• 제목/요약/키워드: Cantilever fixed partial denture

검색결과 12건 처리시간 0.03초

Influence of the amount of tooth surface preparation on the shear bond strength of zirconia cantilever single-retainer resin-bonded fixed partial denture

  • Sillam, Charles-Ellie;Cetik, Sibel;Ha, Thai Hoang;Atash, Ramin
    • The Journal of Advanced Prosthodontics
    • /
    • 제10권4호
    • /
    • pp.286-290
    • /
    • 2018
  • PURPOSE. Conventional resin-bonded fixed partial dentures (RBFPDs) are usually made with a two-retainer design. Unlike conventional RBFPDs, cantilever resin-bonded fixed partial dentures (Cantilever RBFPDs) are, for their part, made with a single-retainer design. The aim of this study was to compare the effect of tooth surface preparation on the bond strength of zirconia cantilever single-retainer RBFPDs. The objective is to evaluate the shear bond strength of these single-retainer RBFPDs bonded on 3 different amount of tooth surface preparation. MATERIALS AND METHODS. Thirty extracted bovine incisors were categorized to 3 groups (n=10), with different amounts of tooth surface preparations. Teeth were restored with single-retainer RBFPDs with different retainer surfaces: large retainer of $32mm^2$; medium retainer of $22mm^2$; no retainer and only a proximal connecting box of $12mm^2$. All RBFPDs were made of zirconia and were bonded using an adhesive system without adhesive capacity. Shear forces were applied to these restorations until debonding. RESULTS. Mean shear bond strength values for the groups I, II, and II were $2.39{\pm}0.53MPa$, $3.13{\pm}0.69MPa$, and $5.40{\pm}0.96MPa$, respectively. Statistical analyses were performed using a one-way ANOVA test with Bonferroni post-hoc test, at a significance level of 0.001. Failure modes were observed and showed a 100% adhesive fracture. CONCLUSION. It can be concluded that the preparation of large tooth surface preparation might be irrelevant. For zirconia single-retainer RBFPD, only the preparation of a proximal connecting box seems to be a reliable and minimally invasive approach. The differences are statistically significant.

An implant-supported removable partial denture for a patient with post-inflammatory scar contracture caused by burn complications: a clinical report

  • Kim, Jee-Hwan;Lee, Jae-Hoon
    • The Journal of Advanced Prosthodontics
    • /
    • 제4권1호
    • /
    • pp.57-59
    • /
    • 2012
  • The scars and contracture around the oral-facial region may cause difficulty in prosthodontic treatment to restore esthetics and function for the patients, who suffered severe burns. This article presents a technique that uses a fixed partial denture prepared with a conventional milling technique and an attachment to support anterior cantilever removable partial denture, thereby providing a more esthetically acceptable and functional result.

2-unit cantilever 레진접착성 가공의치 (resin-bonded fixed partial denture) 임상의 현재 (CLINICAL PERSPECTIVES ON 2-UNIT CANTILEVERED RESIN-BONDED FIXED PARTIAL DENTURE)

  • 이양진;조리라;박찬진
    • 대한치과보철학회지
    • /
    • 제41권1호
    • /
    • pp.81-88
    • /
    • 2003
  • Resin-bonded bridge has been an alternative to conventional bridge, since resin-bonded bridge has many attractive advantages such as minimal tooth preparation, short chair time and low cost over conventional bridge. Unfortunately, however, it was reported that resin-bonded bridge showed high failure rate from debonding of retainer in spite of consecutive advances in preparation and materials. And it was shown that multiple abutments were more likely to fail. The majority of debonding failure was considered due to the mobility of the abutment during function. In this view, recently, modification in resin-bonded bridge design was tried. Single retainer, single pontic. 2-unit cantilevered resin-bonded bridge was applied to clinical performance and was shown as retentive or more retentive than fixed-fixed type resin-bonded bridge. This was consistent with the results of studies in 2-unit cantilevered resin-bonded bridges made with all ceramic, In-ceram. The purpose of this article was to overview principles of design and to analyze clinical results of 2-unit cantilevered resin-bonded bridge in comparison with the reports of fixed-fixed resin-bonded bridge.

