• Title/Summary/Keyword: Capacitance to Voltage Converter

Search Result 126, Processing Time 0.024 seconds

Duplex Pulse Frequency Modulation Mode Controlled Series Resonant High Voltage Converter for X-Ray Power Generator

  • Chu Enhui;Ogura Koki;Moisseev Serguei;Okuno Atsushi;Nakaoka Mutsuo
    • Proceedings of the KIPE Conference
    • /
    • 2001.10a
    • /
    • pp.295-300
    • /
    • 2001
  • A variety of high voltage DC power supplies employing the high frequency inverter are difficult to achieve soft switching considering a quick response and no overshoot response under the wide load variation ranges which are used in medical-use x-ray high voltage generator from 20kV to 150kV in the output voltage and from 0.5mA to 1250mA, respectively. The authors develops soft switching high voltage DC power supply designed for x-ray power generator applications, which uses series resonant inverter circuit topology with a multistage voltage multiplier instead of a conventional high voltage diode rectifier connected to the second-side of a high-voltage transformer with a large turn ratio. A constant on-time dual mode frequency control scheme operating under a principle of zero-current soft switching commutation is described. Introducing the multistage voltage multiplier, the secondary transformer turn-numbers and stray capacitance of high-voltage transformer is effective to be greatly reduced. It is proved that the proposed high-voltage converter topology with dual mode frequency modulation mode control scheme is able to be the transient response and steady-state performance in high-voltage x-ray tube load. The effectiveness of this high voltage converter is evaluated and discussed on the basis of simulation analysis and observed data in experiment.

  • PDF

Photovoltaic Generation by Parallel Driving of Modified Buck-boost Converter (변형된 승강압 컨버터의 병렬구동에 의한 태양광발전)

  • Lee Hee-Chang;Park Sung-Jun;Park Soo-Sik;Moon Chae-Joo;Lee Man-Hyung;Kim Jong-Dal
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.9 no.5
    • /
    • pp.457-466
    • /
    • 2004
  • In this paper, a modified converter is presented and analyzed to use as a photovoltaic converter. And also a new parallel driving scheme is proposed to increase output power and to reduce the output voltage ripple. The ratio of the output to the input voltage of the modified converter is equal to that of the boost converter. The difference between both converters is the composition of output terminal. Owing to the discrepancy, a working voltage of the output capacitor of the modified converter becomes lower, thus the capacitance value of the capacitor can be smaller than that of the boost converter. The proposed parallel driving is based on the modified converter and a current-mode-control method. It gives a good solution for alleviating the current sharing unbalance problem of conventional parallel operations. It reduces the output voltage ripple by means of increasing the equivalent switching frequency without additional switching losses. The validity of the proposed parallel driving strategy is verified through computer-aided simulations and experimental results.

Frequency Analysis Method Based Fault Diagnosis of an Electrolytic Capacitor for Voltage Smoothing (주파수 분석기법을 이용한 전압 평활용 전해 커패시터의 고장진단)

  • Shon, Jin-Geun;Kim, Jin-Sik
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.58 no.2
    • /
    • pp.207-213
    • /
    • 2009
  • Electrolytic capacitors have been widely used in power electronics system because of the features of large capacitance, small size, high-voltage, and low-cost. Electrolytic capacitors, which is most of the time affected by aging effect, plays a very important role for the power electronics system quality and reliability. Therefore it is important to estimate the parameter of an electrolytic capacitor to predict the failure. This paper proposed a novel fault diagnosis method of an electrolytic capacitor used for voltage smoothing in boost DC converter. The equivalent series resistance(ESR) of electrolytic capacitor estimated from FFT result of filtered waveform of capacitor voltage/current. Main advantage of the proposed method include circuit simplicity and easy implementation. Simulation and experimental results are shown to verify the performance of the proposed method.

