• Title/Summary/Keyword: Cage Type

Search Result 163, Processing Time 0.027 seconds

Biomechanical Efficacy of a Combined Flexible Cage with Pedicle Screws with Spring rods: A Finite Element Analysis (Spring rod를 사용한 척추경 나사못과 동반 시술된 Flexible cage의 생체역학적 효과)

  • Kim, Y.H.;Park, E.Y.;Kim, W.H.;Hwang, S.P.;Park, K.W.;Lee, Sung-Jae
    • Journal of Biomedical Engineering Research
    • /
    • v.38 no.1
    • /
    • pp.9-15
    • /
    • 2017
  • Recently, flexible cages have been introduced in an attempt to absorb and reduce the abnormal load transfer along the anterior parts of the spine. They are designed to be used with the pedicle screw systems to allow some mobility at the index level while containing ROM at the adjacent level. In this study, a finite element (FE) study was performed to assess biomechanical efficacies of the flexible cage when combined with pedicle screws with flexible rods. The post-operated models were constructed by modifying the L4-5 of a previously-validated 3-D FE model of the intact lumbar spine (L2-S1): (1) Type 1, flexible cage only; (2) Type 2, pedicle screws with flexible rods; (3) Type 3, interbody fusion cage plus pedicle screws with rigid rods; (4) Type 4, interbody fusion cage plus Type 2; (5) Type 5, Type 1 plus Type 2. Flexion/extension of 10 Nm with a compressive follower load of 400N was applied. As compared to the Type 3 (62~65%) and Type 4 (59~62%), Type 5 (53~55%) was able to limit the motion at the operated level effectively, despite moderate reduction at the adjacent level. It was also able to shift the load back to the anterior portions of the spine thus relieving excessively high posterior load transfer and to reduce stress on the endplate by absorbing the load with its flexible shape design features. The likelihood of component failure of flexble cage remained less than 30% regardless of loading conditions when combined with pedicle screws with flexible rods. Our study demonstrated that flexible cages when combined with posterior dynamic system may help reduce subsidence of cage and degeneration process at the adjacent levels while effectively providing stability at the operated level.

Hydrodynamic Forces on Fish Cage Systems under the Action of Waves and Current (가두리 시설이 파랑과 흐름에 의해 받는 유체력 특성)

  • Kim, Tae-Ho;Kim, Chang-Gil;Kim, Ho-Sang;Baik, Chul-In;Ryu, Cheong-Ro
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.38 no.3
    • /
    • pp.190-196
    • /
    • 2002
  • In order to analyze the hydrodynamic forces on fish cage systems, made of frames and nettings, under waves and current, hydraulic model experiments for square type and circular type of fish cage system were carried out in a towing tank. Both cage systems consist of net cages supported by floating frames made of two concentric pipes and four weights hanging from the bottom corners of the nets. There was little difference in the hydrodynamic force on the square type of fish cage system by wave heading under regular waves and the peak frequency of the force on each cage system was in a good agreement with that of induced irregular wave. In addition, it was also observed that the circular type of cage system was more stable to the action of waves and current than the square type.

Effects of Furnished Cage Type on Behavior and Welfare of Laying Hens

  • Li, Xiang;Chen, Donghua;Li, Jianhong;Bao, Jun
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.29 no.6
    • /
    • pp.887-894
    • /
    • 2016
  • This study was conducted to compare the effects of layout of furniture (a perch, nest, and sandbox) in cages on behavior and welfare of hens. Two hundred and sixteen Hyline Brown laying hens were divided into five groups (treatments) with four replicates per group: small furnished cages (SFC), medium furnished cages type I (MFC-I), medium furnished cages type II (MFC-II), and medium furnished cages type III (MFC-III) and conventional cages (CC). The experiment started at 18 week of age and finished at 52 week of age. Hens' behaviors were filmed during the following periods: 8:00 to 10:00; 13:00 to 14:00; 16:00 to 17:00 on three separate days and two hens from each cage were measured for welfare parameters at 50 wk of age. The results showed that feeding and laying of all hens showed no effect by cage type (p>0.05), and the hens in the furnished cages had significantly lower standing and higher walking than CC hens (p<0.05). The birds in MFC-III had significant higher preening, scratching and feather-pecking behavior than in the other cages (p<0.05). No difference in nesting behavior was found in the hens between the furnished cages (p>0.05). The hens in MFC-I, -II, and -III showed a significant higher socializing behavior than SFC and CC (p<0.05). The lowest perching was for the hens in SFC and the highest perching found for the hens in MFC-III. Overall, the hens in CC showed poorer welfare conditions than the furnished cages, in which the feather condition score, gait score and tonic immobility duration of the hens in CC was significantly higher than SFC, MFC-I, MFC-II, and MFC-III (p<0.05). In conclusion, the furnished cage design affected both behavior and welfare states of hens. Overall, MFC-III cage design was better than SFC, MFC-I, and MFC-II cage designs.

