• 제목/요약/키워드: Calibration chamber system

검색결과 78건 처리시간 0.027초

Quantitative Vapor Phase Exciplex Fluorescence Measurements at High Ambient Temperature and Pressure

  • Kim, Tongwoo;Jaal B. Ghandhi
    • Journal of Mechanical Science and Technology
    • /
    • 제17권1호
    • /
    • pp.157-167
    • /
    • 2003
  • The exciplex fluorescence technique with the TMPD (tetamethyl-Ρ-phenylene-diamine) / naphthalene dopant system was applied in a combustion-type constant-volume spray chamber. A detailed set of calibration experiments has been performed in order to quantify the TMPD fluorescence signal. It has been demonstrated that the TMPD fluorescence intensity was directly proportional to concentration, was independent of the chamber pressure, and was not sensitive to quenching by either water vapor or carbon dioxide. Using a dual heated-jet experiment, the temperature dependence of TMPD fluorescence up to 1000 K was measured. The temperature field in the spray images was determined using a simple mixing model, and an iterative solution method was used to determine the concentration and temperature field including the additional effects of the laser sheet extinction. The integrated fuel vapor concentration compared favorably with the measured amount of injected fuel when all of the liquid fuel had evaporated.

가스 센서모듈 및 센서보정시스템 개발 (Development of Gas Sensor Modules and Sensor Calibration Systems)

  • 박철영;임병훈;류정탁
    • 한국산업정보학회논문지
    • /
    • 제15권2호
    • /
    • pp.83-90
    • /
    • 2010
  • 센서는 센서네트워크와 같은 다양한 센서시스템에 응용되고 있는 핵심부품이다. 그러나 센서는 온도에 따른 출력특성과 비선형성을 가지기 때문에 개발이 쉽지 않다. 이러한 문제점을 해결하기 위해서는 센서의 보정과정이 필요 하지만 현재의 센서보정과정에서는 많은 보정시간과 비용을 요구하고 있다. 그러므로 보정시간과 비용을 최소화할 수 있는 보정시스템개발이 필요하다. 본 논문에서 CO 및 $CO_2$ 센서모듈 개발과 현재의 보정방법에서의 문제점들을 해결할 수 있는 다수센서보정시스템을 제안한다. 제안하는 시스템은 센서모듈, 시스템보드 및 모니터링프로그램 등으로 구성되며 보정은 최소자승법을 기반 한 회귀분석 방법을 사용한다. 제안한 보정시스템의 구성 및 실험결과에 대해 소개하고 결과를 바탕으로 시스템의 유효성을 검증한다.

표준 감마선 전리함 장치에 의한 방사능 비교 측정 (Comparative Measurement of Radioactivity with Standard Gamma-ray Ionization Chamber System)

  • 박태순;우동호;오필제;황선태
    • Journal of Radiation Protection and Research
    • /
    • 제9권1호
    • /
    • pp.11-18
    • /
    • 1984
  • Well type 전리함과 미세전류 측정희로를 사용하여 표준 감마선 전리함 장치를 개발하였다. 미세전류는 automatic Townsend balance with stepwise compensation방법을 사용하여 측정하였다. $^{226}Ra$을 기준 선원으로 택하여 감마 방출핵종인 $^{241}Am,\;^{133}Ba,\;^{60}Co,\;^{134}Cs,\;^{137}Cs^{22}Na$에 대한 비교 교정인자를 산출하였으며, 감마에너지의 함수로서 검출 효율 곡선을 구하였다.

  • PDF

An Iterative MUSIC-Based DOA Estimation System Using Antenna Direction Control for GNSS Interference

  • Seo, Seungwoo;Park, Youngbum;Song, Kiwon
    • Journal of Positioning, Navigation, and Timing
    • /
    • 제9권4호
    • /
    • pp.367-378
    • /
    • 2020
  • This paper introduces the development of the iterative multiple signal classification (MUSIC)-based direction-of-arrival (DOA) estimation system using a rotator that can control the direction of antenna for the global navigation satellite system (GNSS) interference. The system calculates the spatial spectrum according to the noise eigenvector of all dimensions to measure the number of signals (NOS). Also, to detect the false peak, the system adjusts the array antenna's direction and checks the change's peak angles. The phase delay and gain correction values for system calibration are calculated in consideration of the chamber's structure and the characteristics of radio waves. The developed system estimated DOAs of interferences located about 1km away. The field test results show that the developed system can estimate the DOA without NOS information and detect the false peak even though the inter-element spacing is longer than the half-wavelength of the interference.

