• 제목/요약/키워드: Cadaver Shoulder

검색결과 11건 처리시간 0.029초

Overview of Various Measurement Tools for Shoulder Kinematics

  • Kim, Doo Sup;On, Myoung Gi;Yeom, Jun Seop
    • Clinics in Shoulder and Elbow
    • /
    • 제20권4호
    • /
    • pp.244-249
    • /
    • 2017
  • Shoulder kinematics is important, as it is associated with shoulder arthropathy and pain mechanisms. Various static and dynamic analysis methods are prevalent for shoulder kinematics. These include 2-dimensional plane x-ray, computed tomography, and magnetic resonance imaging, cadaver study, electromagnetic motion analysis, transcortical bone pins technique, and in vivo 3-dimensional motion analysis. Although these methods provide the value of the shoulder kinematics angle, they are unable to explain why such changes occur. Since each method has its pros and cons, it is important to understand all factors accurately, and to choose a method that best meets the purpose of the researcher.

Ten technical aspects of baseplate fixation in reverse total shoulder arthroplasty for patients without glenoid bone loss: a systematic review

  • Reinier W.A. Spek;Lotje A. Hoogervorst;Rob C. Brink;Jan W. Schoones;Derek F.P. van Deurzen;Michel P.J. van den Bekerom
    • Clinics in Shoulder and Elbow
    • /
    • 제27권1호
    • /
    • pp.88-107
    • /
    • 2024
  • The aim of this systematic review was to collect evidence on the following 10 technical aspects of glenoid baseplate fixation in reverse total shoulder arthroplasty (rTSA): screw insertion angles; screw orientation; screw quantity; screw length; screw type; baseplate tilt; baseplate position; baseplate version and rotation; baseplate design; and anatomical safe zones. Five literature libraries were searched for eligible clinical, cadaver, biomechanical, virtual planning, and finite element analysis studies. Studies including patients >16 years old in which at least one of the ten abovementioned technical aspects was assessed were suitable for analysis. We excluded studies of patients with: glenoid bone loss; bony increased offset-reversed shoulder arthroplasty; rTSA with bone grafts; and augmented baseplates. Quality assessment was performed for each included study. Sixty-two studies were included, of which 41 were experimental studies (13 cadaver, 10 virtual planning, 11 biomechanical, and 7 finite element studies) and 21 were clinical studies (12 retrospective cohorts and 9 case-control studies). Overall, the quality of included studies was moderate or high. The majority of studies agreed upon the use of a divergent screw fixation pattern, fixation with four screws (to reduce micromotions), and inferior positioning in neutral or anteversion. A general consensus was not reached on the other technical aspects. Most surgical aspects of baseplate fixation can be decided without affecting fixation strength. There is not a single strategy that provides the best outcome. Therefore, guidelines should cover multiple surgical options that can achieve adequate baseplate fixation.

High-Fidelity Perforator Visualization for Cadaver Dissection in Surgical Training

  • AllenWei Jiat Wong;Yee Onn Kok;Khong Yik Chew;Bien Keem Tan
    • Archives of Plastic Surgery
    • /
    • 제50권6호
    • /
    • pp.621-626
    • /
    • 2023
  • In the first half of the third century B.C., Herophilus and Erasistratus performed the first systematic dissection of the human body. For subsequent centuries, these cadaveric dissections were key to the advancement of anatomical knowledge and surgical techniques. To this day, despite various instructional methods, cadaver dissection remained the best way for surgical training. To improve the quality of education and research through cadaveric dissection, our institution has developed a unique method of perforator-preserving cadaver injection, allowing us to achieve high-fidelity perforator visualization for dissection studies, at low cost and high efficacy. Ten full body cadavers were sectioned through the base of neck, bilateral shoulder, and hip joints. The key was to dissect multiple perfusing arteries and draining veins for each section, to increase "capture" of vascular territories. The vessels were carefully flushed, insufflated, and then filled with latex dye. Our injection dye comprised of liquid latex, formalin, and acrylic paint in the ratio of 1:2:1. Different endpoints were used to assess adequacy of injection, such as reconstitution of eyeball volume, skin turgor, visible dye in subcutaneous veins, and seepage of dye through stab incisions in digital pulps. Dissections demonstrated the effectiveness of the dye, outlining even the small osseous perforators of the medial femoral condyle flap and subconjunctival plexuses. Our technique emphasized atraumatic preparation, recreation of luminal space through insufflation, and finally careful injection of latex dye with adequate curing. This has allowed high-fidelity perforator visualization for dissection studies.

