• Title/Summary/Keyword: Caliper

Search Result 244, Processing Time 0.027 seconds

The Effect of Microcurrent Stimulation on Wound Healing in Rat (미세전류전기자극이 흰쥐의 창상치유에 미치는 영향)

  • Oh, Hye-Jin;Kim, Jung-Woo;Park, Jang-Sung
    • Journal of the Korean Academy of Clinical Electrophysiology
    • /
    • v.6 no.1
    • /
    • pp.43-55
    • /
    • 2008
  • The purpose of this study was to investigate the effect of microcurrent stimulation intensity($50{\mu}A,\;100{\mu}A,\;300{\mu}A$ - 5 pps pulse frequency was same) on wound healing in rat. Sixty male Korean rats were randomly divided into 4 groups of 15 for 4 different treatment protocols(none-control group, $50{\mu}A,\;100{\mu}A,\;300{\mu}A$ experimental groups). Experimental 20 mm linear wound were made and all animals in the experimental groups were received microcurrent stimulation once a day for 20 minutes until sacrifice days(1st day, 3rd day, 6th day). A vernier caliper was used to measure a wound healing length and an optical microscope was used to determine any histological changes. The repeated measures two-way ANOVA was used for statistical differences in wound healing length. Experimental results were as follows: 1. In the examination with the naked eye, all groups showed similar changes until 1st day. But from 3rd day, a little intercellular fluid soaked through wound region in control group. In experimental groups, little intercellular fluid soaked through wound region, and swelling and redness did not appear. 2. Wound length of experimental $50{\mu}A$ group was significantly decreased than control group(p<0.001). And in the aspect of application period, wound length was significantly decreased in 3th, 6th day than 1st day and 6th day than 3th day (p<0.001). In conclusion, it has been found that the microcurrent stimulation had a positive effect on wound healing. And $50{\mu}A$ stimulation intensity was more effective than other intensities($100{\mu}A,\;300{\mu}A$) in wound healing. Also, low-intensity microcurrent stimulation was more effective on the purpose of wound healing.

  • PDF

A Study on the Measures to Improve the Assessment Method for Loss Compensation of Landscape Plants (조경수의 손실보상 감정평가 개선에 관한 연구)

  • Park, Yool-Jin;Lim, Yoen-Hong
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.20 no.3
    • /
    • pp.19-31
    • /
    • 2017
  • Plants are the basis for sustainable green growth, and the value of existence and importance of trees including landscape Plants can't be emphasized enough. Therefore, they are precious living things thriving in all sorts of public services, and continuous civil complaints for justifiable compensation of landscape Plants are filed. First, the standard formula of planting intervals according to production target specifications is calculated using root-collar caliper and diameter at breast height, and apply (1) standard medium sized trees which have not yet reached commercialization [deciduous tree production goal (R(B) less than 6cm]= (target standard)= [target standard $R(cm){\times}15{\times}0.7$]. (2) In case of commercialization(R6~R10)= [target standard $R(cm){\times}15{\pm}5%$], (3) In case of more than R12= [target standard $R(cm){\times}15{\times}130%$] shall be applied. In case of using diameter at breast height (4) In case of commercialization(B6~B10)= [target standard $B(cm){\times}20{\times}15{\pm}5%$], (5) In case of more than B12= [target standard $B(cm){\times}20{\times}130%$] shall be applied. Second, appraisal methods based on tree classification of compensation for loss are classified according to planted locations. (1) landscape trees within a house=[price of arrival at the site+planting cost], (2) landscape trees in places such as arboretum=[management technology of tress + relocation expenses considering scarcity of the trees (3) landscape trees in a place of loads= [landscape tree production cost + work out added price. In case of producted landscape threes (4) landscape trees ready to be commercialized as sales loss.

