• Title/Summary/Keyword: Cancer imaging

Search Result 1,166, Processing Time 0.027 seconds

AIDS-Related Non-Hodgkin Lymphoma: Imaging Feature Analysis of 27 Cases and Correlation with Pathologic Findings

  • Yang, Jun;Wang, Peng;Lv, Zhi-Bin;Wei, Lian-Gui;Xu, Yun-Liang;Zhou, An;Xu, Dong-Hai;Ma, Da-Qing
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.18
    • /
    • pp.7769-7773
    • /
    • 2014
  • Background: Some tumor types are related to HIV, including non-Hodgkin lymphoma (NHL). The morbidity and mortality of NHL has remained high, even after highly active antiretroviral therapy (HAART) was introduced. We collected cases of AIDS with NHL, and evaluated the imaging features and strategies for diagnosis. Materials and Methods: There were 27 patients with AIDS and tumors confirmed by pathology. There were 9 patients with Burkitt lymphoma, 16 with diffuse large B cell lymphomas (DLBCLs), and 2 with primary central nervous system (PCNS) lymphomas. All of the patients underwent a series of imaging studies. Three radiologists analyzed the images, and any disagreement was discussed until consensus was reached. Results: The radiologic manifestations of AIDS with NHL were mainly masses and lymphadenopathy, 3 patients having one mass and 12 two or more masses. 7 patients had lymphadenopathy in one site and 3patients had lymphadenopathy in two or more sites. Coarse mucosal folds, thickening of the gastrointestinal wall, and lumen narrowing were typical manifestations of NHL within the gastrointestinal tract. There were 4 patients with masses and 5 with lymphadenopathy inthe 9 with Burkitt lymphoma, and 11 patients with masses 5 with lymphadenopathy in the 16 with DLBCLs. Conclusion: NHL is a malignancy that usually occurs in patients with AIDS. Imaging is an important method by which to evaluate lesions, masses, and lymphadenopathy. Fine needle aspiration biopsy and stereotaxis biopsy are useful methods by which to diagnose NHL.

Targeting Orthotopic Glioma in Mice with Genetically Engineered Salmonella typhimurium

  • Wen, Min;Jung, Shin;Moon, Kyung-Sub;Jiang, Shen Nan;Li, Song-Yuan;Min, Jung-Joon
    • Journal of Korean Neurosurgical Society
    • /
    • v.55 no.3
    • /
    • pp.131-135
    • /
    • 2014
  • Objective : With the growing interests of bacteria as a targeting vector for cancer treatment, diverse genetically engineered Salmonella has been reported to be capable of targeting primary or metastatic tumor regions after intravenous injection into mouse tumor models. The purpose of this study was to investigate the capability of the genetically engineered Salmonella typhimurium (S. typhimurium) to access the glioma xenograft, which was monitored in mouse brain tumor models using optical bioluminescence imaging technique. Methods : U87 malignant glioma cells (U87-MG) stably transfected with firefly luciferase (Fluc) were implanted into BALB/cAnN nude mice by stereotactic injection into the striatum. After tumor formation, attenuated S. typhimurium expressing bacterial luciferase (Lux) was injected into the tail vein. Bioluminescence signals from transfected cells or bacteria were monitored using a cooled charge-coupled device camera to identify the tumor location or to trace the bacterial migration. Immunofluorescence staining was also performed in frozen sections of mouse glioma xenograft. Results : The injected S. typhimurium exclusively localized in the glioma xenograft region of U87-MG-bearing mouse. Immunofluorescence staining also demonstrated the accumulation of S. typhimurium in the brain tumors. Conclusion : The present study demonstrated that S. typhimurium can target glioma xenograft, and may provide a potentially therapeutic probe for glioma.

Role of Contrast-Enhanced Ultrasound as a Second-Line Diagnostic Modality in Noninvasive Diagnostic Algorithms for Hepatocellular Carcinoma

