• Title/Summary/Keyword: Campus Facility

Search Result 76, Processing Time 0.024 seconds

A Study on the Analytical Technique for the Actual Conditions of Fundamental Facility for Education in University Campus - Focused on the Case of C University Campus in Gyeongbuk - (대학 캠퍼스 교육기본시설 운용실태 분석기법에 관한 연구 - 경북 소재 C대학의 사례를 중심으로 -)

  • Kim, Chi-Hwan
    • The Journal of Sustainable Design and Educational Environment Research
    • /
    • v.9 no.1
    • /
    • pp.41-51
    • /
    • 2010
  • It is high level of management activity for the fixed property of building to operating spaces for education in university campus. Therefore, this study is focused on definition of the factors for analyzing the actual conditions of space operation and application of them to C university campus in Gyeongbuk in the aspect of infrastructure of university and efficiency of space operation. These analytical factors are the rate of lecture and experimentation room, the rate of theoretical and experimental subject in curriculum and unit area for infrastructure and the rate of use, turnover rate and occupation rate per lecture for space operation. If the analytical factors of space operation are systemized as program module for space operation, the space management system of university campus will be characterized on the foundation of university information system. And it will be able to support the decision making about space management. It needs to integrate various type of information and data of university to increase the efficiency of decision making.

Causes of Change Orders in the Military Facility Construction Projects and Suggestions for Improvement (군사시설 건설사업의 설계변경 요인분석 및 개선방향)

  • Lee, Kyoung-Han;Choi, Jong-Soo
    • Journal of the Korea Institute of Building Construction
    • /
    • v.13 no.3
    • /
    • pp.263-271
    • /
    • 2013
  • Change orders have been widespread in both the private and public construction sectors. In particular, in the case of G2B (Government to Business) contracts, adjustment of contract price and/or schedule extension is a frequent occurrence due to change orders. To uncover the causes of change orders and suggest an appropriate strategy, this study analyzed 296 cases of change orders in military facility construction projects from 2008 to 2010. The analysis revealed that the major causes of change orders are users' additional requirements (28.38%), a change of finishing materials (23.99%), and change of footing type (17.57%), in that order. Building on the results of this analysis, the authors suggest plans for practical improvements. Specific recommendations include 1) reflect user requirements at the early stage, 2) minimize the use of additional budget due to change orders, and 3) reduce the process and time for contract amendment, among others. The results of this study may provide significant implications to those involved in military construction projects, particularly project owners (i.e., the Ministry of Defense) and contractors.

A Study on Strategy to Develop Underground Space of Campus - Focused on the Analyses of the Campuses of Main Universities Nationwide - (캠퍼스 지하공간 개발전략 연구 - 국내 주요대학 캠퍼스 분석을 중심으로 -)

  • Park, Hoon
    • Journal of the Korean Institute of Educational Facilities
    • /
    • v.19 no.6
    • /
    • pp.3-14
    • /
    • 2012
  • University campus has grown and developed along with history of human in connection with transition characteristics of city. In particular, reflecting the features in the times, the masterplan should explore its main roles today when international growth of university is pursued. In particular, center core and quad space, focusing on main components of campus such as main building, student union hall and main lecture facility, are the prototype of campus components and have been pursued to have importance in terms of shape and function as traditional campus space strategy. Recently, however, new strategy has been proposed to explore orders of campus utilizing the underground space focusing on main universities. Design of Hana Plaza of Korea University and Bekyangro of Yeonsei University, the targets of this study, actively explore this strategy. This study analyzed such strategies in terms of concept of space to obtain space, design trend of main universities at home and abroad, and viewpoint of integrated masterplan proposal. Conclusions from this study are as follows. First, concept of quad and center space found in the design of traditional campus is reinterpreted into new design aspects through development of underground space. Second, development of underground space is approached to overcome the limit of existing campus and to present the vision of universities 100 years ahead. Third, ever-changing complicated urban environment has been reflected in space configuration of campus and positioned as strategy to implement this as modern construction technique. Third, implementation of pedestrian-oriented campus has been pursued by reinforcing utilization of inclined topography of urban environment in Korea. This enables to obtain spaces for main activities of students and to implement the space where student support facilities are concentrated and activities are performed actively. Such features can be presented as conclusions of this study.

A Comparison Analysis on the Facility Standards and Campus Sizes of the National Universities in Korea and Japan (한·일 국립대학 시설 기준 및 캠퍼스 면적 비교·분석)

