• Title/Summary/Keyword: Camera Capture

Search Result 326, Processing Time 0.02 seconds

Kinematical Analysis of Side Kick Motion in Taekwon Aerobics (태권에어로빅스 옆차기동작의 운동학적 분석)

  • Yoo, Sil
    • Korean Journal of Applied Biomechanics
    • /
    • v.18 no.3
    • /
    • pp.33-42
    • /
    • 2008
  • The purpose of this study was to analyze kinematic variables during Side kick motion in Taekwon Aerobics. The subjects of this study were the 7 skilled and 7 unskilled female college students. A QTM and an Auto Track were used to acquire raw data. The sampling rates camera was 100 Hz. The parameters were calculated and analyzed with Visual3D and SPSS 12.0. The results were as following; 1. In the elapsed time, there was no significance difference statically between a skilled and unskilled group. 2. In the cases of knee angle, there was significant difference statically at Maximum Knee Flexion2(p=0.046, F=4.925). 3. In the cases of knee angular velocity, there was significant difference statically at Maximum Knee Flexion1(p=0.031, F=5.940). 4. In the flexion/extension of hip angle, there was significant difference statically at Maximum Knee Flexion2(p=0.012, F=8.668). 5. In the abduction/adduction of hip angular velocity, there was significant difference statically at Minimum Knee Flexion (p=0.019, F=7.324). 6. In the external rotation/internal rotation of hip angular velocity, there was significant difference statically Minimum Knee Flexion(p=0.005, F=11.87).

Research and improvement of image analysis and bar code and QR recognition technology for the development of visually impaired applications (시각장애인 애플리케이션 개발을 위한 이미지 분석과 바코드, QR 인식 기술의 연구 및 개선)

  • MinSeok Cho;MinKi Yoon;MinSu Seo;YoungHoon Hwang;Hyun Woo;WonWhoi Huh
    • The Journal of the Convergence on Culture Technology
    • /
    • v.9 no.6
    • /
    • pp.861-866
    • /
    • 2023
  • Individuals with visual impairments face difficulties in accessing accurate information about medical services and medications, making it challenging for them to ensure proper medication intake. While there are healthcare laws addressing this issue, there is a lack of standardized solutions, and not all over-the-counter medications are covered. Therefore, we have undertaken the design of a mobile application that utilizes image recognition technology, barcode scanning, and QR code recognition to provide guidance on how to take over-the-counter medications, filling the existing gaps in the knowledge of visually impaired individuals. Currently available applications for individuals with visual impairments allow them to access information about medications. However, they still require the user to remember which specific medication they are taking, posing a significant challenge. In this research, we are optimizing the camera capture environment, user interface (UI), and user experience (UX) screens for image recognition, ensuring greater accessibility and convenience for visually impaired individuals. By implementing the findings from our research into the application, we aim to assist visually impaired individuals in acquiring the correct methods for taking over-the-counter medications.

Feasibility Study of the Real-Time IMRT Dosimetry Using a Scintillation Screen (고감도 형광판을 이용한 실시간 선량측정 가능성 연구)

  • Lim Sang Wook;Yi Byong Yong;Ko Young Eun;Ji Young Hoon;Kim Jong Hoon;Ahn Seung Do;Lee Sang Wook;Shin Seong Soo;Kwon Soo-Il;Choi Eun Kyoung
    • Radiation Oncology Journal
    • /
    • v.22 no.1
    • /
    • pp.64-68
    • /
    • 2004
  • Purpose : To study the feasibility of verifying real-time 2-D dose distribution measurement system with the scintillation screen for the quality assurance. Materials and Methods : The water phantom consisted of a scintillation screen (LANEX fast screen, Kodak, USA) that was axially located in the middle of an acrylic cylinder with a diameter of 25 cm. The charge-coupled device (CCD) camera was attached to the phantom In order to capture the visible light from the scintillation screen. To observe the dose distribution In real time, the intensity of the light from the scintillator was converted to a dosage. The isodose contours of the calculations from RTP and those of the measurements using the scintillation screen were compared for the arc therapy and the Intensity modulated radiation therapy (IMRT). Results : The kernel, expressed as a multiplication of two error functions, was obtained in order to correct the sensitivity of the CCD of the camera and the scintillation screen. When comparing the calculated isodose and measured isodose, a discrepancy of less than 8 mm in the high dose region was observed. Conclusion : Using the 2-D dosimetry system, the relationship between the light and the dosage could be found, and real-time verification of the dose distribution was feasible.

