• Title/Summary/Keyword: Cancer imaging

Search Result 1,166, Processing Time 0.027 seconds

Use of $^{18}F$-FDG PET/CT in Second Primary Cancer (이차성 원발암에서의 $^{18}F$-FDG PET/CT의 이용)

  • Choi, Joon-Young;Kim, Byung-Tae
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.41 no.3
    • /
    • pp.185-193
    • /
    • 2007
  • This review focuses on the use of $^{18}F-FDG$ PET/CT to evaluate second primary cancers. The emergence of a second primary cancer is an important prognostic factor in cancer patients. The early detection of a second primary cancer and the appropriate treatment are essential for reducing the morbidity and mortality associated with these tumors. Integrated $^{18}F-FDG$ PET/CT, which can provide both the metabolic and anatomic information of a cancer, has been shown to have a better accuracy in oncology than either CT or conventional PET. The whole body coverage and high sensitivity of $^{18}F-FDG$ PET/CT along with its ability to provide both metabolic and anatomic information of a cancer make it suitable for evaluating a second primary cancer in oncology. Whole body $^{18}F-FDG$ PET/CT is useful for screening second primary cancers with a high sensitivity and good positive predictive value. In order to rule out the presence of a second primary cancer or an unexpected metastasis, further diagnostic work-up is essential when abnormal findings indicative of a second primary cancer are found on the PET/CT images. PET/CT is better in detecting a second primary tumor than conventional PET.

Effectiveness of Ultrasonographic Screening for Thyroid Cancer: Round-table Conference in the National Evidence-based Healthcare Collaborating Agency (NECA) in conjunction with the Korean Thyroid Association

  • Shin, Sangjin;Park, Sae Eun;Kim, Soo Young;Hyun, Min Kyung;Kim, Sun Wook;Kwon, Jin Won;Kim, Yeol;Kim, Won Bae;Na, Dong Gyu;Park, Hyun-Ah;Sheen, Seung Soo;Yi, Ka Hee;Chang, Hang-Seok;Cho, Jung Jin;Chung, Jae Hoon
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.12
    • /
    • pp.5107-5110
    • /
    • 2014
  • Background: The incidence rate of thyroid cancer has been increasing worldwide in recent years, and it is also the most prevalent cancer when it comes to the number of patients among Korean women. With it, ultrasonographic screening test has also become very common. However, there is still controversy over the performance of this screening test. Therefore, the National Evidence-based Healthcare Collaborating Agency (NECA) organized a Round-table Conference on the issues regarding ultrasonographic screening for thyroid cancer in Korea. The objective of the conference was mainly about delivering worthwhile information reflecting social value for the current situation, which was based on evidence surrounding thyroid cancer screening that relevant experts investigated and agreed on. The significance of this Round-table Conference lies in the fact that we reviewed the current evidence, and we were able to discuss the social value and future direction for ultrasonographic screening in Korea.

Performance Evaluation of Substitution Radiopharmaceutical according to Restriction of the Radiocolloids in Lymphoscintigraphy (Lymphoscintigraphy에 이용되는 방사성의약품의 사용제한으로 인한 대체 방사성의약품의 성능평가)

