• Title/Summary/Keyword: Canal 5

Search Result 849, Processing Time 0.025 seconds

APICAL FITNESS OF NON-STANDARDIZED GUTTA-PERCHA CONES IN SIMULATED ROOT CANALS PREPARED WITH ROTARY ROOT CANAL INSTRUMENTS (전동화일로 형성된 근관에서 비표준화 Gutta-percha Cone의 적합성)

  • Kwon, O-Sang;Kim, Sung-Kyo
    • Restorative Dentistry and Endodontics
    • /
    • v.25 no.3
    • /
    • pp.390-398
    • /
    • 2000
  • The purpose of this study was to evaluate the apical fitness of non-standardized gutta-percha cones in root canals prepared with rotary Ni-Ti root canal instruments of various tapers and apical tip sizes. Simulated sixty curved root canals of plastic blocks were prepared with crown-down technique using rotary root canal instruments of Maillefer ProFile$^{(R)}$ .04 and .06 taper (Maillefer Instrument SA, Switzerland). Specimens were divided into six groups and prepared as follows: Group 1, prepared up to size 25 of .04 taper ; Group 2, prepared up to size 30 of .04 taper ; Group 3, prepared up to size 35 of .04 taper ; Group 4, prepared up to size 25 of .06 taper ; Group 5, prepared up to size 30 of .06 taper ; Group 6 ; prepared up to size 35 of .06 taper. After cutting off the coronal portion of plastic, blocks perpendicular to the long axis of the canal with the use of a diamond saw, apical 5mm of canal space was analyzed. Prepared apical canal spaces were duplicated using rubber base impression material to evaluate two dimensional total area of apical canal space. Various sized gutta-percha cones were applied in the 5mm-apical canal space, which were size 25, size 30 and size 35 standardized gutta-percha cone, Diadent Dia-Pro ISO-.04$^{TM}$ and .06$^{TM}$(Diadent, Korea), and medium-fine (MF), fine (F), fine-medium (FM) and medium (M) sized non-standardized gutta-percha cones (Diadent, Korea). Coronal excess gutta-percha were cut off with a sharp blade. Photographs of impressed apical canal spaces and gutta-percha cones were taken with a CCD camera under a stereomicroscope and stored in a computer. Areas of the total canal space and gutta-percha cones were calculated using a digitalized image analysing program, CompuScope (Sungjin Multimedia Co., Korea). Ratio of apical fitness was obtained by calculating the area of gutta-percha cone to the total area of the canal space. The data were analysed statistically using One-way Analysis of Variance and Duncan's Multiple Range Test. The results were as follows: 1. In canals prepared up to size 25 ProFile$^{(R)}$ of .04 taper, non-standardized MF and F cones occupied significantly more canal space than Dia-Pro ISO-.04$^{TM}$ or size 25 standardized ones (p<0.05). 2. In canals prepared up to size 30 ProFile$^{(R)}$ of .04 taper, non-standardized F cones occupied significantly more canal space than Dia-Pro ISO-.04$^{TM}$ or size 30 standardized ones (p<0.05), and non-standardized MF cones occupied more canal space than size 30 standardized ones (p<0.05). 3. In canals prepared up to size 35 ProFile$^{(R)}$ of .04 taper, there was no significant difference in canal space occupation among non-standardized MF and F, size 35 standardized, and Dia-Pro ISO-.04$^{TM}$ cones (p>0.05). 4. In canals prepared up to size 25 ProFile$^{(R)}$ of .06 taper, non-standardized MF and F cones occupied significantly more canal space than Dia-Pro ISO-.06$^{TM}$, or size 25 standardized ones (p<0.05), and Dia-Pro ISO-.06$^{TM}$, cones occupied significantly more space than size 25 standardized ones (p<0.05). 5. In canals prepared up to size 30 ProFile$^{(R)}$ of .06 taper, non-standardized FM cones occupied significantly more canal space than Dia-Pro ISO-.06$^{TM}$ or size 30 standardized ones (p<0.05), and non-standardized F cones occupied significantly more canal space than size 30 standardized ones (p<0.05). 6. In canals prepared up to size 35 ProFile$^{(R)}$ of .06 taper, non-standardized M and FM, Dia-Pro ISO-.06$^{TM}$ occupied significantly more canal space than size 35 standardized ones (p<0.05). In summary, in both canals prepared with .04 or .06 taper ProFile$^{(R)}$, non-standardized cones showed better fitness than Dia-Pro ISO$^{TM}$ or standardized ones, which was more characteristic in smaller canals.

