• 제목/요약/키워드: Cam Analysis

검색결과 593건 처리시간 0.032초

CAD/CAM 전용 금속 합금과 주조용 합금의 세라믹 결합강도에 관한 연구 (A Study on the Metal-Ceramic Bond Strength of CAD/CAM Metal Disk Alloy and Casting Alloy)

  • 정효경;곽동주
    • 대한치과기공학회지
    • /
    • 제35권2호
    • /
    • pp.89-95
    • /
    • 2013
  • Purpose: The purpose of this study was to evaluate bond strength of Metal Disk alloy and casting alloy. Methods: Metal specimens were divided into 4 groups for each alloy. Three point flexural test were used to measure the bond strength of CAD/CAM metal alloy and casting alloy. Statistical analysis was done using the Statistical Package for Social Sciences version 19.0 for Windows. As for the analysis methods, the study used Kruskal-Wallis test. Results: The average bonding strengths of Group 1 to porcelain was $36.7{\pm}9.90$ MPa, Group 2 to porcelain was $37.68{\pm}4.51$ MPa, Group 3 to porcelain was $36.43{\pm}6.57$ MPa, Group 4 to porcelain was $42.88{\pm}6.81$ MPa, Each group was not significantly different. Conclusion: Bond strength of Casting alloy is equal to or higher than bond strength of CAD/CAM Metal Disk alloy. Alloy clinical bond strength is 25 MPa, So CAD/CAM Metal Disk alloy can be used as dental material.

Calcium Signaling-mediated and Differential Induction of Calmodulin Gene Expression by Stress in Oryza sativa L.

  • Phean-o-pas, Srivilai;Punteeranurak, Pornpimon;Buaboocha, Teerapong
    • BMB Reports
    • /
    • 제38권4호
    • /
    • pp.432-439
    • /
    • 2005
  • $Ca^{2+}$/calmodulin transduction pathways have been implicated in mediating stress response and tolerance in plants. Here, three genes encoding calmodulin (Cam) members of the EF-hand family of $Ca^{2+}$-binding proteins were identified from Oryza sativa L. databases. Complementary DNA for each of the calmodulin genes, OsCam1, OsCam2, and OsCam3 were sequenced. OsCam1 and OsCam2 encode a conventional 148-amino acid calmodulin protein that contains four characteristic $Ca^{2+}$-binding motifs. OsCam3 encode a similar protein with a 38-amino-acid extension containing a putative prenylation site (CVIL) at the carboxyl terminus. RT-PCR showed that each of the genes is expressed in leaves and roots of 2-week old rice seedlings. By RNA gel blot analysis, OsCam1 mRNA levels strongly increased in response to NaCl, mannitol and wounding treatments. In contrast, OsCam2 mRNA levels were relatively unchanged under all conditions investigated. NaCl treatment and wounding also increased the OsCam3 mRNA level, but in a more transient manner. Our results indicate that although the expression of genes encoding different calmodulin isoforms is ubiquitous, they are differentially regulated by various stress signals. In addition, we have demonstrated that the calcium-channel blocker lanthanum chloride inhibited the induction of OsCam1 gene expression by both NaCl and mannitol treatments. These results suggest that osmotic stress induced expression of OsCam1 gene requires the $[Ca^{2+}]_{cyt}$ elevation that is known to occur in response to these stimuli.

CAD/CAM 전문 인력 양성을 위한 교육 및 업무의 필요성 (The Need of Education and Practice to Bring Up CAD/CAM Experts)

  • 나정숙
    • 대한치과기공학회지
    • /
    • 제38권4호
    • /
    • pp.365-380
    • /
    • 2016
  • Purpose: The purpose of this study was to ascertain the need to reform curriculums for digital experts in a way that include the practical and educational aspects of dental labs by determining why educational reforms are needed to comply with changes in dental technology business that are brought by the applications of digital scanning and what changes are being actually brought by the use of CAD/CAM. Methods: This study analyzed the need of education and practice in relation to CAD/CAM by using the independent sample t-test and One-way ANOVA. in accordance with the participants demographic characteristics and job-related variables and factors related to CAD/CAM, and provided only some of the analysis results that were found statistically significant. Concerning the need of education and practice in relation to CAD/CAM, the study also used the independent sample t-test to measure difference in the perception of that need within each of the three groups, or those of job performance, job efficiency and knowledge gain at the signficance level of ${\alpha}=.05$. Results: Dental technologists surveyed here were perceiving that the use of CAD/CAM would bring changes in their job performance, job efficiency and knowledge gain. They were expecting that the biggest changes would be made in work climate and product quality as sub-areas of job performance. However, they said that in terms of job efficiency, the use of CAD/CAM would change job contribution, job satisfaction and job efficiency, but not lead to staffing. These results suggest that more special programs for CAD/CAM education are needed to bring up CAD/CAM experts who are more specialized. Conclusion: Among 13 skills related to CAD/CAM, what is most needed to be educated to dental technologists was "molding the occlusal surface" (M=4.19), followed by "designing the 3-D work" (M=4.17), "final shape modification" (M=4.16), "molding the border" (M=4.15) and "checking the fit of prothesis" (M=4.14) in order.