In vitro comparison of the cyclic fatigue resistance of HyFlex EDM, One G, and ProGlider nickel titanium glide path instruments in single and double curvature canals

  • Yilmaz, Koray;Uslu, Gulsah;Ozyurek, Taha
    • Restorative Dentistry and Endodontics
    • /
    • v.42 no.4
    • /
    • pp.282-289
    • /
    • 2017
  • Objectives: It was aimed to compare the cyclic fatigue resistances of ProGlider (PG), One G (OG), and HyFlex EDM (HEDM) nickel titanium glide path files in single- and double-curved artificial canals. Materials and Methods: 40 PG (16/0.02), 40 OG (14/0.03), and 40 HEDM (10/0.05) single-file glide path files were used in the present study. Sixty files were subjected to cyclic fatigue test by using double-curved canals and 60 files by using single-curved canal (n = 20). The number of cycles to fracture (NCF) was calculated and the length of the fractured fragment (FL) was determined by a digital micro-caliper. Twelve pieces of fractured files were examined with scanning electron microscope to determine fracture types of the files (n = 2). The NCF and the FL data were analyzed using one-way analysis of variance and post hoc Tukey test using SPSS 21 software (p < 0.05). Results: In all of the groups, NCF values were significantly lower in double-curved canals when compared to single-curved canals (p < 0.05). For both of single- and double-curved canals, NCF values of HEDM group in apical and coronal curvatures were found to be significantly higher than NCF values of PG and OG groups (p < 0.05). In both of single- and double-curved canals, NCF value of PG group was found significantly higher than OG group (p < 0.05). Conclusions: Within the limitations of this study, HEDM glide path files were found to have the highest cyclic fatigue resistance in both of single- and double-curved canals.

Reliability and Accuracy of Digital Impression Obtained from CS-3500 Intraoral Scanner (CS-3500 구강 내 스캐너로 채득된 디지털 인상의 신뢰도 및 정확도 평가)

  • Kim, Sa-Hak;Kim, Jae-Hong;Kim, Chong-Kyen
    • Journal of dental hygiene science
    • /
    • v.15 no.5
    • /
    • pp.673-678
    • /
    • 2015
  • The purpose of this study was to evaluate the reliability and accuracy of linear measurements in digital models compared to master model. A master model (ANKA-4; Frasaco GmbH, Tettnang, Germany) with the prepared upper full arch tooth was used. Four linear measurements were recorded between landmarks, directly on the master model and the digital models by a single examiner. Measurements were made with a digital caliper from manual model and with the software from the virtual models. The t-test for paired samples and intraclass correlation coefficient (ICC) were used for statistical analysis. The measurement of two methods showed good reliability. The mean differences between master and digital model were 0.06~0.12 mm. These in vitro studies show that accuracy and reliability of the digital impression is similar to that of the gold standard. Therefore digital impression was also considered to be a acceptable for placement clinically.

High Resolution Borehole Acoustic Scanner (Televiewer) (고분해능 텔레뷰어 검층기법의 기능)

  • ;Schepers,R
    • The Journal of Engineering Geology
    • /
    • v.5 no.3
    • /
    • pp.277-288
    • /
    • 1995
  • Fracture detection has always been very attractive to the log, because it is important in many of our prospecting activities, e.g. in understanding the underground rock formation and also the fluid flow as a high permeability path. This paper demonstrates the use of high resolution borehole acoustic scanner for the detection of fractures. The tool, known as Televiewer, is the first acoustic borehole imaging system to use a focussed beam. The acoustic beams generated by a single transducer are sent toward the borehole wall, scanning the wall in a tight helix as the tool moves along the borehole. The amplitudes and travel times of the reflected signals are then measured, which produces the corresponding images. The highly resolved amplitude image allows to recognize various size of fractures and in addition to derive the rock strength from the image. Meanwhile, the travel time image itself can be directly converted to a precise caliper image, providing detailed information of deviations of the borehole shape. It also allows correction of and explanations for amplitude variations. Field measurements were carried Out at the Cheongyang study sites in Korea to illustrate the efficiency of the televiewer log.

  • PDF

Changes in Nutritional Status of General Medical Patients During Hospitalization (내과 환자의 입원후 영양상태 변화 연구)

