• 제목/요약/키워드: Capacitor bank

검색결과 117건 처리시간 0.034초

신뢰적인 전력선 통신을 위한 라인 커플러의 개발 (Development of the line coupler for reliable power line communication system)

  • 최원호;임병노;박종연
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 D
    • /
    • pp.2009-2010
    • /
    • 2006
  • This paper presents an adaptive line coupler to match input impedance of the Power line Communication(PLC) modem between access impedance of the power line. This line coupler provides maximum signal power transmiting capability, high reliability. The structure of this coupler is simple and designed to make a easy and low cost. The proposed line coupler is suitable for Amplitude Shift Keying(ASK) or Phase Shift Keying(PSK) modem. To figure out our models, the analysis of the transmitting features of power line channel is performed in the time domain at the carrier frequency. As a result of this study, we present the values of capacitors in the capacitor bank and adaptive line coupler circuit.

  • PDF

중성점 전류 리플을 고려한 3-레벨 인버터의 공간 벡터 펄스폭 변조 기법 (A SVPWM for the Small Fluctuation of Neutral Point Current in Three-level Inverter)

  • 김래영;이요한;현동석
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1998년도 연구회 합동 학술발표회 논문집
    • /
    • pp.33-37
    • /
    • 1998
  • For the high power variable speed applications, the DCTLI(diode clamped three-level inverter) have been widely used. This paper describes the analysis of the neutral point current of the DCTLI and the improved space vector-based PWM strategy considering the switching frequency of power devices, that minimizes the fluctuation of the neutral point current in spite of high modulation index region and low power factor. It contributes to decrease the capacitance of dc-link capacitor bank and to increase the neutral point voltage controllable region. Especially, even if second (or even) order harmonic is induced in load current (at this situation, is was investigated that the general control method can not suppress the neutral point voltage variation), this PWM can provide effective control method to suppress the neutral point voltage variation. Various simulation results by means of Matlab/Simulation are presented to verify the proposed PWM.

  • PDF

전력용 콘덴서 뱅크 개폐 과도현상과 대안 (Capacitor Bank Switching Transients and Countermeasures)

  • 조성돈
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 A
    • /
    • pp.18-20
    • /
    • 2004
  • 콘덴서 뱅크는 계통의 전압 유지와 무효전력 공급을 위해 많이 사용되고 있다. 전력용 콘덴서는 주로 배전계통에 많이 사용되었으나 근래에는 송전용 계통에도 많이 투입되고 있다. 송전용 콘덴서 뱅크는 대용량이며 송전계통의 X/R비가 높기 때문에 콘덴서 뱅크 개폐시에 높은 주파수의 과도전류와 과전압과 같은 과도현상이 발생하며 이로 인해 전력계통의 신뢰도에 중요한 전력기기가 손상을 받을 수 있다. 본고에서는 154-kV 계통을 예를 들어 콘덴서 뱅크에 의해 발생하는 다음의 과도현상들과 그에 대한 대안을 검토하였다. 1) 1차 콘덴서뱅크 투입시 과도현상 2) 2차 콘덴서뱅크 투입시 과도현상 3) 단락사고시 고장전류 4)공진에 의한 과전압 과도현상해석을 위해서는 ATP(Alternative Transient Pr09ram) 프로그램을 사용하였다

  • PDF

웨이브렛 변환을 이용한 고저항 지락사고 검출 및 판별 (Fault Detection and Classification of Hi9h Impedance Fault using Wavelet Transform)

  • 고영훈;김철환;김현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 C
    • /
    • pp.1373-1375
    • /
    • 1999
  • High impedance fault (HIF) is defined as fault the general overcurrent relay can not detect or interrupt. Especially when HIF occur in residential areas, energized high voltage conductor results in fire hazard, equiment damage or personal threat. This paper proposes the model of HIF in transmission line using the ZnO arrester and resistance to be implemented within EMTP. Wavelet transform is efficient and useful for the detection of HIF in power system, because it uses variable windows according to frequency. HIF detection method using wavelet transform can distinguish HIF from similar phenomena like arcfurance load, capacitor bank switching and line switching.

  • PDF

온라인 TSC용 전력 커패시터 뱅크 용량 측정기법에 관한 연구 (An On-line Capacitance Measurement Algorithm of a TSC Power Capacitor Bank)

  • 유진호;박진수;안재영;박일호;천영식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2015년도 제46회 하계학술대회
    • /
    • pp.185-186
    • /
    • 2015
  • TSC는 전력계통의 무효전력 보상을 위한 SVC 시스템의 주요 장치이다. 본 논문에서는 TSC의 커패시터 뱅크의 열화 및 고장진단에 활용할 수 있는 커패시터 용량 측정 기법을 제안한다. 제안한 커패시터 용량 측정 기법은 시간영역 해석 기법으로서 커패시터의 전압 및 전류 신호에 포함된 고조파 및 잡음, 주파수 변동, 과도 상태 전이 등의 왜란에 강인하다.