  • Seo, Young-Deok;Jeong, Jae-Hun;Moon, Jong-Woon;Yun, Sang-Hyeok;Kim, Yeong-Seok;Kang, Se-Hun;Won, Woo-Jae;Kim, Seok-Ki
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.1
    • /
    • pp.25-29
    • /
    • 2009
  • Purpose: Several radioactive agents were used for lymphoscintigraphy in breast cancer. But recently, due to the change of local radiopharmaceutical licensing policy and discontinuation of supplies from manufacturer, we could not use many radiocolloids such as $^{99m}Tc$-Antimony Trisulfide Colloid, $^{99m}Tc$-Tin Colloid, $^{99m}Tc$-Human Serum Albumin. So it is necessary to use the substitution radiopharmaceutical. Therefore, this study aims to evaluate the performance of substitution radiopharmaceutical ($^{99m}Tc$-Phytate) including the existing radiocolloids and to set up of the appropriate protocol in lymphoscintigraphy. Materials and Methods: For each radiocolloids ($^{99m}Tc$-Antimony Trisulfide Colloid (ASC), $^{99m}Tc$-Tin Colloid (TC), $^{99m}Tc$-Human Serum Albumin (HSA), $^{99m}Tc$-Phytate) were performed the particle size by Zeta Sizer (Nano-ZS) and we compared the radiolabeling time, procedure and acquisition time for each of the radiocolloids (total 200 patients). For the last time, we made an analysis of image for each of the radiocolloids with our previous report (SJ Jang et al, Korean Nucl Med Mol imaging Vol.41, No.6, Dec 2007). Results: The particle size of each radiocolloids showed A.S.C (50 nm), T.C (310 nm), H.S.A (10.8 nm), $^{99m}Tc$-Phytate (499 nm). The labeling and acquisition time for each of the radiocolloids showed no substantial difference. But there is difference of the labeling time for the A.S.C. because the ASC procedure need to boiling process. There were no significant differences among those radiocolloids (p>0.005) in the identification rate (IR), false negative rate (FNR), and negative predictive value (NPV). Conclusions: $^{99m}Tc$-labeled radiocolloids showed equivalent results in lymphoscintigraphy. Therefore, in this exam of each radiocolloids could be applied appropriate protocol in lymphoscintigraphy.

  • PDF

Can Reproductive Characteristics Predict Bladder Cancer in Women with Haematuria?

  • Yavuzcan, Ali;Caglar, Mete;Kayikci, Muhammet Ali;Basaran, Ekrem;Tekin, Ali;Ozdemir, Enver;Dilbaz, Serdar;Ustun, Yusuf;Cam, Haydar Kamil
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.14 no.9
    • /
    • pp.5107-5110
    • /
    • 2013
  • Background: Among women with haematuria, defining individuals under high risk for bladder cancer based on reproductive factors prior to cystoscopy would be of great benefit in the management of this condition. The aim of this study was to compare age and reproductive factors such as menopausal status, parity, age at first delivery and age at the last delivery between women who have haematuria with or without bladder cancer. Materials and Methods: A total of 463 patients underwent diagnostic cystoscopy in D$\ddot{u}$zce University Faculty of Medicine between 1 June 2008 and 1 June 2013. Female patients who presented with persistent microscopic or macroscopic haematuria and underwent standard evaluation for haematuria including urinalysis, urine culture, urine cytology, urinary tract imaging with excretory urography or computerized tomography with contrast enhancement and endoscopic evaluation of the urethra and bladder were included in this study. Exclusion criteria were tobacco use and high risk occupations for bladder cancer such as textile, dry cleaning, painting and etc. Forteen women had hematuria due to benign conditions, and 18 due to bladder cancer. Data were retrospectively retrieved from the medical records of Duzce University Hospital. Results: Patients with haematuria due to benign reasons did not significantly differ from patients who were found to have bladder cancer in terms of age (p=0.28), menopausal status (p=0.29), mean parity (p=0.38), being nulliparous (p=0.57), parity ${\geq}3$ (p=0.22), age ${\leq}18$ years at first delivery (p=1.00), age ${\geq}30$ years at last delivery (p=0.26), age ${\geq}35$ years at last delivery (p=0.23) and percentage of the patients with advanced age (${\geq}65$ years) (p=0.18). Conclusions: It is difficult to predict a high risk for developing bladder cancer in women with haematuria based solely on reproductive factors.

Size-Specific Dose Estimation In the Korean Lung Cancer Screening Project: Does a 32-cm Diameter Phantom Represent a Standard-Sized Patient in Korean Population?