The Relationship Between Cage Floor Preferences and Performance in Broiler Chickens

  • Zulkifli, I.;Khatijah, A. Siti
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.11 no.3
    • /
    • pp.234-238
    • /
    • 1998
  • Two experiments were conducted with broiler chickens to determine cage floor preferences, the strength of preference for a particular floor type and to evaluate the effect of rearing broilers on the preferred cage floor on productivity. In experiment 1, chicks when offered free access to either wire (WF) or plastic (PF) mesh flooring, preferred the former. However, when the perferred floor type (WF) was illuminated at 800 lux, birds spent longer time on PF. Also provision of incandescent lamps at PF resulted in broilers spending significantly longer period on WF. In experiment 2, while floor type had no effect on growth of female chicks throughout the duration of study, male chicks grown on PF were heavier than their WF counterparts on Days 21, 28, 35 and 42. Neither livability, nor incidence of breast blisters and leg deformities was affected by floor type.

Comparative Study on Biomechanical Behavior of Various Cervical Stand-Alone Cage Designs (경추용 일체형 추간체 유합 보형재의 디자인 변화에 따른 생체역학적 효과 비교 연구)

  • Park, Kwang Min;Jung, Tae Gon;Jeong, Seung Jo;Lee, Sung Jae
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.33 no.11
    • /
    • pp.943-950
    • /
    • 2016
  • The purpose of this study was to evaluate and compare by finite element analysis the biomechanical performance, in terms of cervical stand-alone cage screw insert angle (Type 3 - 5: 2 Screws) and screw arrangement (Type 6 and 7: 3 Screws / Type 8 and 9: 4 Screws), and the range of motion (ROM) of traditional anterior cervical discectomy of a fusion device (Type 1: Cage / Type 2: Cage + ACP). Our study suggests that the biomechanical behavior of a postoperative cervical spine could indeed be influenced by design features, such as screw angle and number of screws. In particular, ROM and the risk of subsidence were more sensitive during extension about type 5 (Insert Angle $20^{\circ}$). Our study also suggested that the number of screw asymmetries between up and down for type 6 and 7 could result in differences in the risk of screw fracture manifesting in different clinical aspects.

Physiological Profile of Growing Rats: Effects of Cage Type and Cage Density

  • Yildiz, A.;Hayirli, A.;Okumus, Z.;Kaynar, O.;Kisa, F.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.20 no.2
    • /
    • pp.263-272
    • /
    • 2007
  • This experiment was conducted to examine the effects of cage type (CT) and cage density (CD) on physiological variables in growing rats. Sprague Dawley rats (n=108) weighing an average of 46 g were housed in metallic cage with woodchip bedding (MCWB), metallic cage with wire mesh (MCWM), and plastic shoebox with woodchip bedding (PCWB) separately by sex at normal ($160-cm^2/rat$, ND) and high ($80-cm^2/rat$, HD) CD from 3 to 10 wks of age. All cages were in dimension of $24{\times}40{\times}20$ cm ($W{\times}D{\times}H$). At the end of the experiment, blood samples were collected and 6 rats from each cage were sacrificed. No death was observed among rats at ND, whereas mortality rate at HD was 22.3% for males and 13.9% for females. Heart weight was affected by CT. Doubling CD caused 23, 11.8, 17.9, 8.6, 6.9, and 16.4% decreases in BW and weights of heart, liver, kidney, testis, and ovary, respectively. Except for adrenal gland, other organs for males were heavier than for females. Liver weight of males and females responded differently to CT and CD. Comparing with females, males had 7.3 and 5.2% heavier and 9.9% lighter liver weights in MCWB, MCWM, and PCWB, respectively. As CD doubled, liver weight for males and females decreased by 22.4 and 13.1%, respectively. Mean adrenal gland weight increased by 8.4% and decreased by 9.7% for males and females, respectively, with doubling CD. CT affected glucose, TG, Ca, and ALP levels. However, CD did not alter blood chemistry. Rats housed in metallic cages had greater neutrophil count and neutrophil:lymphocyte ratio than rats housed in plastic cages. Doubling CD caused a 24.2% increase in lymphocyte count. There were CT by CD, CT by sex, and CD by sex interaction effects on lymphocyte count. Doubling CD caused 0.1% decrease and 49.8 and 26.7% increases in lymphocyte count for rats housed in MCWB, MCWM, and PCWB, respectively. Comparing with females, lymphocyte count for males housed in MCWB, MCWM, and PCWB had 8.9 and 12.9% greater and 30.3% less lymphocyte counts, respectively. Lymphocyte count decreased by 4.12% for males, whereas it increased by 61.0% for females as CD doubled. Doubling CD resulted in 2.5 and 2.3% increases in erythrocyte count and hematocrit value. These data suggest that animals perform better in metallic cages than in plastic cages and that cage density had pronounceable effects on physiological parameters in a cage type and sex dependent-manner.

