• Title/Summary/Keyword: Cam Analysis

Search Result 592, Processing Time 0.036 seconds

A Study on the Cam Ring Deformation in a Balanced Type Vane Pump (유압 베인 펌프의 캠 링 변형에 관한 연구)

  • 한동철;조명래;양광식;박제승
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 1998.04a
    • /
    • pp.206-211
    • /
    • 1998
  • This paper presents the deformation characteristics of cam ring in a balanced type vane pump. Cam ring is operated in the condition of high pressure. Therefore the local deformation of cam ring affects the characteristics of compression, vane motion and noise and vibration. We analyzed the deformation of cam ring in three types by using the finite element method. As results of analysis, deformed shape of cam ring and the effects of deformation on the compression are presented.

  • PDF

A Study on Reverse Design of Cam Mechanism using NURBS (NURBS를 이용한 캠 기구의 역설계에 관한 연구)

  • 김상진;신중호;김대원;윤호업
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2002.10a
    • /
    • pp.920-924
    • /
    • 2002
  • This paper presents the reverse design of a cam mechanism using NURBS(Nonuniform Rational B-spline curve). Cam is very difficult to make the accurate shape on the design and the manufacture. Because the cam shape is commonly made in order to move in special functions. The reverse design can be used to check accuracy between the designed data and the manufactured data of the cam shape and also reproduce the cam without the design data. The reverse design procedures consist of motion analysis and curve fitting. The motion analysis is used the central difference method and the relative velocity method to find the displacement and velocity. The curve fitting is used NURBS to develope the whole curve. The central difference method is derived in the 3 dimensional space.

  • PDF

Research Trend Analysis of the Prevalence of Complementary and Alternative Medicine in Korea (국내 보완대체의학 사용 실태조사 연구의 동향 분석)

  • Kim, Sul-Gi;Lee, Sang-Hun;Seo, Hyun-Ju;Baek, Seung-Min;Choi, Sun-Mi
    • The Journal of Korean Medicine
    • /
    • v.33 no.1
    • /
    • pp.24-41
    • /
    • 2012
  • Objectives: This study reviewed research trends concerning the prevalence of complementary and alternative medicine (CAM) use and to suggest future research directions appropriate to medical circumstances in Korea. Methods: We searched for surveys of CAM use in 8 databases including 6 Korean databases, Ovid MEDLINE, and the CINAHL electronic database. Three independent reviewers working in pairs screened titles and abstracts of articles for eligibility. Full text was retrieved in case of disagreement on the eligibility. The main analysis targets included survey researcher's affiliation, terminology used in the title, study subject, definition of CAM, classifications of CAM modalities, and the area assortment of CAM and traditional Korean medicine (TKM). Results: 92 articles were included for analysis. The major constituent of affiliation was doctors (53%). According to years, study subjects were diversified to a large range of diseases. Since 2003, terminology is absorbed to use CAM. But actually, the most commonly used definition in the research was comprehensive such as "not generally considered part of major medicine" (55.4%) and the most used classification of CAM was self-criteria (61.9%). As for area assortment of CAM and TKM, many therapies exist in a gray zone between CAM and TKM. Conclusions: Standardized definition and classification criteria about CAM fit to the Korean healthcare system have not yet developed. For traditional Korean medicine academia, more concern should be paid to establishing appropriate development of definitions and classification criteria.

Specific Targeting of Fluorescein Isothiocyanate with Ep-CAM Antibody(Specific targeting of FITC with Ep-CAM Antibody)

  • Lee, Young-Tae;Tae, Gun-Sik
    • Journal of Photoscience
    • /
    • v.10 no.3
    • /
    • pp.237-240
    • /
    • 2003
  • The tetradecameric peptide (K47-K60) near the NH$_2$-terminal region of epithelial-cell adhesion molecule (Ep-CAM) was chosen as antigenic site and a polyclonal antibody was generated, which could recognize Ep-CAM from the mouse colon tissue or the colon cancer cell, CT-26, in Western blot analysis. Then, the fluorescein isothiocyanate (FITC), a fluorescence dye, was conjugated with the affinity purified Ep-CAM antibody using thiocyanate and the amino groups of FITC and antibody, respectively. The molar ratio of FITC to antibody was estimated approximately 1.86 to 1.00 by measuring the optical densities at 492 nm and 280 nm. Ep-CAM antibody-FITC conjugate was then used for immunohistochemistry of the CT-26 cells. Judging from the shapes formed by fluorescence, the Ep-CAM antibody could delivered FITC to the surface of cells in which Ep-CAM was expressed. This result implies that Ep-CAM antibody could be also used for the tissue-specific delivery of the photosensitizer to the target protein via antigen-antibody interaction.

  • PDF

Cam Profile Design for Precision Positioning (정밀위치결정을 위한 캠 형상 설계)

  • 이종호;이종길;김병희;전병희
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2003.05a
    • /
    • pp.204-209
    • /
    • 2003
  • Cam mechanisms are one of the most popular devices for generating intermittent motion and are widely used in many areas. Also, as being interested in research of precision field, cam mechanism is required high accuracy and continuity, In. In this paper, the cam mechanism of filament automatic assembly machine design for precision motion is proposed. The modelling of a cam mechanism, cam profile functions, and the design of the cam considering the precision positioning of the cam mechanism is studied. And, simulation of designed cam mechanism had been carried out dynamic analysis.

