• 제목/요약/키워드: Camera monitoring

검색결과 745건 처리시간 0.029초

Robot Posture Estimation Using Inner-Pipe Image

  • Sup, Yoon-Ji;Sok, Kang-E
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2001년도 ICCAS
    • /
    • pp.173.1-173
    • /
    • 2001
  • This paper proposes the methodology in image processing algorithm that estimates the pose of the pipe crawling robot. The pipe crawling robots are usually equipped with a lighting device and a camera on its head for monitoring and inspection purpose. The proposed methodology is using these devices without introducing the extra sensors and is based on the fact that the position and the intensity of the reflected light varies with the robot posture. The algorithm is divided into two parts, estimating the translation and rotation angle of the camera, followed by the actual pose estimation of the robot. To investigate the performance of the algorithm, the algorithm is applied to a sewage maintenance robot.

  • PDF

Tensile Characterization of Ceramic Matrix Composites (CMCs) with Nondestructive Evaluation (NDE) Techniques

  • Kim, Jeongguk;Lee, Joon-Hyun
    • 한국복합재료학회:학술대회논문집
    • /
    • 한국복합재료학회 2003년도 추계학술발표대회 논문집
    • /
    • pp.190-194
    • /
    • 2003
  • Two different types of nondestructive evaluation (NDE) techniques were employed to investigate the tensile behavior of ceramic matrix composites (CMCs). Two NDE methods, ultrasonic testing (UT) and infrared (IR) thermography, were used to assess defects and/or damage evolution before and during mechanical testing. Prior to tensile testing, a UTC-scan and a xenon flash method were performed to obtain initial defect information in light of UT C-scans and thermal diffusivity maps, respectively. An IR camera was used for in-situ monitoring of progressive damages. The IR camera measured temperature changes during tensile testing. This paper has presented the feasibility of using NDE techniques to interpret structural performance of CMCs.

  • PDF

CCD 카메라를 이용한 Ladle 열영상 관측시스템 (Monitoring System of Ladle Heat Image using CCD Camera)

  • 김태수;전중창
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2007년도 추계종합학술대회
    • /
    • pp.893-896
    • /
    • 2007
  • 본 논문에서 제안하는 시스템은 Ladle 나탕의 상태를 카메라를 사용하여 Ladle 탕면을 관측하고 획득한 영상데이터를 주조정장치로 보내게 되는데, 이러한 영상데이터를 보내기 위해서는 유선 송수신 방식은 Ladle의 회전 특성상 사용하지 못하므로 무선 송수신 방식을 사용한다. 또한 초고온 환경이므로 고온에 견딜 수 있도록 Housing 기술을 이용한 Dual 영상카메라 장착 관측시스템을 구축하고, 탕면 거리, 버블 영상 등을 통해 그 크기를 산출하는 알고리듬을 제안한다. 제안한 알고리듬에 따라 20분의 연주시간에 대하여 19.25Cm의 지름을 가친 Bubble의 크기를 계산할 수 있었다.

  • PDF

시각센서를 이용한 용접 Gap/Profile 모니터링 (Monitoring the Welding Gap/Profile with Visual Sensor)

  • 김창현;최태용;이주장;서정;박경택;강희신
    • 한국레이저가공학회:학술대회논문집
    • /
    • 한국레이저가공학회 2005년도 춘계학술발표대회 논문집
    • /
    • pp.3-8
    • /
    • 2005
  • The robot systems are widely used in the welding manufacturing. The essential tasks to operate the welding robot are the acquisition of the position and/or shape of the parent metal. For the seam tracking or the robot automation, many kinds of contact and non-contact of the system which monitors the shape of the welding part is described. This system uses the line-type structured laser diode and the visual sensor. It includes the correction of radial distortion which is often found in the image from the camera with short focal length. Direct Linear Transformation (DLT) is used for the camera calibration. The three dimensional shape of the parent metal is obtained after simple linear transformation. Therefore, the system operates in real time. Some experiments are carried out to evaluate the performance of the developed system.

  • PDF

Automated Detection of Cattle Mounting using Side-View Camera

  • Chung, Yongwha;Choi, Dongwhee;Choi, Heesu;Park, Daihee;Chang, Hong-Hee;Kim, Suk
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제9권8호
    • /
    • pp.3151-3168
    • /
    • 2015
  • Automatic detection of estrus in cows is important in cattle management. This paper proposes a method of estrus detection by automatically checking cattle mounting. We use a side-view video camera and apply computer vision techniques to detect mounting behavior. In particular, we extract motion information to select a potential mount-up and mount-down motion and then verify the true mounting behavior by considering the direction, magnitude, and history of the mount motion. From experimental results using video data obtained from a Korean native cattle farm, we believe that the proposed method based on the abrupt change of a mounting cow's height and motion history information can be utilized for detecting mounting behavior automatically, even in the case of fence occlusion.