  • PDF

A SCANNING ELECTRON MICROSCOPIC STUDY OF THE CLEANSING EFFECT OF RC-PREP ON THE DENTINAL WALLS OF THE ROOT CANAL (RC-Prep의 근관정화효과(根管淨化效果)에 관(關)한 주사전자현미경적(走査電子顯微鏡的) 연구(硏究))

  • Lim, Sung-Sam
    • Restorative Dentistry and Endodontics
    • /
    • v.7 no.1
    • /
    • pp.65-69
    • /
    • 1981
  • This study was conducted to evaluate the cleansing effect of RC-Prep (10% Urea-peroxide, 15% EDTA) on apical third of root canal. Thirty single rooted human teeth were divided into three groups, and ten canals in each group were all enlarged three sizes greater than their original diameter with K-type files and irrigated with each of three irrigants. The three used irrigants were RC-prep (Premier Co.) in combination with 3.5% Sodium hypochlorite, Normal saline, 3.5% Na OCL. In each group, one of three irrigants were used in conjunction with instrumentation as they would be during clinical condition. After final irrigation, the canals were dried with paper points and the teeth were split longitudinally. The cleanness of canal walls iii the apical region were examined with Scanning Electron Microscope. The following results were drawn. 1. The use of Rc-Prep in combination with 3.5% NaOCl showed more clean canal surface than the use of other two irrigants. 2. The canals used RC-Prep in combination with 3.5% NaOCl revealed remnants of pulp tissue and smeared layer, but the openings of dentinal tubules were relatively clean and wide. 3. There was no significant difference in the debridement effect of 3.5% NaOCl and Saline solution. 4. The use of Saline solution showed great amount of remnants of pulp tissue which couldn't find in the use of 3.5% NaOCl.

  • PDF

3-dimensional reconstruction of mandibular canal at the interforaminal region using micro-computed tomography in Korean

  • Jeon, Yong Hyun;Lee, Chul Kwon;Kim, Hee-Jung;Chung, Jae-Heon;Kim, Heung-Joong;Yu, Sun-Kyoung
    • The Journal of Advanced Prosthodontics
    • /
    • v.9 no.6
    • /
    • pp.470-475
    • /
    • 2017
  • PURPOSE. The purpose of this study was to identify the complex course of the mandibular canal using 3D reconstruction of microCT images and to provide the diagram for clinicians to help them understand at the interforaminal region in Korean. MATERIALS AND METHODS. Twenty-six hemimandibles obtained from cadavers were examined using microCT, and the images were reconstructed. At both the midpoint of mental foramen and the tip of anterior loop, the bucco-lingual position, the height from the mandibular inferior border, the horizontal distance between two points, and position relative to tooth site on the mandibular canal were measured. The angle that the mental canal diverges from the mandibular canal was measured in posterior-superior and lateral-superior direction. RESULTS. The buccal distance from the mandibular canal was significantly much shorter than lingual distance at both the mental foramen and the tip of anterior loop. The mandibular canal at the tip of anterior loop was significantly located closer to buccal side and higher than at the mental foramen. And the mental canal most commonly diverged from the mandibular canal below the first premolar by approximately $50^{\circ}$ posterior-superior and $41^{\circ}$ lateral-superior direction, which had with a mean length of 5.19 mm in front of the mental foramen, and exited to the mental foramen below the second premolar. CONCLUSION. These results suggest that it could form a hazardous tetrahedron space at the interforaminal region, thus, the clinician need to pay attention to the width of a premolar tooth from the mental foramen during dental implant placement.

AN EXPERIMENTAL STUDY OF THE EFFICACY OF SONIC AND ULTRASONIC ROOT CANAL PREPARATION TECHNIQUES (음파 및 초음파기구를 이용한 근관형성법의 효율성에 관한 실험적 연구)