Scapular spine base fracture with long outside-in superior or posterior screws with reverse shoulder arthroplasty

  • Eroglu, Osman Nuri;Husemoglu, Bugra;Basci, Onur;Ozkan, Mustafa;Havitcioglu, Hasan;Hapa, Onur
    • Clinics in Shoulder and Elbow
    • /
    • 제24권3호
    • /
    • pp.141-146
    • /
    • 2021
  • Background: The purpose of the present study was to determine how long superior screws alone or in combination with posterior placement of metaglene screws protruding and penetrating into the scapular spine in reverse total shoulder arthroplasty affect the strength of the scapular spine in a fresh cadaveric scapular model. Methods: Seven fresh cadaver scapulas were allocated to the control group (short posterior and superior screws) and seven scapulars to the study group (spine base fixation with a four long screws, three with both long superior and long posterior screws). Results: The failure load was lower in the spine fixation group (long screw, 869 N vs. short screw, 1,123 N); however, this difference did not reach statistical significance (p>0.05). All outside-in long superior or superior plus posterior screws failed due to scapular spine base fracture; failures in the short screw group were due to acromion fracture. An additional posterior outside-in screw failed to significantly decrease the failure load of the acromion spine. Conclusions: The present study highlights the significance of preventing a cortical breach or an outside-in configuration when a superior or posterior screw is inserted into the scapular spine base.

Distal biceps tendon injection

  • van der Vis, Jacqueline;Janssen, Stein J.;Bleys, Ronald L.A.W.;Eygendaal, Denise;van den Bekerom, Michel P.J.
    • Clinics in Shoulder and Elbow
    • /
    • 제24권2호
    • /
    • pp.93-97
    • /
    • 2021
  • Background: Injection therapy around the distal biceps tendon insertion is challenging. This therapy may be indicated in patients with a partial distal biceps tendon tear, bicipitoradial bursitis and tendinopathy. The primary goal of this study was to determine the accuracy of manually performed injections without ultrasound guidance around the biceps tendon. Methods: Seven upper limb specialists, two general orthopedic specialists, and three orthopedic surgical residents manually injected a cadaver elbow with acrylic dye using an anterior and a lateral infiltration approach. After infiltration the cadaveric elbows were dissected to determine the location of the acrylic dye. Results: In total, 79% of the injections were localized near the biceps tendon. Of these injections, 20% were localized on the radius near the bicipitoradial bursa. In total, 53% of the performed infiltrations were injected by anterior and 47% by lateral approaches. Of the injections near the distal biceps (79%), 47% were injected by an anterior and 53% by a lateral approach. Of the injections on the radius (20%), 33% were injected by anterior and 67% by lateral approach. Of the inaccurate injections (21%), 75% were injected anterior and 25% lateral. Conclusions: Manual infiltration without ultrasound guidance for distal biceps pathology lacks accuracy. We therefore recommend ultrasound guidance for more accurate infiltration.

An Analysis of Stress Pattern in the Coracoclavicular Ligaments with Scapular Movements: A Cadaveric Study Using Finite Element Model

  • Kim, Yoon Sang;Kim, In-Sung;Yoo, Yon-Sik;Jang, Seong-Wook;Yang, Cheol-Jung
    • Clinics in Shoulder and Elbow
    • /
    • 제18권3호
    • /
    • pp.152-158
    • /
    • 2015
  • Background: Acromioclavicular (AC) stability is maintained through a complex combination of soft-tissue restraints that include coracoclavicular (CC), AC ligament and overlying muscles. Among these structures, the role of the CC ligament has continued to be studied because of its importance on shoulder kinematics, especially after AC injury. This study was designed to determine the geometric change of conoid and trapezoid ligaments and resulting stresses on these ligaments according to various scapular motions. Methods: The scapuloclavicular (SC) complex was isolated from a fresh-frozen cadaver by removing all soft tissues except the AC and CC ligaments. The anatomically aligned SC complex was then scanned with a high-resolution computed tomography scanner into 0.6- mm slices. The Finite element model of the SC complex was obtained and used for calculating the stress on different parts of the CC ligaments with simulated movements of the scapula. Results: Average stress on the conoid ligament during anterior tilt, internal rotation, and scapular protraction was higher, whereas the stress on the trapezoid ligament was more prominent during posterior tilt, external rotation, and retraction. Conclusions: We conclude that CC ligament plays an integral role in regulating horizontal SC motion as well as complex motions indicated by increased stress over the ligament with an incremental scapular position change. The conoid ligament is the key structure restraining scapular protraction that might occur in high-grade AC dislocation. Hence in CC ligament reconstructions involving only single bundle, every attempt must be made to reconstruct conoid part of CC ligament as anatomically as possible.

