• Title/Summary/Keyword: Caliper

Search Result 242, Processing Time 0.033 seconds

Surgically assisted rapid palatal expansion with tent screws and a custom-made palatal expander: a case report

  • Park, Kang-Nam;Lee, Chang Youn;Park, In Young;Kim, Jwa Young;Yang, Byoungeun
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.37
    • /
    • pp.11.1-11.5
    • /
    • 2015
  • Rapid palatal expansion(RPE) with the tooth-born appliance is not sufficient to apply to the patients with periodontal problem or insufficient tooth anchorage, and it leads to tipping of the anchorage teeth and increasing teeth mobility and root resorption. To avoid these disadvantages, we present the case using palatal screws and custommade palatal expander. A 23-year-old patient underwent surgically assisted rapid maxillary expansion with the Hyrax expansion using 4 tent screws. The study models were used to measure the pre-/-post surgical width of the anterior and posterior dental arches with a digital sliding caliper. In the result, the custom-made palatal expander with 4 tent screws is suitable for delivering a force to the mid-palatal suture expansion. And it is low cost, small sized and simply applied. The results indicated that maxillary expansion with the custom-made palatal anchorage device is predictable and stable technique without significant complications in patients.

A COMPARISON OF THE ACCESSORY CANAL FILLING EFFECTS OF THE THREE ROOT CANAL FILLING METHODS WITH GUTTA-PERCHA (Gutta-percha를 이용(利用)한 세가지 근관충전법(根管充塡法)의 부근관충전(副根管充塡) 효과비교(效果比較))

  • An, Seong-Ho;Cho, Kyew-Zeung
    • Restorative Dentistry and Endodontics
    • /
    • v.14 no.1
    • /
    • pp.121-133
    • /
    • 1989
  • In order to compare the accessory canal filling effects of the three root canal filling methods with gutta-percha, the author fabricated artificial root canal mold with the first and second accessory canals of chrome-cobalt alloy. After the artificial root canal was filled with gutta-percha by lateral condensation, vertical condensation and low-temperature thermoplasticized gutta-percha injection-molded method, twenty five times respectively, the gutta-percha forced into the first and second accessory canals were measured with caliper for length. The results were as follows: 1. The filling in both accessory canals was most effective in low-temperature thermoplasticized gutta-percha injection-melded method followed in such order as: vertical condensation method and lateral condensation method (p < 0.01). 2. The filling effect of the second accessory canal was more or less higher than that of the first one (p < 0.05). 3. Low-temperature thermoplasticized gutta-percha injection-molded method was fastest in time needed for root canal filling followed by lateral condensation method and vertical condensation method.

  • PDF

Improving the Precision of Specifications by Evaluating the Influence of Test Parameters on Tribological Results - A Synthesis from a Series of International - Round Robin Tests -

  • Woydt Mathias;Weber Hartwig
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 2003.11a
    • /
    • pp.164-180
    • /
    • 2003
  • A series of cooperative interlaboratory tests (round robins) was conducted in 1997, 1998, 1999, 2000, 2001, 2002 and 2003 by the DIN 51834 Working Group on Tribological Tests in Translatory Oscillation Apparatus. The statistical analysis of these test results shows the influence of cleaning solvent, machine model and evaluation criteria on the tribological properties of the lubricants tested. Coefficients of friction and wear results are ranked according to the effects of ten different cleaning solvents, where isopropanol gave the lowest values and isoparaffin solvents the highest. The effect of machine model on coefficients of friction varied from about $0.2\%\;to\;0.9\%$ of the mean. Wear results were not affected. The tests also showed that the seizure criteria and methods of measuring wear required for in the test procedure do not provide a suitable measure of the tribological properties of some lubricants. The precision was Improved by introducing a grease apply caliper as well as an increased stroke to 1,5 mm and running-in. The temperature does not affect the precision of the oil test procedure.

  • PDF

Residual bone height measured by panoramic radiography in older edentulous Korean patients

  • Liang, Xiang Hua;Kim, Young-Mi;Cho, In-Ho
    • The Journal of Advanced Prosthodontics
    • /
    • v.6 no.1
    • /
    • pp.53-59
    • /
    • 2014
  • PURPOSE. The aim of this study was to obtain statistical data on the residual bone height at different natural tooth positions by panoramic radiography in edentulous Korean patients aged 60-90 years. MATERIALS AND METHODS. The study included the diagnostic panoramic radiographs of 180 randomly selected edentulous patients without systemic diseases affecting bone. The radiographic selection criteria included absence of obvious facial asymmetry, clearly visible anatomic structures, and no surgical and fracture history. The panoramic radiographs of 79 patients met these criteria and were used in the analysis. The same researcher processed all the radiographs by using a standardized method. The height of the residual bone was measured at 18 predetermined sites (7 in the maxilla and 11 in the mandible) on digitized and printed radiographs by using a Digimatic caliper, triangle, and ruler. Gender- and age-related differences were statistically analyzed by using the t-test and rank-sum test (${\alpha}=0.05$). RESULTS. The maxillary residual bone height did not show significant gender-related differences, but male patients had significantly higher residual bone in the mandible(P<.05). No significant height differences at the measured sites were noted among the 60s, 70s, and 80s age groups. CONCLUSION. Dentists should pay greater attention to older female edentulous patients because they are more prone to rapid residual bone resorption. Residual bone resorption may not be affected by age.

