Site Calibration for the Wind Turbine Performance Evaluation

  • Nam, Yoon-Su;Yoo, Neung-Soo;Lee, Jung-Wan
    • Journal of Mechanical Science and Technology
    • /
    • v.18 no.12
    • /
    • pp.2250-2257
    • /
    • 2004
  • The accurate wind speed information at the hub height of a wind turbine is very essential to the exact estimation of the wind turbine power performance testing. Several methods on the site calibration, which is a technique to estimate the wind speed at the wind turbine's hub height based on the measured wind data using a reference meteorological mast, are introduced. A site calibration result and the wind resource assessment for the TaeKwanRyung test site are presented using three-month wind data from a reference meteorological mast and the other mast temporarily installed at the site of wind turbine. Besides, an analysis on the uncertainty allocation for the wind speed correction using site calibration is performed.

Learning the nonlinearity of a camera calibration model using GMDH algorithm (GMDH 알고리즘에 의한 카메라 보정 모델의 비선형성 학습)

  • Kim, Myoung-Hwan;Do, Yong-Tae
    • Journal of Sensor Science and Technology
    • /
    • v.14 no.2
    • /
    • pp.109-115
    • /
    • 2005
  • Calibration is a prerequisite procedure for employing a camera as a 3D sensor in an automated machines like robots. As accurate sensing is possible only when the vision sensor is calibrated accurately, many different approaches and models have been proposed for increasing calibration accuracy. Particularly an important factor which greatly affects the calibration accuracy is the nonlinearity in the mapping between 3D world and corresponding 2D image. In this paper GMDH algorithm is used to learn the nonlinearity without physical modelling. The technique proposed can be effective in various situations where the levels of noises and characteristics of nonlinear distortion are different. In simulations and an experiment, the proposed technique showed good and reliable results.

Calibration of CR-39 for Measurement of Radon in Air (공기중의 라돈 농도 측정을 위한 CR-39의 교정)

  • Park, Y.W.;Chang, S.Y.;Ha, C.W.;Ro, S.G.
    • Journal of Radiation Protection and Research
    • /
    • v.14 no.2
    • /
    • pp.18-22
    • /
    • 1989
  • In order to calibrate the CR-39 Solid State Nuclear Track Detector (SSNTD), a closed -circulation type SSNTD-Calibration-System containing a radon-cup with the Millipore filter has been set-up, and the tracks produced on the SSNTD were measured for the known amount of radon concentration. Calibration factor for the time integrated radon concentration as a function of the track density on CR-39 was estimated to be $0.24{\pm}0.09(pCi/l)\;day/(Tr/cm^2)$.

  • PDF

Calibration of Health Monitoring System installed in the Railway Bridges (철도교 상시계측시스템의 교정 및 교정상수 설정에 관한 연구)

  • 박준오;이준석;최일윤;민경주
    • Journal of the Korean Society for Railway
    • /
    • v.5 no.3
    • /
    • pp.148-157
    • /
    • 2002
  • A health monitoring system becomes a useful tool to obtain information on long term behavior of the important railway structures such as very long span and special type bridges. The health monitoring system not only gives the direct measurement data of the railway bridges but also provides the basic data on the maintenance of the structures. Therefore, periodic calibrations of the health monitoring system will be a necessary step toward precise and accurate assessment of the railway bridges. In this study, the calibration and gauge factor readjustment process made for the health monitoring system installed in the railroad bridges is reviewed and some findings are explained in detail: specifically, the calibrators made for this purpose are illustrated and the regression processes of the calibration on long-term displacement using water level sensor, longitudinal displacement using LVDT sensor, instantaneous displacement using LVDT sensors and accelerometer are described in full length. Based on the regression results, it was found that the gauge factors need to be readjusted according to the regression equation but, since the deviation or shift is not serious so far, long-term observation on each sensor is also recommended. Future work will be concentrated on the long-term analysis of each sensor and on the database creation so that the assessment of the structures is possible.