광범위 후방 접근법을 이용한 주관절 강직의 치료 (Treatment of the Stiffness of the Elbow using Posterior Extensile Approach)

  • 유총일;김휘택;손교민;구정모;정철용
    • Clinics in Shoulder and Elbow
    • /
    • 제8권1호
    • /
    • pp.49-56
    • /
    • 2005
  • Purpose: To review the surgical results of stiff elbow using the posterior extensile approach which provides a wide surgical view with a single posterior skin incision. Materials and Methods: From February 1999 to May 2002, we performed 6 surgical correction of stiff elbow using posterior extensile approach and followed the patients more than 1 year. In order to get better result, we performed cadaver study (four elbows of two fresh cadavers). Average duration of follow up was 15.7 months $(14{\sim}21)$. Functional results was analyzed using Brobery and Morrey analysis scale. Results: The approach through the plane between the extensor carpi radialis longus and the extensor carpi radialis brevis was ideal, because it preserves normal anatomy and provides a wide surgical view of the anterior joint. The posterior joint could be approached directly between the medial head of the triceps brachii and brachialis medially, the lateral head of triceps brachii and brachioradialis laterally. In all patients, an improved ROM was obtained with intra and extra-articular adhesiolysis: an average $61.7^{\circ}$ improvement $(50{\sim}75)$. Functional results were as follows: five excellent, one good. In addition, the patients' satisfaction was high since the scar from the operation was only a single line at the posterior surface of the elbow. Conclusion: In the treatment of stiff elbow, posterior extensile approach is thought to be useful because this method provides wide anterior and posterior surgical view.

회전근 개 파열의 봉합에서 UU 봉합법은 변형된 MA(Mason-Allen) 봉합법을 대치할 수 있는가? - UU 봉합법과 변형된 MA 봉합법의 생역학적 비교- (Is the UU Stitch Really Alternative to Modified MA (Mason-Allen) Stitch for Rotator Cuff Repair? - Biomechanical Comparative Study of UU to Modified MA Stitch -)

  • ;고상훈;박기봉;전형민;김태원;임현우;염영진
    • Clinics in Shoulder and Elbow
    • /
    • 제12권2호
    • /
    • pp.207-214
    • /
    • 2009
  • 목적: 관절경 하 회전근 개 봉합에서 일반적으로 건-봉합간 접촉면 (tenon-suture interface) 에 약한부위 (weak link)가 형성되어 있어 관절경 하 회전근 개 봉합은 개방적 봉합술보다 높은 재파열율을 가진다. 이 연구의 목적은 봉합사를 뼈에 고정할 때 관절경으로 사용할 수 있는 UU (Ulsan University) 봉합과 개방적 변형 MA (Mason-Allen) 봉합의 강도를 비교하는 것이다. 대상 및 방법: 한 구의 사체 극상근 건을 채취하여 절반으로 나눈 후 다시 절반을 나누어 사체의 어깨 관절 한 구당 네 개의 건을 만들어 총 24개의 검체를 만들었다. 두 봉합 형태 (UU, MA)는 무작위로 선택하였으며 각각의 건에 시행하였다. 검체는 0.25 Hz에서 5~30N의 조절된 외력하에서 50회 주기 부하 (cyclic loading)를 받았다. 각 검체는 초당 1mm의 전이가 되는 상황하에서 파열이 발생할 때(ultimate tensile load)까지 부하를 받았다. 조건 이완 (condition elongation), peak-to-peak 전이(displacement), 기울기 (stiffness), 최대 인장력 (ultimate tensile load), 파열 양상 (mode of failure) 등을 기록하였다. 결과: 주기 부하 실험에서 두 봉합 형태 간 유의 있는 차이는 없었다. 최대 장력 실험에서 UU 봉합과 변형 MA (Mason-Allen) 봉합 간에 통계학적으로 유의한 차이는 없었다 (109.4 N, and 110.6 N). 양 봉합 형태에서 가장 흔한 파열 양상은 봉합의 빠짐 (suture pull-out)이었다. 결론: UU 봉합과 변형 MA 봉합은 유사한 생역학적 특성을 가진다.