• 제목/요약/키워드: Cable Tension

검색결과 301건 처리시간 0.032초

구조시스템에 따른 케이블 돔의 정적 불안정거동 특성에 관한 연구 (A Study of Static Unstable Behavioral Characteristics of Cable Dome Structures according to the Structural System)

  • 조인기;김형석;김승덕;강문명
    • 한국공간정보시스템학회:학술대회논문집
    • /
    • 한국공간정보시스템학회 2004년도 춘계 학술발표회 논문집 제1권1호(통권1호)
    • /
    • pp.131-138
    • /
    • 2004
  • The cable structure is a kind of ductile structural system using the tension cable and compression column as a main element. From mechanical characteristics of the structural material, it is profitable to be subjected to the axial forces than bending moment or shear forces. And we haweto consider the local buckling when it is subjected to compression forces, but tension member can be used until the failure strength. So we can say that the tension member is the most excellent structural member. Cable dome structures are made up of only the tension cable and compression column considering these mechanical efficiency and a kind of structural system. In this system, the compression members are connected by using tension members, not connected directly each other. Also, this system is lightweight and easy to construct. But, the cable dome structural system has a danger of global buckling as external load increases. That is, as the axisymmetric structure is subjected to the axisymmetric load, the unsymmetric deformation mode is happened at some critical point and the capacity of the structure is rapidly lowered by this reason. This phenomenon Is the bifurcation and we have to reflect this in the design process of the large space structures. In this study, We investigated the nonlinear unstable phenomenon of the Geiger, Zetlin and Flower-type cable dome.

  • PDF

송전용 고분자 애자의 정적 및 동적인 상태에서 장기 기계적 특성 연구 (A Study on the Long-term Mechanical Properties Under Static and Cyclic State of Composite Insulators for Transmission Lines)

  • 김수연;김영성;홍진영;박완기
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 추계학술대회 논문집 학회본부 C
    • /
    • pp.869-871
    • /
    • 1998
  • The extensive use of composite insulators for transmission lines can ultimately be justified only on long-term qualification tests. The actual load working on the insulator in the field is not static load but cyclic load. So in this paper, we discussed an examination of aging degradation by mechanical performance of composite insulators under static tension load and cyclic tension load. and also described useful approaches for analyzing their long term performance so as to develop reliable composite insulators. The static and cyclic tension load-time test data were examined by Weibull distribution for their capability of presuming long term performance. It was found that cyclic tension loads were more severe than static tension loads. The results also indicate that it may be relevant for an user to select composite insulators on basis of their performance under cyclic tension loads than static tension loads.

  • PDF

재긴장과 무선 모니터링이 가능한 유압식 케이블 접합부시스템의 실험에 대한 연구 (Experimental study of Hydraulic Cable Connection Systems with Re-tensioning and Wireless Monitoring)

  • 김민수;이기학;김성범;이성민;백기열
    • 한국공간구조학회논문집
    • /
    • 제11권2호
    • /
    • pp.71-79
    • /
    • 2011
  • 케이블 구조시스템의 경우 자기 평형 상태를 유지하기 때문에 장력이 손실된 특정 케이블을 재긴장을 하지 않으면 구조엔지니어가 요구한 하중보다 더 큰 하중이 다른 케이블에 전달되어 손상을 야기 할 수 있다. 또한, 턴버클을 이용한 재긴장 방법이 기존에 널리 적용되고 있지만 정확한 장력조절과 대구경 케이블에는 적절하지 못하고 인장재의 하중의 크기를 측정하는 것이 어렵다. 따라서 효과적으로 재긴장 할 수 있는 유압식 볼팅 접합부를 개발하고 인장력을 실시간으로 확인할 수 있는 모니터링 시스템을 적용하였다. 본 논문에서는 개발된 시스템의 현장 적용성 실험과 결과를 제시하였다.

