• Title/Summary/Keyword: Calculated AC/A

Search Result 267, Processing Time 0.032 seconds

Prediction of Microshrinkage Porosity in Thin Al-alloy Permanent Mold Castings

  • Lee, Zin-Hyoung
    • Journal of Korea Foundry Society
    • /
    • v.11 no.1
    • /
    • pp.44-53
    • /
    • 1991
  • The proper feeding conditions for thin Al-Alloy (AA336, JIS AC8A) castings in permanent mold were investigated to eliminate microshrinkage porosity. 5mm-thick plates (200mm long, 60mm wide) were cast with increasing padding taper from 0 to 5% under different conditions : (1) constant mold temperature of $350^{\circ}C$, (2) continuous production with uniform mold thickness (10mm), (3) continuous production with a negative taper of 2.5% in mold thickness (thickness decreasing in direction to riser). The test casting were machined off to the midplane and the shrinkage porosity was examined visually. The critical padding taper which can just eliminate the shrinkage porosity was determined for each condition, i.e. : (1) 4.5% at the constant mold temperature, (2) 3.5% for continuous production with the uniform mold thickness (3) 1.5% for continuous production with the taper in mold thickness. A computer simulation by a finite difference analysis program was applied to the test casting. The liquid fraction gradient (LFG) and the temperature gradient divided by the square root of the cooling rate (G /SR) were calculated at the end of solidification and compared with the shrinkage porosity area in the castings. For the case of constant mold temperature, LFG is a better parameter to predict shrinkage porosity than G /SR and its critical value is around 11%/cm. But for the case of continuous production, neither LFG nor G /SR could be a reliable parameter. The experimental results about the critical padding taper are of practical interest for designing permanent molds and castings. The computer simulation results stimulate further research to be directed on the prediction of centerline microshrinkage porosity in continuous production.

  • PDF

Development of an Intelligent Charger with a Battery Diagnosis Function Using Online Impedance Spectroscopy

  • Nguyen, Thanh-Tuan;Doan, Van-Tuan;Lee, Geun-Hong;Kim, Hyung-Won;Choi, Woojin;Kim, Dae-Wook
    • Journal of Power Electronics
    • /
    • v.16 no.5
    • /
    • pp.1981-1989
    • /
    • 2016
  • Battery diagnosis is vital to battery-based applications because it ensures system reliability by avoiding battery failure. This paper presents a novel intelligent battery charger with an online diagnosis function to circumvent interruptions in system operation. The charger operates in normal charging and diagnosing modes. The diagnosis function is performed with the impedance spectroscopy technique, which is achieved by injecting a sinusoidal voltage excitation signal to the battery terminals without the need for additional hardware. The impedance spectrum of the battery is calculated based on voltage excitation and current response with the aid of an embedded digital lock in amplifier in a digital signal processor. The measured impedance data are utilized in the application of the complex nonlinear least squares method to extract the battery parameters of the equivalent circuit. These parameters are then compared with the reference values to reach a diagnosis. A prototype of the proposed charger is applied to four valve-regulated lead-acid batteries to measure AC impedance. The results are discussed.

Control Strategy Compensating for Unbalanced Grid Voltage Through Negative Sequence Current Injection in PMSG Wind Turbines

  • Kang, Jayoon;Park, Yonggyun;Suh, Yongsug;Jung, Byoungchang;Oh, Juhwan;Kim, Jeongjoong;Choi, Youngjoon
    • Proceedings of the KIPE Conference
    • /
    • 2013.07a
    • /
    • pp.244-245
    • /
    • 2013
  • This paper proposes a control algorithm for permanent magnet synchronous generator with a back-to-back three-level neutral-point clamped voltage source converter in a medium-voltage offshore wind power system under unbalanced grid conditions. The proposed control algorithm particularly compensates for the unbalanced grid voltage at the point of common coupling in a collector bus of offshore wind power system. This control algorithm has been formulated based on the symmetrical components in positive and negative rotating synchronous reference frames under generalized unbalanced operating conditions. Instantaneous active and reactive power are described in terms of symmetrical components of measured grid input voltages and currents. Negative sequential component of ac input current is injected to the point of common coupling in the proposed control strategy. The amplitude of negative sequential component is calculated to minimize the negative sequential component of grid voltage under the limitation of current capability in a voltage source converter. The proposed control algorithm makes it possible to provide a balanced voltage at the point of common coupling resulting in the generated power of high quality from offshore wind power system under unbalanced network conditions.

