• Title/Summary/Keyword: Cable angle

Search Result 104, Processing Time 0.026 seconds

An Estimating Mehod of the Angle of Attack of a Vertical V-type Otter Board (종만곡 V형 전개판의 영각 추정법)

  • Park, Hae-Hoon
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.41 no.2
    • /
    • pp.113-121
    • /
    • 2005
  • How to extimate the angle of attack of a vertical V-type cambered otter board was described. A three-dimensional semi-analytic treatment of a towing cable system was applied to the field experiments of a midwater trawl obtained by the Scanmar system. Also the equilibrium condition of the horizontal component and vertical component of forces and moment around the otter board was used. When the warp length was 300m long and the towing speed was between 2.61 and 3.86 knots, the estimated angle of attack of the otter board was ranged between $24.7^{\circ}$ and $26.2^{\circ}$, though the maximum lift force was at the angle of attack $22^{\circ}$.

A Study on the Analysis of Induced Voltage of Sheath on 154kV Transmission Power Cable in Multi Fault Cases (다양한 고장조건에서 154kV 지중송전케이블 시스유기전압해석에 관한 연구)

  • Lee, Jun-Sung;Lee, Jong-Beom
    • Proceedings of the KIEE Conference
    • /
    • 1998.07c
    • /
    • pp.1179-1181
    • /
    • 1998
  • This paper describes the induced voltage of sheath on 154kV transmission power cable in multi fault states. Simulation was carried out to obtain the induced voltage of sheath according to change of, fault angle and grounding resistance using EMTP. Modeling of cable system is also established in EMTP to analyze. The simulation results can be useful reference to design cable system in power system.

  • PDF

A Study on the Partial Discharge Phase Properties with Branch Type Eleotrical Tree Growth in XLPE Cable Insulation (XLPE 케이블 절연체에서의 가지형 전기트리 성장에 따른 부분방전 위상 특성 연구)

  • Gang, Dong-Sik;Seon, Jong-Ho;Kim, Wi-Yeong;Lee, Hong-Sik;Park, Jeong-Hu
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.51 no.5
    • /
    • pp.213-221
    • /
    • 2002
  • In order to improve the reliability of XLPE cables, it is necessary to find the useful diagnostic parameter according to long term aging. This paper described the change of partial discharge(PD) phase Properties of XLPE cable insulation with branch type electrical tree degradation. for long term aging. To understand the PD Properties with $\phi$ -q-n distributed shape of XLPE insulation, specimens were prepared by 22.9㎸ distribution cable and made in a type of block(16${\times}$16${\times}$3[mm]). Ogura needles having tip radius of l0${\mu}{\textrm}{m}$ were inserted into each block pieces. The measuring system was consisted of PD detector, digitizer for digital conversion, VXI system for signal processing. The PD properties of the specimens were measured from initiation of tree to breakdown and their characteristics were analyzed. We analyzed the relationship between electrical properties(PD Quantity, PD initiation angle, PD extinction angle, PD occurrence angle : (PD extinction angle - PD initiation angle)) and the normalized aging rate. We found PD parameter, PD initiation angle and occurrence angle, which are a useful diagnostic parameter in estimating the branch type electrical tree for XLPE insulation condition.

Study of the non-linearity of cable damper to enhance damping performance of stay cable (사장교 케이블의 감쇠성능 향상을 위한 댐퍼의 비선형성 연구)

  • Seo, Ju-Won;Koh, Hyun-Moo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.05a
    • /
    • pp.147-156
    • /
    • 2007
  • This study offers a design procedure of optimum cable damper for multi-mode vibration control with nonlinear damper and also investigate the relation between mode and amplitude dependency. The proposed multi-mode damping index, which is defined as a energy loss ratio of cable potential, is a main component of optimization problem of optimum nonlinear damper. In order to include the amplitude dependency of nonlinear damper, it is assumed to exist three kinds of multi-mode patterns such as ambient vibration, support excitation and rain-win induced vibration. The optimum damper exponent depends on amplitude patterns. In case of ambient vibration, optimum factor is less than 0.5. In case of support excitation or rain-wind induced vibration is between 0.5 and 1.0. In this study, the effects of cable sag and inclination angle are included in the asymptotic design equation of damped cable structures.

  • PDF

Analysis of dry friction hysteresis in a cable under uniform bending

  • Huang, Xiaolun;Vinogradov, Oleg
    • Structural Engineering and Mechanics
    • /
    • v.2 no.1
    • /
    • pp.63-80
    • /
    • 1994
  • A cable is considered as a system of helical wires and a core with distributed dry friction forces at their interfaces. Deformations of the cable subjected to a uniform bending are analyzed. It is shown that there is a critical bending curvature when a slip at the wire-core interface occurs. It originates at the neutral axis of the cross section of the cable and then spreads symmetrically over the cross section with the increase of bending. The effect of slippage on the cable stiffness is investigated. This model is also used to analyze a cable under the quasi-static cyclic bending. Explicit expression for the hysteretic losses per cycle of bending is derived. Numerical examples are given to show the influence of dry friction and helix angle on the bending stiffness and hysteretic losses in the cable.