High Efficiency Resonant Asymmetrical Half-Bridge Flyback Converter (고효율 공진형 비대칭 하프브리지 플라이백컨버터)

  • Jeong, Gang-Youl;Yoo, Doo-Hee
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.4
    • /
    • pp.81-94
    • /
    • 2010
  • This paper presents a high efficiency resonant asymmetrical half-bridge flyback converter. The primary half-bridge circuit of the converter operates by a soft-switching type using the asymmetrical pulse-width modulation (PWM) method with the resonant capacitance and transformer leakage inductance. The secondary flyback circuit of the proposed converter utilizes a synchronous rectifier, which operates by a new voltage-driven method with a simple drive circuit. Thus the proposed converter improves the total efficiency. This paper explains the operational principle of the proposed converter by each mode and shows the converter design consideration and a design example for the prototype converter, respectively. After that, the proposed simple driving technique of the synchronous rectifier by a voltage-driven method is explained, briefly. The designed prototype converter has wide input voltage (AC $V_{in,rms}$=75~265[V]), 5[V] DC output voltage, and 100[W] output power. To verify the excellent performance of the proposed converter, the designed prototype is implemented and experimented. The good performance of the proposed converter is shown through the experimental results.

Study of AC/DC Resonant Pulse Converter for Energy Harvesting (에너지 획득을 위한 AC/DC 공진형 펄스 컨버터의 연구)

  • Ngo Khai D.T.;Chung Gyo-Bum
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.10 no.3
    • /
    • pp.274-281
    • /
    • 2005
  • A new resonant pulse converter for energy harvesting is proposed. The converter transfers energy from a low-voltage AC current to a battery. The low-voltage AC current source is an equivalent of the piezoelectric generator, which converts the mechanical energy to the electric energy. The converter consists of a full-bridge rectifier having four N-type MOSFETs and a boost converter haying N-type MOSFET and P-type MOSFET instead of diode. Switching of MOSFETs utilizes the capability of the $3^{rd}$ regional operation. The operational principles and switching method for the power control of the converter are investigated with the consideration of effects of the parasitic capacitances of MOSFETs. Simulation and experiment are performed to prove the analysis of the converter operation and to show the possibility of the $\mu$W energy harvesting.

A Study on Reactor Capacitance Estimation Algorithm and 5kW Plasma Power Supply Design for Linear Output Control of Wide Range (넓은 범위의 선형 출력 제어를 위한 5kW 플라즈마 전원장치 설계 및 반응기 커패시턴스 추정 알고리즘의 관한 연구)

  • Noh, Hyun-Kyu;Lee, Jun-Young;Kim, Min-Jea
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.21 no.6
    • /
    • pp.514-524
    • /
    • 2016
  • This work suggests a study on 5 kW plasma power supply design and reactor capacitance estimation algorithm for a wide range of linear output control to operate a plasma reactor. The suggested study is designed to use a two-stage circuit and control the full-bridge circuit of the two-stage circuit using the buck converter output voltage of the single-stage circuit. The switching frequency of the full-bridge circuit is designed to operate through high-frequency switching and obtain maximum output using LC parallel resonance. Soft switching technique(ZVS) is used to reduce the loss caused by high-frequency switching, and duty control of the buck converter is applied to control a wide range of linear output. The internal capacitance of the reactor cannot easily be extracted, and thus, the reactor cannot be operated in an optimized resonant state. To address this issue, this work designs the internal capacitance of the reactor such that estimations can be performed with the developed reactor capacitance estimation algorithm applied to the internal capacitance of the reactor. A 5 kW plasma power supply is designed for a wide range of linear output control, and the validity of the study on the reactor capacitance estimation algorithm is verified.

A CW $CO_2$ Laser Using a High Voltage Dc-dc Converter with Half-bridge Resonant Inverter and Cockroft-Walton Multiplier

  • Chung, Hyun-Ju;Joung, Jong-Han;Kim, Geun-Young;Min, Byoung-Dae;Kim, Hee-Je
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • v.3C no.4
    • /
    • pp.123-129
    • /
    • 2003
  • We propose a high voltage dc-dc converter for a CW (continuous wave) $CO_2$ laser system using a current resonant half-bridge inverter and a Cockcroft-Walton circuit. This high voltage power supply includes a 2-stage voltage multiplier driven by a regulated half-bridge series resonant inverter. The inverter drives a step-up transformer and the secondary transformer is applied to the voltage multiplier. It is highly efficient because of the reduced amount of switching losses by virtue of the current resonant half-bridge inverter, and also due to the small size, low parasitic capacitance in the transformer stage owing to the low number of winding turns of the step up secondary transformer combined with the Cockroft-Walton circuit. We obtained a maximum laser output power of 44 W and a maximum system efficiency of over 16%.