  • Choi, Hyeong Ju
    • The Journal of Sustainable Design and Educational Environment Research
    • /
    • v.18 no.3
    • /
    • pp.1-15
    • /
    • 2019
  • This study analyzes universities in Japan, which haves many similarities with those in Korea in certain aspects of the educational system and a common problem of reduced university admission resources, Korea's national university facility standards, policy related to nation-level university facility, and practical campus case. Through this, the study aims to examine the difference in the national approach and basic philosophy about university facilities in Korea and Japan, and also identify the major planning factors and improvement directions when establishing plans for university campuses in the future. The results of this study are as follows. First, Korea tends to promote policies related to university facilities by individual projects centered on a major pending problem or issue, while Japan has been shown to promote national university facility policies under a comprehensive mid-to-long-term plan by establishing a maintenance plan aimed at national university facilities every five years. Second, In the case of the university facility areas, the average university facility area of the examined universities in Japan is about 5.6% larger than the average university facility area in Korea. Additionally, the university facility area per student in Japan is about 13% wider than that of Korea. The total floor area of university facilities in Japan is also about 20.7% larger than that of Korea, and the university facility area per student in Japan is about 56.7% wider than that of Korea as well. Among support facilities, the total floor area of dormitories in Korea was 2.5 times wider than that of Japan, however, the acceptance rate of dormitory in Korea was 5.6% higher than Japan. Third, the university facility criteria items and systems of two countries are similar. but there are slight differences in the content such as the method of calculating student capacity, division classification, and the method of calculating the number of teachers.

A Study on the Outdoor Lighting of Campuses on the Ground of the User-Satisfaction (이용자 만족도에 의거한 캠퍼스 옥외조명 연구)

  • Kim Dong-Chan;Min Chang-Ki
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.33 no.1 s.108
    • /
    • pp.1-9
    • /
    • 2005
  • The purpose of this study is to form a night-view at a university to satisfy users through case studies of four representative university campuses with analyzing the lighting conditions and facility satisfaction. The result of this study is following. From the present lighting status, there are 664(l9types) lightings at Kyunghee University, 350(17types) at Sungkyunkwan University and 437(l9types) at Ajou University. Main materials of the lightings are metal, iron and stainless. Moreover, most illuminants are white-colored metal-halide lamp. There is no specially designed lighting facility because ready-made goods were used. Furthermore, the locations of lightings are not suitable so some are useless. Most main spatial illuminations are not satisfying outdoor standard, so it can be concluded that the designs of present campuses are not carrying on with-out plans. From the result, present campus lighting does not satisfy the desire of users in aesthetic and functional point of view but consider the luminosity. However, even though the luminosity does not standardize the law. It is because the design does not reflect a suitable standard with desire of users and it does not have a long term plan. Moreover, the campus design has no study about development plan even though it has enough green area which has a potential possibility to overcome the lack of green areas in a city. Therefore, it is needed to design a comprehensive campus plan which satisfies the desire of students and residents with considering promotion of excitement and harmony through adjusting luminosity of the lighting facilities and supplying various lighting resources.

Evaluation of User Satisfaction and Image Preference of University Students for Cherry Blossom Campus Trail (대학생들의 캠퍼스 벚꽃터널 산책로 이용 만족도와 이미지 선호도 평가)

  • Lee, In-Gyu;Eom, Boong-Hoon
    • Journal of Environmental Science International
    • /
    • v.28 no.12
    • /
    • pp.1101-1110
    • /
    • 2019
  • This study investigated Post-Occupancy Evaluation (POE) of cherry blossom trails 'Cherry Road' in Daegu Catholic Univ. campus, at Gyeonsan-city, Korea. The evaluation focused on image preference and satisfaction of users i.e., students, using questionnaire surveys. A total 201 questionnaire samples were analyzed and most of the respondents were in the age group of 20. Frequency analysis was conducted on demographics, use behavior, reliability, and means. Factor analysis and multiple regression analysis were conducted for user satisfaction and image preference. Over 80% of visitors came with companions during daytime. The most common motives for use were strolling and walking, event and meeting, passing. For user satisfaction the mean scores were highest for landscape beauty (4.22), image improvement (4.14), campus image (4.08). Night lighting facility received the lowest score (3.32). Factor analysis concerning user satisfaction was categorized into environment-human behavior and physical factors. Multiple regression analysis showed that the overall satisfaction of user was significantly influenced by five independent variables: 'harmonious' (β=.214), 'night lighting facility' (β=.173), 'landscape beauty' (β=.208), 'lawn care' (β=.154), and 'walking trails' (β=.123). The mean scores of image variables were highest for 'beautiful' (5.81), 'bright' (5.67), and 'open' (5.64). The lowest scores was for 'quiet' (4.47). Exploratory factor analysis led to three factors being categorized: aesthetics, comforts, and simplicity. Result of multiple regression analysis indicated that the preference of space image was significantly influenced by five variables: 'bright' (β=.397), 'refreshing' (β=.211), 'cool' (β=.219), 'clean' (β=.182), and 'natural' (β=.-142). Hence, Cherry Road has a high level of user satisfaction and image evaluation, which is interpreted as having various cultural events and value for students on campus. To improve the satisfaction of Cherry Road in the future, it is necessary to secure night lighting, to manage trash cans, and to secure rest space.