  • 양영희;최스미;김은경
    • Journal of Korean Academy of Nursing
    • /
    • v.27 no.1
    • /
    • pp.49-60
    • /
    • 1997
  • The purpose of this study was to determine the incidence of malnutrition among patients on admission to hospital, to monitor changes in their nutritional status during hospitalization, and to determine the factors which might affect changes in nutritional status. The subjects for the study were patients who were admitted to general medicine for more than one week. Patients suffering from cardiovascular. renal disease, or dehydration were excluded. Nutritional assessment of the patients was performed on admission and nutritional status was reassessed one week and two weeks after admission. The nutritional assessment tool consisted of subjective history taking and anthropometric measurements. Biochemical measurements were performed only on admission. For anthropometric assessment : patients' body weight, subcutaneous skinfolds thickness, % of body fat, body mass index, and lean body mass were measured using caliper or Bio impedance Analyzer. Factors which might influence current nutritional status, like dietary intake, anorexia, nausea, vomiting, diarrhea, sleep disturbance, and number of days of NPO for diagnostic examinations were analyzed. The results are as follows : 1. Of the 59 patients who were studied, 61% were male and 39% female. The nutritional status of all of the 59 subjects was reassessed one week after admission, but it was only done for 22 subjects at two weeks. 2. The anthropometric measurements. including weight body mass index, lean body mass, body fat. and skin fold thickness. were all significantly decreased at one week after admission compared to the values at admission. On the other hand, two weeks after admission, only body weight and abdominal skinfolds thickness were decreased. 3. The subjects reported anorexia for an average of two days, sleep disturbance for two days, and no food intake due to diagnostic test for one day. In the second week of hospitalization, almost none of the patients complained of gastrointestinal symptoms or sleep disturbance except anorexia. Food consumption which was measured based on rice intake was 60% of the food served during the first week of hospitalization, and 66% during the second week of hospitalization. 4. There was no correlation between the subjective nutritional assessment and anthropometric assessment. 5. There was no statistical significance in anthropometric measurements among the patients with various diseases whereas sleep disturbance and no food intake due to various diagnostic test was prominent in patients with gastrointestinal diseases.

  • PDF

Mandibular arch orthodontic treatment stability using passive self-ligating and conventional systems in adults: A randomized controlled trial

  • Rahman, Norma Ab;Wey, Mang Chek;Othman, Siti Adibah
    • The korean journal of orthodontics
    • /
    • v.47 no.1
    • /
    • pp.11-20
    • /
    • 2017
  • Objective: This randomized controlled trial aimed to compare the stability of mandibular arch orthodontic treatment outcomes between passive self-ligating and conventional systems during 6 months of retention. Methods: Forty-seven orthodontic patients with mild to moderate crowding malocclusions not requiring extraction were recruited based on inclusion criteria. Patients (mean age $21.58{\pm}2.94years$) were randomized into two groups to receive either passive self-ligating ($Damon^{(R)}$ 3MX, n = 23) or conventional system (Gemini MBT, n = 24) orthodontic treatment. Direct measurements of the final sample comprising 20 study models per group were performed using a digital caliper at the debonding stage, and 1 month, 3 months, and 6 months after debonding. Paired t-test, independent t-test, and non-parametric test were used for statistical analysis. Results: A significant increase (p < 0.01) in incisor irregularity was observed in both self-ligating and conventional system groups. A significant reduction (p < 0.01) in second interpremolar width was observed in both groups. Mandibular arch length decreased significantly (p = 0.001) in the conventional system group but not in the self-ligating system group. A similar pattern of stability was observed for intercanine width, first interpremolar width, intermolar width, and arch depth throughout the 6-month retention period after debonding. Comparison of incisor irregularity and arch dimension changes between self-ligating system and conventional system groups during the 6 months were non-significant. Conclusions: The stability of treatment outcomes for mild to moderate crowding malocclusions was similar between the self-ligating system and conventional system during the first 6 months of retention.

Localization of the Mental and Infraorbital Foramen with related to the Soft-tissue Landmarks