  • Kim, Eun Young;Kim, Tae Jung;Goo, Jin Mo;Kim, Hyae Young;Lee, Ji Won;Lee, Soojung;Lim, Jun-tae;Kim, Yeol
    • Korean Journal of Radiology
    • /
    • v.19 no.6
    • /
    • pp.1179-1186
    • /
    • 2018
  • Objective: The purposes of this study were to evaluate size-specific dose estimate (SSDE) of low-dose CT (LDCT) in the Korean Lung Cancer Screening (K-LUCAS) project and to determine whether CT protocols from Western countries are appropriate for lung cancer screening in Korea. Materials and Methods: For participants (n = 256, four institutions) of K-LUCAS pilot study, volume CT dose index ($CTDI_{vol}$) using a 32-cm diameter reference phantom was compared with SSDE, which was recalculated from $CTDI_{vol}$ using size-dependent conversion factor (f-size) based on the body size, as described in the American Association of Physicists in Medicine Report 204. This comparison was subsequently assessed by body mass index (BMI) levels (underweight/normal vs. overweight/obese), and automatic exposure control (AEC) adaptation (yes/no). Results: Size-specific dose estimate was higher than $CTDI_{vol}$ ($2.22{\pm}0.75mGy$ vs. $1.67{\pm}0.60mGy$, p < 0.001), since the f-size was larger than 1.0 for all participants. The ratio of SSDE to $CTDI_{vol}$ was higher in lower BMI groups; 1.26, 1.37, 1.43, and 1.53 in the obese (n = 103), overweight (n = 70), normal (n = 75), and underweight (n = 4), respectively. The ratio of SSDE to $CTDI_{vol}$ was greater in standard-sized participants than in large-sized participants independent of AEC adaptation; with AEC, SSDE/$CTDI_{vol}$ in large- vs. standard-sized participants: $1.30{\pm}0.08$ vs. $1.44{\pm}0.08$ (p < 0.001) and without AEC, $1.32{\pm}0.08$ vs. $1.42{\pm}0.06$ (p < 0.001). Conclusion: Volume CT dose index based on a reference phantom underestimates radiation exposure of LDCT in standard-sized Korean participants. The optimal radiation dose limit needs to be verified for standard-sized Korean participants.

Magnetic Resonance Imaging Factors Predicting Re-excision in Breast Cancer Patients Having Undergone Conserving Therapy (유방보존술을 시행받는 유방암환자에서 재절제 예측의 자기공명영상소견)

  • Jang, Mijung;Kim, Sun Mi;Yun, Bo La;Kim, Sung-Won;Kang, Eun Young;Park, So Yeon;Kim, Jee Hyun;Kim, Yeongmi;Ahn, Hye Shin
    • Investigative Magnetic Resonance Imaging
    • /
    • v.18 no.2
    • /
    • pp.133-143
    • /
    • 2014
  • Purpose : The aim of this study was to determine the magnetic resonance imaging (MRI) features associated with re-excision due to the presence of a positive margin after breast conserving therapy (BCT) in breast cancer patients. Materials and Methods: We reviewed the records of 286 consecutive breast cancer patients who received BCT between January 2006 and December 2007. Among 246 patients who had undergone BCT, 38 (15.4%) underwent immediate further surgery due to positive margin status. We analyzed the MRI findings using ${\chi}^2$ test, Fisher's exact test and t tests. Multivariate logistic regression was conducted for prediction of re-excision. Results: Tumor size (p < 0.001), lesion multiplicity (p = 0.003), and non-mass-like enhancement (NMLE) type on MRI (p < 0.001) were associated with margin involvement in BCT. On preoperative MRI, larger size (${\geq}5cm$) (odds ratio = 2.96), NMLE (odds ratio = 3.81), and multifocal lesions (odds ratio = 2.54) were positively associated with re-excision. In cases involving NMLE, segmental distribution was associated with a greater likelihood of immediate re-excision. Conclusion: Larger size, multiplicity, and NMLE on MRI are significantly associated with re-excision after BCT in breast cancer patients. For NMLE lesions, the segmental distribution pattern was predictive of re-excision.