  • PDF

Development of Aging Diagnosis Device Through Real-time Battery Internal Resistance Measurement

  • Kim, Sang-Bum;Lee, Sang-Hyun
    • International Journal of Internet, Broadcasting and Communication
    • /
    • v.14 no.2
    • /
    • pp.129-135
    • /
    • 2022
  • Currently, the rapid growth of electric vehicles and the collection and disposal of waste batteries are becoming a social problem. The purpose of this paper is to propose a fast and efficient battery screening method through a safe inspection and storage method according to the collection and storage of waste batteries of electric vehicles. In addition, as the resistance inside the waste battery increases, an instantaneous voltage drop occurs, and there is a risk of overcharging and overdischarging compared to the initial state of the battery. Accordingly, there are great difficulties in operation, so the final goal of this study is to develop a device for diagnosing aging through real-time battery internal resistance measurement. Final result As a result of simulation of the internal resistance measurement test circuit through external impedance (AC), the actual simulation value was 0.05Ω, RS = Vrms / Irms => Vrms = 8.0036mV, Irms = 162.83Ma. Substitute the suggested method. The result was calculated as Rs = 0.0495Ω. It is possible to measure up to 64 impedances inside the aging diagnostic equipment that enables real-time monitoring of the developed battery cells, and the range can be changed according to the application method.

AC Current Sensor Using Air Core (공심코어를 사용한 교류전류 센서)

  • Park, Young-Tae;Jung, Jae-Kap
    • Journal of the Korean Magnetics Society
    • /
    • v.15 no.1
    • /
    • pp.48-52
    • /
    • 2005
  • This paper describes a current sensor for precision current measurement of an electronic watt-hour meter that is going to install in houses in the future. As the current sensor is based on an cored principle (the Rogowski principle) it is not subject to usual limitations of saturation and non-linearity of general current transformers. An advantage of the developed current sensor is that non-linearity error in low current range is improved and the construction can be kept simple using an air core. We present a magnetic field analysis of the sensor using a finite-element solver. We compared the measured values versus the calculated values.

The Evaluations of Phoria and AC/A Ratio by Watching 3D TV at Near (3D TV 근거리 시청에 따른 사위도와 조절성폭주비 평가)

  • Son, Jeong-Sik;Kim, Dong-Su;Kim, Jung-Ho;Kim, Jae-Do;Hamacher, Alaric;Yu, Dong-Sik
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.20 no.3
    • /
    • pp.319-324
    • /
    • 2015
  • Purpose: This study was designed to evaluate the changes of phoria and calculated AC/A ratio, and their recovery time points by watching 3D television (3D TV). Methods: 50 subjects (male 30, female 20) of 20s to 40s ages who can watch 3D, were measured phoria using a Howell phoria card at 3 m for distance and 40 cm for near. The phoria was evaluated before watching 3D TV and every 10 minutes from starting of watching 3D TV for 30 minutes, and every 5 minutes after finishing of watching 3D TV for 30 minutes again. Results: For the distance phoria during and after watching 3D TV, it was increased to more exophoria $-0.98{\pm}1.37{\Delta}$ (prism diopters) after 10 minutes from starting of 3D TV watching (p=0.063) and increased to more exophoria $-1.00{\pm}1.28{\Delta}$ after 30 minutes (p=0.024), and started to decrease after finishing of watching 3D TV and recovered to the level of before 3D TV watching ($-0.78{\pm}1.11{\Delta}$) after 20 minutes (p=0.32) with comparing to phoria of before watching 3D TV ($-0.80{\pm}1.12{\Delta}$). For the near phoria, it was also increased to more exophoria $-5.71{\pm}4.45{\Delta}$ after 10 minutes from starting of watching 3D TV (p=0.000) and $-6.58{\pm}4.36{\Delta}$ after 30 minutes (p=0.000), and started to decrease after finishing of watching 3D TV and recovered to the level of before watching 3D TV after 20 minutes ($-4.34{\pm}3.67{\Delta}$) (p=0.32) with comparing to the phoria of before watching 3D TV ($-4.36{\pm}3.66{\Delta}$). AC/A ratio was decreased from $4.92{\pm}1.17{\Delta}/D$ for before 3D TV watching to $4.11{\pm}1.50{\Delta}/D$ for after 30 minutes from starting of watching 3D TV (p=0.000), and increased after the end of watching 3D TV and recovered to the level of before 3D TV watching ($4.93{\pm}1.18{\Delta}/D$) after 25 minutes (p=0.598). Conclusions: During watching 3D TV at near, it showed a tendency of convergence insufficiency by decrease of calculated AC/A ratio as result that exophoria at near was higher increased than exophoria at distance. However, the increased exophoria at both near and distance was recovered to the level of base line after 25 minutes from the end of watching 3D TV. Through this study, it seems to need rational proposals of advice for watching 3D TV.