  • Lee, Yun-Ho;Lee, Myoung-Hwa;Yu, Sun-Kyoung;Jeong, Goo-Soo;Kim, Do-Kyung;Kim, Heung-Joong
    • International Journal of Oral Biology
    • /
    • v.37 no.1
    • /
    • pp.25-29
    • /
    • 2012
  • During maxillofacial surgery, the infraorbital and mental nerves are blocked at eac foramen to induce local anesthesia. This study examined the relative locations of the infraorbital foramen (IOF) and mental foramen (MF) based on softtissue landmarks. Twenty-eight hemifacial cadavers were dissected to expose the IOF and MF. The distances between the bilateral IOFs, the bilateral MFs, the alae of the nose (alares), and the corners of the mouth (cheilions) were measured directly on cadavers by using a digital vernier caliper. The vertical and horizontal distances of the IOF and MF relative to the alare and cheilion were measured indirectly on digital photographs using Adobe Photoshop (Adobe, CA, USA). The distance between the bilateral IOFs ($58.09{\pm}4.04mm$) was longer than the distance between the bilateral MFs ($50.32{\pm}1.93mm$). The distances between the bilateral alares and cheilions were $41.22{\pm}3.44mm$ and $58.43{\pm}6.62mm$, respectively. The IOF was located $12.92{\pm}3.75mm$ superior and $7.88{\pm}2.56mm$ lateral to the alare, and the vertical angle (Angle 1) between these structures was $31.67{\pm}13.36^{\circ}$ superolaterally. The MF was located $21.83{\pm}3.26mm$ inferior and $5.56{\pm}3.37mm$ medial to the cheilion, and the vertical angle (Angle 2) between these structures was $14.05{\pm}10.12^{\circ}$ inferomedially. In conclusion, these results provide more detailed information about the locations of the IOF and MF relative to soft-tissue landmarks.

Effect of digital noise reduction on the accuracy of endodontic file length determination

  • Mehdizadeh, Mojdeh;Khademi, Abbas Ali;Shokraneh, Ali;Farhadi, Nastaran
    • Imaging Science in Dentistry
    • /
    • v.43 no.3
    • /
    • pp.185-190
    • /
    • 2013
  • Purpose: The aim of the present study was to evaluate the measurement accuracy of endodontic file length on periapical digital radiography after application of noise reduction digital enhancement. Materials and Methods: Thirty-five human single-rooted permanent teeth with canals measuring 20-24 mm in length were selected. ISO #08 endodontic files were placed in the root canals of the teeth. The file lengths were measured with a digital caliper as the standard value. Standard periapical digital images were obtained using the Digora digital radiographic system and a dental X-ray unit. In order to produce the enhanced images, the noise reduction option was applied. Two blinded radiologists measured the file lengths on the original and enhanced images. The measurements were compared by repeated measures ANOVA and the Bonferroni test (${\alpha}=0.05$). Results: Both the original and enhanced digital images provided significantly longer measurements compared with the standard value (P<0.05). There were no significant differences between the measurement accuracy of the original and enhanced images (P>0.05). Conclusion: Noise reduction digital enhancement did not influence the measurement accuracy of the length of the thin endodontic files on the digital periapical radiographs despite the fact that noise reduction could result in the elimination of fine details of the images.

Effect of slice inclination and object position within the field of view on the measurement accuracy of potential implant sites on cone-beam computed tomography

  • Saberi, Bardia Vadiati;Khosravifard, Negar;Nourzadeh, Alireza
    • Imaging Science in Dentistry
    • /
    • v.50 no.1
    • /
    • pp.37-43
    • /
    • 2020
  • Purpose: The purpose of this study was to evaluate the accuracy of linear measurements in the horizontal and vertical dimensions based on object position and slice inclination in cone-beam computed tomography (CBCT) images. Materials and Methods: Ten dry sheep hemi-mandibles, each with 4 sites (incisor, canine, premolar, and molar), were evaluated when either centrally or peripherally positioned within the field of view (FOV) with the image slices subjected to either oblique or orthogonal inclinations. Four types of images were created of each region: central/cross-sectional, central/coronal, peripheral/cross-sectional, and peripheral/coronal. The horizontal and vertical dimensions were measured for each region of each image type. Direct measurements of each region were obtained using a digital caliper in both horizontal and vertical dimensions. CBCT and direct measurements were compared using the Bland-Altman plot method. P values <0.05 were considered to indicate statistical significance. Results: The buccolingual dimension of the incisor and premolar areas and the height of the incisor, canine, and molar areas showed statistically significant differences on the peripheral/coronal images compared to the direct measurements (P<0.05). Molar area height in the central/coronal slices also differed significantly from the direct measurements (P<0.05). Cross-sectional images of either the central or peripheral position had no marked difference from the gold-standard values, indicating sufficient accuracy. Conclusion: Peripheral object positioning within the FOV in combination with applying an orthogonal inclination to the slices resulted in significant inaccuracies in the horizontal and vertical measurements. The most undesirable effect was observed in the molar area and the vertical dimension.