• Title/Summary/Keyword: Cam Analysis

Search Result 593, Processing Time 0.02 seconds

Analytical solution of stress-strain relationship of modified Cam clay in undrained shear

  • Silvestri, Vincenzo;Abou-Samra, Ghassan
    • Geomechanics and Engineering
    • /
    • v.1 no.4
    • /
    • pp.263-274
    • /
    • 2009
  • The modified Cam clay (MCC) model is used to study the response of virgin compressed clay in undrained compression. The MCC deviatoric stress-strain relationship is obtained in closed form. Elastic and plastic deviatoric strains are taken into account in the analysis. For the determination of the elastic strain components, both a variable shear modulus and constant shear modulus are considered. Constitutive relationships are applied to the well-known London and Weald clays sheared in undrained compression.

A Study on Definition of Integrative Medicine and Related Research Analysis in Korea (통합의학의 정의 고찰 및 국내 관련 연구 분석)

  • Lee, Taehyung;Lee, Byungwook;Kim, Namil
    • The Journal of Korean Medical History
    • /
    • v.23 no.2
    • /
    • pp.57-69
    • /
    • 2010
  • Objective: Interests in integrative medicine and CAM(Complementary and Alternative Medicine) are on the rise. However, the term 'integrative medicine' is often confused with the concept of CAM. This paper aims at clarifying the concept of integrative medicine. Methods: The definition, concept, and research methods used to explain integrative medicine have been inquired into. Also, the differences between the researches on integrative medicine and those on CAM have been studied. Moreover, domestic researches regarding integrative medicine have been analyzed. Results: The concept of integrative medicine was born in order to create a more patient-centered medicine by actively accommodating the medical system classified as CAM. The biggest difference that discriminates integrative medicine from CAM is the fact that integrative medicine does not depend solely on establishing its grounds through the process of RCT(Randomized Controlled Trial). Conclusion: Domestic researches regarding integrative medicine naturally leads to the concept of unification of medicine, but they do not concern the original meaning of integrative medicine. It is only after active discussions on the meaning, philosophical backgrounds, and research methods of integrative medicine become possible that a truly patient-oriented medicine will be realized.

A study on the Design of Drum Type Automatic Tool Changer (드럼형 자동공구교환장치의 설계에 관한 연구)

  • Choi, Hyun-Jin;Lee, Han-Gyu
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.19 no.7
    • /
    • pp.52-59
    • /
    • 2020
  • Automatic tool changers (ATCs) can be divided into drum and chain types. Drum-type ATCs contain a magazine, where the tools are mounted, and a cam gearbox, which swaps the tools via roller gear and grooved plate cams. Drum-type ATCs are advantageous in that the operating time for the tool magazine is more rapid than that of chain-type ATCs and the length of the unit is shorter. Thus, drum-type ATCs can be fabricated into various shapes and forms depending on the number of tools and the magazine size in accordance with machining center requirements and consumer demand. In particular, the price competitiveness of a machining center with a drum-type ATC is higher, while drum-type ATCs are more rigid with fewer parts, possibly reducing the need for regular servicing. This study aims to verify the structural stability and design validity of the magazine base, which is the main structure of a drum-type ATC, using finite element analysis. This study kinematically verifies the specifications of the selected drive motor and reducer and assessed the design of the cam gearbox. It also conducts a structural analysis of the roller camp, which is the core component of the cam gearbox, based on the results of the kinetodynamic analysis, thus validating the structural design.

THE LIGHT CURVE ANALYSIS OF AW CAM (AW CAM의 광도곡선 분석)

  • 김천휘;한원용
    • Journal of Astronomy and Space Sciences
    • /
    • v.12 no.1
    • /
    • pp.21-29
    • /
    • 1995
  • The $\beta$ Lyrae-type eclipsing binary AW Cam was observed photoelectrically in three wavelength regions. The obtained UBV light curves of AW Cam were analyzed with two separate modes(mode 2 for detached systems and mode 5 for semi-detached ones) of the Wilson-Devinney binary mode. It is intended to resolve the discrepancy in AW Cam system that the photometrio mass ratio (q=0.21) derived by Russo and Milano (1983) is not consistent with the spectroscopic result (q=0.43) by Mammano et al.(1967). Our photomtric solutions derived with mode 2 are fitted better to the observed light curves than those of mode 5, supporting that AW Cam may be not a normal semi-detached system but a detached one. Three dimensional Roche configuration of AW Cam system calculated with the derived mass ratio (q=0.43) reveals that the less massive secondary with the confined within its inner Roche lobe, while the more massive rimary is in marginally contact. From the Roche geometry, the constancy of the orbital period and other photometric evidences of AW Cam, it is provisionally concluded that the system is an unevolved detached binary in is provisionally concluded that the system is an unevolved detached binary in the phase of case A evolution toward 'contact phase' rather than and evolved one in 'broken-contact phase' suggested by Giuricin and Mardrossian (1981).

