• Title/Summary/Keyword: Cancer registration

Search Result 168, Processing Time 0.019 seconds

Analysis of studies on Bojungikgi-tang(Buzhongyiqi-tang) to establish the fundament for Evidence Based Medicine (EBM) (EBM 기반구축을 위한 보중익기탕 실험 연구 분석)

  • Kim, Jung-Hoon;Lee, Jun-Kyoung;Shin, Hyeun-Kyoo
    • Korean Journal of Oriental Medicine
    • /
    • v.17 no.2
    • /
    • pp.135-167
    • /
    • 2011
  • Objective : To establish the fundament for EBM of Traditional Korean Medicine, the papers on Bojungikgitang(Buzhongyiqi-tang) frequently used in medical institutions of Traditional Korean Medicine were analyzed through researching domestic and international papers. Methods : The papers were classified by the registration of domestic or international journals, the year of publishment, experimental fields and the kinds of studies on biological activities. Results : Among 2005 volumes of papers on Bojungikgi-tang(Buzhongyiqi-tang), 219 volumes were selected according to selective criteria. 71 volumes were published in domestic journals, 52 volumes were in Chinese journal, 96 volumes were in Japanese journal. The papers on instrumental analyses reported the quantification of standard compounds of herbal medicines in Bojungikgi-tang(Buzhongyiqi-tang) using HPLC method. The papers on biological activities of Bojungikgi-tang(Buzhongyiqi-tang) showed mainly immune regulation, anti-infection, anti-cancer, gastrointestinal activity, neuropsychiatric regulation, anti-inflammation, hepatoprotection, musculoskeletal regulation. Among biological activities, papers on immume regulation were reported mostly. Conclusions : The efficacy of Bojungikgi-tang(Buzhongyiqi-tang) could be related to immune regulation, gastrointestinal activity, anti-fatigue and further study need to be preceeded to establish the fundament for EBM of Bojungikgitang(Buzhongyiqi-tang).

Rotation Errors of Breast Cancer on 3D-CRT in TomoDirect (토모다이렉트 3D-CRT을 이용한 유방암 환자의 회전 오차)

  • Jung, Jae Hong;Cho, Kwang Hwan;Moon, Seong Kwon;Bae, Sun Hyun;Min, Chul Kee;Kim, Eun Seog;Yeo, Seung-Gu;Choi, Jin Ho;Jung, Joo-Yong;Choe, Bo Young;Suh, Tae Suk
    • Progress in Medical Physics
    • /
    • v.26 no.1
    • /
    • pp.6-11
    • /
    • 2015
  • The purpose of this study was to analyze the rotational errors of roll, pitch, and yaw in the whole breast cancer treated by the three-dimensional radiation therapy (3D-CRT) using TomoDirect (TD). Twenty-patient previously treated with TD 3D-CRT was selected. We performed a retrospective clinical analysis based on 80 images of megavoltage computed tomography (MVCT) including the systematic and random variation with patient setup errors and treatment setup margin (mm). In addition, a rotational error (degree) for each patient was analyzed using the automatic image registration. The treatment margin of X, Y, and Z directions were 4.2 mm, 6.2 mm, and 6.4 mm, respectively. The mean value of the rotational error for roll, pitch, and yaw were $0.3^{\circ}$, $0.5^{\circ}$, $0.1^{\circ}$, and all of systematic and random error was within $1.0^{\circ}$. The errors of patient positioning with the Y and Z directions have generally been mainly higher than the X direction. The percentage in treatment fractions in less than $2^{\circ}$ at roll, pitch, and yaw are 95.1%, 98.8%, and 97.5%, respectively. However, the edge of upper and lower (i.e., bottom) based on the center of therapy region (point) will quite a possibility that it is expected to twist even longer as the length of treatment region. The patient-specific characters should be considered for the accuracy and reproducibility of treatment and it is necessary to confirm periodically the rotational errors, including patient repositioning and repeating MVCT scan.