  • PDF

Unified Power Quality Conditioner for Compensating Voltage Interruption

  • Han, Byung-Moon;Cho, Bo-Hyung;Sul, Seung-Ki;Kim, Jae-Eon
    • Journal of Electrical Engineering and Technology
    • /
    • 제1권4호
    • /
    • pp.503-512
    • /
    • 2006
  • This paper proposes a new configuration for the Unified Power Quality Conditioner, which has a DC/DC converter with super-capacitors for energy storage. The proposed UPQC can compensate the reactive power, harmonic current, voltage sag and swell, voltage imbalance, and voltage interruption. The performance of the proposed system was analyzed through simulations with PSCAD/EMTDC software. The feasibility of system implementation is confirmed through experimental works with a prototype. The proposed UPQC has ultimate capability to improve the power quality at the point of installation on power distribution systems and industrial power systems.

고자장 펄스마그네토미터 구성 및 희토류 영구자석의 자성측정 (Construction of a Pulsed Field Magnetometer and Magnetic Properties Measurement of Rare Earth Permanent Magnets)

  • 김윤배;우병칠;박포규;김만중;김택기
    • 한국자기학회지
    • /
    • 제7권4호
    • /
    • pp.212-216
    • /
    • 1997
  • 충전에너지 18 kJ의 커패시터뱅크 및 펄스코일에서 생성되는 주기 10.12 ms의 정현감쇄진동형 펄스자장을 이용하여 최대 인가자장 130 kOe의 펄스마그네토미터를 구성하였다. 자성측정은 펄스자장의 첫 번째와 두 번째 정방향 자장파크 사이의 파형을 이용하여 유도법으로 측정하였다. NdFeB 소결자석의 측정에 있어서 와전류에 의한 측정오차, 즉, 직류특성과의 차이가 직경 5 mm 이하의 시편을 사용할 경우 3% 이내인 펄스자장형 자기이력곡선 측정장치를 제작하였다.

  • PDF

광대역 고속 AFC 기법을 적용한 다중 대역 VCO의 설계 (Design of Multi-Band VCO with Fast AFC Technique)

  • 안태원;윤찬근;이원석;문용
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2006년도 하계종합학술대회
    • /
    • pp.983-984
    • /
    • 2006
  • Multi-band VCO with fast response adaptive frequency calibration (AFC) technique is designed in 1.8V $0.18{\mu}m$ CMOS process. The possible operation is verified for 5.8GHz band, 5.2GHz band, and 2.4GHz band using the switchable L-C resonators for 802.11a/b/g WLAN applications. To linearize its frequency-voltage gain, optimized multiple MOS varactor biasing technique is used. In order to operate in each band frequency range with reduced VCO gain, 4-bit digitally controlled switched-capacitor bank is used and a wide-range digital logic quadricorrelator is implemented for fast frequency detector.

  • PDF

Design of an Active Tunable Bandpass Filter for Spectrum Sensing Application in the TVWS Band

  • Kim, Dong-Su;Kim, Do-Hyun;Yun, Sang-Won
    • Journal of electromagnetic engineering and science
    • /
    • 제17권1호
    • /
    • pp.34-38
    • /
    • 2017
  • In this paper, we propose an active tunable bandpass filter (BPF) for efficient spectrum sensing in the TV White Space (TVWS) band. By designing a narrow bandwidth, it is possible to improve the sensing probability. The basic circuit configuration involves switching the PIN diode compromising capacitor bank to change the capacitance of the LC resonant circuit. To cover the whole TVWS band effectively, we add a varactor diode, and the bandwidth is set to 25-MHz. We improve the insertion loss by using the active capacitance circuit. The tunable BPF in the TVWS band with a 20-MHz interval is designed to have 11 channels with a bandwidth of 25 MHz and a low insertion loss of 1.7-2.0 dB.

Rotary Arc Gap 스위치에서의 아크 회전속도 측정 (Measurements of the rotating arc speed in Rotary Arc Gap switch)

  • 조주현;임근희;이홍식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 C
    • /
    • pp.2135-2137
    • /
    • 2000
  • Usually arc phenomena are not easily characterized due to unstable behavior very short existence-times, high temperature and the required isolation of measurement instruments. This paper presents some arc-behaviors in a rotary arc gap-switch(RAG) using a 500kJ capacitor bank. It includes the speed variations of the rotating arc, the impacts of the oscillating current on the arc initiations and re-ignitions. Changes in the arc-dimension with respect to time and current magnitudes are also analyzed.

  • PDF