Early Recurrence of Breast Cancer after the Primary Treatment: Analysis of Clinicopathological and Radiological Predictive Factors (유방암 일차치료 후 조기 재발: 임상병리학적 및 영상의학적 예측인자 분석)

  • Sun Geun Yun;Yeong Yi An;Sung Hun Kim;Bong Joo Kang
    • Journal of the Korean Society of Radiology
    • /
    • v.81 no.2
    • /
    • pp.395-408
    • /
    • 2020
  • Purpose To evaluate the value of clinicopathologic factors and imaging features of primary breast cancer in predicting early recurrence after the primary treatment. Materials and Methods We enrolled 480 patients who had been followed-up after breast-conserving surgery and adjuvant therapy from January 2010 to December 2014 at our hospital. Early recurrence was defined as recurrence within 3 years after completion of primary treatment, and univariate and multivariate logistic regression analyses were performed to determine the clinicopathologic and imaging predictive factors of early recurrence. Results In the univariate analysis, among the clinicopathologic factors, advanced stage (p = 0.021), high histologic grade (p < 0.001), estrogen receptor negative (p = 0.002), high Ki-67 proliferation index (p = 0.017), and triple-negative breast cancer (p = 0.019), and among the imaging features, multifocality (p < 0.001), vessels in the rim on Doppler ultrasonography (US) (p = 0.012), and rim enhancement (p < 0.001) on magnetic resonance imaging of the breast were significantly associated with early recurrence. In the multivariate analysis, advanced stage [odds ratio (OR) = 3.47; 95% confidence interval (CI) 1.12-10.73; p = 0.031] and vessels in the rim on Doppler US (OR = 3.32; 95% CI 1.38-8.02; p = 0.008) were the independent predictive factors of early recurrence. Conclusion Vascular findings in the rim of the primary breast cancer on Doppler US before treatment is a radiologic independent predictive factor of early recurrence after the primary treatment.

Optimal Imaging Time for Diagnostic I-123 Whole Body Scan in the Follow-up of Patients with Differentiated Thyroid Cancer: Comparison between 6- and 24-Hour Images of the Same Subjects (분화 갑상선 암의 추적 관찰에서 진단적 I-123 전신 스캔의 최적 영상 시점: 동일 환자에서 6시간과 24시간 영상의 비교)

  • Lee, Hong-Je;Lee, Sang-Woo;Song, Bong-Il;Kang, Sung-Min;Seo, Ji-Hyoung;Yoo, Jeong-Soo;Ahn, Byeong-Cheol;Lee, Jae-Tae
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.43 no.2
    • /
    • pp.129-136
    • /
    • 2009
  • Purpose: To determine optimal imaging time for diagnostic I-123 whole body scan in the follow-up of patients with differentiated thyroid cancer(DTC), we compared the image quality of 6- and 24-hour images of the same subjects. Materials and Methods: Four hundred ninety-eight patients(M:F = 55:443, Age $47.6{\pm}12.9$ years) with DTC who had undergone total thyroidectomy and I-131 ablation therapy underwent diagnostic whole body scanning 6 hour and 24 hour after oral ingestion of 185 MBq(5 mCi) of I-123. Serum thyroglobulin measurement and ultrasonography of the neck were performed at the time of imaging. In 40 patients underwent additional I-131 therapy, post-therapy I-131 images were obtained and compared with diagnostic I-123 images. Results: In 440 patients(88.4%), 6- and 24-hour diagnostic I-123 images were concordant, and 58 patients(11.6%) showed discordant findings. Among 58 discordant patients, 31 patients showed abnormal tracer uptake on only 6-hour image, which turned out false-positive findings in all cases. In 12 patients with positive findings on only 24-hour image, remnant thyroid tissue(4 patients) and cervical lymph node metastasis(3 patients) were presented. Among 40 patients underwent additional I-131 therapy, 6-hour and 24-hour images were discordant in 13 patients. All 5 patients with abnormal uptake on only 6-hour image revealed false-positive results, whereas most of 24-hour images were concordant with post-therapy I-131 images. Conclusion: I-123 imaging at 24-hour could reduce false-positive findings and improve diagnostic accuracy, compared with 6-hour image in the follow-up of patient with DTC.