Study on the Differences in the Results of Body Shape Test According to the Position of the Two Feet and the Usefulness of the Neck and Body Motion Image Test (두 발의 위치에 따른 체형검사 결과 차이와 체간신전 동작 이미지 검사의 유용성 연구)

  • Chang, Wan Song;Kim, Song Ja;Ryu, Seo Won;Lim, Duk Joon;Jung, Moon Young
    • Journal of Naturopathy
    • /
    • v.9 no.1
    • /
    • pp.22-26
    • /
    • 2020
  • Purposes: The purposes of this study were to investigate the relationship between the standing position of the subject and the normal standing position(NSP) and the straight standing position(SSP) and to investigate the possibility of different body shape test results depending on the status of the image inspection apparatus. Methods: The images of the NSP and SSP were compared with each other by body line BLS system. Results: At the time of examination, the position of the camera was captured at a position 2.3 m vertically from the posterior position 45 cm behind the subject. This is a privacy protection method for covering the breast of the subject. Results: The physiological characteristics of the anatomical position of the body align image test are the living body. NSP and SSP tests showed different shapes of the pelvis AS(antero-supero) and pelvis rotation in the transverse plane. Shoulder and arm displacement was observed in the trunk extension image capture. Conclusions: In the body alignment test, the pelvis position test images of NSP and SSP are evaluated differently for pelvis rotation, AS, and PS. At the extension position of the trunk, a test of the maximal extension range showed that the left and right shortening of the shoulder anterior muscles could be observed. Inducing and testing the trunk extension is also useful.

A Case Study on Implementation of Mobile Information Security (모바일 정보보안을 위한 실시간 모바일 기기 제어 및 관리 시스템 설계.구현 사례연구)

  • Kang, Yong-Sik;Kwon, Sun-Dong;Lee, Kang-Hyun
    • Information Systems Review
    • /
    • v.15 no.2
    • /
    • pp.1-19
    • /
    • 2013
  • Smart working sparked by iPhone3 opens a revolution in smart ways of working at any time, regardless of location and environment. Also, It provide real-time information processing and analysis, rapid decision-making and the productivity of businesses, including through the timely response and the opportunity to increase the efficiency. As a result, every company are developing mobile information systems. But company data is accessed from the outside, it has problems to solve like security, hacking and information leakage. Also, Mobile devices such as smart phones belonging to the privately-owned asset can't be always controlled to archive company security policy. In the meantime, public smart phones owned by company was always applied security policy. But it can't not apply to privately-owned smart phones. Thus, this paper is focused to archive company security policy, but also enable the individual's free to use of smart phones when we use mobile information systems. So, when we use smart phone as individual purpose, the normal operation of all smart phone functions. But, when we use smart phone as company purpose like mobile information systems, the smart phone functions are blocked like screen capture, Wi-Fi, camera to protect company data. In this study, we suggest the design and implementation of real time control and management of mobile device using MDM(Mobile Device Management) solution. As a result, we can archive company security policy and individual using of smart phone and it is the optimal solution in the BYOD(Bring Your Own Device) era.

  • PDF

Enhancing the performance of the facial keypoint detection model by improving the quality of low-resolution facial images (저화질 안면 이미지의 화질 개선를 통한 안면 특징점 검출 모델의 성능 향상)

  • KyoungOok Lee;Yejin Lee;Jonghyuk Park
    • Journal of Intelligence and Information Systems
    • /
    • v.29 no.2
    • /
    • pp.171-187
    • /
    • 2023
  • When a person's face is recognized through a recording device such as a low-pixel surveillance camera, it is difficult to capture the face due to low image quality. In situations where it is difficult to recognize a person's face, problems such as not being able to identify a criminal suspect or a missing person may occur. Existing studies on face recognition used refined datasets, so the performance could not be measured in various environments. Therefore, to solve the problem of poor face recognition performance in low-quality images, this paper proposes a method to generate high-quality images by performing image quality improvement on low-quality facial images considering various environments, and then improve the performance of facial feature point detection. To confirm the practical applicability of the proposed architecture, an experiment was conducted by selecting a data set in which people appear relatively small in the entire image. In addition, by choosing a facial image dataset considering the mask-wearing situation, the possibility of expanding to real problems was explored. As a result of measuring the performance of the feature point detection model by improving the image quality of the face image, it was confirmed that the face detection after improvement was enhanced by an average of 3.47 times in the case of images without a mask and 9.92 times in the case of wearing a mask. It was confirmed that the RMSE for facial feature points decreased by an average of 8.49 times when wearing a mask and by an average of 2.02 times when not wearing a mask. Therefore, it was possible to verify the applicability of the proposed method by increasing the recognition rate for facial images captured in low quality through image quality improvement.