Critical Current and AC loss Characteristics with Pitch of HTS tape (HTS tape의 Pitch에 따른 임계전류 및 교류손실 특성)

  • Kim, Hae-Joon;Sim, Ki-Deok;Kim, Jae-Ho;Kim, Seok-Ho;Cho, Jeon-Wook
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2006.06a
    • /
    • pp.265-266
    • /
    • 2006
  • Superconductor is developed for applications in high-power devices such as power-transmission cables, transformers, motor and generators. In such applications, HTS tapes are subjected to various kinds of stress or strain. In the fabrication of the devices, the critical current (Ic) of the high temperature superconductor degrades due to many reasons including the tension applied by bending, twist and thermal contraction. In particular manufactured HTS cable, we need pitch angle controls. This paper is analyzed that Ic characteristics is changed pitch angle of HTS tape. These results will amount the most important basis data in HTS cable.

  • PDF

Analysis of Sheath Induced Voltage in Transmission Power Cable Connected with CCPU (방식층 보호장치의 설치에 따른 지중송전케이블 시스 유기전압 해석)

  • Lee, Jun-Sung;Lee, Jong-Beom;Kim ,Young
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.49 no.1
    • /
    • pp.19-25
    • /
    • 2000
  • This paper describes the sheath induced voltage in underground transmission cable system which will be operated with cable cover protection unit(CCPU). Simulation was carried out to analyze the sheath induced voltage in the real cable system which was installed by 154㎸ CV cable in the case with and without CCPU. The sheath induced voltage will be also analyzed according to the change of grounding method, fault resistance and fault angle. Simulation was performed using EMTP and ATP Draw, the simulation results show whether the CCPU in necessary or not in underground transmission power cable system.

  • PDF

Development of innovative superconducting DC power cable

  • Matsushita, Teruo;Kiuchi, Masaru
    • Progress in Superconductivity and Cryogenics
    • /
    • v.19 no.3
    • /
    • pp.1-7
    • /
    • 2017
  • It is required to reduce the cost of superconducting cable to realize a superconducting DC power network that covers a wide area in order to utilize renewable energy. In this paper a new concept of innovative cable is introduced that can enhance the current-carrying capacity even though the same superconducting tape is used. Such a cable can be realized by designing an optimal winding structure in such a way that the angle between the tape and magnetic field becomes small. This idea was confirmed by preliminary experiments for a single layer model cable made of Bi-2223 tapes and REBCO coated conductors. Experiments of three and four layer cables of practical sizes were also done and it was found that the current-carrying capacity increased as theoretically predicted. If the critical current properties of commercial superconducting tapes are further improved in a parallel magnetic field, the enhancement will become pronounced and this technology will surely contribute to realization of superconducting DC power network.

Wind-induced aerostatic instability of cable-supported bridges by a two-stage geometric nonlinear analysis

  • Yang, Y.B.;Tsay, Jiunn-Yin
    • Interaction and multiscale mechanics
    • /
    • v.1 no.3
    • /
    • pp.381-396
    • /
    • 2008
  • The aerostatic instability of cable-supported bridges is studied, with emphasis placed on modeling of the geometric nonlinear effects of various components of cable-supported bridges. Two-node catenary cable elements, which are more rational than truss elements, are adopted for simulating cables with large or small sags. Aerostatic loads are expressed in terms of the mean drag, lift and pitching moment coefficients. The geometric nonlinear analysis is performed with the dead loads and wind loads applied in two stages. The critical wind velocity for aerostatic instability is obtained as the condition when the pitching angle of the bridge deck becomes unbounded. Unlike those existing in the literature, each intermediate step of the incremental-iterative procedure is clearly given and interpreted. As such, the solutions obtained for the bridges are believed to be more rational than existing ones. Comparisons and discussions are given for the examples studied.

Analysis of Induced Voltage on Sheath of Transmission Power Cable Connected with Surge Arrester (피뢰기 적용에 따른 지중송전케이블 시스 유기전압 해석)

  • Lee, Jun-Sung;Lee, Jong-Beom;Kim, Young
    • Proceedings of the KIEE Conference
    • /
    • 1999.07c
    • /
    • pp.1391-1393
    • /
    • 1999
  • This paper have analyzed sheath induced voltage in underground transmission cable system which will be operated with cable cover protection unit(CCPU). Simulation was carried out to analyze sheath induced voltage using on real cable system in the case with and without CCPU. Sheath induced voltage was also analyzed according to grounding method, fault resistance and fault angle. Simulation was performed using EMTP and ATP Draw, the simulation results represent whether the arrester is necessary or not in cable system.

  • PDF