Analysis of Intrafractional Mass Variabilities Using Deformable Image Registration Program (영상변조 프로그램을 이용한 호흡 위상 간 종양의 움직임 특성 분석)

  • Cho, Jeong-Hee;Kim, Joo-Hoo;Seo, Sun-Youl;Han, Dong-Kyoon
    • Journal of radiological science and technology
    • /
    • v.35 no.2
    • /
    • pp.173-181
    • /
    • 2012
  • The aim of this study is to compare the geometric characteristics of the lung tumor, such as tumor centroid, HU change relative to breath phase, depending on tumor location and adhesion using 4DCT and deformable image registration program (MIMVista). The Y axis change was most significant and the mean Y axis centroid fluctuation was $7.32{\pm}6.88mm$ in lower lung tumor. The mean HU variation in lower lung mass has changed more than other locations, and its mean HU variation was $7.7{\pm}4.97%$ and non-adhered mass was more changed. Correlation for the mass volume between 3DCT and MIP was very high and its coefficient was 0.998. The effect of tumor location, adhesion and diaphragm excursion to geometric uncertainties was analyzed by linear regression model, it was influenced to mass deformation and geometrical variation so much except diaphragm excursion. but intra-fractional and inter-patient's uncertainties were great, so it couldn't find any exact deformation trend.

Development of educational programs for managing medical information utilizing medical data generation and analysis techniques (의료 데이터 발생과 분석기술을 활용한 의료정보관리 교육용 프로그램 개발)

  • Choi, Joonyoung
    • Journal of Digital Convergence
    • /
    • v.15 no.10
    • /
    • pp.377-386
    • /
    • 2017
  • This study has developed a medical information management educational program that can improve the management ability of medical information. The educational medical information management program was developed for 8mnths uing VB. The database utilized the ACCESS Database, which allows learners to easily understand and understand the structure of the data. The learners enter data in the discharge analysis and the cancer registration program and the incomplete program after analyze the medical records. After entering and saving data, medical information management programs can be used to understand and analyze the structure of the database to generate medical information. The educational programs can improve the ability of learners to manage medical information by extracting the necessary data from the database directly through SQL and creating various medical information. However, although the medical information management program is an educational program, there is no evaluation system for the learners program operation. Accordingly, the next studies should develop the assessment system of the medical information management program for learners evaluation.

Development of QA Phantom Prototype for Imaged Based Radiation Treatment System (영상기반 방사선 치료기기를 위한 QA 팬텀 시작품 개발)

  • Chang, Jin-A;Oh, Seoung-Jong;Jung, Won-Kyun;Jang, Hong-Suk;Kim, Hoi-Nam;Kang, Dae-Gyu;Lee, Doo-Hyun;Suh, Tae-Suk
    • Progress in Medical Physics
    • /
    • v.19 no.2
    • /
    • pp.120-124
    • /
    • 2008
  • In this study, we developed the protopype of QA phantom for image QA including an additional component for image based radiation treatment system. The new phantom considered two main parts: Image quality and fusion accuracy. Image quality part included for daily CT number linearity and spatial resolution, and fusion accuracy part designed to simulate a simple translation-rotation setting. The CT scans of the phantom obtained from conventional CT, MVCT of Tomotherapy unit, and both image sets were satisfied the recommendation of spatial resolution. This phantom was simple and efficient for daily imaging QA, and it is important to provide a new concept of verification of image registration.

  • PDF

Effectiveness of Non-Pharmacologic Interventions in Chemotherapy Induced Peripheral Neuropathy: A Systematic Review and Meta-Analysis (항암화학요법 관련 말초신경병증에 적용한 비약물적 중재의 효과: 체계적 문헌고찰 및 메타분석)

  • Oh, Pok-Ja;Kim, You Lim
    • Journal of Korean Academy of Nursing
    • /
    • v.48 no.2
    • /
    • pp.123-142
    • /
    • 2018
  • Purpose: This study was conducted to evaluate the effectiveness of non-pharmacologic interventions in chemotherapy-induced peripheral neuropathy (CIPN). Methods: PubMed, Cochrane Library CENTRAL, EMBASE, CINAHL, and several Korean databases (Until August 2017) were searched. The main search strategy combined terms for peripheral neuropathy and presence of neoplasms. The risk of bias was assessed using the Cochrane's Risk of Bias tool for randomized studies and the Risk of Bias Assessment tool for non-randomized studies. To estimate the effect size, a meta-analysis of the studies was performed using the Rev Man 5.3 program of the Cochrane Library random-effects models were used in the analyses. Results: Twenty-two studies with a total of 954 participants met the inclusion criteria. Of the 22 studies, 12 were used to estimate the effect size of the non-pharmacologic interventions. The non-pharmacologic interventions used in patients with CIPN were exercise, acupuncture, massage, and foot bath. The acupuncture significantly reduced CIPN symptoms and signs (d=-0.71) and CIPN pain (d=-0.73) (p<.001). Massage and foot bath were also effective in reducing CIPN symptoms (d=-0.68; 95% CI=-1.05, -0.30; p<.001; $I^2=19%$).Exercises were effective in improving muscle strength and endurance(d=-0.55) and quality of life (d=-2.96), but they were not significantly effective in improving CIPN. Conclusion: Although these results provide little evidence of the effectiveness of acupuncture, massage, and foot bath in the treatment of CIPN, they suggest that these interventions can reduce CIPN symptoms in patients with cancer. However, the findings of this study should be interpreted with caution as there is a relative lack of data in this field, and additional well-designed studies are needed. PROSPERO registration: CRD42017076278.