적합도에 따른 ITI 임플란트 지지 고정성 국소의치의 삼차원 유한요소 분석 (Three Dimensional Finite Element Analysis on ITI Implant Supported Fixed Partial Dentures with Various Fitting Accuracy)

  • 최민호;이일권;김유리;조혜원
    • 구강회복응용과학지
    • /
    • 제22권1호
    • /
    • pp.75-87
    • /
    • 2006
  • The purpose of this study was to investigate the effects of prostheses misfit, cantilever on the stress distribution in the implant components and surrounding bone using three dimensional finite element analysis. Two standard 3-dimensional finite element models were constructed: (1) 3 ITI implant supported, 3-unit fixed partial denture and (2) 3 ITI implant supported, 3-unit fixed partial denture with a distal cantilever. variations of the standard finite element models were made by placing a $100{\mu}m$ or $200{\mu}m$ gap between the fixture, the abutment and the crown on the second premolar and first molar. Total 14 models were constructed. In each model, 244 N of vertical load and 244 N of $30^{\circ}$ oblique load were placed on the distal marginal ridge of the distal molar. von Mises stresses were recorded and compared in the crowns, abutments, crestal compact bones, and trabecular bones. The results were obtained as follows: 1. In the ITI implant system, cement-retained prostheses showed comparatively low stress distributions on all the implant components and fixtures regardless of the misfit sizes under vertical loading. The stresses were increased twice under oblique loading especially in the prostheses with cantilever, but neither showed the effects of misfit size. 2. Under the oblique loading and posterior cantilever, the stresses were highly increased in the crestal bones around ITI implants, but effects of misfit were not shown. Although higher stresses were shown on the apical portion of trabecular bones, the effects by misfit were little and the stresses were increased by the posterior cantilever. 3. When the cement loss happened in the ITI implant supported FPD with misfit, the stresses were increased in the implant componets and supporting structures.

Stress analysis of anterior cantilever bridge

  • Yang, Hong-So;Ku, Chul-Whoi
    • 대한치과보철학회지
    • /
    • 제38권3호
    • /
    • pp.283-290
    • /
    • 2000
  • State ment of Problems. Although some clinicians report long-term success with fixed partial denture (FPD) that contain cantilever pontic, the use of cantilever FPDs may be hazardous because of unfavorable leverages during mastication. Purpose of Study. This study aims to compare the stress induced in the periodontium with normal and reduced bone support, and to analyze the stress distribution patterns of anterior cantilevered FPDs using the finite element method. Results. Cantilever bridge with a reduced bone level generated the highest peak stresses in the periodontium. In the models of reduced bone support, a cantilever bridge exhibited the great-est mobility and a 3-unit fixed restorations induced the smallest mobility of canine. The highest peak stress level of a 3-unit bridge in the periodontium is similar to the unrestored situation. But stress distribution in the bone is modified. Conclusion. In reduced bone support, a cantilever bridge exhibited the greatest mobility and stress.

  • PDF

임플랜트 지지 고정성 국소의치의 임상적, 방사선학적 평가 (CLINICAL AND RADIOGRAPHICAL EVALUATION OF IMPLANT-SUPPORTED FIXED PARTIAL PROSTHESES)

