Development of Cable Management System for Ship (선박 전선 관리 시스템 개발)

  • Lee, Jae-Hyun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.12 no.11
    • /
    • pp.1987-1992
    • /
    • 2008
  • In recent years, the shape of ship building have been advanced. Thus the system is complex and cable is much used in ship. In this paper, Dijkstra algorithm is used to solve the shortest path of cable laying. Cable laying is given much weight in fable management system of ship. The developed cable management system is cut down on expenses and is improve the operation efficiency for ship building. Therefore, the developed cable management system can be used a support system in order to achieve a management target of company.

The implementation of cable path and overfill visualization based on cable occupancy rate in the Shipbuilding CAD (조선 CAD에서 선박의 Cable 점유율을 기반으로 Cable 경로 및 Overfill 가시화 구현)

  • Kim, Hyeon-Jae;Kim, Bong-Gi
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.11
    • /
    • pp.740-745
    • /
    • 2016
  • Cables are installed for tens of thousands of connections between various pieces of equipment to operate and control a commercial ship. The correct shortest-route data is necessary since these are complicated cable installations. Therefore, an overfill interval commonly exists in the shortest paths for cables as estimated by Dijkstra's algorithm, even if this algorithm is generally used. It is difficult for an electrical engineer to find the overfill interval in 3D cable models because the occupancy rate data exist in a data sheet unlinked to three-dimensional (3D) computer-aided design (CAD). The purpose of this study is to suggest a visualization method that displays the cable path and overfill interval in 3D CAD. This method also provides various color visualizations for different overfill ranges to easily determine the overfill interval. This method can reduce cable-installation man-hours from 7,000 to 5,600 thanks to a decreased re-installation rate, because the cable length calculation's accuracy is raised through fast and accurate reviews based on 3D cable visualization. As a result, material costs can also be reduced.

Form Generation of Cable-Stayed Structures considering Structural Art - by using Graphic Statics - (구조미를 고려한 사장케이블 구조의 형태설계 - 정력학적 도해법 이용 -)

  • Kim, Namhee;Hong, Sung-Gul
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.35 no.4
    • /
    • pp.167-174
    • /
    • 2019
  • Cable-stayed structures provide a lot of possibilities toward the development of innovative structural forms regarding their expressiveness and uniqueness. Such cable-stayed structures, as form-active structures, can obtain a family of alternatives by changing parameters for defining geometric shapes. The concept of graphic statics is utilized to explain the relationship between the load path and structural forms because the load path of cable structures has something to do with their structural geometry. Moreover, this structural geometry has a dominant effect on both structural efficiency and structural elegancy. The proposed design method in this study will help designers conceive innovative structural forms considering structural safety, material efficiency, and structural art altogether.

An optimal design guideline for voltage drop of DC distribution system with batteries (예비축전지를 갖는 배전계통 전압강하의 비용최적 설계)

  • Cho, Il-Kwon;Kim, Marn-Go
    • Proceedings of the KIEE Conference
    • /
    • 1994.11a
    • /
    • pp.400-402
    • /
    • 1994
  • The voltage drop in distribution path of battery-reserved DC power system can affect the total of battery, cable and electricity costs. To determine an optimum voltage drop in distribution path for minimizing the total cost, battery, cable and electricity costs are represented as a function of the voltage drop, respectively, and are summed up to the total cost. An optimum voltage drop is selected as the value giving the minimum total cost. In this paper, a design technique of optimum voltage drop in distribution path of DC power system is proposed to minimize the total of battery, cable and electricity costs. The design procedure is described and design curve for selecting optimum voltage drop is also presented as a function of distribution distance.

  • PDF

Efficient Fault Location Detecting Mechanism for Optical Submarine Cable (해저광케이블 고장지점 탐지기법)

  • Park, Hong-Tae;Yoo, Jae-Duck;Yoon, Suk-Min;Jo, Gi-Rayng;Shin, Hyun-Sik
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.1 no.1
    • /
    • pp.63-69
    • /
    • 2006
  • The optical submarine cable has a long distance cable and the repeater for optical amplification compared to territorial optical cable so conventional OTDR utilization for the optical submarine cable is limited. in case the optical core in the optical submarine cable system cut, by using Coherent OTDR that utilize OTDR path in repeater the cable fault point can be detected and in case the faulty of the copper tube in the cable that provide power for the repeater to amplify optical signal, the ways using the current/voltage characteristic, the capacitance per Km and so on is required. this report suggest efficient fault location detecting mechanism by categorized cable fault type.