  • PDF

Behavior Characteristics of Embankment Foundation Based on Elasto-Viscoplastics Analysis (성토기초지반의 탄.점소성 거동 특성)

  • ;;Li Guang Fan
    • Journal of the Korea Institute of Building Construction
    • /
    • v.1 no.1
    • /
    • pp.151-159
    • /
    • 2001
  • This study was performed to investigate the effect of time-dependent creep on the deformation. In the analysis, modified Cam-Clay model was adopted to describe the elastic-plastic behavior of clayey soil. In order to consider effect of creep, the secondary coefficient of consolidation $\alpha$ was supplemented to modified Cam-Clay model. To examine the reliability of the program which is developed in this study, the estimated values by this program were compared with the experimental results. The results of the analysis were in good agreement with the observed values in the field.

  • PDF

A study on the Experimental Evaluation for the Cam Profile CNC Grinding Machine using Vibration Signals (진동 신호를 이용한 캠 프로파일 CNC 연삭기의 실험적 평가에 관한 연구)

  • Lee Choon Man;Lim Sang Heon
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2005.05a
    • /
    • pp.288-293
    • /
    • 2005
  • A earn profile grinding machine is a mandatory machine tool for manufacture of high precision contoured cam. Experimental evaluation of modal analysis is an effective tool to investigate dynamic behavior of a machine. This paper presents the measurement system and experimental investigation on the modal analysis of a grinding machine. The weak part of the machine is found by the experimental evaluation. The results provide structure modification data for good dynamic behaviors. And safety of the machine was confirmed by the modal analysis of modified machine design. Finally, the cam profile grinding machine was successfully developed.

  • PDF

MARGINAL FIT OF THE DIGIDENT CAD/CAM ZIRCONIA CERAMIC CROWNS

  • Kim Yong-Sun;Yang Jae-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.44 no.3
    • /
    • pp.275-283
    • /
    • 2006
  • Statement of problem. There have been many studies about marginal discrepancy of single restorations made by various systems and materials. However most of the statistical inferences are not definite because of sample size, measurement number, measuring instruments, etc, and there have been few studies about the marginal fit of the Digident CAD/ CAM zirconia ceramic crowns. Purpose. The purpose of this study was to compare the marginal fit of the anterior single restorations made by using the Digident CAD / CAM zirconia ceramic crowns with metal-ceramic restorations and to obtain more accurate information by using a large enough sample size and by making sufficient measurements per specimen. Material and Methods. The crowns were made from one extracted maxillary central incisor pre-pared with a 1mm shoulder margin and $6^{\circ}$ taper walls by milling machine. The in vitro marginal discrepancies of the digident CAD / CAM zirconia ceramic crowns and control groups(metal ceramic crowns) were evaluated and compared. Twenty crowns per each system were fabricated. Measurements of a crown were recorded at 50 points that were randomly selected for marginal gap evaluation. Parametric statistical analysis was performed for the results. Conclusion. Within the limitations of this in vitro study, the following conclusions were drawn: 1. Mean gap dimensions and standard deviations at the marginal opening for maxillary incisal crowns were $88{\pm}10{\mu}m$ for the control (metal-ceramic crowns), $92{\pm}4{\mu}m$ for Digident CAD / CAM zirconia ceramic crowns. 2. Marginal gap between Digident CAD / CAM zirconia ceramic crowns and metal ceramic crowns did not show significant difference (P>.05). 3. The Digident CAD/ CAM zirconia ceramic crowns and metal ceramic crowns showed clinically acceptable marginal discrepancy.

Comparison of CAD/CAM abutment and prefabricated abutment in Morse taper internal type implant after cyclic loading: Axial displacement, removal torque, and tensile removal force