  • PDF

Optimum Design of Beating Cam for High Speed Rapier Loom (고속 래피어 직기용 바듸침 캠의 최적설계)

  • Kim, Jong-Su;Kim, Dae-Won
    • 연구논문집
    • /
    • s.28
    • /
    • pp.89-100
    • /
    • 1998
  • This paper deals with the design and analysis of a beating cam. The beating device of a high speed rapier loom, weaving fabric by completion of warp-weft patterns, is driven by double cam type on the same axis. As the double cam, coupled with two cams, performs the mutual conjugate motion, the double cam must be very preciously designed for smooth. For the shape design of a double cam, an instant velocity center method is proposed. This method can determine the cam profile from the contact conditions of the cam and roller follower and the velocity relationships at the instant velocity center. And the practical applicability was verified by developing “DISKCAM of a CAD program. As the results in this paper, the shapes of two cams, which are in the conjugate motion, are designed by instant velocity center method. We applied 8-order polynominals for the beating as displace¬ment curves for shape determination of double cams. The data of displacement, velocity, and acceleration of beating cam can be used adjust in accurate operation and to develope an advanced beating device.

  • PDF

Numerical Analysis of Piezocone Test using Modified Cam-Clay Model (Modified Cam-Clay Model을 이용한 피에조콘 시험의 수치해석)

  • Kim, Dae-Kyu;Lee, Woo-Jin
    • Journal of the Korean GEO-environmental Society
    • /
    • v.2 no.3
    • /
    • pp.89-99
    • /
    • 2001
  • In this study, the numerical analysis of piezocone penetration and dissipation tests has been conducted using the Modified Cam-Clay model, which is generally used in soil mechanics. The Modified Cam-Clay model and related mathematical equations in finite element derivation have been formulated in the Updated Lagrangian reference frame to take the large displacement and finite strain nature of piezocone penetration into consideration. The cone tip resistance, the pore water pressure, and the dissipation curve obtained from the finite element analysis have been compared and investigated with the experimental results from piezocone penetration test performed in Yangsan site. The numerical results showed good agreement with the experimental results; however, the better numerical simulation of the continuous and deep penetration needs further research.

  • PDF

CAD System Development for Geometric Design and Motion Analysis of Tangential Cam (접선 캠의 형상설계 및 운동해석을 위한 CAD시스템 개발)

  • 조성철;송정섭
    • Journal of the Korean Society of Safety
    • /
    • v.10 no.3
    • /
    • pp.42-46
    • /
    • 1995
  • To purpose of this study is to model design and motion analysis of tangential cam mechanism using personal computer system. The CAD(Computer Aided Design) system used in this study was constructed with CPU(Central Processing Unit) 80486, RAM(Random Access Memory) 8M, CGA graphic card. By using developed program for tangential cam mechanism, we designed tangential cam models and analysed displacement, velocity, acceleration of follower.

  • PDF

A Study on Development of the High Precision Cam Measurement Apparatus and Analysis of Cam Manufacturing Error (고 정밀 캠 측정 장치 개발 및 오차분석에 관한 연구)

  • Roh, Young-Hwa;Lee, Choon-Man
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.26 no.5
    • /
    • pp.112-119
    • /
    • 2009
  • Cam mechanisms are one of the most popular devices for generating irregular motion and are widely used in many automatic equipments, such as textile machinery, internal combustion engines and other automatic devices. In order to obtain the positive motion of follower by rotating cam, its shape should be correctly designed and manufactured. However, complex engineering tasks are required in a design and manufacturing of cams. And also, the manufacturing of general cam is demanded high costs. For the designing of cam, it must be decided that what kind of motion has to be transmitted to follower before selecting the curve of cam and designing profile of cam. However, even though the exact profile of cam is designed at the progress of design, if it doesn't have precision at the manufacturing progress, it's impossible to get expected result. We will develop cam simulation apparatus for measuring cam curve and get profile data before analyzing an error through comparison with design data of cam.

Changing Definitions of Complementary and Alternative Medicine and Related Research Analysis in Korea (보완대체의학의 정의 변화와 국내 관련 연구 분석)

  • Lee, Tae-Hyung;Kim, Nam-Il;Maeng, Woong-Jae
    • Korean Journal of Oriental Medicine
    • /
    • v.16 no.2
    • /
    • pp.43-55
    • /
    • 2010
  • Objective : There is a growing interest on Complementary and Alternative Medicine(CAM). But the term 'CAM' often causes confusion, for the perception of CAM is determined by how the relationship between CAM and Conventional Medicine is established. Methods : In this paper, we researched the concept of CAM through the change in the terminology and definition of CAM throughout history. Furthermore, we also analyzed related papers in Korea. Results : International studies show that the relationship between Conventional Medicine and CAM has become more cooperative. Meanwhile, in Korea, Korean Medicine is categorized as a type of Conventional Medicine, not CAM. Conclusion : Though Korean Medicine is included in Conventional Medicine in Korea, the research methodology is still restricted in ways of bio-medical science. Further study on the original research method of Korean Medicine is needed.