  • Hyo-Jin Kang;Jeong Min Lee;Jeong Hee Yoon;Joon Koo Han
    • Korean Journal of Radiology
    • /
    • v.22 no.3
    • /
    • pp.354-365
    • /
    • 2021
  • Objective: To investigate the diagnostic performance of contrast-enhanced ultrasound (CEUS) and its role as a second-line imaging modality after gadoxetate-enhanced MRI (Gd-EOB-MRI) in the diagnosis of hepatocellular carcinoma (HCC) among at risk observations. Materials and Methods: We prospectively enrolled participants at risk of HCC with treatment-naïve solid hepatic observations (≥ 1 cm) of Liver Imaging Reporting and Data System (LR)-3/4/5/M during surveillance and performed Gd-EOB-MRI. A total of one hundred and three participants with 103 hepatic observations (mean size, 28.2 ± 24.5 mm; HCCs [n = 79], non-HCC malignancies [n = 15], benign [n = 9]; diagnosed by pathology [n = 57], or noninvasive method [n = 46]) were included in this study. The participants underwent CEUS with sulfur hexafluoride. Arterial phase hyperenhancement (APHE) and washout on Gd-EOB-MRI and CEUS were evaluated. The distinctive washout in CEUS was defined as mild washout 60 seconds after contrast injection. The diagnostic ability of Gd-EOB-MRI and of CEUS as a second-line modality for HCC were determined according to the European Association for the Study of the Liver (EASL) and the Korean Liver Cancer Association and National Cancer Center (KLCA-NCC) guidelines. The diagnostic abilities of both imaging modalities were compared using the McNemar's test. Results: The sensitivity of CEUS (60.8%) was lower than that of Gd-EOB-MRI (72.2%, p = 0.06 by EASL; 86.1%, p < 0.01 by KLCA-NCC); however, the specificity was 100%. By performing CEUS on the inconclusive observations in Gd-EOB-MRI, HCCs without APHE (n = 10) or washout (n = 12) on Gd-EOB-MRI further presented APHE (80.0%, 8/10) or distinctive washout (66.7%, 8/12) on CEUS, and more HCCs were diagnosed than with Gd-EOB-MRI alone (sensitivity: 72.2% vs. 83.5% by EASL, p < 0.01; 86.1% vs. 91.1% by KCLA-NCC, p = 0.04). There were no false-positive cases for HCC on CEUS. Conclusion: The addition of CEUS to Gd-EOB-MRI as a second-line diagnostic modality increases the frequency of HCC diagnosis without changing the specificities.

Systematic Review of Available Guidelines on Fertility Preservation of Young Patients with Breast Cancer

  • Haddadi, Mahnaz;Muhammadnejad, Samad;Sadeghi-Fazel, Fariba;Zandieh, Zahra;Rahimi, Gohar;Sadighi, Sanambar;Akbari, Parya;Mohagheghi, Mohammad-Ali;Mosavi-Jarrahi, Alireza;Amanpour, Saeid
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.3
    • /
    • pp.1057-1062
    • /
    • 2015
  • Background: Since the survival rate of breast cancer patients has improved, harmful effects of new treatment modalities on fertility of the young breast cancer patients has become a focus of attention. This study aimed to systematically review and critically appraise all available guidelines for fertility preservation in young breast cancer patients. Materials and Methods: Major citation databases were searched for treatment guidelines. Experts from relevant disciplines appraised the available guidelines. The AGREE II Instrument that includes 23 criteria in seven domains (scope and purpose of the guidelines, stakeholder involvement, rigor of development, clarity, applicability, editorial independence, and overall quality) was used to apprise and score the guidelines. Results: The search strategy retrieved 2,606 citations; 72 were considered for full-text screening and seven guidelines were included in the study. There was variability in the scores assigned to different domains among the guidelines. ASCO (2013), with an overall score of 68.0%, had the highest score, and St Gallen, with an overall score of 24.7%, had the lowest scores among the guidelines. Conclusions: With the promising survival rate among breast cancer patients, more attention should be given to include specific fertility preservation recommendations for young breast cancer patients.

Study of a Brain Tumor and Blood Vessel Detection System Using Multiple Fluorescence Imaging by a Surgical Microscope (수술현미경에서의 다중형광영상을 이용한 뇌종양과 혈관영상 검출 시스템 연구)

  • Lee, Hyun Min;Kim, Hong Rae;Yoon, Woong Bae;Kim, Young Jae;Kim, Kwang Gi;Kim, Seok Ki;Yoo, Heon;Lee, Seung Hoon;Shin, Min Sun;Kwon, Ki Chul
    • Korean Journal of Optics and Photonics
    • /
    • v.26 no.1
    • /
    • pp.23-29
    • /
    • 2015
  • In this paper, we propose a microscope system for detecting both a tumor and blood vessels in brain tumor surgery as fluorescence images by using multiple light sources and a beam-splitter module. The proposed method displays fluorescent images of the tumor and blood vessels on the same display device and also provides accurate information about them to the operator. To acquire a fluorescence image, we utilized 5-ALA (5-aminolevulinic acid) for the tumor and ICG (Indocyanine green) for blood vessels, and we used a beam-splitter module combined with a microscope for simultaneous detection of both. The beam-splitter module showed the best performance at 600 nm for 5-ALA and above 800 nm for ICG. The beam-splitter is flexible to enable diverse objective setups and designed to mount a filter easily, so beam-splitter and filter can be changed as needed, and other fluorescent dyes besides 5-ALA and ICG are available. The fluorescent images of the tumor and the blood vessels can be displayed on the same monitor through the beam-splitter module with a CCD camera. For ICG, a CCD that can detect the near-infrared region is needed. This system provides the acquired fluorescent image to an operator in real time, matching it to the original image through a similarity transform.