대형 Calibration Chamber System을 이용한 ${{\sigma}_v}'-D_r-N$ 상관관계 연구 (A Study of ${{\sigma}_v}'-D_r-N$ Correlation using Large Calibration Chamber System)

  • 최성근;김상인;이충호;김동후;이우진
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2005년도 춘계 학술발표회 논문집
    • /
    • pp.1175-1182
    • /
    • 2005
  • Using KUCCS, which enables real-time monitoring and controlling, the various boundary condition and in-situ field stress condition was simulated, to derive the correlation among ${{\sigma}_v}'-Dr-N$in domestic sandy soils. Soil specimens, having various relative density and confined stress, were formulated to evaluate N-value from the SPT. and Pile Driving Analyzer, PDA, was employed as a measuring device for the energy transfer efficiency in the rod. From the quantitative analysis of N-value, the correlating equation, $N_{60}/{D_r}^2=16.35+14.45{{\sigma}_v}'$ was obtained on the basis of Skempton's method(1986). More reliable soil parameters can be obtained from the N-value by using this study which considered regional characters and the correlation among ${{\sigma}_v}'-Dr-N$.

  • PDF

고선량 Ir-192선원 교정기의 제작 및 특성 (High Dose Rate Ir-192 Source Calibration Method with Newly Designed Calibration Jig)

  • 이병용;최은경;장혜숙
    • Radiation Oncology Journal
    • /
    • 제7권2호
    • /
    • pp.299-303
    • /
    • 1989
  • Authors have developed highly reproducible calibration method for the Micro-Selectron HDR Ir-192 system (Nucletron, Motherland). The new jig has a 10cm radius circular hole in the $30cm{\times}30cm{\times}0.2cm$ acrylic plate, and 5F flexible bronchial tubes are attached around the hole. The source moves along the circle in the tubes and the ionization chamber is placed verticaly at the center of the circular hole (center of the jig). Dose distribution near the center was derived theoretically, and measured with the film dosimetry system. Theoretical calculation and measurement show the error margin below $0.1\%$ for 1mm or 2mm position deviation. We have measured at 12 and 24 points of circle with 1, 6, 11 and 21 second dwell time of source in order to calculate the activity of the source. Measurements have been repeated daily for 50 days. The accuracy and the reproducibility are below $1\%$ error margin. The half life of the source from our measurement is estimated $73.4\pm0.4$ days.

  • PDF

벼논에서 폐쇄형 자동 챔버 시스템으로 측정한 메탄 농도에 대한 요인별 측정 불확도 비교 (Measurement Uncertainty of Methane Concentrations from a Rice Paddy Measured by a Closed Automated Chamber System)

  • 주옥정;강남구;임갑준
    • 한국환경농학회지
    • /
    • 제39권3호
    • /
    • pp.228-236
    • /
    • 2020
  • BACKGROUND: The closed chamber method is the most commonly used for measuring greenhouse gas emissions from rice fields. This method has the advantages of being simple, easily available and economical. However, a measurement result using the chamber method is an estimated value and is complete when the uncertainty is estimated. The methane emissions from a rice paddy account for the largest portion of the greenhouse gas emissions in the agriculture sectors. Although assessment of uncertainty components affecting methane emission from a rice paddy is necessary to take account of dispersion characteristics, research on these uncertainty components is very rare to date. The goal of this study was to elucidate influencing factors on measurement uncertainty of methane concentrations measured by a closed automated chamber system from a rice paddy. METHODS AND RESULTS: The methane sampling system is located in the rice paddy in Gyeonggi-do Agricultural Research and Extension Services (37°13'15"N, 127°02'22"E). The primary measurement uncertainty components influencing methane concentrations (influencing factors) investigated in this research were repeatability, reproducibility and calibration in the aspects of methane sampling and analytical instrumentation. The magnitudes of the relative standard uncertainty of each influencing factor were quantified and compared. CONCLUSION: Results of this study showed what influencing factors were more important in determination of methane concentrations measured using the chamber system and analytical instrumentation located in the monitoring site. Quantifying the measurement uncertainty of the methane concentrations in this study would contribute to improving measurement quality of methane fluxes.