Scheme to Improve the Line Current Distortion of PFC Using a Predictive Control Algorithm

  • Kim, Dae Joong;Park, Jin-Hyuk;Lee, Kyo-Beum
    • Journal of Power Electronics
    • /
    • v.15 no.5
    • /
    • pp.1168-1177
    • /
    • 2015
  • This paper presents a scheme to improve the line current distortion of power factor corrector (PFC) topology at the zero crossing point using a predictive control algorithm in both the continuous conduction mode (CCM) and discontinuous conduction mode (DCM). The line current in single-phase PFC topology is distorted at the zero crossing point of the input AC voltage because of the characteristic of the general proportional integral (PI) current controller. This distortion degrades the line current quality, such as the total harmonic distortion (THD) and the power factor (PF). Given the optimal duty cycle calculated by estimating the next state current in both the CCM and DCM, the proposed predictive control algorithm has a fast dynamic response and accuracy unlike the conventional PI current control method. These advantages of the proposed algorithm lower the line current distortion of PFC topology. The proposed method is verified through PSIM simulations and experimental results with 1.5 kW bridgeless PFC (BLPFC) topology.

Economic Analysis of a Residential Ground-Source Heat Pump System (단독주택용 지열원 열펌프 시스템의 경제성 분석)

  • Sohn, Byong-Hu;Kang, Shin-Hyung;Lim, Hyo-Jae
    • New & Renewable Energy
    • /
    • v.3 no.4
    • /
    • pp.31-37
    • /
    • 2007
  • Because of their low operating and maintaining costs, ground-source heat pump(GSHP) systems are an increasingly popular choice for providing heating, cooling and water heating to public and commercial buildings. Despite these advantages and the growing awareness, GSHP systems to residential sectors have not been adopted in Korea until recently. A feasibility study of a residential GSHP system was therefore conducted using the traditional life cycle cost(LCC) analysis within the current electricity price framework and potential scenarios of that framework. As a result, when the current residential electricity costs for running the GSHP system are applied, the GSHP system has weak competitiveness to conventional HV AC systems considered. However, when the operating costs are calculated in the modified price frameworks of electricity, the residential GSHP system has the lower LCC than the existing cooling and heating equipments. The calculation results also show that the residential GSHP system has lower annual prime energy consumption and total pollutant emissions than the alternative HVAC systems considered in this work.

  • PDF

Novel State-of-Charge Estimation Method for Lithium Polymer Batteries Using Electrochemical Impedance Spectroscopy

  • Lee, Jong-Hak;Choi, Woo-Jin
    • Journal of Power Electronics
    • /
    • v.11 no.2
    • /
    • pp.237-243
    • /
    • 2011
  • Lithium batteries are widely used in mobile electronic devices due to their higher voltage and energy density, lighter weight and longer life cycle when compared to other secondary batteries. In particular, a high demand for lithium batteries is expected for electric cars. In the case of the lithium batteries used in electric cars, driving distance must be calculated accurately and discharging should not be done below a level that makes it impossible to crank. Therefore, accurate information on the state-of-charge (SOC) becomes an essential element for reliable driving. In this paper, a novel method for estimating the SOC of lithium polymer batteries using AC impedance is proposed. In the proposed method, the parameters are extracted by fitting the measured impedance spectrum on an equivalent impedance model and the variation in the parameter values at each SOC is used to estimate the SOC. Also to shorten the long length of time required for the measurement of the impedance spectrum, a novel method is proposed that can extract the equivalent impedance model parameters of lithium polymer batteries with the impedance measured at only two specific frequencies. Experiments are conducted on lithium polymer batteries, with similar capacities, made by different manufacturers to prove the validity of the proposed method.

A Study on Power Conversion System for Photovoltaic Generation (태양광 발전용 전력변환장치에 관한 연구)

  • 박정환;장수형;이성근;안병원;김윤식
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2001.05a
    • /
    • pp.437-442
    • /
    • 2001
  • Recently, transformerless inverters have been studied to reduce sizes and costs of utility-connected PV systems. This paper presents a transformerless PV inverter using a two-phase boost converter of reduced ripples in input current and output voltage, low voltage stress of semiconductor device and reduced size of input reactor. And new PWM method is introduced, whose on-off time is calculated from simultaneous equation induced by fourier series. To verify a validity of the proposed transformerless inverter, computer simulation has been carried out.

  • PDF