• Title/Summary/Keyword: Calibration matrix

Search Result 255, Processing Time 0.024 seconds

Hard calibration of a structured light for the Euclidian reconstruction (3차원 복원을 위한 구조적 조명 보정방법)

  • 신동조;양성우;김재희
    • Proceedings of the IEEK Conference
    • /
    • 2003.11a
    • /
    • pp.183-186
    • /
    • 2003
  • A vision sensor should be calibrated prior to infer a Euclidian shape reconstruction. A point to point calibration. also referred to as a hard calibration, estimates calibration parameters by means of a set of 3D to 2D point pairs. We proposed a new method for determining a set of 3D to 2D pairs for the structured light hard calibration. It is simply determined based on epipolar geometry between camera image plane and projector plane, and a projector calibrating grid pattern. The projector calibration is divided two stages; world 3D data acquisition Stage and corresponding 2D data acquisition stage. After 3D data points are derived using cross ratio, corresponding 2D point in the projector plane can be determined by the fundamental matrix and horizontal grid ID of a projector calibrating pattern. Euclidian reconstruction can be achieved by linear triangulation. and experimental results from simulation are presented.

  • PDF

Verification of a Calibration Technique for a Full-Polarimetric Scatterometer System at C-band (C-밴드 완전 편파 측정용 스캐터미터 시스템 보정 기술 검증)

  • Park, Sin-Myeong;Go, Joo-Seoc;Joo, Jeong-Myeong;Kim, Hee-Young;Kim, Ju-Hui;Hwang, Ji-Hwan;Kwon, Soon-Gu;Shin, Jong-Chul;Oh, Yisok
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.23 no.10
    • /
    • pp.1196-1203
    • /
    • 2012
  • This paper presents a study on the calibration of a C-band HPS(Hongik Polarimetric Scatterometer) system using the DMMCT(Differential Mueller Matrix Calibration Technique). For calibration of the polarimetric scatterometer system, a fully-polarimetric antenna pattern(magnitudes and phase-differences) of the antenna main-beam is measured using a conducting sphere at anechoic chamber. The polarimetric scatterometer system could be accurately calibrated after retrieving its distortions using the DMMCT. Unlike a single-polarimetric system, in a fully-polarimetric system, not only backscattering coefficients but also phase differences are important parameters. This calibrated HPS system can be used to measure accurate Mueller matrices of bare soil surfaces, rice paddies, and vegetation fields. The phase-difference parameters as well as the backscattering coefficients for co- and cross-polarizations can then be obtained. The accuracy of calibration was verified by comparing the measured backscattering coefficients with a scattering model. The measured polarization response of a plowed bare field was also compared with the polarization response which was synthesized using a polarimetric scattering model for verifying the calibration technique.

Efficiency calibration of a coaxial HPGe detector-Marinelli beaker geometry using an 152Eu source prepared in epoxy matrix and its validation by efficiency transfer method

  • Yucel, Haluk;Zumrut, Senem;Nartturk, Recep Bora;Gedik, Gizem
    • Nuclear Engineering and Technology
    • /
    • v.51 no.2
    • /
    • pp.526-532
    • /
    • 2019
  • In this study, an in-house $^{152}Eu$ calibration source was produced from a custom epoxy matrix with a density of ${\rho}=1.14g\;cm^{-3}$, which is chemically stable and durable form after its solidification. The homogeneity of $^{152}Eu$ in matrix was obtained better than 98%. For a Marinelli beaker geometry, an efficiency calibration procedure was applied to a n-type, coaxial, 78.5% relative efficient HPGe detector in the energy range of 121.7-1408.0 keV by using in-house $^{152}Eu$ calibration source. Then the measured efficiencies for Marinelli geometry were compared with the results calculated by MEFFTRAN and ANGLE softwares for the validation. Although MEFFTRAN and ANGLE have two different efficiency transfer algorithms to calculate the efficiencies, they usually need to use a reliable and accurate reference efficiency values as input data. Hence, reference efficiency values were obtained experimentally from a multinuclide standard source for the same detector-Marinelli geometry. In the present source characterization, the corrections required for self-absorption and true coincidence summing effects for $^{152}Eu$ gamma-rays were also obtained for a such close counting geometry condition. The experimental results confirmed the validity of efficiency calculations obtained by MEFFTRAN and ANGLE softwares that are calculation tools.

The Selection of Sample Injection Modes and Its Effect on the Calibration Bias in S Gas Detection by Gas Chromatography (GC의 주입방식 차에 따른 고농도 악취황 성분의 검량오차 연구 : 주입부피의 고정방식 대비 주입농도의 고정방식 간 비교연구)

  • Kim Ki-Hyun;Choi YJ
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.21 no.2
    • /
    • pp.269-274
    • /
    • 2005
  • In this work, analytical bias arising from the gas chromatographic determination of sulfur compounds was evaluated by the application of direct loop injection method to the GC/PFPD detection of four sulfur compounds including H$_{2}$S, CH$_{3}$SH, DMS, and DMDS. For the proper evaluation of analytical uncertainties involved in GC calibration, we employed two comparative techniques of calibration at fxed concentration injection (CFCI) vs calibration at fixed volume injection (CFVI) method. The results of our study indicate that CFCI method exhibits very poor sensitivity due to the matrix effect with varying injection volumes. On the other hand, as CFVI method overcomes such limitation, it can be used to obtain very accurate quantification of S compounds at their high concentration levels above a few to a few tens ppb.