Geometric Evaluation of Patient-Specific 3D Bolus from 3D Printed Mold and Casting Method for Radiation Therapy

  • An, Hyun Joon;Kim, Myeong Soo;Kim, Jiseong;Son, Jaeman;Choi, Chang Heon;Park, Jong Min;Kim, Jung-in
    • Progress in Medical Physics
    • /
    • v.30 no.1
    • /
    • pp.32-38
    • /
    • 2019
  • Purpose: The objective of this study is to evaluate the geometrical accuracy of a patient-specific bolus based on a three-dimensional (3D) printed mold and casting method. Materials and Methods: Three breast cancer patients undergoing treatment for a superficial region were scanned using computed tomography (CT) and a designed bolus structure through a treatment planning system (TPS). For the fabrication of patient-specific bolus, we cast harmless certified silicone into 3D printed molds. The produced bolus was also imaged using CT under the same conditions as the patient CT to acquire its geometrical shape. We compared the shapes of the produced bolus with the planned bolus structure from the TPS by measuring the average distance between two structures after a surface registration. Results and Conclusions: The result of the average difference in distance was within 1 mm and, as the worst case, the absolute difference did not exceed ${\pm}2mm$. The result of the geometric difference in the cross-section profile of each bolus was approximately 1 mm, which is a similar property of the average difference in distance. This discrepancy was negligible in affecting the dose reduction. The proposed fabrication of patient-specific bolus is useful for radiation therapy in the treatment of superficial regions, particularly those with an irregular shape.

Quality Reporting of Systematic Review and Meta-Analysis According to PRISMA 2020 Guidelines: Results from Recently Published Papers in the Korean Journal of Radiology

  • Ho Young Park;Chong Hyun Suh;Sungmin Woo;Pyeong Hwa Kim;Kyung Won Kim
    • Korean Journal of Radiology
    • /
    • v.23 no.3
    • /
    • pp.355-369
    • /
    • 2022
  • Objective: To evaluate the completeness of the reporting of systematic reviews and meta-analyses published in a general radiology journal using the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) 2020 guidelines. Materials and Methods: Twenty-four articles (systematic review and meta-analysis, n = 18; systematic review only, n = 6) published between August 2009 and September 2021 in the Korean Journal of Radiology were analyzed. Completeness of the reporting of main texts and abstracts were evaluated using the PRISMA 2020 statement. For each item in the statement, the proportion of studies that met the guidelines' recommendation was calculated and items that were satisfied by fewer than 80% of the studies were identified. The review process was conducted by two independent reviewers. Results: Of the 42 items (including sub-items) in the PRISMA 2020 statement for main text, 24 were satisfied by fewer than 80% of the included articles. The 24 items were grouped into eight domains: 1) assessment of the eligibility of potential articles, 2) assessment of the risk of bias, 3) synthesis of results, 4) additional analysis of study heterogeneity, 5) assessment of non-reporting bias, 6) assessment of the certainty of evidence, 7) provision of limitations of the study, and 8) additional information, such as protocol registration. Of the 12 items in the abstract checklists, eight were incorporated in fewer than 80% of the included publications. Conclusion: Several items included in the PRISMA 2020 checklist were overlooked in systematic review and meta-analysis articles published in the Korean Journal of Radiology. Based on these results, we suggest a double-check list for improving the quality of systematic reviews and meta-analyses. Authors and reviewers should familiarize themselves with the PRISMA 2020 statement and check whether the recommended items are fully satisfied prior to publication.

