• Title/Summary/Keyword: Calorimeter

Search Result 729, Processing Time 0.034 seconds

Measurement of Calorific Value Using Flame Calorimeter (전자 소자를 이용한 연소열 측정)

  • Lim, Ki-Won;Jun, Jin-Young;Lee, Byeong-Jun
    • Journal of the Korean Society of Combustion
    • /
    • v.15 no.3
    • /
    • pp.40-47
    • /
    • 2010
  • Calorific value of mixed gas, like liquefied natural gas (LNG), is strongly depends on its compositions which are affected by the mining place and producing time. The variation in calorific value have an direct influence on the combustion characteristics and performances of boiler, burner, vehicle, power plants etc. Thus, developing experimental method to measure exact calorific value is becoming an issue in the related industrial fields. Flame calorimeter is developed to get calorific value at the dynamic equilibrium state using electric substitution method. Refrigerant-11 carries heat from combustor and/or heater to the Peltier elements which pumped it out to the cooling water. It is found out that error in the measured calorific value of methane is 2.86% compared with the theoretical one. Developed design technique and the experimental data will be applied to design the national standard gas calorific value measuring apparatus.

A Study on the Fire Risk Assessment of EIFS by Cone Calorimeter Test & Single Burning Item Test (중소형화재실험을 이용한 외단열 시스템(EIFS) 화재위험성평가에 관한 연구)

  • Min, Se-Hong;Kim, Mi-Suk
    • Journal of the Korea Safety Management & Science
    • /
    • v.12 no.1
    • /
    • pp.1-9
    • /
    • 2010
  • Recently, in circumstantial situation it is recommended positively to utilize of EIFS(Exterior Insulating and Finishing System) as energy policy for economizing energy. But internal EPS insulators of EIFS are exterior panel of high fire risk, because of constituting of flammable materials to be fragile in fire. In this study, fire risk is assessed by experiment Con Calorimeter test and SBI(Single Burning Item) test. As the result of experiment, Con Calorimeter tests do not reach to capability standard of internal incombustible grade, and are assessed as low grade in SBI incombustible grade. Because EIPS is exterior material in buildings with high fire risk in spite of good efficiency, it is required rapidly to take measures to meet situation through various studies(for instance, adjusting law regulation, etc.) in the future.

Cooling Performance Analysis of Sub-scale Calorimeter (축소형 칼로리미터의 냉각성능 해석)

  • 조원국;문윤완
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2003.05a
    • /
    • pp.9-12
    • /
    • 2003
  • A cooling performance analysis has been made in the 8-channel calorimeter based on sub-scale KSR-III engine. Three-dimensional heat transfer analysis in cooling channels has been performed using the heat flux distribution through the chamber wall predicted from axi-symmetric compressible flow inside the combustion chamber. The heat flux distribution was verified against the published literature. Presented for the development and operation of the calorimeter are the coolant pressure drop, coolant temperature rise and the maximum chamber wall temperature.

  • PDF

Morphological, Thermal and Dynamic Mechanical Properties of Polyurethane Product with Various Contents of Acrylic Polyol (Acrylic Polyol 함량을 달리한 폴리우레탄 제품의 형태학적 열적 및 동적·기계적 성질)

  • Kim, Tae Sung;Park, Chan Young
    • Elastomers and Composites
    • /
    • v.48 no.4
    • /
    • pp.276-281
    • /
    • 2013
  • Polyester type polyurethane foam modified with acrylic polyol was prepared by quasi prepolymer method. Thermal and dynamic mechanical properties of polyurethane foam were analysed by thermal gravimetric analysis(TGA) and dynamic mechanical analysis(DMA). Also, glass transition temperature was measured by differential scanning calorimeter(DSC). As acrylic polyol contents were increased, thermal stability measured by TGA was slightly decreased. Storage modulus was increased and tan delta was decreased with increasing of acrylic polyol contents.

An Experimental Study on the Measurement Error in the Performance Testing of Air Conditioners Using a Psychrometric Calorimeter (건습구식 칼로리미터를 이용한 공기조화기 성능측정상의 계측오차에 대한 실험적 연구)

  • 김봉훈
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.14 no.5
    • /
    • pp.415-423
    • /
    • 2002
  • An experimental study using a psychrometric calorimeter was conducted to investigate the temperature and pressure mea surement errors permitted for determining cooling capacity of an air conditioner. First, the instrument calibration was made in accordance with the related test methods and guidelines in order to accurately evaluate basic performance (cooling capacity and airs flow rate). Secondly, a parametric study was performed to examine the effect of measurement error involved if temperature and pressure measuring instruments on the cooling capacity calculation. From the results, it was found that the degree of accuracy for both temperature and pressure measurements played an important role on the error occurring in the determination of cooling capacity and needed to be maintained within a certain value to guarantee required accuracy of cooling capacity.