A multi-functional cable-damper system for vibration mitigation, tension estimation and energy harvesting

  • Jung, Hyung-Jo;Kim, In-Ho;Koo, Jeong-Hoi
    • Smart Structures and Systems
    • /
    • 제7권5호
    • /
    • pp.379-392
    • /
    • 2011
  • This paper presents a multi-functional system, consisting of a magnetorheological (MR) damper and an electromagnetic induction (EMI) device, and its applications in stay cables. The proposed system is capable of offering multiple functions: (1) mitigating excessive vibrations of cables, (2) estimating cable tension, and (3) harvesting energy for wireless sensors used health monitoring of cable-stayed bridges. In the proposed system, the EMI device, consisting of permanent magnets and a solenoid coil, can converts vibration energy into electrical energy (i.e., induced emf); hence, it acts as an energy harvesting system. Moreover, the cable tension can be estimated by using the emf signals obtained from the EMI device. In addition, the MR damper, whose damping property is controlled by the harvested energy from the EMI device, can effectively reduce excessive cable vibrations. In this study, the multi-functionality of the proposed system is experimentally evaluated by conducting a shaking table test as well as a full-scale stay cable in a laboratory setting. In the shaking table experiment, the energy harvesting capability of the EMI device for wireless sensor nodes is investigated. The performance on the cable tension estimation and the vibration mitigation are evaluated using the full-scale cable test setup. The test results show that the proposed system can sufficiently generate and store the electricity for operating a wireless sensor node twice per day, significantly alleviate vibration of a stay cable (by providing about 20% larger damping compared to the passive optimal case), and estimate the cable tension accurately within a 2.5% error.

스내핑 케이블의 극단장력의 해석기법 개발 -매개변수 연구- (The Development of Analysis Techniques of Extreme Tensions in a Snapping Cable - Parameter Studies -)

  • 신현경
    • 대한조선학회논문집
    • /
    • 제29권4호
    • /
    • pp.146-151
    • /
    • 1992
  • 이 논문에서는 스내핑 케이블(Snapping Cable)의 극단 인장력(Extreme Tension)이 연구되어지고 해석기법으로 클리핑-오프 모델(Clipping-off Model)을 이용하여 매개변수 연구(Parameter Study)가 수행되었다. 이 매개변수 연구에 의한 주어진 케이블의 초기 클리핑 발생 주파수 예측은 거친 해상에서 큰 동인장력(Large Dynamic Tension)이 발생되어 전체인장력(Total tension) 이 음의 값이 되는 스내핑현상이 일어날 수 있는 케이블의 동적 거동을 예견하기 위한 유용한 지침으로서 사용될 수 있을 것이다.

  • PDF

비대칭 장력 모델을 이용한 예인 물체의 유체-구조 상호작용 모사 (SIMULATION OF FLUID-STRUCTURE INTERACTION OF A TOWED BODY USING AN ASYMMETRIC TENSION MODEL)

  • 신상묵
    • 한국전산유체공학회지
    • /
    • 제16권1호
    • /
    • pp.7-13
    • /
    • 2011
  • The fluid-structure interaction of a towed body is simulated using a developed code, which is based on the flux-difference splitting scheme on the hybrid Cartesian/immersed boundary method. To improve the stability in the coupling between the fluid and structure domains, a scheme is used, in which the effects of structure deformation are treated implicitly. The developed code is validated for the fluid-structure interaction problem through comparisons with other results on the vortex-induced vibration of elastically mounted cylinders. To simulate behavior of a towed body, an asymmetric tension modelling for a towing cable is suggested. In the suggested model, the tension is proportional to the elongation of the cable, but the cable has no effect on the body motion whenever the distance between the endpoints of the cable is smaller than the original length of the cable. The fluid-structure interactions of a towed body are simulated on the basis of different parameters of the towing cables. It is observed that the suggested tension model predicts the snapping for a shorter towing cable, which is in accordance with the reported results.