  • PDF

Nonlinear Static Analysis of Cable Roof Structures with Unified Kinematic Description

  • LEE, Sang Jin
    • Architectural research
    • /
    • v.18 no.1
    • /
    • pp.39-47
    • /
    • 2016
  • A finite element analysis technology applicable to the prediction of the static nonlinear response of cable roof structure is presented. The unified kinematic description is employed to formulate the present cable element and different strain definitions such as Green-Lagrange strain, Biot strain and Hencky strain can be adopted. The Newton-Raphson method is used to trace the nonlinear load-displacement path. In the iteration process, the compressive stress of a cable element is not allowed. For the verification of the present cable element, four numerical examples are tackled. Finally, numerical results obtained by using the present cable element are provided as new benchmark test results for cable structures under static loads.

Study on Pressure drop characteristics in HTS cable core with two flow passages

  • Lee, Jun-Kyoung;Kim, Seok-Ho;Kim, Hae-Joon;Cho, Jeon-Wook
    • Progress in Superconductivity and Cryogenics
    • /
    • v.10 no.4
    • /
    • pp.33-37
    • /
    • 2008
  • The main objective of this study is to identify the pressure drop characteristics of coolant flow passages of 154kV/1GVA High Temperature Superconducting (HTS) power cable, experimentally. The passages were consisted of two parts, the one is the circular path with spiral ribs in the core to cool the cable conductor layer and the other is annular path with spirally corrugated outer wall to cool the shield layer. Thus the experiments to acquire the pressure drop data were performed with two types of circular spiral tubes and eight types of the concentric annuli in various range of Reynolds number. The pressure drops in the core tubes and the annuli were much higher than those in the tubes with smooth surface. Therefore, modified correlations to present the experimental results in each flow passage were suggested.

Study for surface wave launcher of dielectric coated coaxial cable using FDTD method (FDTD 방법을 이용한 유전체를 입힌 동축 케이블의 표면파 로운처에 관한 연구)

  • 정진우;이창원김중표손현
    • Proceedings of the IEEK Conference
    • /
    • 1998.06a
    • /
    • pp.173-176
    • /
    • 1998
  • The surface wave launcher from the dielectric coated coaxial cable to dielectric slab is investigated. FDTD method using local subcell and contour-path model is applied to determine the fine geometrical features. The reflection coefficient in coaxial cable region is found using extract algorithm. In this paper, two structures are presented as coaxial slot surface wave launcher. One structure has a vertical launching angle, and the other has an arbitrary launching angle. The numerical results show that a certain launching angle is minimized the reflection coefficient.

  • PDF

Sheath Circulating Current Analysis of a Crossbonded Power Cable Systems

  • Jung, Chae-Kyun;Lee, Jong-Beom;Kang, Ji-Won
    • Journal of Electrical Engineering and Technology
    • /
    • v.2 no.3
    • /
    • pp.320-328
    • /
    • 2007
  • The sheath in underground power cables serves as a layer to prevent moisture ingress into the insulation layer and provide a path for earth return current. Nowadays, owing to the maturity of manufacturing technologies, there are normally no problems for the quality of the sheath itself. However, after the cable is laid in the cable tunnel and is operating as part of the transmission network, due to network construction and some unexpected factors, some problems may be caused to the sheath. One of them is the high sheath circulating current. In a power cable system, the uniform configuration of the cables between sections is sometimes difficult to achieve because of the geometrical limitation. This will cause the increase of sheath circulating current, which results in the increase of sheath loss and the decrease of permissible current. This paper will study the various characteristics and effects of sheath circulating current, and then will prove why the sheath current rises on the underground power cable system. A newly designed device known as the Power Cable Current Analyser, as well as ATP simulation and calculation equation are used for this analysis.