Development of an Automatic Seed Marker Registration Algorithm Using CT and kV X-ray Images (CT 영상 및 kV X선 영상을 이용한 자동 표지 맞춤 알고리듬 개발)

  • Cheong, Kwang-Ho;Cho, Byung-Chul;Kang, Sei-Kwon;Kim, Kyoung-Joo;Bae, Hoon-Sik;Suh, Tae-Suk
    • Radiation Oncology Journal
    • /
    • v.25 no.1
    • /
    • pp.54-61
    • /
    • 2007
  • [ $\underline{Purpose}$ ]: The purpose of this study is to develop a practical method for determining accurate marker positions for prostate cancer radiotherapy using CT images and kV x-ray images obtained from the use of the on- board imager (OBI). $\underline{Materials\;and\;Methods}$: Three gold seed markers were implanted into the reference position inside a prostate gland by a urologist. Multiple digital image processing techniques were used to determine seed marker position and the center-of-mass (COM) technique was employed to determine a representative reference seed marker position. A setup discrepancy can be estimated by comparing a computed $COM_{OBI}$ with the reference $COM_{CT}$. A proposed algorithm was applied to a seed phantom and to four prostate cancer patients with seed implants treated in our clinic. $\underline{Results}$: In the phantom study, the calculated $COM_{CT}$ and $COM_{OBI}$ agreed with $COM_{actual}$ within a millimeter. The algorithm also could localize each seed marker correctly and calculated $COM_{CT}$ and $COM_{OBI}$ for all CT and kV x-ray image sets, respectively. Discrepancies of setup errors between 2D-2D matching results using the OBI application and results using the proposed algorithm were less than one millimeter for each axis. The setup error of each patient was in the range of $0.1{\pm}2.7{\sim}1.8{\pm}6.6\;mm$ in the AP direction, $0.8{\pm}1.6{\sim}2.0{\pm}2.7\;mm$ in the SI direction and $-0.9{\pm}1.5{\sim}2.8{\pm}3.0\;mm$ in the lateral direction, even though the setup error was quite patient dependent. $\underline{Conclusion}$: As it took less than 10 seconds to evaluate a setup discrepancy, it can be helpful to reduce the setup correction time while minimizing subjective factors that may be user dependent. However, the on-line correction process should be integrated into the treatment machine control system for a more reliable procedure.

Dental Practitioners Self Reported Performance of Tobacco Cessation Counseling Interventions: A Cross Sectional Study

  • Parakh, Abhinav;Megalamanegowdru, Jayachandra;Agrawal, Rohit;Hathiwala, Siddhi;Chandrakar, Mayank;Tiwari, Ram;Veeranna, Thippeswamy
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.14 no.10
    • /
    • pp.6141-6145
    • /
    • 2013
  • Background: The objective of the study was to determine the knowledge, attitude and behaviors of the practicing dentists regarding tobacco cessation counseling (TCC) in Chhattisgarh state and also the barriers that prevent them from doing so. Materials and Methods: The study was conducted among dental practitioners of Raipur district, Chhattisgarh state (India). The sampling frame was registration with the State Dental Council and practicing in Raipur district. A questionnaire was personally administered and the practitioners were given explanations regarding how to complete it. Only descriptive statistics were calculated (SPSS version 16 for Windows). Results: Based on the responding dentists' self reports, 76% were not confident in TCC, 48% did not assume TCC to be their responsibility, 17% considered that it might have a negative impact on their clinical practice, whereas 24% considered it might take away precious time from their practice, 25% considered TCC by dentists to be effective to a considerable extent and 80% considered TCC activities are not effective due to lack of formal training, 69% considered dental clinics as an appropriate place for TCC but 82% thought there must be separate TCC centre and 100% of the dentists wanted TCC training to be a part of practice and that it should be included in dental curriculum. Some 95% of them were of the view that tobacco products should be banned in India and 86% responded that health professionals must refrain from tobacco habits so to act as role models for society. Conclusions: Dental professionals must expand their armamentarium to include TCC strategies in their clinical practice. The dental institutions should include TCC in the curriculum and the dental professionals at the primary and the community health care level should also be trained in TCC to treat tobacco dependence.