Effect of Two Variables on the Casting Ability of Some Nonpercious Alloys for Porcelain-Metal Restorations (납형의 직경 및 소환방법이 도재-금속 보철물용 비귀금속 합금의 주조성에 미치는 영향)

  • Kim, Uoong-Chul
    • Journal of Technologic Dentistry
    • /
    • v.6 no.1
    • /
    • pp.19-26
    • /
    • 1984
  • This Experimental study was performed to study the effect of the heat soaking and the diameter of pattern on the casting ability of three nonprecious alloys manufactured for porcelain-metal restorations, with respect to their ability to reproduce test pieces by casting over a selected range of uniform diameters. Samples of total 60 were constructed and divided into 6 groups according to the two variables, the diameter and the heat soaking. The completed cast samples were examined visually and measured with a caliper calibrated to 0.05mm. The results obtained were as follows: 1. Length cast was significantly related to the diameter to be cast, especially in the case of the marrowest diameter of 230m. 2. Length cast not significantly related to the heat soaking. 3. The completeness of casting was significantly related to the diameter to be cast, particularly in the case of the narrowest diameter of 230m. 4. The completeness of casting was not significantly related to the heat soaking. 5. All of the three nonprecious alloys used for this experiment were significantly different from an ideal alloy in the completeness of casting.

  • PDF

Enhanced Approach Using Computational and Experimental Method for the Analysis of Loudspeaker System

  • Park Seok-Tae
    • The Journal of the Acoustical Society of Korea
    • /
    • v.24 no.3E
    • /
    • pp.90-98
    • /
    • 2005
  • Enhanced approach using computational and experimental method is proposed and performed to describe very well the behavior of loudspeaker than conventional method. Proposed procedure is composed of four parts. First, Thiele-Small parameters for test loudspeaker are identified by an electrical impedance method like as a delta mass method. Second part includes the processes to measure physical properties. Physical data like masses and thicknesses of loudspeaker's components are measured by an electrical precision scale and a digital vernier caliper. Third, the identified Thiele-Small parameters are proposed to be used as load boundary conditions for vibration analysis instead of electromagnetic circuit analysis to get a driving force upon bobbin part. Also, these parameters and physical data are used to modify physical properties required for computation to accommodate simulated sound pressure level with measured one for loudspeaker enclosure system. These data like as Young's modulus and thickness for a diaphragm are required for vibration analysis of loudspeaker but not measured accurately. Finally, it was investigated that simulated sound pressure level with full acoustic modeling including an acoustic port for test loudspeaker agreed with experimental result very well in the midrange frequency band(from 100 Hz to 2,000 Hz). In addition, several design parametric study is performed to grasp acoustical behaviors of loudspeaker system due to variations of diaphragm thicknesses and shapes of dust cap.

A Biometric Study on Hardness of Bone in Race Horse and Jeju Horse (경주마(競走馬)와 제주마(濟州馬)의 생리적(生理的) 골경도(骨硬度)에 관하여)

  • Lee, Won Chang;Kim, Hyo Jung;Shin, Tae Hong
    • Korean Journal of Veterinary Research
    • /
    • v.14 no.2
    • /
    • pp.185-189
    • /
    • 1974
  • Although considerable research has been done on the blood chemistry of domestic animals, little work has been made of the changes associated with age. Moreover, the records about physiology of the goat were not much available in Korea, and a comprehensive survey of the blood chemical values of the Korean native goat has not been made. The authors intended to biometric study on the hardness of bone of race horse and Jeju horse in Korea. The measurement of hardness of bone were performed in 272 race horses (Thoroughbred 91, Anglo-Arab 107, Arab 74) and in 109 Jeju horses by the caliper by Toryba's method. Some interesting facts obtained through this study were as follows: 1. There was not significant difference of bone hardness between male and female. The average of bone hardness by the Toryba's meteod were $23.07{\pm}1.01$ in race horse and $19.44{\pm}1.84$ in Jeju horse. 2. The grade of bone hardness of race horse were higher than those of Jeju horse(P<0.001). 3. The correlation coefficient between age and grade of bone hardness were r= +0.344 in Jeju horse, theme were statistically significant (P<0.01) and the regression equation was Y=0.29x+18.497.