  • Kim, Han-Wook;Lee, Chung-Sik
    • Restorative Dentistry and Endodontics
    • /
    • v.13 no.1
    • /
    • pp.79-89
    • /
    • 1988
  • The purpose of this study was to evaluate the canal preparation time, deviation of the apex (Zipping), and debridement effect of the canal of three canal preparation techniques. Thirty extracted 1st and 2nd molars were divided into 3 groups and each group was enlarged by ultrasonic, sonic or hand instrument. The specimens were examined under scanning electron microscope and light microscope. The results were as follows: 1. In the canal preparation time, ultrasonic group was the shortest, followed by sonic, hand group. All pairs of groups were significantly different at the 0.05 level. (P < 0.05) 2. In the deviation of the canal, no two groups were significantly different at the 0.05 level. (P > 0.05) 3. In the evaluation of debris scores, ultrasonic and sonic groups were better debridement effect than hand group in the fine canals. In the large canals, ultrasonic group was the best results, followed by sonic, hand group. 4. In the evaluation of smear layer scores, ultrasonic group was the best and sonic and hand group were same effect in the fine canals. In the large canals, three groups were same effect. 5. In the effect of the removal of predentin and pulpal debris, in the regardless of canal size, three groups were same and pulpal debris was not completely removed by either technique.

  • PDF

A comparison of the shaping ability of reciprocating NiTi instruments in simulated curved canals

  • Yoo, Young-Sil;Cho, Yong-Bum
    • Restorative Dentistry and Endodontics
    • /
    • v.37 no.4
    • /
    • pp.220-227
    • /
    • 2012
  • Objectives: The study was to compare the shaping ability of Reciproc (VDW) and WaveOne (Dentsply Maillefer) instruments compared with ProTaper, Profile and hand instrument during the preparation of simulated root canals. Materials and Methods: Five groups (n = 5) were established. Reciproc, WaveOne, ProTaper, Profile and K file (K-flexo file) were used to prepare the resin simulated canals. A series of preoperative and postoperative images were taken by a microscope and superimposed in 2 different layers. The amount of resin removed from both the inner and the outer sides of the canal was measured to the level of 10 mm from the apical tip, with a 1 mm increment. Results: The mean of resin removal from the inner canal wall was not different from the outer canal wall for Reciproc and WaveOne groups at apical third (1 - 3 mm level). There was no difference in the change of working length and maintenance of canal curvature. NiTi instruments are superior to stainless-steel K file in their shaping ability. Conclusions: Within the limitation of this present study, Reciproc and WaveOne instruments maintained the original canal curvature in curved canals better than ProTaper and Profile, which tend to transport towards the outer canal wall of the curve in the apical part of the canal.

SCANNING ELECTRON MICROSCOPIC STUDY OF THE EFFECT OF ULTRASOUND IN THE REMOVAL OF THE SMEAR LAYER FROM THE ROOT CANAL WALL (ULTRASOUND가 근관벽의 도말층제거에 미치는 영향에 관한 주사전자현미경적 연구)

  • Yoon, Seung-Seob;Hong, Chan-Ui
    • Restorative Dentistry and Endodontics
    • /
    • v.16 no.1
    • /
    • pp.167-180
    • /
    • 1991
  • The purpose of theis study was to evaluate the effectiveness of ultrasonic instrumentation in removing debris and smear layer from the root canal walls. 54 extracted, permanent single rooted teeth were randomly divided into 6 groups of 9 teeth. After canal preparation, the teeth were longitudinally sectioned. The sepcimens were then naturally dried for 2 days, given a maximun thickness gold coating, and examined under the SEM (JSM-35C type, JAPAN). Photographs of all specimens were then taken of the middle and the apical third of the root canal wall. The results were as follows: 1. In all groups, debris and the smear layer were not completely removed from the canal wall 2. There were no significant differences between at the apical third and at the middle third in removing debris and the smear layer in all groups. 3. There were no significant difference between the step - back group and the ultrasound group in removing debris and smear layer. 4. In general, the step - back/ultrasonund groups showed greater canal debridement than the step - back group or ultrasound group. 5. The step - back/ultrasound group with a No. 25 file for 3 min. showed significantly greater canal debridement than the step-back group (p<0.05), or the other step - back/ultrasound groups(p<0.05).

  • PDF

A study of mandibular canal angle and location of mental foramen on the panoramic radiograph (파노라마방사선사진에서의 하악관의 각도와 이공의 위치에 관한 연구)