시각 장애인을 위한 비디오 기반 보행거리 측정 (Video-based Walking Distance Measurement for the Visually Impaired)

  • 박수우;송병섭;도용태
    • 제어로봇시스템학회논문지
    • /
    • 제15권2호
    • /
    • pp.139-147
    • /
    • 2009
  • When the visually impaired walks inside a building like corridor, a GPS cannot be useful for the walker in estimating his or her position unlike the case of outdoor space. This paper presents two novel methods to measure the walking distance using a low cost camera worn on the chest of the visually impaired. In the first method we analyze the periodic variation of image focusing values. Walking steps are counted by checking the period for the rough measure of the walking distance. The second method counts the step number by monitoring fixtures on the ceiling, which have a certain interval. Lamps on the ceiling appeared on the video are monitored in this paper. The T-S fuzzy theory is used to detect lamps, and the walking steps are estimated by the positional variation of the lamp due to the gait of the walker. The two methods are tested in real experiment, and the results are compared.

PDA를 이용한 원격 제어 및 모니터링 시스템 (Remote Control and Monitoring System Using PDA)

  • 지양환;조용범;남부희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 C
    • /
    • pp.2465-2467
    • /
    • 2005
  • In this paper, we propose the system that can monitor and control the camera in the remote place using the PDA. The server PC attached to the PLC (Programmable Logic Controller) acquires the current status (On/Off) of the devices through the RS-232 serial communications. Also, the moving image frames captured from the wireless camera is compressed in the JPEG format and is stored in the server. The PDA, which is connected to the server through wireless internet, receives the data about the status of the devices and controls the devices according to the circumstances of them. Also, it can receive the images from the server simultaneously. So, we can monitor and control the specified area in the remote place using the PDA through the wireless communication.

  • PDF

적외선 모니터링 관측의 와이블 분포해석 (The Analysis of Weibull Distribution on the Monitoring of IRR Camera)

  • 임장섭;김진국;이학현;이진;이우선
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.264-267
    • /
    • 2004
  • The conventional testing as IEC-60587 is widely used in surface aging measurement of outside insulator those testing can carry out very short time in Lab testing. Also IEC-60587 testing is able to offer the standard judgement of relative degradation level of out side HV machine. Therefore it is very useful method compare to previous conventional tracking testing method and effective Lab testing method, But surface discharges(SD) have very complex characteristics of discharge pattern so it is required estimation research to development of precise analysis method. In recent, the study of IRR Camera is carrying out discover of temperature of power equipment through condition diagnosis and system development of degradation diagnosis.

  • PDF

Inspection of Calandria Reactor Surface of Wolsung Nuclear Power Plant using Thermal Infrared Camera mounted on the Mobile Robot KAEROT/m2

  • Cho, Jai-Wan
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2002년도 Proceedings of International Symposium on Remote Sensing
    • /
    • pp.578-578
    • /
    • 2002
  • Thermal infrared imaging is a highly promising technology for condition monitoring and predictive maintenance of electronic, electrical and mechanical elements in nuclear power plants. However, conventional low-cost infrared imaging systems suffer from poor spatial resolution compared to commercial CCD cameras. This paper describes an approach to enhance inspection performances for calandria reactor area of Wolsung nuclear power plant through the technique of superimposing thermal infrared image into real CCD image. In the occurrence of thermal abnormalities on observation points and areas of calandria reactor area, unusual hot image taken from thermal infrared camera is mapped upon real CCD image. The performance of the technique has been evaluated in the experiment carried out at Wolsung nuclear power plant in the overhaul period. The results show that localizations of thermal abnormalities on calandria reactor face can be estimated accurately.

  • PDF

변압기 온도 변화특성 모니터링 (Temperature Distribution Monitoring of Transformer)

  • 이우선;정찬문;손동민;서용진;임장섭
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 제4회 영호남학술대회 논문집
    • /
    • pp.69-72
    • /
    • 2002
  • The conventional thermal insulator and power transformer testing is widely used in surface aging measurement of outside insulator because those testing can carry out very short time in Lab testing. Also thermal testing is able to offer the standard judgement of relative degradation level of outside HV machine. There it is very useful method compare to previous conventional thermal testing method and effective Lab testing method. But surface discharges(SD) have very complex characteristics of discharge pattern so it is required estimation research to development of precise analysis method. In recent, the study of IRR-camera is carrying out discover of temperature of power equipment through condition diagnosis and system development of degradation diagnosis. In this study, thermal testing of power transformer is measured with partial temperature distribution in real time.

  • PDF