density of sand was maintained at 30%, 50%, 70%, and 87% respectively. The depth of skirt was varied from 0.25 B to 1.0 B. All the tests were carried out using a strain controlled loading frame of 50 kN capacity. The strain rate for all test was kept 0.24 mm/min. The results of present study reveal that, the use of structural skirt improves the bearing capacity of footing significantly. The improvement in bearing capacity was observed almost linearly proportional to the depth of skirt. The improvement in bearing capacity of skirted footings over footing without skirt was observed in the range of 33.3% to 68.5%, 68.9% to 127% and 146.7% to 262% for a skirt depth of 0.25 B, 0.50 B and 1.0 B respectively. The skirted footings were found more effective for sand at relative density of 30% and 50% than at relative density of 70% and 87%. The bearing capacity was found to increase linearly with footing width for footings with and without skirts. This observation was found to be consistent for footings with different skirt depths and for relative density of sand i.e., 30%, 50%, 70%, and 87%. The obtained results from the study for footing with and without skirts were comparable with available solutions from literature.

A Study on the Alloy Design of High Capacity Ti-Based Metal Hydride for Ni/MH Rechargeable Battery (Ni/MH 2차 전지용 고용량 Ti계 수소저장합금의 설계에 관한 연구)

  • Lee, Han-Ho;Lee, Jai-Young
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.7 no.1
    • /
    • pp.19-28
    • /
    • 1996
  • Ti-Mn based hydrogen storage alloy were modified by substituting alloying elements such as Zr, V and Ni in order to design a high capacity MH electrode for Ni/MH rechargeable battery. When V was substituted in Ti-Mn binary system, the crystal structure was maintained as $Cl_4$ Laves phase at a composition of $Ti_{0.2}V_{0.4}Mn_{0.4}$ and $Ti_{0.4}V_{0.2}Mn_{0.4}$ and equilibrium pressure decreased below 1 atm without decreasing hydrogen storage capacity considerably. It was found that Ni should be included in Ti-V-Mn alloy in order to hydrogenate it electrochemically in KOH electrolyte. But substitution of Ni for Mn in Ti-V-Mn system caused the increase of equilibrium pressure above 1atm and decrease of hydrogen storage capacity. Zr was able to increase the reversible hydrogen storage capacity of Ti-V-Mn-Ni alloy without considerable change of hydrogenation properties. The electrochemical discharge capacity of Ti-Zr-V-Mn-Ni system were in the range of 350 - 464mAh/g and among them $Ti_{0.8}Zr_{0.2}V_{0.5}Mn_{0.5}Ni_{1.0}$ alloy had $Cl_4$ Laves single phase and very high electrochemical discharge capacity of 464mAh/g.

  • PDF

Characteristics of Ion Exchange of Phosphate using Layered Double Hydroxides in Advanced Wastewater Treatment (하수고도처리에서 층상이중수화물을 이용한 인산 이온교환 특성)

  • Song, Ji-Hyun;Shin, Seung-Kyu;Lee, Sang-Hyup;Park, Ki-Young
    • Journal of Korean Society on Water Environment
    • /
    • v.22 no.6
    • /
    • pp.991-995
    • /
    • 2006
  • The layered double hydroxide with the insertion of chloride ions (LDH-Cl), which was synthesized by the co-precipitation method, was applied to investigate the fundamental aspects of the absorptive agent for phosphate removal from wastewater. The adsorption capacity was best described by the Langmuir-FreundIich isotherm, and the estimated isotherm parameters indicate that the LDH-CI capacity for the phosphate removal is much higher than that observed using a natural adsorbent material such iron oxide tailing. The kinetic experiment also showed that the LDH-Cl adsorption reaction rapidly at the adsorptive rate of 0.55 mg-P/g-LDH/min, implying that this adsorbent can be of use in the full-scale applications. The pH had a minimal effect on the LDH adsorption capacity in the range of 5 to 11, although the capacity dropped at the low pHs because of the change in LDH surface properties. Furthermore, other anions such as $Cl^-$ and $NO_3{^-}$ commonly found in the wastewater streams insignificantly affected the phosphate removal efficiencies, while $HCO_3{^-}$ ions had a negative effect on the LDH adsorption capacity due to its high selectivity. The phosphate removal experiment using the actual secondary effluent from a wastewater treatment plant showed the similar decrease in adsorption capacity, indicating that the bicarbonate ions in the wastewater were competing with phosphate for the adsorptive site in the surface of the LDH-Cl. Overall, the synthetic adsorbent material, LDH-Cl, can be a feasible alternative over other conventional chemical agents, since the LDH-Cl exhibits the high phosphate removal capacity with the low sensitivity to other environmental conditions.

Estimation of Bearing Capacity for Dreged and Reclaimed Ground (준설매립지반의 지지력 산정)

  • Lee, Choong-Ho;Kim, Ju-Hyun;Chae, Young-Su;Lee, Song
    • 기술발표회
    • /
    • s.2006
    • /
    • pp.320-328
    • /
    • 2006
  • In this test, there was two dimensional model loading test implemented for analysis with respect to the problem of evaluating bearing capacity and the application range on the dredged and reclaimed ground. It was got following conclusion through comparison of button's and Brown&Meyerhof"s equation with experimental result that was obtained by 2 dimensions model loading test. For the difference between average undrained shear strength by 2/3B of loading board width and under 2/3B is more than ${\pm}$ 50%, application of Nc(coefficient of bearing capacity was used in that case $\phi$=0 analysis is considered in the single layer) was declined. Brown&Meyerhof(1969)'s equation was underestimated comparing with loading test result, while Button(1953)'s equation was overestimated comparing with loading test result applied dividing as double layers of upper dessication layer and lower soft layer about dredged and reclaimed ground. Also, bearing capacity factors, Nc that was calculated by using button's equation was estimated greatly about 1.7 times more than bearing capacity factors, Nc that was calculated by using Brown&Meyerhof's equation. Bearing capacity factors, Nc that was calcuated by using Brown&Meyerhof's and Button's equation was evaluated each 2.3-3.6 times, 1.3-2.1 times smaller than bearing capacity factors, Nc5.14 that was calcuated by using Meyerhof's equation in case of unit layer.

  • PDF