• Title/Summary/Keyword: Cable type

Search Result 511, Processing Time 0.026 seconds

Investigation of On-line Monitoring Method on 1500 V Direct Current Cable of Subway

  • Shen, Xiaojun;Jiang, Xiuchen;Yi, Zeng
    • Transactions on Electrical and Electronic Materials
    • /
    • v.7 no.5
    • /
    • pp.247-251
    • /
    • 2006
  • The traction DC feeder cable is one of the key devices for the safety operation of subway system, but for low voltage DC feeder cable (<3000 V) for subway, little attention has been paid by investigators on its online monitoring technology. With an introduction of cable laying and operation environment for the cable, this paper investigated the on-line monitoring technology of 1500 V DC feeder cable of subway. Firstly, in the text, the fault model of 1500 V DC cable was proposed based on the analysis of the fault type of the DC feeder cable, and then put forward synthetically on-line monitoring discharge signal and DC leakage current signal to assess DC feeder cable insulating state. The results of laboratory experiment prove that the proposed methods are feasible and can be implemented on-line monitor on DC feeder cable of subway.

Measurement of electrical resistance at the Nb_{3}$Sn CICC joint fabricated by sub-cable to sub-cable joining (Nb_{3}$Sn 초전도 CICC의 sub-cable to sub-cable 접합 및 접합저항 측정)

  • 이호진;홍계원;김기백;권선칠;김기만
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 1999.02a
    • /
    • pp.89-92
    • /
    • 1999
  • A small scale joint sample of Nb3Sn CICC was fabricated by sub-cable to sub-cable joining. This joint was produced by parallel insertion of one end of each sub-cable into the sub-cable space of the other side of cable, which can decrease the equivalent electrical resistance at the joint is expected to have average properties, dc resistance and ac losses, in view of the shapes of ITER type joint and strand to strand joint. The 3.8nOhm of dc resistance was measured in the range of 10-200A transport current. The normalized resistivity of the joint was about 6.7 $\mu}$Ohm-$^mm{2}$. Considering the normalized resistivity, the full scale joint prepared by sub-cable to sub-cable joining may have similar joint dc resistance with other conventional full scale joints with a shorter joining length.

  • PDF

First Installation of High Stress EHV XLPE Cable in korea (초고압 고내력 케이블 국내 최초 현장 적용)

  • Oh, J.O.;Cho, S.H.;Lee, S.K.;Kim, H.J.;Oh, D.S.
    • Proceedings of the KIEE Conference
    • /
    • 1999.11d
    • /
    • pp.1057-1059
    • /
    • 1999
  • Recently, increased demand of electrical energy caused additional installation of underground power cable, Industrialization of metro makes civil works difficult. So installed ducts became a key of underground power transmission, LG cable set to work development of high stress cable. LG cable stated in 1996, got a certificate of type test in 1998, and applied at domestic site in Nov. 1999. High stress cable has some merit, decrease of civil cost, reduction of work time, by reason of decrease of dia. and weight, and economical system design, so LG cable has a good merit in comparison with competitive company in domestic and foreign market.

  • PDF

The Development of Swivel Unit for Spot Welding Robots (스폿용접 로봇용 스위블 유닛의 개발)

  • Kim, Yong-Seok;Park, Sung-Ho;Yang, Soon-Young
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.17 no.4
    • /
    • pp.119-125
    • /
    • 2008
  • A new type of swivel unit is suggested in order to complement weak points of the existing. This new type of Swivel unit is developed by adopting a spring type cable which has elasticity and restoring force. To minimize the troubles in the process of manufacturing during operating the new type system, strength analysis and the check of interference between parts are accomplished with CATIA. The check of rotating performance is also carried out to determine the diameter and length of spring type cable by SimDesigner motion analysis. Swivel unit used in the robot spot welding is developed with spring type cable and its usefulness in the industrial field is verified through experiments. This system has been registered for patent.

Quench Simulation and Analysis on Superconducting Cable Systems (초전도 케이블 계통에서의 켄치 모의 및 해석)

  • 김남열;이종범
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.53 no.1
    • /
    • pp.13-21
    • /
    • 2004
  • In the design of superconducting cable systems, quench analysis have to be advanced for applying to a real systems. It is necessary to calculate the current, voltage and resistance during the quench. Simulation program named EMTDC was used to analyze the quench state. Normal zone evaluation and quench development with EMTDC are one of the major features of quench analysis. This paper presents the two kinds of quench control models which are the Switch Control Type and the Fortran Control Type. In case of the quench developing area, the simplicity cable model consist of resistance, inductance and capacitance. The impedance of the pipe type superconducting cable is calculated by numerical analysis method. The resistance and inductance increased during quench. However the variation have an effect on the fault current. The voltage was also developed by resistance and inductance. This paper presents the relationship between the current. voltage, resistance and inductance during quench.