  • Yi, Yuseung;Heo, Seong-Joo;Koak, Jai-Young;Kim, Seong-Kyun
    • The Journal of Advanced Prosthodontics
    • /
    • v.11 no.6
    • /
    • pp.305-312
    • /
    • 2019
  • PURPOSE. The purpose of this study was to compare computer-aided design/computer-aided manufacturing (CAD/CAM) abutment and prefabricated abutment in Morse taper internal connection type implants after cyclic loading. MATERIALS AND METHODS. The study was conducted with internal type implants of two different manufacturers (Group Os, De). Fourteen assemblies were prepared for each manufacturer group and divided into 2 groups (n=7): prefabricated abutments (Os-P, De-P) and CAD/CAM abutments (Os-C, De-C). The amount of axial displacement and the removal torque values (RTVs) were measured before and after cyclic loading (106 cycles, 3 Hz with 150 N), and the tensile removal force to dislodge the abutments was measured after cyclic loading. A repeated measures ANOVA and a pattern analysis based on the logarithmic regression model were conducted to evaluate the effect of cyclic loading on the axial displacement. The Wilcoxon signed-rank test and the Mann-Whitney test was conducted for comparison of RTV reduction% and tensile removal forces. RESULTS. There was no significant difference between CAD/CAM abutments and prefabricated abutments in axial displacement and tensile removal force; however, significantly greater RTV reduction% after cyclic loading was observed in CAD/CAM abutments. The correlation among the axial displacement, the RTV, and the tensile removal force was not significant. CONCLUSION. The use of CAD/CAM abutment did not significantly affect the amount of axial displacement and tensile removal force, but presented a significantly greater removal torque reduction% than prefabricated abutments. The connection stability due to the friction at the abutment-implant interface of CAD/CAM abutments may not be different from prefabricated abutment.

Six-year clinical performance of lithium disilicate glass-ceramic CAD-CAM versus metal-ceramic crowns

  • Ahmed Aziz;Omar El-Mowafy
    • The Journal of Advanced Prosthodontics
    • /
    • v.15 no.1
    • /
    • pp.44-54
    • /
    • 2023
  • PURPOSE. To assess the clinical performance of monolithic CAD-CAM lithium disilicate glass-ceramic (LDGC) crowns and metal-ceramic (MC) crowns provided by predoctoral students. This study also assessed the effects of patient and provider-related factors on their clinical performance as well as patient preference for these types of crowns. MATERIALS AND METHODS. Twenty-five patients who received 50 crowns (25 LDGC CAD-CAM and 25 MC) provided by predoctoral students were retrospectively examined. LDGC CAD-CAM crowns were milled in-house using the CEREC Bluecam system and cemented with either RelyX Unicem or Calibra Esthetic resin cements. MC crowns were cemented with RelyX Unicem cement. Clinical assessment of the crowns and the supporting periodontal structures were performed following the modified California Dental Association (CDA) criteria. Patients' preference was recorded using a visual analog scale (VAS). The results were statistically analyzed using log-rank test, Pearson Chi-squared test and Kaplan-Meier survival analysis. RESULTS. Twelve complications were observed in the MC crown group (9-esthetic, 2-technical and 1-biological). In comparison, 2 complications in the LDGC CAD-CAM crown group were observed (1-technical and 1-esthetic). The 6-year cumulative survival rates for MC crowns and LDGC CAD-CAM were 90.8% and 96%, respectively, whereas the success rates were 83.4% and 96%, respectively. Overall, patients preferred the esthetic outcomes of LDGC CAD-CAM crowns over MC crowns. CONCLUSION. The high survival and success rates, low number of complications, and the high level of patients' acceptance of monolithic LDGC CAD-CAM crowns lend them well as predictable and viable alternatives to the "gold standard" MC crowns.

Microscopical and chemical surface characterization of CAD/CAM zircona abutments after different cleaning procedures. A qualitative analysis

  • Gehrke, Peter;Tabellion, Astrid;Fischer, Carsten
    • The Journal of Advanced Prosthodontics
    • /
    • v.7 no.2
    • /
    • pp.151-159
    • /
    • 2015
  • PURPOSE. To describe and characterize the surface topography and cleanliness of CAD/CAM manufactured zirconia abutments after steaming and ultrasonic cleaning. MATERIALS AND METHODS. A total of 12 ceramic CAD/CAM implant abutments of various manufacturers were produced and randomly divided into two groups of six samples each (control and test group). Four two-piece hybrid abutments and two one-piece abutments made of zirconium-dioxide were assessed per each group. In the control group, cleaning by steam was performed. The test group underwent an ultrasonic cleaning procedure with acetone, ethyl alcohol and antibacterial solution. Groups were subjected to scanning electron microscope (SEM) analysis and Energy-dispersive X-ray spectroscopy (EDX) to verify and characterize contaminant chemical characterization non- quantitatively. RESULTS. All zirconia CAD/CAM abutments in the present study displayed production-induced wear particles, debris as well as organic and inorganic contaminants. The abutments of the test group showed reduction of surface contamination after undergoing an ultrasonic cleaning procedure. However, an absolute removal of pollutants could not be achieved. CONCLUSION. The presence of debris on the transmucosal surface of CAD/CAM zirconia abutments of various manufacturers was confirmed. Within the limits of the study design, the results suggest that a defined ultrasonic cleaning process can be advantageously employed to reduce such debris, thus, supposedly enhancing soft tissue healing. Although the adverse long-term influence of abutment contamination on the biological stability of peri-implant tissues has been evidenced, a standardized and validated polishing and cleaning protocol still has to be implemented.