The analysis on magnetic flux by the rotor slot of Squirrel-cage induction motor (농형유도전동기(籠型誘導電動機)의 회전자(回轉子) 슬롯 형상(形狀)에 따른 자속밀도(磁束密度) 해석(解析))

  • Oh, Young-Soo;Lee, Eun-Woong;Lee, Dong-Ju;Moon, Jae-Yun
    • Proceedings of the KIEE Conference
    • /
    • 1998.07a
    • /
    • pp.299-301
    • /
    • 1998
  • The torque characteristic of an induction motor is affected greatly by the slot shape at which the conductors of the rotor are located. In this paper, the three analysis model; general type, deep slot type, double squirrel-cage type, of which the slot shapes are different, were analyzed by FEM at no load, at rated load, and at standstill respectively. The flux distribution and air-gap flux density were also obtained. From the above result, it was confirmed that the analysis models of deep slot and double squirrel-cage had more desirable characteristics than those of general squirrel-cage.

  • PDF

NMDA-type Glutamatergic Modulation in Dopaminergic Activation Measured by Apomorphine-Induced Cage Climbing Behaviors

  • Jang, Choon-Gon;Lee, Seok-Yong
    • Archives of Pharmacal Research
    • /
    • v.24 no.6
    • /
    • pp.613-617
    • /
    • 2001
  • The present study examined the hypothesis that NMDA, AMPA/Kainate, and metabotropic (mGlu) glutamate receptors contribute to a behavioral stimulation induced by activation of dopamine receptors by comparing responses in apomorphine-induced cage climbing behaviors in mice. MK-801, CNQX, and MCPG were served as the NMDA receptor, AMPA/Kainate receptor, and mGlu receptor antagonist, respectively, to elucidate the glutamatergic modulation in apomorphine-induced eopaminergic activation in mice. Drugs were administered intracerebroventricularly (i.c.v.) into the mouse brain 15 min before the apomorphine treatment (2 mg/kg, s.c.). 1.c.v. injection of MK-801 inhibited the apomorphine-induced cage climbing behavior dose-dependently. However, treatments with CNQX and MCPG did not any significant change in apomorphine-induced cage climbing behavior in mice. These results suggest that stimulation of NMDA type of glutamate receptors could contribute to the dopaminergic sti mutation, but not AMPA/Kainate and mGlu type glutamate receptors.

  • PDF

Development of a multi-functional companion animal cage design - Focusing on small companion dogs - (다기능 반려동물 이동장 디자인 개발- 소형 반려견을 중심으로 -)

  • Mi-Hwa Choi;Chanmi Lee;Nahyun Yoo;Hye-rim Yang
    • The Research Journal of the Costume Culture
    • /
    • v.31 no.2
    • /
    • pp.262-276
    • /
    • 2023
  • This study aims to develop a multi-functional cage for dogs as a house to reduce their anxiety when they go out using cages. This study investigates the types and characteristics of cages and cage preference by surveying men and women in their 20s who use them. The cage product reviews are also analyzed. The research results are as follows: First, domestic dog cages are classified into crate, shoulder, cross (sling bag), backpack, carrier, and stroller types. The crate type is easy to clean and can be used as a house, but it is bulky and therefore inconvenient to carry when using public transportation. The shoulder type is a fabric material with good air permeability but has the disadvantage of being easily soiled. It can be used as a house and is light weight, making it convenient when using public transportation. Second, as a result of consumer research, respondents prefer the shoulder-type fabric over the crate-type plastic material. Third, from the shoulder-type product review, the shape stability, companion dogs' psychological safety, the wearability of companions, and management convenience are derived. Fourth, based on the survey results, a multi-functional cage is developed taking into account the companion dog, companion person, and functional factors.

A Study on the outside rotor type double squirrel cage Induction motor (외측회전형 이중 농형 유도전동기에 관한 연구)

  • 김현수;배철오;안병원
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.27 no.6
    • /
    • pp.776-782
    • /
    • 2003
  • This paper describes a newly developed double squirrel cage induction motor in which the rotor is located outside the stator. The outside rotor type brushless dc motor has been used for VTR's head drum and PC's cooling fan, but this kind of induction motor has not been developed yet. The parameters of outside rotor type induction motor were measured from the locked rotor test and no load test. It is possible to determine the parameters which are presented in the steady-state equivalent-circuit of the outside rotor type induction motor. Load test of induction motor was carried out using a dynamometer. For the characteristics of torque, efficiency, power factor and output. the developed double squirrel cage induction motor is compared with the ordinary induction motor It is believed that the results of this paper can be used for the development of the outside rotor type induction motor.