Steady and Transient State Analysis on Three Phase-in One Enclosure Type HTS Cable (3상 일괄형 Pipe Type HTS 케이블의 정상 및 과도상태 해석)

  • Jang, Ju-Yeong;Lee, Jong-Beom;Kim, Yong-Kap
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.10
    • /
    • pp.1748-1753
    • /
    • 2010
  • This paper suggests an improved technique to establish the modeling regarding steady and transient state on three phase-in one cryostat type HTS(High Temperature Superconducting) cable. The proposed modeling is established using EMTP/ATPDraw and TACS and MODELS provided by that. It has higher accuracy than the conventional method, as the actual HTS cable is modelled. Steady and transient state analysis performed by EMTP/ATPDraw calculate the current of conductor, shield and former, respectively. In case of the transient state modeled quench state occurred by a single line-to-ground fault, current of conductor shield and former are also calculated, respectively. Especially, various fault resistances and angles are considered to improve the reliability during transient state analysis. Analysis results reveal that the proposed technique improves the accuracy of modeling.

The Prospects for Underground Transmission System in Korea (특고압 및 초고압 지중송전계통의 장래성 제1부)

  • 이재숙
    • 전기의세계
    • /
    • v.20 no.4
    • /
    • pp.31-36
    • /
    • 1971
  • This is intending to introducdine the pipe type 161KV underground cable system in Capital City of Seoul which will be constructed in 1972 or 1973 by Korea Electric Co using the AID loan and Won currency. In order to make readers to have an easy understanding and a clear view of underground cable transmission line, the first part will be for the introduction of the description on future underground cable system by Mr. E.H.F inch appeared on 1969 Sept. Consulatant Engineer. the second part will introduce our 161KV underground cable system in Seoul and it's feasibility study, and the third part will mention calculation methods of electrical properties of pipe type cable and the results of calculation of our own system.

  • PDF

A Study on the Static Instability Behaviour of the Zetlin Type Cable Dome Structures (Zetlin형 케이블 돔 구조물의 정적 불안정 거동에 관한 연구)

  • 김형석;김승덕;강문명
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2002.10a
    • /
    • pp.541-548
    • /
    • 2002
  • Membrane, cable structure and membrane-cable structural system are more lighter than another common structural system, and these are able to be effectively build Lip spatial structures using axial stiffness. However when the load reach at critical load level, it might be happened snap-through or bifurcation according to the structure's shape, and these collapse mechanism should be very important in the design of structures. So, In this paper we study static instability of Zetlin-type cable dome, one of the hybrid cable dome. Moreover, as the unstable behavior of shell structures are very sensitive to the initial condition, we seek to find the effect of initial condition.

  • PDF

A STUDY ON THE DESIGN, JOINTING, CHARACTERISTIC OF CONDENSER CONE OF SEALING-END FOR 154KV OF CABLE (154KV OF 종단 접속함용 CONDENSER CONE의 설계.접속.특성에 관한 연구)

  • Lee, H.S.;Oh, E.J.;Lee, K.B.
    • Proceedings of the KIEE Conference
    • /
    • 1993.07b
    • /
    • pp.621-623
    • /
    • 1993
  • This paper describes the research in condenser cone of sealing-end for 154kV oil-filled underground cable. We conducted the design based on the results of electric field analysis by electrostatics theory and FEM. In case that condenser cone type EB-A was compared with bell mouth type EB-A, the results of the AC and lightening impulse voltage test showed improvment of 10 percents.

  • PDF

A study on the test methods for detection device of cable fault type and location (케이블 고장 종류, 위치 검출장치 시험 방법에 관한 연구)

  • Oh, Hun;Jeon, Jeong-Chay;Kim, Taek-Hee;Yoo, Jae-Geun;Ko, Bong-Woon
    • Proceedings of the KIPE Conference
    • /
    • 2015.07a
    • /
    • pp.7-8
    • /
    • 2015
  • TDR(Time Domain Reflectometry) technology can detect cable fault type and location. This paper is to evaluate the performance of the cable TDR device. Therefore, this paper describe methods and elements of tests.

  • PDF