A New Linear Explicit Camera Calibration Method (새로운 선형의 외형적 카메라 보정 기법)

  • Do, Yongtae
    • Journal of Sensor Science and Technology
    • /
    • v.23 no.1
    • /
    • pp.66-71
    • /
    • 2014
  • Vision is the most important sensing capability for both men and sensory smart machines, such as intelligent robots. Sensed real 3D world and its 2D camera image can be related mathematically by a process called camera calibration. In this paper, we present a novel linear solution of camera calibration. Unlike most existing linear calibration methods, the proposed technique of this paper can identify camera parameters explicitly. Through the step-by-step procedure of the proposed method, the real physical elements of the perspective projection transformation matrix between 3D points and the corresponding 2D image points can be identified. This explicit solution will be useful for many practical 3D sensing applications including robotics. We verified the proposed method by using various cameras of different conditions.

Precise Detection of Coplanar Checkerboard Corner Points for Stereo Camera Calibration Using a Single Frame (스테레오 카메라 캘리브레이션을 위한 동일평면 체커보드 코너점 정밀검출)

  • Park, Jeong-Min;Lee, Jong-In;Cho, Joon-Bum;Lee, Joon-Woong
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.21 no.7
    • /
    • pp.602-608
    • /
    • 2015
  • This paper proposes an algorithm for precise detection of corner points on a coplanar checkerboard in order to perform stereo camera calibration using a single frame. Considering the conditions of automobile production lines where a stereo camera is attached to the windshield of a vehicle, this research focuses on a coplanar calibration methodology. To obtain the accurate values of the stereo camera parameters using the calibration methodology, precise localization of a large number of feature points on a calibration target image should be ensured. To realize this demand, the idea with respect to a checkerboard pattern design and the use of a Homography matrix are provided. The calibration result obtained by the proposed method is also verified by comparing the depth information from stereo matching and a laser scanner.

Analysis of Residual Organic Solvent in Environmentally-friendly Farming Materials with Headspace Method (Headspace 법을 사용한 유기농업자재 중 잔류 유기용매 분석)

  • Choi, Geun Hyoung;Kong, Seung-Heon;Park, Byung-Jun;Moon, Byeong-Cheol;Kim, Jin-Hyo
    • The Korean Journal of Pesticide Science
    • /
    • v.20 no.2
    • /
    • pp.128-132
    • /
    • 2016
  • Volatile organic solvents are used to extract the bioactive materials from raw materials for environmentally-friendly farming materials (EFFM), but the solvent should not remain in EFFM for the safety reasons. Thus qualitative and quantitative analysis method for the solvents using Headspace-GC were evaluated. Water content depleted the detection ratio of hydrophilic solvents and disturbing the hydrophilic interaction with solvents by DMSO might be helped to increase the detection ratio (up to 715%). Surfactant concentration affected to the detection ratio (68.5-179.1%) while surfactant type was not deeply involved the solvent detection. On the other hand, matrix-matched calibration method was accepted the minimum requirements for the quantitative analysis of the solvents in EFFM.

A Study on Influential Subset Detection in Regression

  • Kim, Seung Gu;Yum, Joon Keun
    • Journal of Korean Society for Quality Management
    • /
    • v.17 no.1
    • /
    • pp.107-115
    • /
    • 1989
  • This study is suggested tn find a methodology of influential subset detecting by using diagonal elements of the hat matrix, $h_{ij}$, and off-diagonal elements of the modified hat matrix, $h_{ij^*}$. And this study shows that elements of two matrix is very useful to detect a masking subset in various situations by analytic and emperical explanations. Also a desirable procedure to detect the significant subset and the calibration points for $h_{ij}$ and $h_{ij^*}$ are recommended.

  • PDF

Fundamental Matrix Estimation and Key Frame Selection for Full 3D Reconstruction Under Circular Motion (회전 영상에서 기본 행렬 추정 및 키 프레임 선택을 이용한 전방향 3차원 영상 재구성)

  • Kim, Sang-Hoon;Seo, Yung-Ho;Kim, Tae-Eun;Choi, Jong-Soo
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.46 no.2
    • /
    • pp.10-23
    • /
    • 2009
  • The fundamental matrix and key frame selection are one of the most important techniques to recover full 3D reconstruction of objects from turntable sequences. This paper proposes a new algorithm that estimates a robust fundamental matrix for camera calibration from uncalibrated images taken under turn-table motion. Single axis turntable motion can be described in terms of its fixed entities. This provides new algorithms for computing the fundamental matrix. From the projective properties of the conics and fundamental matrix the Euclidean 3D coordinates of a point are obtained from geometric locus of the image points trajectories. Experimental results on real and virtual image sequences demonstrate good object reconstructions.

Characteristic Responses of Biosensor Based on $H^+$-Selective Membrance Electrode (H$^+$ 선택성 막 전극을 이용한 바이오센서의 감응 특성)

  • Kim, Ki-Myo;Park, Sung-Bae;Hwang, Myoung-Seok;Hur, Moon-Hye;Ahn, Moon-Kyu
    • YAKHAK HOEJI
    • /
    • v.40 no.6
    • /
    • pp.625-631
    • /
    • 1996
  • The $H^+$-selective membrane consists of tridodecylamine, 2-nitrophenyl octyl ether and a little amount of additive in carboxylated PVC matrix, where penicillinase(Pcase ) and glutaraldehyde may be covalently attached to the matrix. When the $H^+$-selective electrode was used as a detector of biosensor, calibration curve calculated from Nernst equation was not linear. So we investigated the characteristic responses of the $H^+$-selective electrode to the product H+ from hydrolysis of penicillin-G(Pc-G) and plotted calibration curve correlating potential to concentration of Pc-G linearly. The optimal concentration of buffer solution was theoretically calculated and was also experimented. We tried to explain the linear curve of potential to concentration of Pc-G by using Henderson-Hasselbach equation. This method is more effective in calibration curve plotting than any other previous methods. The results obtained may help in further developing pH electrodes with improved analytical preformance.

  • PDF