계란선별기 파커홀더 캠 개발 (Cam Design of Packer Holder in Egg Grading Machine)

  • 이장용
    • 대한기계학회논문집A
    • /
    • 제32권10호
    • /
    • pp.897-904
    • /
    • 2008
  • Egg grading machine is used in poultry raising industry to classify eggs by their weight and to pack up them. Packer holder mechanism is a main part of the egg grading machine, of which role is to take eggs fallen from conveyor belt, and afterward to transfer eggs vertically to mold tray. The vertical motion of packer holder is usually driven by slider-crank mechanism or cam. This paper describes development of the cam in packer holder based on kinematic analysis of packer holder mechanism and measurement of acceleration and noise of the cam to verify performance of it. Several cams that are designed and manufactured by the author of this paper according to different design specification are compared to determine the best solution for egg transfer in the packer holder mechanism.

무북직기용 Beating Cam 기구의 최적설계에 관한 연구 (A study on Optimum Design of Beating Cam Meachanism for Shuttleless Loom)

  • 김종수;신중호
    • 연구논문집
    • /
    • 통권22호
    • /
    • pp.75-83
    • /
    • 1992
  • The beating motion of a high speed shuttleless loom is driven by cams. Two cams become one system and their shaft laid across each other. Moreover, the shape of the cams is very complex and requires high precision for successful weft insertion and good interlacing with warp yarn. The iterative contact method is developed for use in design and analysis of the driving mechanism of a disk type cam with oscillating roller follower. The optimum design is performed by utilizing a CAD program, DISKCAM. The 8th order polynomial is selected to interpolate the desired shape trajectory of the cam, the optimal shape of the cams is defined based on the demension of the follower. The kinematic motion of the beating cam mechanism is investigated. The phase angle is determined to achive harmonious cam motions

  • PDF

치과 CAD/CAM 가공방식에 따른 임시보철물의 내면 적합도 : 3차원 중첩 분석 (Internal evaluation of provisional restorations according to the dental CAD/CAM manufacturing method : Three-dimensional superimpositional analysis)

  • 김재홍;김기백
    • 대한치과기공학회지
    • /
    • 제41권2호
    • /
    • pp.81-86
    • /
    • 2019
  • Purpose: The purpose of the present study was to compare the internal fit of two different temporary restorations fabricated by dental CAD/CAM system and to evaluate clinical effectiveness. Methods: Composite resin tooth of the maxillary first molar was prepared as occlusal reduction(2.0mm), axial reduction(1mm offset), vertical angle(6 degree) and chamfer margin for a temporary crown and duplicated epoxy die was fabricated. The epoxy dies were used to fabricate provisional restorations by CAD/CAM milling technique or 3D-printing technique. The inner data from all crowns were superimposed on the master die file in the 'best-fit alignment' method using 3D analysis software. Statistical analysis was performed using a Wilcoxon's rank sum test for differences between groups. Results: It showed that the internal RMS(Root Mean Square) values of the additive group were significantly larger than those of other group. No significant differences in internal discrepancies were observed in the temporary crowns among the 2 groups with different manufacturing method. Conclusion: All the groups had the internal fit within the clinical acceptable range (< $50{\mu}m$). The continuous research in the future to be applied clinically for the adaptation of additive manufacturing technique are needed.

박판판재 경화를 고려한 다이 캠 드라이브의 구조해석 최적화에 대한연구 (A Study on the Structure Analysis Optimization of Die Cam Drive Considering the Thin Plate Hardening)

  • 이종배;김선삼;우창기
    • 한국산학기술학회논문지
    • /
    • 제16권9호
    • /
    • pp.5769-5777
    • /
    • 2015
  • 프레스 가공에서 포밍이나 굽힘 등의 변형에 따라 판재는 가공경화를 발생하게 되며, 판재 경화와 가스 스프링 반력에 의한 캠 성형 과정에서 캠 및 판재의 변형과 미 성형이 발생하게 된다. 본 연구는 알루미늄 판재 성형 과정에서 판재경화를 고려한 응력, 변형이 주어진 판재 물성치와 캠 성형 압력에 맞게 입력 값으로 처리하였다. 그리고 유한요소 해석툴인 Hyperstudy와 Abaqus 연동으로 캠 형상을 비선형적으로 형상 최적화 해석을 수행 했다. 그 결과 판재의 변형이 제거 되면서 허용되는 최대, 최소 응력 범위와 최소 변형을 갖는 조건하에서 캠 형상을 최적화 하였다. 따라서 해석 결과를 통해 응력-변형 곡선과 응력-두께의 정규 분포도를 얻을 수 있었고, 또한 Iteration 처리로 판재 경화와 가스 스프링 반력을 고려한 다이캠 두께에 맞는 응력과 변형에 대한 최적화 형상을 얻을 수 있었다.