Implement of Constant-Frequency-Controled Zero-Voltage-Switching Converter-fed DC Motor Drive for Low Power Loss (직류 전동기의 저손실 구동을 위한 일정 주파수 제어형 영전압 스위칭 변환기의 구현)

  • Ko, Moon-Ju;Park, Jin-Hong;Han, Wan-Ok;Lee, Sung-Paik
    • Proceedings of the KIEE Conference
    • /
    • 1998.07f
    • /
    • pp.2148-2150
    • /
    • 1998
  • This paper proposes a constant frequency controlled zero voltage switching method that can reduce switching losses caused by emf on inductance in DC motor. The zero voltage switching method is used more than a zero current switching method because of reducing switching losses by capacitance of depletion region of MOSFET. To simplify the controller circuit, we propose constant frequency controlled zero voltage switching method in the paper. The control method is more stable than a variable frequency control method because it can optimize bandwidth of a closed-loop and reactances. Therefore, we construct a constant frequency controlled zero voltage switching converter and improve zero switching losses in high switching frequency. In the process, we can control low-losses in full range on variable voltage and load. We simulate the proposed converter with P-SPICE and compare results obtained through the experiment.

  • PDF

A Study on Battery Chargers for the next generation high speed train using the Phase-shift Full-bridge DC/DC Converter (위상전이 풀-브리지 DC/DC 컨버터를 이용한 차세대 고속 전철용 Battery Charger에 관한 연구)

  • Cho, Han-Jin;Kim, Keun-Young;Lee, Sang-Seok;Kim, Tae-Hwan;Won, Chung-Yuen
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2009.05a
    • /
    • pp.384-387
    • /
    • 2009
  • There is an increasing demand for efficient high power/weight auxiliary power supplies for use on high speed traction application. Many new conversion techniques have been proposed to reduce the voltage and current stress of switching components, and the switching losses in the traditional pulse width modulation (PWM) converter. Especially, the phase shift full bridge zero voltage switching PWM techniques are thought must desirable for many applications because this topology permits all switching devices to operate under zero voltage switching(ZVS) by using circuit parasitic components such as leakage inductance of high frequency transformer and power device junction capacitance. The proposed topology is found to have higher efficiency than conventional soft-switching converter. Also it is easily applicable to phase shift full bridge converter by applying an energy recovery snubber consisted of fast recovery diodes and capacitors.

  • PDF

Characteristics Analysis of ZVS-HB Type High Frequency Resonant Inverter According to the Variable Capacitance of the DC Voltage Source Separation Capacitor (직류 전원 분할용 커패시터의 용량 변화에 따른 ZVS-HB형 고주파 공진 인버터의 특성해석)

  • Mun, Chang-Su;Kim, Jong-Hae;Kim, Dong-Hui;O, Seung-Hun;Sim, Gwang-Yeol;Min, Byeong-Jae
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.49 no.5
    • /
    • pp.352-357
    • /
    • 2000
  • This paper presents about an example of circuit design and characteristics of inverter according to the variable capacitance of the DC voltage source separation capacitor used in ZVS-HB type high frequency resonant inverter. The soft switching technology known as ZVS is used to reduce turn off loss at switching. In the event the capacitance of the DC voltage source separation capacitor is varied, the analysis of inverter circuit has generally described by using normalized parameter and operating characteristics have been evaluated in terms of switching frequency and parameters. According to the calculated characteristics value, a method of the circuit designs and operating characteristic of the inverter is also presented in this paper. In addition, this paper proves the validity of theoretical analysis through the experiment. This proposed inverter shows that it can be practically used in future as power source system for the lighting equipment of discharge lamp, DC-DC converter etc.

  • PDF