• Title/Summary/Keyword: Cam Wear

Search Result 68, Processing Time 0.022 seconds

Chip Load Control Using a NC Verification Model Based on Z-Map (Z-map 기반 가공 검증모델을 이용한 칩부하 제어기)

  • Baek Dae Kyun;Ko Tae Jo;Park Jung Whan;Kim Hee Sool
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.22 no.4
    • /
    • pp.68-75
    • /
    • 2005
  • This paper presents a new method for the optimization of feed rate in sculptured surface machining. A NC verification model based on Z-map was utilized to obtain chip load according to feed per tooth. This optimization method can regenerate a new NC program with respect to the commanded cutting conditions and the NC program that was generated from CAM system. The regenerated NC program has not only the same data of the ex-NC program but also the updated feed rate in every block. The new NC data can reduce the cutting time and produce precision products with almost even chip load to the feed per tooth. This method can also reduce tool chipping and make constant tool wear.

Effect of milling tool wear on the internal fit of PMMA implant interim prosthesis (밀링 공구의 마모가 PMMA 임플란트 임시보철물 변연 및 내면적합도에 미치는 영향)

  • Shin, Mi-sun
    • Journal of Technologic Dentistry
    • /
    • v.41 no.2
    • /
    • pp.63-69
    • /
    • 2019
  • Purpose: The purpose of this study is to evaluate the effect of CAD/CAM system milling tool wear on the marginal and internal fit of PMMA implant interim prosthesis three-dimensional manner. Methods: A total of 20 crowns were fabricated with CAD/CAM method. Their designs were unified to first molar of the left maxilla. The Customized abutments were prepared and scanned with on optical model scanner. Five crowns were milled by the newly replaced tool (1st milling), and 15 crowns were milled by 2nd, 3rd, 4th milling tool. The marginal and internal fit of 20 interim crowns were measured using the triple-scan protocol. Results: Statistically significant difference was found between the $1^{st}$ milling group ($51.8{\pm}14.6{\mu}m$) and the $3^{rd}$, $4^{th}$ milling group ($128.6{\pm}43.8{\mu}m$, $146.2{\pm}38.1{\mu}m$, respectively) at the distal margins. In the mesial margins, There was a statistically significant difference between the $1^{st}$ milling group ($63.6{\pm}25.9{\mu}m$) and the $3^{rd}$, $4^{th}$ milling group ($137.2{\pm}25.9{\mu}m$, $186.8{\pm}70.6{\mu}m$, respectively). In the distal line angle, significant difference was found between the $1^{st}$, $2^{nd}$, $3^{rd}$ milling groups and the $4^{th}$ milling group. In the mesial axial wall, significant difference was found between the $1^{st}$ milling group ($52.2{\pm}20.3{\mu}m$) and the $3^{rd}$, $4^{th}$ milling groups ($22.8{\pm}8.8{\mu}m$, $7.8{\pm}5.7{\mu}m$). Conclusion: As a result of the experiment, decrease of the marginal and internal fit was statistically significant as the number of machining cycles increased. In order to produce clinically excellent restorations, it is recommandable to consider the condition of the milling tool wear, when designing the restoration with CAD program.

Cutting Characteristics of Ball-end Mill with Different Helix Angle (볼 엔드밀 헬릭스 각에 따른 절삭 특성)

  • Cho, Chul Yong;Ryu, Shi Hyoung
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.31 no.5
    • /
    • pp.395-401
    • /
    • 2014
  • Development of five axis tool grinding machine and CAD/CAM systems increase tool design flexibility. In this research, investigated are cutting characteristics of ball-end mill with different helix angle. Special WC ball-end mills with $0^{\circ}$, $10^{\circ}$, $20^{\circ}$, $30^{\circ}$ helix angles are designed and used in various cutting tests. Machining performance according to helix angle variation is evaluated from cutting forces, surface roughness, tool wear, produced chip shape, and vibration characteristics. The ball-end mill with $10^{\circ}$ helix angle shows the best cutting performance due to appropriate chip load distribution and smooth chip flow. This research can be used for cutting edge geometry optimization and novel design of ball-end mill.