Measurements of Setup Error and Physiological Movement of Liver by Using Electronic Portal Imaging Device in Patients with Hepatocellular Carcinoma (간암환자에서 Electronic Portal Imaging Device(EPID)를 이용한 자세 오차 및 종양 이동 거리의 객관적 측정)

  • Keum Ki Chang;Lee Sang-wook;Shin Hyun Soo;Kim Gwi Eon;Sung Jinsil Seong;Lee Chang Geol;Chu Sung Sil;Chang Sei-Kyung;Suh Chang Ok
    • Radiation Oncology Journal
    • /
    • v.18 no.2
    • /
    • pp.107-113
    • /
    • 2000
  • Purpose : The goal of this study 닌as to improve the accuracy of three-dimensional conformal radiotherapy (3-D CRT) by measuring the treatment setup error and physiological movement of liver based on the analysis of images which were obtained by electronic portal imaging device (EPID). Materials and Methods : For 10 patients with hepatocellular carcinoma, 4-7 portal images were obtained by using EPID during the radiotherapy from each patient daiiy. We analyzed the setup error and physiological movement of liver based on the verification data. We also determined the safety margin of the tumor in 3-D CRT through the analysis of physiological movement. Results : The setup errors were measured as 3mm with standard deviation 1.70 mm in x direction and 3.7 mm with standard deviation 1.88 mm in y direction respectively. Hence, deviation were smaller than 5mm from the center of each axis. The measured range of liver movement due to the physiological motion was 8.63 mm on the average. Considering the motion of liver and setup error, the safety margin of tumor was at least 15 mm. Conclusion : EPID is a very useful device for the determination of the optimal margin of the tumor, and thus enhance the accuracy and stability of the 3-D CRT in patients with hepatocellular carcinoma.

  • PDF

Feasibility Study for the Development of a Device for Detecting Pathological Tissues (병리학적 조직 진단장치 개발에 대한 타당성 분석 연구)

  • Ko, Chea-Ok;Park, Min-Young;Pack, Jeong-Ki
    • Proceedings of the Korea Electromagnetic Engineering Society Conference
    • /
    • 2005.11a
    • /
    • pp.421-424
    • /
    • 2005
  • X-ray is currently most effective method in detecting small malignant breast tumors but has the several problems due to suppressing breast, ionizing radiation and not detecting small cancer. In this paper, a new method is proposed by using dielectric characteristics of pathological tissues and time delay of backscattered response. We have developed a detection algorithm and verified it by numerical simulation and measurement for a prototype system. For a prototype system, we have fabricated experimental model(artificial breast with a cancer) and UWB(ultra-wideband) antenna. The results of the measurement simulation show an excellent detection capability of a cancer tissue. It is found that a good UWB antenna is a key element of such detection system. Further study is ongoing to develop a commercial system.

  • PDF

Clinical Application of F-18 FDG PET (PET/CT) in Colo-rectal and Anal Cancer (대장-직장 및 항문암에서 F-18 FDG PET (PET/CT)의 임상 이용)

  • Kim, Byung-Il
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.42 no.sup1
    • /
    • pp.52-59
    • /
    • 2008
  • In the management of colo-retal and anal cancer, accurate staging, treatment evaluation, early detection of recurrence are main clinical problems. F-18 FDG PET (PET/CT) has been reported as useful in the management of colo-rectal and anal cancer because that PET has high diagnostic performance comparing to conventional studies. In case of liver metastases, for confirmation of no extrahepatic metastases, in case of high risk of metastasis, for avoiding unnecessary operation, PET (PET/CT) is expected more useful. In anal cancer, PET is expected useful in lymph node staging. For the early prediction of chemotherapy or radiation therapy effect PET has been reported as useful, also. In early detection of recurrence by PET, cost-benefit advantages has been suggested, also. PET/CT is expected to have higher diagnostic performance than PET alone.

2D Microwave Image Reconstruction of Breast Cancer Detector Using a Simplex Method and Method of Moments

  • Kim, Ki-Chai;Cho, Byung-Doo;Kim, Tae-Hong;Lee, Jong-Moon;Jeon, Soon-Ik;Pack, Jeong-Ki
    • Journal of electromagnetic engineering and science
    • /
    • v.10 no.4
    • /
    • pp.199-205
    • /
    • 2010
  • This paper presents a tumor detection system for breast cancer that utilizes two-dimensional (2D) image reconstruction with microwave tomographic imaging. The breast cancer detection system under development consists of 16 transmit/receive antennas, and the microwave tomography system operates at 900 MHz. To solve a 2D inverse scattering problem, the method of moments (MoM) is employed for forward problem solving, and the simplex method employed as an optimization algorithm. The results of the reconstructed image show that the method accurately shows the position of a breast tumor.

$DaVinci^{TM}$ S robot-assisted esophagectomy in a 83-year-old patient with esophageal cancer (고령의 식도암 환자에서 다빈치 S 로봇을 이용한 식도 절제술)

  • Haam, Seok-Jin;Park, Seong-Yong;Paik, Hyo-Chae
    • Korean Journal of Bronchoesophagology
    • /
    • v.14 no.2
    • /
    • pp.53-56
    • /
    • 2008
  • The postoperative respiratory complications such as pneumonia and ARDS, are poor prognostic factors after esophagectomy in patients with esophageal cancer. To avoid these complications, there have been attempts to use minimally invasive approach. Recently introduced daVinciTM S surgical system is used in esophagectomy because of its advantages of minimal invasiveness, clear 3-dimensional imaging and precise handling of robotic arms. We report a 83-year-old esophageal cancer patient who underwent daVinciTMS robot-assisted esophagectomy, laparoscopic stomach mobilization followed by cervical esophagogastrostomy.

  • PDF