Automatic Calibration of SWAT Model Using LH-OAT Sensitivity Analysis and SCE-UA Optimization Method (LH-OAT 민감도 분석과 SCE-UA 최적화 방법을 이용한 SWAT 모형의 자동보정)

  • Lee Do-Hun
    • Journal of Korea Water Resources Association
    • /
    • v.39 no.8 s.169
    • /
    • pp.677-690
    • /
    • 2006
  • The LH-OAT (Latin Hypercube One factor At a Time) method for sensitivity analysis and SCE-UA (Shuffled Complex Evolution at University of Arizona) optimization method were applied for the automatic calibration of SWAT model in Bocheong-cheon watershed. The LH-OAT method which combines the advantages of global and local sensitivity analysis effectively identified the sensitivity ranking for the parameters of SWAT model over feasible parameter space. Use of this information allows us to select the calibrated parameters for the automatic calibration process. The performance of the automatic calibration of SWAT model using SCE-UA method depends on the length of calibration period, the number of calibrated parameters, and the selection of statistical error criteria. The performance of SWAT model in terms of RMSE (Root Mean Square Error), NSEF (Nash-Sutcliffe Model Efficiency), RMAE (Relative Mean Absolute Error), and NMSE (Normalized Mean Square Error) becomes better as the calibration period and the number of parameters defined in the automatic calibration process increase. However, NAE (Normalized Average Error) and SDR (Standard Deviation Ratio) were not improved although the calibration period and the number of calibrated parameters are increased. The result suggests that there are complex interactions among the calibration data, the calibrated parameters, and the model error criteria and a need for further study to understand these complex interactions at various representative watersheds.

An Empirical Test for CVM Calibration Factor through Combining Revealed and Stated Preferences Data (현시선호와 진술선호 자료의 결합을 통한 조건부 가치측정법 소득조정계수의 추정)

  • Eom, Young Sook;Larson, Douglas M.
    • Environmental and Resource Economics Review
    • /
    • v.13 no.3
    • /
    • pp.337-366
    • /
    • 2004
  • Contingent Valuation Method (CVM), as non-market valuation approach, has been criticized on that respondents may not realistically reflect their budget constraints in answering willingness to pay (WTP) for hypothetical CV questions. This paper empirically estimates the income calibration factor associated with CV responses through combining travel cost method and contingent valuation method in a utility-theoretic framework. The joint model of recreation demand function and contingent WTP function was applied to an important case study on the Man Kyoung River system, whose water quality is at issue because of the Sae Alan Kum reclamation project. Relevant economic variables such as price, income and water quality had significant influence as anticipated by the economic theory. Equally important, the income calibration factor was not significantly different from one, suggesting that the systematic discrepancies of CV responses relative to the actual behavior was not detected at least in terms of budget exaggeration. Overall, this study supports the notion that carefully designed CVM studies can provide informative data on individuals' willingness to pay for environmental quality changes.

  • PDF

Practical Output Dosimetry with Undefined $N_{dw}{^{Co-60}}$ of Cylindrical Ionization Chamber for High Energy Photon Beams of Linear Accelerator ($N_{dw}{^{Co-60}}$이 정의되지 않은 원통형 이온전리함을 이용한 고에너지 광자선의 임상적 출력선량 결정)

  • Oh, Young-Kee;Choi, Tae-Jin;Song, Ju-Young
    • Progress in Medical Physics
    • /
    • v.23 no.2
    • /
    • pp.114-122
    • /
    • 2012
  • For the determination of absorbed dose to water from a linear accelerator photon beams, it needs a exposure calibration factor $N_x$ or air kerma calibration factor $N_k$ of air ionization chamber. We used the exposure calibration factor $N_x$ to find the absorbed dose calibration factors of water in a reference source through the TG-21 and TRS-277 protocol. TG-21 used for determine the absorbed dose in accuracy, but it required complex calculations including the chamber dependent factors. The authors obtained the absorbed dose calibration factor $N_{dw}{^{Co-60}}$ for reduce the complex calculations with unknown $N_{dw}$ only with $N_x$ or $N_k$ calibration factor in a TM31010 (S/N 1055, 1057) ionization chambers. The results showed the uncertainty of calculated $N_{dw}$ of IC-15 which was known the $N_x$ and $N_{dw}$ is within -0.6% in TG-21, but 1.0% in TRS-277. and TM31010 was compared the $N_{dw}$ of SSDL to that of PSDL as shown the 0.4%, -2.8% uncertainty, respectively. The authors experimented with good agreement the calculated $N_{dw}$ is reliable for cross check the discrepancy of the calibration factor with unknown that of TM31010 and IC-15 chamber.