A Numerical and Experimental Study on Dynamics of A Towed Low-Tension Cable

  • 정동호;박한일
    • 한국해양공학회:학술대회논문집
    • /
    • 한국해양공학회 2002년도 추계학술대회 논문집
    • /
    • pp.191-196
    • /
    • 2002
  • The paper presents a numerical and experimental investigation on dynamic behaviors of a towed low tension cable. In the numerical study, an implicit finite difference algorithm is employed for three-dimensional cable equations. Fluid and geometric non-linearity and bending stiffness are considered and solved by Newton-Raphson iteration. Block tri-diagonal matrix method is applied for the fast calculation of the huge size of matrices. In order to verify the numerical results and to see real physical phenomena, an experiment is carried out for a 6m cable in a deep and long towing tank. The cable is towed in two different ways; one is towed at a constant speed and the other is towed at a constant speed with top end horizontal oscillations. Cable tension and shear forces are measured at the top end. Numerical and experimental results are compared with good agreements in most cases but with some differences in a few cases. The differences are due to drag coefficients caused by vortex shedding. In the numerical modeling, non-uniform element length needs to be employed to cope with the sharp variation of tension and shear forces at near top end.

  • PDF

Experimental study on the cable rigidness and static behaviors of AERORail structure

  • Li, Fangyuan;Wu, Peifeng;Liu, Dongjie
    • Steel and Composite Structures
    • /
    • 제12권5호
    • /
    • pp.427-444
    • /
    • 2012
  • This paper presented a new aerial platform-AERORail for rail transport and its structure evolution based on the elastic stiffness of cable; through the analysis on the cable properties when the cable supported a small service load with high-tensile force, summarized the theoretical basis of the AERORail structure and the corresponding simplified analysis model. There were 60 groups of experiments for a single naked cable model under different tensile forces and different services loads, and 48 groups of experiments for the cable with rail combined structure model. The experimental results of deflection characteristics were compared with the theoretical values for these two types of structures under the same conditions. It proved that the results almost met the classical cable theory. The reason is that a small deflection was required when this structure was applied. After the tension increments tests with moving load, it is verified that the relationships between the structure stiffness and tension force and service load are simple. Before further research and applications are made, these results are necessary for the determination of the reasonable and economic tensile force, allowable service load for the special span length for this new platform.

Effects of tensioning forces on the structural behavior of cable-stayed bridges

  • Lam, Pauline Lin Li;Kang, Thomas H.K.
    • Steel and Composite Structures
    • /
    • 제43권4호
    • /
    • pp.457-464
    • /
    • 2022
  • Optimization in distribution of stay cable forces is one of the most difficult aspects in the design of cable-stayed bridges. This article attempts to examine tension force influence on structural behavior of cable-stayed bridges. For the examination, finite element modeling using nonlinear static and nonlinear modal analyses was completed and compared to structural experimental results. Variables analyzed in this parametric study were: 1) Number of stay cables; 2) Tension of the stay cables, and 3) Stay cable pattern - harp and semi-fan patterns. Though the findings from the analysis are limited to the tested models, the study gives insight on the structural behavior of actual cable stayed bridges.

역해석기법을 이용한 현수교 행어케이블 장력 추정 (Back Analysis for Estimating Tension Force on Hanger Cables)

  • 김남식;빈정민;장성진
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2006년도 춘계학술대회논문집
    • /
    • pp.894-901
    • /
    • 2006
  • In general, the tension fores of hanger cable in suspension bridges play an important role in evaluating the bridge state. The vibration method, as a conventional one, has been widely applied to estimate the tension fores by using the measured frequencies on hanger cables. However, the vibration method is not applicable to short hanger cables because the frequency of short cables is severely sensitive to the flexural rigidity. Thus, in this study, the tension forces of short hanger cables, of which the length is shorter than 10meters, were estimated through back analysis of the cable frequencies measured from Gwang-An suspension bridge in Korea. Direct approach to rock analysis is adopted using the univariate method among the direct search methods as an optimization technique. The univariate method is able to search the optimal tension forces without regard to the initial ones and has a rapid convergence rate. To verify the feasibility of back analysis, the results from back analysis and vibration method are compared with the design tension forces. From the comparison, it can be inferred that back analysis results are more reasonable agreement with the design tension forces of short hanger cable. Therefore, it is concluded that back analysis applied in this study is an appropriate tool for estimating tension forces of short hanger cables.

  • PDF