  • 서지영;심준성;이재훈;이근우
    • 대한치과보철학회지
    • /
    • 제44권4호
    • /
    • pp.394-404
    • /
    • 2006
  • Statement of problem: A conventional 3-unit fixed partial denture design with a pontic between two retainers is the most commonly used. However in cases where the mental nerve is in close proximity to the second premolar, a cantilever design can be considered. As such, logical and scientific evidence is lacking for the number and position of implants to be placed for partially edentulous patients, and no clear-cut set of treatment principles currently exist. Purpose : The purpose of this study was to evaluate prognosis of implant-supported fixed partial dentures and to compare changes in bone level which may rise due to the different factors. Material and method : The present study examined radiographical marginal bone loss in patients treated with implant-supported fixed partial dentures (87 prostheses supported by 227 implants) and evaluated the influence of the span of the pontic, type of the opposing dentition. Clinical complications were studied using a retrospective method. Within the limitation of this study. the following result were drawn Result, 1. Seven of a total of 227 implants restored with fixed prostheses failed, resulting in a 96.9% success rate. 2. Complications encountered during recall appointments included dissolution of temporary luting agent (17 cases), porcelain fracture (8 cases), loosened screws (5 cases), gingival recession (4 cases), and gingival enlargement (1 case). 3. Marginal bone loss, 1 year after prosthesis placement, was significant(P<0.05) in the group that underwent bone grafting, however no difference in annual resorption rate was observed afterwards. 4. Marginal bono loss, 1 year post-placement, was greater in cantilever-type prostheses than in centric pontic protheses (P<0.05). 5. Marginal bone loss was more pronounced in posterior regions compared to anterior regions (P<0.05). 6. The degree of marginal bone loss was proportional to the length of the pontic (P<0.05). Conclusion: The success rate of implant-supported fixed partial dentures, including marginal bone loss, was satisfactory in the present study. Factors influencing marginal bone loss included whether bone graft was performed, location of the pontic (s), location of the surgical area in the arch pontic span. Long-term evaluation is necessary for implant-supported fixed partial dentures, as are further studies on the relationship between functional load and the number of implants to be placed.

가공의치(架工義齒)에 작용(作用)하는 Stress에 관(關)한 광탄성학적(光彈性學的) 분석(分析) (Photoelastic Stress Analysis of Fixed Partial Dentures)

  • 조원행
    • 대한치과보철학회지
    • /
    • 제18권1호
    • /
    • pp.15-35
    • /
    • 1980
  • The purpose of this study was to investigate stresses in the various components of fixed partial dentures restoring the posterior teeth of the lower jaw, and to measure quantitatively the effects of certain modifications in structural design on the stresses in the restorations using two-dimensional photoelasticity. Two-dimensional photoelastic methods were used in this study. Several models of fixed partial dentures were constructed. Shoulder less margins and anatomic occlusal reduction were incorporated in Model 1. Rounded shoulders and flat occlusal reduction were incorporated in Model 2, while Model 3 was a cantilever fixed partial denture. Other similar fixed partial dentures were constructed with V and U notches deliverately included in the region of the fixed joints for comparative reasons. The birefringent materials used in this study were PSM-1 and PSM-5 in standard sheets. PSM-1 was used for constructing the substructure, and PSM-5 was used in making the components of the fixed partial dentures. The two materials were used in the construction of composite photoelastic models. Improved artificial stone was used to represent dental cement in luting the composite photoelastic models. Static loading procedures were used at preplanned sites to represent occlusal loads in the mouth. 35 mm color and B/W film were used to record isochromatics in accordance with photoelastic procedures. Data reduction was performed using the grid method, which helped in, the mathematical integration procedure (Shear difference method) to separate the principal stresses. The results were as follows. 1. Fixed partial dentures do not function in bending as a symmetrical beam. Alternate areas of tension and compression were demonstrated when multiple contact loading was used. 2. The weakest part in posterior fixed partial dentures is the fixed joint. 3. (1) Models I and modified Model I were loaded on the pontic using a 50 pound vertical static load. The shear stress near the posterior fixed joint in Model 1 (U notches) was+129.4 p.s.i., and at the same fixed joint in modified Model 1 (V notches) was+239.4 p.s.i. The concentration of stress in fixed joint was reduced by 50% when U notches replaced the V notches. (2) Modified Model 2 was loaded using a multiple contact loader at a total load of 125 pounds. The difference between the principal stresses (${\sigma}_1-{\sigma}_2$), shear stress, at the V notches was+600 p.s.i., and at the U notches was+3l7 p.s.i. The shear stress was reduced by 50% when U notches replaced the V notches. V-grooves at the fixed joints should be avoided, and should be replaced by regular shaped U-grooves. 4. Cantilever fixed partial dentures had much higher stresses at the fixed joint than fixed partial dentures that were attached at both ends.