기초(基礎)아래 지반(地盤)의 거동에 대한 유한요소(有限要所) 해석(解析) (Finite Element Analysis on the Behavior of Soil under a Footing)

  • 이영생;김명모
    • 대한토목학회논문집
    • /
    • 제11권1호
    • /
    • pp.167-176
    • /
    • 1991
  • 본 연구에서는 기존의 구성 모델인 hyperbolic모델과 Cam-clay모델을 적용하는 유한요소해석 프로그램을 개발하였다. hyperbolic모델에서는, 전단중의 체적 변형을 고려하는 새로운 모델을 제시하였으며, 또한 기초 아래 지반의 밀도 증가로 인한 매개 변수값의 변화를 고려하는 새로운 개념을 제안하고자 했다. 이와 더불어 보다 타당하다고 생각되는 계산 알고리즘을 제안하였다. 또한 Cam-clay모델을, 연구 사례가 많지 않은 모래질 흙에 적용함으로써 모래질 흙의 거동을 한계 상태 개념의 관점에서 분석해 보고자 하였다. 이를 위해 일반적인 압밀 배수 삼축 압축 시험과 모형 기초 재하 실험을 실시하였다. 그 결과, 본 논문에서 제안한 수정 hyperbolic모델을 사용함으로써 기존 모델보다, 기초에 작용하는 하중의 크기가 극한 지지력의 50%일때, 기초의 침하량 예측에 있어서 약 60% 정도, 결과의 향상을 기할 수 있었다. Cam-clay모델을 모래에 적용하는 경우에는 과압밀 효과를 고려할 수 있는 모델 및 변형률 연화를 고려할 수 있는 계산 알고리즘이 필요하다고 생각된다. 초기 포아송비의 크기는 Cam-clay모델의 경우 결과에 큰 영향을 미치지 않았으나, hyperbolic모델의 경우 결과에 큰 영향을 미치므로, 초기값의 선정에 신중하여야 함을 알 수 있다.

  • PDF

보완대체요법의 국내외 연구 동향 비교 (Research Trend of Complementary and Alternative Medicine)

  • 오가실;김금순;권소희;박지원
    • 대한간호학회지
    • /
    • 제36권5호
    • /
    • pp.721-731
    • /
    • 2006
  • Purpose: This study was done to describe the research trend of Complementary and Alternative Medicine(CAM) in Korea and internationally. Method: A Systematic review of CAM related literature published from 2000 to 2005 was done. A comprehensive search by using 34 CAM modalities as search terms to identify all articles dealing with CAM was undertaken from 4 databases: PubMed, RICHIS, KoreaMed, and Riss4U. A Total of 588 abstracts and 223 original articles were reviewed by two independent reviewers using systematic analysis guidelines. Data regarding the types of study design, characteristics of subjects and researchers, and classification of CAM modalities was recorded. The outcome measures of CAM were identified. Results: CAM research has been rapidly increasing worldwide in the last decade. In Korea, nursing(53.5%) followed by medicine(42.7%) occupied the majority of CAM research in comparison to medicine(42.9%) and disciplines in CAM(25.0%), like homeopathy, internationally. Prevailing research designs in Korea were experimental and quasi-experimental, however, randomized clinical trials were found. Internationally, survey research was dominant, with the exception of randomized clinical trials that were mostly an experimental design. Conclusion: The findings suggest that a robust research design in CAM research is needed to accumulate strong scientific evidence and to adopt nursing interventions from CAM modalities.

Comparative fracture strength analysis of Lava and Digident CAD/CAM zirconia ceramic crowns

  • Kwon, Taek-Ka;Pak, Hyun-Soon;Yang, Jae-Ho;Han, Jung-Suk;Lee, Jai-Bong;Kim, Sung-Hun;Yeo, In-Sung
    • The Journal of Advanced Prosthodontics
    • /
    • 제5권2호
    • /
    • pp.92-97
    • /
    • 2013
  • PURPOSE. All-ceramic crowns are subject to fracture during function. To minimize this common clinical complication, zirconium oxide has been used as the framework for all-ceramic crowns. The aim of this study was to compare the fracture strengths of two computer-aided design/computer-aided manufacturing (CAD/CAM) zirconia crown systems: Lava and Digident. MATERIALS AND METHODS. Twenty Lava CAD/CAM zirconia crowns and twenty Digident CAD/CAM zirconia crowns were fabricated. A metal die was also duplicated from the original prepared tooth for fracture testing. A universal testing machine was used to determine the fracture strength of the crowns. RESULTS. The mean fracture strengths were as follows: $54.9{\pm}15.6$ N for the Lava CAD/CAM zirconia crowns and $87.0{\pm}16.0$ N for the Digident CAD/CAM zirconia crowns. The difference between the mean fracture strengths of the Lava and Digident crowns was statistically significant (P<.001). Lava CAD/CAM zirconia crowns showed a complete fracture of both the veneering porcelain and the core whereas the Digident CAD/CAM zirconia crowns showed fracture only of the veneering porcelain. CONCLUSION. The fracture strengths of CAD/CAM zirconia crowns differ depending on the compatibility of the core material and the veneering porcelain.