  • PDF

A STUDY ON THE DEPTH OF POLYMERIZATION OF VISIBLE LIGHT ACTIVATED COMPOSITE RESINS (가시광선(可視光線)이 복합(複合)레진의 경화(硬化)에 미치는 효과(效果)에 관(關)한 연구(硏究))

  • Chung, Sae-Joon;Lee, Myung-Jong
    • Restorative Dentistry and Endodontics
    • /
    • v.10 no.1
    • /
    • pp.145-152
    • /
    • 1984
  • The purpose of this study was to compare combinations of the four visible light irradiating appliances (Translux, Heliomat, Pluraflex HL 150, Omega) and the four visible light activated composite resins (Durafil, Heliosit, Plurafil-super, Silux) to determine the depth of polymerization of each combination. Twenty samples were made with Durafil. Five samples were polymerized for 20 seconds using Translux, five with Heliomat, five with Pluraflex HL 150, five with Omega. Twenty samples were made with Heliosit, twenty with Plurafil-super, and twenty samples with Silux. A 20-second polymerization time was applied with each of 4 visible light irradiating appliances to 5 samples of each material. Eighty samples were treated in a like manner, but polymerization was extended to 40 seconds. Depth of polymerization were measured with caliper. The results were as follows. 1) Of the two time exposures, 40-second exposure provided a significantly greater depth of polymerization than 20-second for each light with each material. 2) Durafill-Translux system showed minimum depth of polymerization, and Plurafil-Pluraflex system showed maximum depth of polymerization. 3) Visible light irradiating appliances were able to harden the resins cured by tire visible lights of other makers' apparatuses. 4) In all circumstances, depth of polymerization was between 3.0-3.8mm.

  • PDF

ANTIMICROBIAL EFFECT OF ROOT CANAL CEMENTS ON MICROORGANISMS FROM INFECTED ROOT CANALS (수종 근관 충전재의 항균 효과에 관한 연구)

  • Koh, Young-Hoon;Choi, Ho-Young
    • Restorative Dentistry and Endodontics
    • /
    • v.16 no.1
    • /
    • pp.190-199
    • /
    • 1991
  • The purpose of this study was to evaluate the antimicrobial effect of root canal cements such as AH-26, Sealapex, Canals and Apatite root sealers(Type I, II, III) and to determine the efficacy of their activities. S.mutans(AHT), S.sanguis(NCTC 9811) and B.gingivalis(381) were streaked on blood agar and the PVC tybes filled with root canal cements were applied on. Then the microorganisms were cultured for 48 hours, anaerobically. B.cereus(KCTC 1012) was streaked on nutrient agar, PVC tubes were applied on and were cultured for 48 hours, aerobically. The inhibition zones of root canal cements were measured with vernier caliper. The data statistically analyzed, and the results were as followed. 1. Apatite root sealers(Type I, II, III) showed no inhibition zones. 2. AH-26, Sealapex and Canals had inhibition zones with varying degrees. The inhibition zone of AH-26 was greatest and followed by Canals and Sealapex(P<0.01). 3. As time goes by after mixing the root canal cements, AH-26, Canals and Sealapex showed significantly reducing inhibition zones(P<0.01). 4. There were the least inhibition zones of all the root canal cements on S.mutans and followed in such order as; B.gingivalis, S.sanguis and B.cereus(P<0.01).

  • PDF

Prediction of Suitable Site to Measure Abdominal Skin Fold Thickness and Correlation among Obesity Indicators in Patients with Type 2 Diabetes Mellitus (제2형 당뇨병 환자에서 피부두겹두께의 측정부위 예측 및 비만지표들 간의 관련성)

  • Hwang, Moon Sook
    • Journal of Korean Biological Nursing Science
    • /
    • v.22 no.1
    • /
    • pp.36-44
    • /
    • 2020
  • Purpose: The purpose of this study was to predict measuring site suited for abdominal skin fold thickness (ASFT) by measuring the distribution of abdominal subcutaneous fat thickness (AScFT) and ascertain the correlations among obesity indicators. Methods: The size of analysis materials was 124 secondary data measured by ultrasonic device, bioelectrical impedance analyzer and caliper. Data were analyzed using t-test, and Pearson's correlation. Results: The average of AScFT was 10.63± 6.79mm with its range 1.39-36.16 mm, and AScFT of female and of central parts were thicker than those of male and outer parts in the abdomen. The average of ASFT was 29.26±12.59 mm. Site 5 on Figure 1 was most similar to the average of AScFT in both sexes. Body mass index (BMI) and waist hip ratio (WHR) were 23.65±3.98 and 0.88±0.05 respectively. The body weight, BMI, WHR, visceral fat, ASFT vs AScFT revealed in significant correlation (r= .29, r= .55, r= .39, r= .33. r= .29). Conclusion: BMI and WHR seem more useful than other obesity indicators, when obesity control is necessary for Type 2 diabetes patients. Site 5 on Figure 1 is most suitable site to measure ASFT.