• Title/Summary/Keyword: Capacitance sensor

Search Result 303, Processing Time 0.034 seconds

The thermal effect on electrical capacitance sensor for two-phase flow monitoring

  • Altabey, Wael A.
    • Structural Monitoring and Maintenance
    • /
    • v.3 no.4
    • /
    • pp.335-347
    • /
    • 2016
  • One of major errors in flow rate measurement for two-phase flow using an Electrical Capacitance Sensor (ECS) concerns sensor sensitivity under temperature raise. The thermal effect on electrical capacitance sensor (ECS) system for air-water two-phase flow monitoring include sensor sensitivity, capacitance measurements, capacitance change and node potential distribution is reported in this paper. The rules of 12-electrode sensor parameters such as capacitance, capacitance change, and change rate of capacitance and sensitivity map the basis of Air-water two-phase flow permittivity distribution and temperature raise are discussed by ANSYS and MATLAB, which are combined to simulate sensor characteristic. The cross-sectional void fraction as a function of temperature is determined from the scripting capabilities in ANSYS simulation. The results show that the temperature raise had a detrimental effect on the electrodes sensitivity and sensitive domain of electrodes. The FE results are in excellent agreement with an experimental result available in the literature, thus validating the accuracy and reliability of the proposed flow rate measurement system.

BURR SIZE MEASUREMENT USING A CAPACITANCE SENSOR

  • Lee, Seoung-Hwan
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.8 no.4
    • /
    • pp.29-37
    • /
    • 1999
  • This paper involves the "on-line" measurement of burrs using a capacitance sensor. A non-contact capacitance gauging sensor is attached to an ultra precision milling machine which was used as a positioning system The setup is used to measure burr profiles along machined workpiece edges. Experimental procedures and results as well as the basic theoretical principles of the capacitance sensor and specifications of related equipment are presented. The proposed scheme is shown to be accurate easy to setup and with minor modifications readily applicable to automatic deburring processes.processes.

  • PDF

The measurement of capacitance of W/O type emulsified fuel using by capacitance sensor (정전용량센서를 이용한 W/O형 유화연료의 정전용량 측정)

  • Cho, Seong-Cheol;Oh, Yang-Hwan;Im, Seok-Yeon
    • Journal of the Korean Applied Science and Technology
    • /
    • v.24 no.4
    • /
    • pp.377-382
    • /
    • 2007
  • We designed capacitance sensor in order to examine characteristics of W/O type emulsified fuel, so it concluded the following conclusions. The capacitance value of emulsified fuel, using with capacitance sensor, increases as water content increases due to the coalescence. When surfactant increases, the capacitance value decreases, the condition of W/O type emulsified fuel was maintained stably. There was revealed the capacitance value difference of W/O type emulsified fuel in in according to water content. We checked the phase separation of emulsified fuel with the capacitance value difference. The surfactant(HLB=5.4) had better stable condition than surfactant(HLB=4.3). Also, we confirmed that two mixture surfactants were better than one surfactant.

Calibrating Capacitance Sensor for Determining Water Content of Volcanic-Ash Soils (화산회토양의 수분함량측정을 위한 Capacitance Soil Moisture Sensor의 Calibration)

  • Moon, Kyung-Hwan;Joa, Jae-Ho;Choi, Kyung-San;Seo, Hyoeng-Ho;Lim, Han-Cheol;Hyun, Hae-Nam
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.44 no.3
    • /
    • pp.331-336
    • /
    • 2011
  • Capacitance soil moisture sensor is extensively used by soil research and irrigation management with its convenience and accuracy. This experiment was conducted to evaluate the acceptability of capacitance soil moisture sensor, named EnviroSCAN made by Sentek Ltd., in Jeju Island where volcanic ash soils are widely distributed, and to calibrate it to various soils with different amount of soil organic matter. For sensor calibration equation of volcanic ash soils, a logarithm function is better than a typical power function of non-volcanic ash soils. So there are possibilities of under evaluated in soil water contents in very wet and very dry conditions by using typical power function with volcanic ash soil areas. We suggested practical coefficients of typical calibration equation for using capacitance sensor in volcanic ash soils, also suggested equations for estimation of them with soil organic matter contents. The measurement of soil water content with a capacitance sensor can be affected by some soil characteristics such as porosity, soil organic matter content, EC, etc. So those factors should be controlled for improving the accuracy of measurement.

The Design and Performance Verification of Collocated Capacitance Sensor for Magnetic Bearing (자기베어링과 공위한 축전센서의 설계 및 성능 평가)

  • 유선중;신동원;김종원
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1994.10a
    • /
    • pp.317-322
    • /
    • 1994
  • The design and performance verification of collocated capacitance sensor system for magnetic bearing is presented. Noncollocation between actuators and sensors may cause unstable rotor behavior. The capacitance sensor is not affected by magnetic field. PCB type capacitance sensor is installed between magnetic bearing polse. so, collocation of sensors and actuators can be achieved. Experiment of sensor's static and dynamic charactistics is conducted. Modeling of the rotor system supported by magnetic bearing is made. And performance comparison between simulation and experiment is showed.