Fire Simulation by Pyrolysis Method of FDS for the Small Cone Calorimeter (ISO 5660) (FDS 열분해 모델을 이용한 콘칼로리미터(ISO 5660) 화재 시뮬레이션)

  • Yang, Sung-Jin;Jang, Jung-Hun;Kang, Chan-Yong
    • Proceedings of the KSR Conference
    • /
    • 2009.05a
    • /
    • pp.206-212
    • /
    • 2009
  • Chemical behaviors of each surface material for interior facilities affect to fire initiation and growth in general fire situation. These chemical behaviors were characterized by thermal properties (Heat release rate, Pyrolysis rate, specific heat, etc) which could be derived from experimental test. Especially, Heat release rate which indicates aspect of fire size is one of the most important property to asses fire hazard and protection needs. The cone calorimeter test (ISO 5660) has recently assumed to a dominant role in bench scale fire testing to obtain the Heat release rate of materials. This value could be calculated by the 'Oxygen Consumption Method' under various producing irradiances to each surface of materials. In this study, Process of the cone calorimeter test was simulated by Pyrolysis model of FDS (Fire Dynamics Simulator by NIST) base on the ISO 5660 international standard. Then, we could estimate the simulation method of FDS in case of single materials through the comparative study with test results.

  • PDF

A Experimental Study on the Fire Hazard Analysis For Communication Cable in Buildings (건축물내 통신용 케이블의 화재위험성 분석에 관한 실험연구)

  • Hong, Sung-Ho;Choi, Moon-Soo
    • Journal of the Korean Society of Safety
    • /
    • v.26 no.6
    • /
    • pp.20-25
    • /
    • 2011
  • This study presents on the fire hazard analysis of communication cable in buildings. In order to analyze fire hazards for communication cable IEC 60332-1, UL 94 and cone calorimeter test are conducted. The number of cable used to experiment is 10 communication cable which are generally applied to data communication in buildings. The results show that 9 cables do meet the performance requirement of IEC 60332-1 and 8 cables are V-0 classification. IEC 60332-1 and UL 94 test are inadequate for fire hazard classification. The various parameters obtained by cone calorimeter test such as HRR, peak HRR, smoke production rate and so on. Also it is able to evaluate multiply fire hazard for communication cable with cone calorimeter test results.

Experimental and Numerical Analysis of a Simple Core Loss Calculation for AC Filter Inductor in PWM DC-AC Inverters

  • Lee, Kyoung-Jun;Cha, Honnyong;Lee, Jong-Pil;Yoo, Dong-Wook;Kim, Hee-Je
    • Journal of Power Electronics
    • /
    • v.13 no.1
    • /
    • pp.113-121
    • /
    • 2013
  • This paper introduces a simple core loss calculation method for output filter inductor in pulse width modulation (PWM) DC-AC inverter. Amorphous C-core (AMCC-320) is used to analyze the core loss. In order to measure core loss of the output filter inductor and validate the proposed method, a single-phase half-bridge inverter and a calorimeter are used. By changing switching frequency and modulation index (MI) of the inverter, core loss of the AMCC-320 is measured with the lab-made calorimeter and the results are compared with calculated core loss. The proposed method can be easily extended to other core loss calculation of various converters.

An Experimental Study on the Fire Behavior of Fixed Combustibles in residential facilities Using The Cone Calorimeter (Cone Calorimeter를 활용한 주거시설의 고정가연물 연소특성에 관한 실험)

  • Pyo, Geun-Tae;Kim, Nam-Hyuk;Shin, Yi-Chul;Kwon, Young-Jin
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2010.10a
    • /
    • pp.275-278
    • /
    • 2010
  • 최근 주거시설의 내장재는 다양화 되어 가고 있지만 안정성 보다는 디자인, 기능성에 치중되어 그에 따른 화재 위험성도 커져가고 있다. 또한 여러 가지 합성수지로 예상치 못한 화재성상을 보이고 있으나 이에 따른 법규는 미비한 실정이다. 따라서 본 연구는 고정가연물중 주거시설에서 많이 사용되어지는 시료를 선정하여 Cone Calorimeter를 이용해 그 연소특성을 알아보았다. 그에 따른 결과로 바닥재는 국내산이 높은 발열량을 보였고 벽지는 국외산이 높은 발열량을 보였다.

  • PDF

Development of the Calorimeter to Measure Heat Rate Generated from Battery for EV & HEV (전기자동차용 축전지의 발열량 측정을 위한 열용량계 개발)

  • Yang Cheol-Nam;Park Seong-Yong
    • Journal of the Korean Electrochemical Society
    • /
    • v.2 no.4
    • /
    • pp.218-220
    • /
    • 1999
  • The performance of the Electric Vehicle and Hybrid Electric Vehicle depends on that of the battery pack composed of series connected batteries. And thermal property is one of the main factors which decide the performance of the battery pack. So heat generation rate from the battery under the various driving mode must be measured as precise as possible because thermal characteristics of the battery affect the driving performance and battery pack's life cycle. Besides, to design and develop the battery thermal management system for the EV and HEV, the measurements of the thermal properties of the batteries are needed. However, the established calorimeter is not adequate to test an EV's battery because its cavity is too small to accommodate the EV's battery. Therefore we developed the calorimeter to test the thermal property of the EV's battery. Its cavity size is 120mm long, 75mm wide and 200mm high. The calorimeter is calibrated by the dummy cell which generates the heat rate from zero to 200W. The measuring accuracy of the calorimeter is within $2\%$ and its voltage stability is 2.5mV in the constant temperature bath.