A Study on the Tappet Rotation in the Direct Acting Type OHC Valve Train System (직접 구동형 OHC 밸브 트레인 시스템의 태핏 회전에 관한 연구)

  • 한동철;김형준;조명래
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 1998.04a
    • /
    • pp.286-291
    • /
    • 1998
  • The aim of this paper is to measure the tappet rotation in OHC valve train system. Tappet is eccentric from the cam center to rotate for preventing the partial wear. The experimental system is developed to measure the tappet rotation by using the laser beam and optical fiber. The characteristics of tappet rotation is presented for various operating conctitions. Specially, it is observed that tappet is rotated at the base circle.

  • PDF

Detachment of Vane Tip in a Positive Displacement Vane Pump (베인 이간 현상에 관한 연구)

  • 문호지;조명래;한동철
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 1997.04a
    • /
    • pp.204-209
    • /
    • 1997
  • This paper reports on the theoretical study of the vane motions in a positive displacement vane pump. Vane detachment cause the pressure fluctuation, noise, wear in cam ring, and decrease the volumetric efficiency. Dynamic equation of vane motion and flow continuity equation have been modeled and solved simultaneously using 4th order Runge-Kutta method. As results of analysis, vane detachment occurs due to pressure overshoot by excess compression in the pumping chamber. Amount of vane detachment has been reduced by decreasing the pressure overshoot.

  • PDF

Full-mouth rehabilitation in an amelogenesis imperfecta patient with anterior open bite using CAD/CAM system (전치부 개방교합을 보이는 법랑질형성부전증 환자의 CAD/CAM system을 이용한 전악 수복 증례)

  • Lee, Sang-Hoon;Yi, Yang-Jin;Jo, Deuk-Won
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.55 no.4
    • /
    • pp.410-418
    • /
    • 2017
  • Amelogenesis imperfecta characterized as abnormally formed enamel is caused by a defect of unique group of genes. Patients affected by this disease might have difficulties in social and psychological aspects due to non-esthetic teeth as well as functional problems caused by enamel detachment and tooth wear from their early ages. Adult patients with amelogenesis imperfecta can be treated with full-mouth restorations, which make functional and esthetic rehabilitations of severely worn tooth. However, the anterior open bite and lack of occlusal clearance for posterior teeth restorations due to compensatory extrusion are the intervening factors in the prosthetic treatment. Therefore, the determination of anterior tooth lengths, vertical dimension, and anterior guidance should be set carefully. Recently, computer-aided design and computer-aided manufacturing (CAD/CAM) techniques help systematic approaches and enable dentists to reduce time-consuming procedures in the diagnosis and treatment of full-mouth rehabilitation. This case report demonstrates the successful full mouth rehabilitation using a CAD/CAM system in a young adult patient with amelogenesis imperfecta and anterior open bite.

Highly Reliable Triboelectric Rotational Energy Scavenger

  • Lee, Younghoon;Lee, Bada;Choi, Dukhyun
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2016.02a
    • /
    • pp.397-397
    • /
    • 2016
  • Triboelectric nanogenerators (TENG) can produce power from ambient mechanical sources and have strong points of high output performance, light weight, low cost, and easy manufacturing process. It is expected that TENG can be utilized in the fields of wireless electronics and self-powered devices in the world which pays attention to healthcare and the IoT. In this work, we focus on scavenging ambient rotational energy by using a durably designed TENG. In previous studies regarding harvesting rotation mode energy, the devices were based on sliding mechanism and durability was not considered as a major issue. However friction by rotation causes reliability problems due to wear and tear. Therefore, in this study, we convert rotary motion to linear motion utilizing a cam by which we can then utilize contact-mode TENG and improve device reliability. In order to increase output performance, bumper springs were used below the TENG and the optimum value for the bumper spring constant was analyzed theoretically. Furthermore, the inserting a soft substrate was proposed and its effect on high output was determined to be due to an increase in the contact area. By increasing the number of cam noses, the output frequency was shown to increase linearly. For the purpose of maximum power transfer, the input impedance of the device was determined. Finally, to demonstrate the use of the C-TENG as a direct power source, it was installed on a commercial bicycle wheel and connected to 180 LEDs. In conclusion we present a rotational motion TENG energy scavenger system designed for enhanced durability and optimized output by appropriate choice of spring constants and substrate.