  • PDF

Multi-point Flexible Touch Sensor Based on Capacitor Structure Using Thin Copper-Plated Polyimide Film for Textile Applications

  • Lee, Junheon;Kim, Taekyeong
    • Textile Coloration and Finishing
    • /
    • v.31 no.2
    • /
    • pp.65-76
    • /
    • 2019
  • A multi-point touch input sensor having different sizes or different capacitance touch points connected by only one pair of signal transmission lines was fabricated using a polyimide film coated with a thin copper plate. The capacitance increases with the decrease in the number of sheets of fabric spacers placed between the two sheets of the polyimide film. Therefore, the touch input sensor could be manufactured without fabric spacers, which was possible by the action of the polyimide film as a dielectric material in the capacitor. On the multi-point touch sensor, higher capacitance was obtained when pressing wider-area touch points with 10mm to 25mm diameter on average. However, the capacitance of a system comprising two sheets of touch sensors was considerably low, causing a serious overlap of the capacitance values according to the data collected from the reliability test. Although the capacitance values could be increased by stacking several sheets of touch sensors, the overlap of data was still observed. After reducing the size of all touch points to 10mm and stacking up to eight sheets of sensors, reliable and consistent capacitance data was obtained. Five different capacitance signals could be induced in the sensors by pushing touch points simultaneously.

Fabrication of capacitance sensor for real time harmful substance mass fraction mesurement (유독물질 질량분율 실시간 측정용 정전용량센서 제작)

  • Kim, Young-Su;Oh, Jeoung Seok
    • 한국연소학회:학술대회논문집
    • /
    • 2014.11a
    • /
    • pp.337-338
    • /
    • 2014
  • In this study, a method of using a capacitance sensor was investigated as a means to measure the mass fraction of a type of harmful substance. Using MEMS process, we developed a capacitance sensor and studied the real time mass fraction with harmful substance mixture liquid.

  • PDF

Electrical and Physical Properties of Sheath-core Type Conductive Textile Sensor with Home-Textile (Sheath-core 구조 전도사 섬유센서의 Home-Textile 적용을 위한 전기·물리학적 특성연구)

  • Cho, Kwang-Nyun;Jung, Hyun-Mi
    • Fashion & Textile Research Journal
    • /
    • v.16 no.1
    • /
    • pp.145-152
    • /
    • 2014
  • The usage of textile-based sensors has increased due to their many advantages (compared to IT sensors) when applied to body assessment and comfort. Textile-based sensors have different detecting factors such as pressure, voltage, current and capacitance to investigate the characteristics. In this study, textile-based sensor fabrics with sheath-core type conductive yarns were produced and the relationship between capacitance changes and applied load was investigated. The physical and electric properties of textile-based sensor fabrics were also investigated under various laminating conditions. A textile based pressure sensor that uses a sheath-core conductive yarn to ensure the stability of the pressure sensor in the textile-based sensor (the physical structure of the reaction characteristic of the capacitance) is important for the stability of the initial value of the initial capacitance value outside the characteristic of the textile structural environment. In addition, a textile based sensor is displaced relative to the initial value of the capacitance change according to pressure changes in the capacitance value of the sensor due to the fineness of the high risk of noise generation. Changing the physical structure of the fabric through the sensor characteristic of the pressure sensor via the noise generating element of laminating (temperature, humidity, and static electricity) to cut off the voltage output element to improve the data reliability could be secured.

FE and ANN model of ECS to simulate the pipelines suffer from internal corrosion

  • Altabey, Wael A.
    • Structural Monitoring and Maintenance
    • /
    • v.3 no.3
    • /
    • pp.297-314
    • /
    • 2016
  • As the study of internal corrosion of pipeline need a large number of experiments as well as long time, so there is a need for new computational technique to expand the spectrum of the results and to save time. The present work represents a new non-destructive evaluation (NDE) technique for detecting the internal corrosion inside pipeline by evaluating the dielectric properties of steel pipe at room temperature by using electrical capacitance sensor (ECS), then predict the effect of pipeline environment temperature (${\theta}$) on the corrosion rates by designing an efficient artificial neural network (ANN) architecture. ECS consists of number of electrodes mounted on the outer surface of pipeline, the sensor shape, electrode configuration, and the number of electrodes that comprise three key elements of two dimensional capacitance sensors are illustrated. The variation in the dielectric signatures was employed to design electrical capacitance sensor (ECS) with high sensitivity to detect such defects. The rules of 24-electrode sensor parameters such as capacitance, capacitance change, and change rate of capacitance are discussed by ANSYS and MATLAB, which are combined to simulate sensor characteristic. A feed-forward neural network (FFNN) structure are applied, trained and tested to predict the finite element (FE) results of corrosion rates under room temperature, and then used the trained FFNN to predict corrosion rates at different temperature using MATLAB neural network toolbox. The FE results are in excellent agreement with an FFNN results, thus validating the accuracy and reliability of the proposed technique and leads to better understanding of the corrosion mechanism under different pipeline environmental temperature.

A Study on a Capacitance Displacement Sensor for the Ultraprecision Measurement (초정밀 측정용 정전용량 변위센서에 관한 연구)

  • An, Hyung-Jun;Jung, Yoon;Jung, Sung-Chun;Jang, In-Bae;Han, Dong-Chul
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1996.11a
    • /
    • pp.291-295
    • /
    • 1996
  • This paper discusses several design factors of a capacitance displacement sensor with a numerical method and several experiments and describes guide lines of the design of this type sensor. We introduce the charge density method for the analysis of this type sensor, which has feasible accuracy and efficiency. The analysis of this type sensor with the charge density method agrees with displacement sensitivity experiments of a circular plate capacitance sensor with the sensor amp based In the charge transfer principle.

  • PDF