  • PDF

상악 전치부 고정성 보철물 수복 시 임시 임플란트를 이용한 임시보철물의 유지력 증가 증례보고 (Reinforcing the retention of provisional restoration using provisional implant on maxillary anterior region: clinical case report)

  • 김창대;문홍석;정문규;이재훈
    • 대한치과보철학회지
    • /
    • 제51권3호
    • /
    • pp.221-225
    • /
    • 2013
  • 임시 보철물의 적절한 관리는 보철의 성공에 있어서 중요한 요소이다. 상악 전치 결손부 임시 보철물은 장경간의 결손부가 존재하거나, 타원형의 악궁을 가진 환자에서 자주 탈락하게 된다. 이는 상악 전치부가 구치부에 비해서 수평적인 힘에 더 많이 노출되며, 부가적으로 전방 캔틸레버 효과가 임시 보철물의 유지를 저해하고, 상악 전치부 임시 보철물은 하악의 기능 운동시 적절한 전방 유도를 제공하여야 하기 때문이다. 또한 임시 보철물의 최대 감합위에서 교합접촉은 지점선의 반대편에 위치하게 되어 그 자체로 임시 보철물의 탈락을 야기한다. 본 증례에서는 임시 임플란트를 이용하여 상악 전치부 보철물에 대한 전술한 유해 작용을 피할 수 있었고, 발치 후 치유기간 동안 환자에게 편안함과 만족감을 부여하였으므로 이를 보고하는 바이다.

내부연결 임플란트의 보철 수복 후 성공률에 미치는 위험요소에 관한 10년간의 후향적 연구 (A 10-year retrospective study on the risk factors affecting the success rate of internal connection implants after prosthetic restoration)

  • 이서인;김민정
    • 대한치과보철학회지
    • /
    • 제61권2호
    • /
    • pp.113-124
    • /
    • 2023
  • 목적: 본 연구의 목적은 임플란트 보철물의 종류 및 특성과 생존율 분석을 통해 성공률을 높이는데 도움이 되는 데에 있다. 대상 및 방법: 원광대학교 치과대학 산본치과병원에서 2011~2020년에 식립한 임플란트 중 한 명의 보철전문의에 의해 수복된 사례에 대하여 그 특성과 실패에 대한 상관관계 등을 조사하였다. 실패의 원인은 골유착 실패, 임플란트주위염, 고정체 파절, 지대주 파절, 나사 파절, 나사 풀림, 보철물 파절, 보철물 유지력 상실 등으로 분류했다. 보철방식, 캔틸레버 여부, 식립 위치 등과 임플란트 실패와의 연관성을 분석했다. 결과 분석은 SPSS ver 25.0 (IBM, Chicago, IL, USA)을 이용하여 Chi-square test, Kaplan-Meier 생존분석 등을 통하여 도출했다. 결과: 총 2587개의 임플란트가 식립되었으며, 그 중 1141개의 임플란트가 단일관(Single Crown)으로, 1446개의 임플란트가 고정성 국소의치(Fixed Partial Denture)로 수복되었고 누적생존율은 88.1%이었다. SC의 성공률은 86.2% (984개), FPD의 성공률은 89.6% (1295개)로 통계적으로 유의한 차이를 보였으며 그 중 유의한 차이가 있었던 요인은 지대주 파절, 나사 파절, 나사 풀림 등이었다 (P < .05). 결론: 10년간의 추적조사 결과 생물학적인 요인보다는 생역학적인 요인으로 인한 실패가 더 많이 발생했고 임플란트의 성공률은 보철방식 별로 상이했으며 영향을 미치는 요인도 상이했다. 추후 임플란트의 성공에 관한 추가적인 연구가 더 필요할 것이다.