Design of Simple Direct Comparison Measurement System from 10 MHz to 1 GHz for Thermistor Mounts Calibration (서미스터 마운트 교정을 위한 10 MHz에서 1 GHz 주파수 대역의 단순 직접 비교 측정시스템 설계)

  • Cha, Yun-Bae;Jang, Young-Guen;Kim, Boo-Il
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.15 no.3
    • /
    • pp.405-412
    • /
    • 2020
  • The thermistor mount is used for precise RF power measurement because the calibration factor is constant according to the change of power. The calibration factor of the standard mount can be measured with an uncertainty less than 0.5 % from the 10 MHz to 1 GHz by direct comparison with the transfer standard using the DC substitution method. Recently, as the supply of precision power meter based on DC substitution method allows simple and fast measurement, a simple direct comparison measurement system with the same level uncertainty was designed and the minimum required specifications of components through analysis of mismatch error was proposed. The uncertainty was evaluated for system validation, and the results show that uncertainties have been well maintained within 0.5 % in the measurement frequencies.

Calibration of Thermistors for Precision Temperature Measurements (정밀온도측정을 위한 서미스터 교정)

  • Gam, Kee-Sool;Kim, Yong-Gyoo;Yang, In-Seok
    • Journal of Sensor Science and Technology
    • /
    • v.20 no.5
    • /
    • pp.329-335
    • /
    • 2011
  • We demonstrated that high-stability thermistors can be calibrated with an uncertainty less than 1 mK, if the error due to the heat conduction is minimized. We first investigated the effect of the self-heating of typical thermistor probes to see how accurate we need to determine the effect of self-heating. We, then, calibrated thermistors and fitted the results using various modeling equations. We found out that the heat conduction is an important factor in achieving the calibration uncertainty under 1 mK for thermistors when the diameter of the probe is as thick as 10 mm. Therefore, we controlled the room temperature within $0.5^{\circ}C$ to minimize the heat conduction error during the calibration. The calibration with an uncertainty below 1 mK was possible when the stabilization time for each calibration was long enough to obtain a good thermal equilibrium.

A parameter calibration method for PFC simulation: Development and a case study of limestone

  • Xu, Z.H.;Wang, W.Y.;Lin, P.;Xiong, Y.;Liu, Z.Y.;He, S.J.
    • Geomechanics and Engineering
    • /
    • v.22 no.1
    • /
    • pp.97-108
    • /
    • 2020
  • The time-consuming and less objectivity are the main problems of conventional micromechanical parameters calibration method of Particle Flow Code simulations. Thus this study aims to address these two limitation of the conventional "trial-and-error" method. A new calibration method for the linear parallel bond model (CM-LPBM) is proposed. First, numerical simulations are conducted based on the results of the uniaxial compression tests on limestone. The macroscopic response of the numerical model agrees well with the results of the uniaxial compression tests. To reduce the number of the independent micromechanical parameters, numerical simulations are then carried out. Based on the results of the orthogonal experiments and the multi-factor variance analysis, main micromechanical parameters affecting the macro parameters of rocks are proposed. The macro-micro parameter functions are ultimately established using multiple linear regression, and the iteration correction formulas of the micromechanical parameters are obtained. To further verify the validity of the proposed method, a case study is carried out. The error between the macro mechanical response and the numerical results is less than 5%. Hence the calibration method, i.e., the CM-LPBM, is reliable for obtaining the micromechanical parameters quickly and accurately, providing reference for the calibration of micromechanical parameters.