  • PDF

The treatment of an edentulous patient with DENTCA$^{TM}$ CAD/CAM Denture (CAD/CAM Denture를 이용한 완전 무치악 환자 수복 증례)

  • Park, Joon-Ho;Cho, In-Ho;Shin, Soo-Yeon;Choi, Yu-Sung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.53 no.1
    • /
    • pp.19-25
    • /
    • 2015
  • Nowadays, CAD/CAM is broadly used in dentistry for inlays, crowns, implant abutments and its spectrum is expanding to complete dentures. Utilizing CAD/CAM to fabricate complete dentures is expected to decrease chair time and the number of visits, thus decreasing total fabrication time, expenses and errors caused during fabrication processes. One of the systems using CAD/CAM, DENTCA$^{TM}$ CAD/CAM denture (DENTCA Inc. Los Angeles, USA) scans edentulous impressions, designs dentures digitally, fabricates try-in dentures by 3D printing and converts them into final dentures. Patients can wear final dentures after only 2 - 3 visits with satisfying adaptation. This case report introduces a 71-year-old male patient who visited to consult remaking of existing old dentures. Residual teeth with bad prognosis and root remnants were extracted and the patient used reformed existing mandibular denture for 2 months. And then DENTCA system started. One-step border molding was done using conventional tray of adequate size provided by DENTCA system and wash impression was taken. Gothic arch tracing was completed based on the vertical dimension of existing dentures. Both maxillary and mandibular trays were placed to the resultant centric relation and bite registration was taken. Then DENTCA scanned the bite registration, arranged the teeth, completed the festooning and fabricated the try-in dentures by 3D printing. The try-in dentures were positioned, occlusal plane and occlusal relations were evaluated. The try-in dentures were converted to final dentures. To create bilateral balanced occlusion, occlusal adjustment was done after clinical remounting using facebow transfer. The result was satisfactory and it was confirmed by patient and operator.

Development of Dental Chewing Masticator (치과용 저작 매스티케이터의 개발)

  • Lee, Kwon-Yong;Jung, Il-Young;Park, Sung-Ho;Jeon, Seung-Beom
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 2002.05a
    • /
    • pp.255-258
    • /
    • 2002
  • Dental chewing masticator, which is an essential device for evaluating the wear of dental resin and the interfacial failure between the filling resin and enamel of tooth used in conservative dentistry, was developed. This dental chewing masticator mimics the chewing motion and loading by adapting DC motor and rotary cam system. Chewing loading of 49N was imposed by computer-displacement control, loadcell, LM guide, and spring system. Extracted tooth was fixed into a holding jig, and this jig was mounted with rubber pad on the $15^{\circ}$inclined surface to consider the lateral movement of periodontal ligament. A water bath was installed for providing the environment of inside mouth and for circulating the $5^{\circ}C-55^{\circ}C$ water to evaluate the effect of hydrothermal cycling on the damage of resin filled teeth during long-term chewing activity.

  • PDF

A survey on the needs of the garment manufacturing industry in Busan for the development of fashion major education program (패션전공 교육 개발을 위한 부산 의류제조 산업체 요구도 조사)

  • Kyung Ja Paek
    • The Research Journal of the Costume Culture
    • /
    • v.31 no.2
    • /
    • pp.213-227
    • /
    • 2023
  • To analyze the status and needs of the small- and medium-sized garment manufacturing industry in Busan, this study comprised an online survey of companies and interviews with 14 representatives of the 98 companies. The results are as follows: Approximately 34.7% of the garment manufacturers were located in Geumjeong-gu, Busan. The most common type of work was the contracting factory type. Daily production output was between 100pcs and 300pcs. Production materials comprised 42.9% woven and 24.8% knitted fabrics. Main products were menswear, uniforms, womenswear, casual wear, sports and leisure wear, protective clothes, and children's clothing. The main clients were uniform companies, main factories, wholesale markets, online shopping malls and promotion companies, exporters, and department stores. As a result of a survey on industrial needs with company representatives, their satisfaction with company employees was 57.2%, and the most important factor when hiring employees was job-related competencies, among which the ability to understand the sewing process was the most necessary. In terms of computer software literacy, illustrations and pattern CAD/CAM are required. They thought industry-university cooperation is crucial for advantage for advantage research and product development, as it allows for the sharing knowledge, resources, and especially human resources. The greatest administrative issue were human resources and funding.