  • Choi, Hang-Moon
    • Imaging Science in Dentistry
    • /
    • v.39 no.2
    • /
    • pp.89-92
    • /
    • 2009
  • Purpose: To assess the angle between mandibular canal and occlusal plane at each posterior tooth region and location of mental foramen on the panoramic radiographs. Materials and Methods: This study analysed 46 half-mandibles of panoramic radiographs. Inferior border of mandibular canal was traced. Occlusal plane was drawn from lingual cusp tip of the first premolar to distolingual cusp tip of the second molar. Perpendicular line from occlusal plane was drawn at each tooth region and then tangential lines were drawn from the crossing points at canal. the angle between occlusal plane and tangential line was measured. The location of mental foramen was also studied. According to the location of mental foramen, radiographs were divided into M (mesial) group and D (distal) group on the basis of the second premolar. and then inter-group analysis about mandibular canal angle was done. Results: The angles of mandibular canals were -17.7$^{\circ}$, -9.5$^{\circ}$, 8.2$^{\circ}$, 22.3$^{\circ}$, and 39.2$^{\circ}$at first premolar, second premolar, first molar, second molar, and third molar, respectively. The commonest position of the mental foramen was distal to the second premolar. Inter-group comparison showed statistically significant difference at the second premolar and the first molar(p<0.001). Conclusion: The knowledge of mandibular canal angle and location of mental foramen can help understanding the course of mandibular canal. (Korean J Oral Maxillofac Radiol 2009; 39: 89-92)

  • PDF

Improvement of Symptoms after Excision of Hydrocele of Canal of Nuck with Korean Medicine: A Case Report (누크관 수종 제거 이후 후유증에 대한 한방치료 1례 : 증례보고)

  • Subin Ahn;Jiyoon Yeom;Nayeon Hur;Seiyoung Kang
    • The Journal of Internal Korean Medicine
    • /
    • v.44 no.5
    • /
    • pp.941-947
    • /
    • 2023
  • Objective: The purpose of this case study is to report the hydrocele of the canal of Nuck and the effectiveness of Korean medicine in post-surgery improvement of symptoms. Method: A patient who was diagnosed with hydrocele of the Nuck canal and had symptoms after Lichtenstein's operation was treated using Korean medicine, including acupuncture, herbal medicine, and moxibustion, every day. The evaluation was performed using the Numeral Rating Scale (NRS), the 5-level EQ-5D version (EQ-5D-5L), the EQ visual analogue scale (EQ-VAS), and the World Health Organization Quality of Life-Brief (WHOQOL-BREF). Results: After treatment, changes were observed in NRS (from 8 to 2-3) and EQ-VAS (from 60 to 85), whereas there was no difference in EQ-5D-5L (both 6). There was an overall improvement in the domains of WHOQOL-BREF and subjective symptoms. Conclusion: This study suggests that Korean medicine may improve symptoms after surgery of hydrocele of the canal of Nuck and can be evaluated using an overall QoL questionnaire.

Incomplete atrioventricular canal associated with tricuspid valve cleft and multiple ASD: report of one case (삼첨판균열과 다발성 심방중격결손을 합병한 Incomplete Atrioventricular Canal 의 치험)

  • O, Sang-Jun;Kim, Sam-Hyeon;Kim, Geun-Ho
    • Journal of Chest Surgery
    • /
    • v.17 no.4
    • /
    • pp.614-619
    • /
    • 1984
  • Atrioventricular canal is divided into incomplete, intermediate and complete types. In ostium primum ASD [incomplete type] mitral valve cleft is almost always present, but ostium primum ASD with tricuspid valve cleft is a rare congenital anomaly. The patient was a 7 year old female whose complains were palpitation, exertional dyspnea and growth retardation. The chest films showed moderate cardiomegaly [C-T ratio, 61%]. EKG, Echocardiography, cardiac catheterization and left ventriculography were performed. Open heart surgery was done under the impression of incomplete atrioventricular canal. At the time of operation, ostium primum ASD [2x2.5 cm in diameter], secundum type ASD [lxl.5 cm in diameter] and cleft in the septal leaflet of the tricuspid valve were noted. But mitral valve was normal without cleft and VSD was not noted. Each anomalous portion was repaired. The patient made an uneventful recovery and we report this case, review and discuss the literatures.

  • PDF

'Design and Construction of 7 kilometres of 2.5 cubic metre per second Canal'

  • Euinton, Gordon;Tate, Don
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2008.05a
    • /
    • pp.1-8
    • /
    • 2008
  • The paper describes the process and issues encountered during the design and construction of seven kilometres of canal to convey 2.5 cumecs of flow to two power stations. The location of the scheme above the primary reservoir of the Waipori Hydropower scheme in Otago, New Zealand, utilising an existing stream diversion into this reservoir, means that no new water abstraction or diversion consents were required. This mini hydro development associated with the existing Waipori scheme was partly justified by an allocation of carbon credits. The scheme controls are slightly more complicated than many canal and penstock schemes as the canal lengths are considerable in relation to the gradient.

  • PDF