Comparison of Automated Breast Volume Scanning and Hand-Held Ultrasound in the Detection of Breast Cancer: an Analysis of 5,566 Patient Evaluations

  • Choi, Woo Jung;Cha, Joo Hee;Kim, Hak Hee;Shin, Hee Jung;Kim, Hyunji;Chae, Eun Young;Hong, Min Ji
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.21
    • /
    • pp.9101-9105
    • /
    • 2014
  • Background: The purpose of this study was to compare the accuracy and effectiveness of automated breast volume scanning (ABVS) and hand-held ultrasound (HHUS) in the detection of breast cancer in a large population group with a long-term follow-up, and to investigate whether different ultrasound systems may influence the estimation of cancer detection. Materials and Methods: Institutional review board approval was obtained for this retrospective study, and informed consent was waived. From September 2010 to August 2011, a total of 1,866 ABVS and 3,700 HHUS participants, who underwent these procedures at our institute, were included in this study. Cancers occurring during the study and subsequent follow-up were evaluated. The reference standard was a combination of histology and follow-up imaging (${\geq}12months$). The recall rate, cancer detection yield, diagnostic accuracy, sensitivity, specificity, and positive (PPV) and negative (NPV) predictive values were calculated with exact 95% confidence intervals. Results: The recall rate was 2.57 per 1,000 (48/1,866) for ABVS and 3.57 per 1,000 (132/3,700) for HHUS, with a significant difference (p=0.048). The cancer detection yield was 3.8 per 1,000 for ABVS and 2.7 per 1,000 for HHUS. The diagnostic accuracy was 97.7% for ABVS and 96.5% for HHUS with statistical significance (p=0.018). The specificity of ABVS and HHUS were 97.8%, 96.7%, respectively (p=0.022). Conclusions: ABVS shows a comparable diagnostic performance to HHUS. ABVS is an effective supplemental tool for mammography in breast cancer detection in a large population.

A Case of Pulmonary Paragonimiasis Presented as Solitary Pulmonary Nodule and Suspected as Lung Cancer on 18F-Fluorodeoxyglucose Positron Emission Tomography (양전자 방출 단층촬영에서 폐암으로 의심되었던 고립 폐 결절 형태의 폐흡충증 1예)

  • Moon, Jae Young;Jung, Ki Hwan;Kim, Je Hyeong;Park, Hyung Joo;Kim, Young Sik;Shin, Chol
    • Tuberculosis and Respiratory Diseases
    • /
    • v.64 no.2
    • /
    • pp.133-137
    • /
    • 2008
  • Pulmonary paragonimiasis continues to be a diagnostically challenging parasitic disease, despite a drastically decreased prevalence in South Korea during the past decade. Pulmonary paragonimiasis is characterized by fever, chest pain, and chronic cough with hemoptysis. Numerous radiographic and computed tomographic findings including the presence of pneumothorax, pleural effusion, and parenchymal lesions such as nodular or infiltrative opacities have been reported. The clinical and radiological manifestations of paragonimiasis can resemble those of lung cancer, tuberculosis or a metastatic malignancy. Furthermore, this disease can mimic lung cancer as seen on $^{18}F$-fluorodeoxyglucose positron emission tomography (FDG-PET). We report a case of pulmonary paragonimiasis in a 48-year old man that presented with a solitary pulmonary nodule and was suspected as a lung cancer based on FDG-PET imaging.