Uncertainty Assessment: Relative versus Absolute Point Dose Measurement for Patient Specific Quality Assurance in EBRT

  • Mahmood, Talat;Ibrahim, Mounir;Aqeel, Muhammad
    • 한국의학물리학회지:의학물리
    • /
    • 제28권3호
    • /
    • pp.111-121
    • /
    • 2017
  • Verification of dose distribution is an essential part of ensuring the treatment planning system's (TPS) calculated dose will achieve the desired outcome in radiation therapy. Each measurement have uncertainty associated with it. It is desirable to reduce the measurement uncertainty. A best approach is to reduce the uncertainty associated with each step of the process to keep the total uncertainty under acceptable limits. Point dose patient specific quality assurance (QA) is recommended by American Association of Medical Physicists (AAPM) and European Society for Radiotherapy and Oncology (ESTRO) for all the complex radiation therapy treatment techniques. Relative and absolute point dose measurement methods are used to verify the TPS computed dose. Relative and absolute point dose measurement techniques have a number of steps to measure the point dose which includes chamber cross calibration, electrometer reading, chamber calibration coefficient, beam quality correction factor, reference conditions, influences quantities, machine stability, nominal calibration factor (for relative method) and absolute dose calibration of machine. Keeping these parameters in mind, the estimated relative percentage uncertainty associated with the absolute point dose measurement is 2.1% (k=1). On the other hand, the relative percentage uncertainty associated with the relative point dose verification method is estimated to 1.0% (k=1). To compare both point dose measurement methods, 13 head and neck (H&N) IMRT patients were selected. A point dose for each patient was measured with both methods. The average percentage difference between TPS computed dose and measured absolute relative point dose was 1.4% and 1% respectively. The results of this comparative study show that while choosing the relative or absolute point dose measurement technique, both techniques can produce similar results for H&N IMRT treatment plans. There is no statistically significant difference between both point dose verification methods based upon the t-test for comparing two means.

중준위 조사선량율 측정용 전리함의 설계 및 특성 (A Fabrication and Properties of Ionization Chamber Using Madium Exposure Rate)

  • 우홍;김성환;강희동
    • 한국의학물리학회지:의학물리
    • /
    • 제7권2호
    • /
    • pp.29-40
    • /
    • 1996
  • 조사선량율 5mR/h 이상에서 동작하는 원통형 전리함을 설계ㆍ제작하고 상용의 전류계를 이용하여 전하수집 특성을 조사하였다. 전리함은 전체 길이 15.5cm, 직경 5.22cm인 원통형이고 활성체적은 190.4㎤이다. 전리함의 전극은 벽면, 중심축 및 보호전극으로 구성하고, 이들을 동심축상에 배치하여 바탕전류가 8.39$\times$$10^{-14}$ $\pm$1.5$\times$$10^{-15}$ A이 되게 하였다. 전리함에 인가된 전입이 400V일 때 Cs$^{137}$에 대하여 99.7%의 수집효율을 보였으며, 상용의 선량계와 비교한 결과 교정정수 4.531$\times$19$^{7}$ R/C를 구하였다. 에너지 응답특성은 Cs$^{137}$ 을 1로 하였을 때 Am$^{241}$과 Co$^{60}$ 는 각각 1.30, 1.05로 나타났다. 방사선이 전리함의 측면으로 입사할 경우 입사방향에 따른 응답특성의 차이는 무시할 수 있었다.

  • PDF

시험선원을 이용한 기준 전리함의 감도변화와 임상필드전리함의 성능 안정성 비교 (Comparison the reference ion chamber in using the radioactive check source and field ion chamber for output dose for Co-60 source of remote afterloading system)

  • 최태진
    • 한국의학물리학회지:의학물리
    • /
    • 제12권2호
    • /
    • pp.141-146
    • /
    • 2001
  • 치료효과를 보증하기 위해서는 조사선량의 5% 이내의 선량오차가 방사선생물학적 의미가 높은 것으로 잘 알려져 있다. 따라서 종양치료를 위한 강내조사 선원이나 선형가속기의 고선량율의 선량 평가는 정확하고 안정적 평가가 이루어져야 된다. 선량을 평가 교정하기 위해 전리함의 교정 인정기관의 교정상수를 유지하기 위해 선진국에서는 기하학적으로 고정된 표준선원과 전리함의 사용을 오래 전부터 권고해 왔다. 본 연구는 전리함의 감도 변화를 측정할 수 있는 Sr-90 시험선원을 이용한 임의의 기준 전리함의장기간 안정성이 1.00$\pm$0.01 의 오차 범위에 있음을 알 수 있었고, 고선량률 원격강내조사선원인 Co-60 선원에 대한 기준전리함의 출력선량에 대한 임상측정용 전리함의 출력선량은 평균 0.997 $\pm$ 0.01의 오차범위에서 평가될 수 있었으며, 최대오차는 예상선량에 -2.5% 였다. 이 실험을 통해 반감기가 긴 시험선원을 이용하여 임상 측정용 공기전리함의 안정적 성능을 유지할 수 있음을 알 수 있다.

  • PDF