A Study on the Influencing to Satisfaction of College Life (대학생활만족에 영향을 미치는 요인에 관한 연구)

  • Lee Kong-Seob
    • Management & Information Systems Review
    • /
    • v.18
    • /
    • pp.223-251
    • /
    • 2006
  • This study examines the factors that have an effect on the satisfaction of student campus life in two college. By the survey questionnaire, three factors selected from 14 questionnaire by factor analysis in the college environmental character. Those factors ware analyzed to estimate the results of this study. And the effect and type of word of mouth communication surveyed by one questionnaire respectively. The major results of this study are as follow; First, the factors that effected on satisfaction of students are the distinction of sex, the division of major field and the distinction of college. But the academic grade factor is not available, Second, the factors of tutors/curriculums and education support service effected on satisfaction of students in campus life, but the factor of education convenience facility is not. Finally, the effect and communication of word of mouth resulted in effectiveness for on satisfaction of students in campus life.

  • PDF

Service Quality in Distribution Through Academics, Administration, and Facilities, Affects Brand Performance

  • FAKHRUDIN, Arif;YUDIANTO, Kifni;DHARASTA, You She Melly Anne
    • Journal of Distribution Science
    • /
    • v.21 no.1
    • /
    • pp.65-72
    • /
    • 2023
  • Purpose: The purpose of this study was to determine the effect of Service Quality on Brand Performance through Satisfaction at an aviation campus in the Special Region of Yogyakarta, Indonesia. Research design, data, and methodology: This research design was hypothesis testing using primary data obtained by distributing questionnaires directly to 200 respondents who were active students at an aviation campus in the Special Region of Yogyakarta, Indonesia. The analytical method used was the Structure Equation Model (SEM). Results: The results of this study show that: (1) there was a significant and positive relationship between Service Quality and Satisfaction, (2) there was a significant and positive relationship between Satisfaction with Brand Performance, and (3) there was a significant and positive relationship between Service Quality and Brand Performance. Conclusion: This study concludes that for the dimension of Academic service quality distribution from the service quality variable, it is suggested to improve detailed recording by academic teaching staff. For the dimensions of Administrative Service Quality distribution from the Service Quality variable, it is recommended to increase the hospitality in the campus environment. For the dimensions of Facility Service Quality distribution from the Service Quality variable, it is recommended to increase satisfaction in terms of facilities on campus. For the Satisfaction variable, it is suggested to improve the performance of the staff and the academic community.

Survey on the Perception of Campus Facility Staff for the Development of a Campus Greenhouse Gases Management System (대학단위 온실가스 관리 프로그램 개발을 위한 대학 내 시설 담당자들의 인식 조사)

  • Wee, Daehyun;Kim, Yoon Kyung;Choi, Jung Hyun
    • The Journal of the Korea Contents Association
    • /
    • v.14 no.12
    • /
    • pp.989-998
    • /
    • 2014
  • We examine the awareness of the facility managers in Korean universities and colleges over the global climate change and over the national greenhouse gas (GHG) energy target management program via a questionnaire survey. The result shows that the survey participants maintain high awareness on global and national issues including the climate change and the concept of the national GHG management framework. On the other hand, the responsibility of universities and colleges associated to these issues is not recognized as well, showing the necessity for further education. Additionally, important implications on the direction and the major factors that should be considered during the development of a GHG management program for universities and colleges are deduced from the result of the survey. In order to be effective in universities and colleges, a GHG management program must be able to estimate the present level of emissions accurately, to address campus-specific emissions characteristics, and to facilitate ease use for generic users. At the same time, active supporting services including education and promotion should be incorporated. The survey result can be utilized as basic data in guiding the future development of effective GHG management programs.

Methods to Reduce Greenhouse Gas for University Buildings to Make a Low-Carbon Green Campus - With Case Study on the 'E' University -

  • Song, Su Min;Peom, Sung Woo;Park, Hyo Soon;Song, Kyoo Dong
    • KIEAE Journal
    • /
    • v.14 no.2
    • /
    • pp.37-46
    • /
    • 2014
  • University buildings are energy-guzzling facility that consume more than 10,000TOE within a campus annually. Even the consumption is on an upswing trend. Behind such high consumption are there cheap power rates for education facility, lack of high-efficiency equipment and ever-increasing use of various information equipment. Being keenly aware that greenhouse gas emission increases due to such rise of energy consumption, the present study carried out a case study. In the case study, the study chose the buildings of E university from top 10 universities that consume energy most in Seoul and examined the current status of their energy consumption and greenhouse gas emission. And then it set the reduction target of greenhouse gas by year. Putting aside a middle and long-termed strategy for later endeavor, it first established the 1st year's implementation plan (2014) for energy saving and greenhouse gas reduction with limited budget and according to greenhouse gas reduction target. The plan is specified as follows. Targets for energy saving are mainly divided into two sectors: machine equipment and electric equipment. 7 ideas were proposed. Three ideas to improve machine equipment are to replace with high-efficiency boilers and chillers and to adjust the position of the cooling tower. By doing so, it was estimated that energy could be saved by 176.34TOE in total and greenhouse gas could be reduced by 370.771t$CO_2$-eq. Four ideas to improve electric equipment include the replacement with LED lights, LED emergency lights and high-efficiency motors and the installation of motion sensors. It was calculated that such replacement could conserve 1,076.08TOE (electric energy) and reduce 2,181.420t$CO_2$-eq (greenhouse gas).