Partial Discharge Distribution Characteristics along Defect of CNC Cable (배전급 CNC케이블의 결함 종류에 따른 부분방전 분포특성)

  • Yoon, Jae-Hun;Kang, Seung-Hwa;Choi, Han-Sick;Lim, Gee-Jo
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2010.06a
    • /
    • pp.102-102
    • /
    • 2010
  • A purpose of this paper is to recognize partial discharge pattern for cable insulation. The classification of PD sources was widely studied for two decades. this research sought to use the partial discharge detection method, and to diagnose the interface of cable, which is deemed vulnerable of cable systems. A research abalyzed faults that can occur in the interface of cable joint as well as accident mechanisms, manufactured test 22.9kV CNC cable, invented artificial faults and carried out partial discharge detection experiments. As a result, various PD pattern along defect measured and distinguished.

  • PDF

Stabilities of cable-stiffened cylindrical single-layer latticed shells

  • Li, Pengcheng;Wu, Minger
    • Steel and Composite Structures
    • /
    • v.24 no.5
    • /
    • pp.591-602
    • /
    • 2017
  • A cable-stiffened cylindrical single-layer latticed shell that is reinforced by cable-stiffened system has superior stability behaviour compared with the ordinary cylindrical latticed shell. The layouts of cable-stiffened system are flexible in this structural system, and different layouts contribute different stiffness to the structure. However, the existed few research primarily focused on the simplest type of cable layouts, in which the grids of the latticed shell are diagonally stiffened by prestressed cables in-plane. This current work examines the stability behaviour of the cable-stiffened cylindrical latticed shells with two different types of cable layouts using nonlinear finite element analysis. A parametric study on the effect of cross-sectional of the cables, pretension in cables, joint stiffness, initial imperfections, load distributions and boundary conditions is presented. The findings are useful for the reference of the designer in using this type of structural system.

Determination of Member Force Ratios for Self-equilibrium State of Multi-Layered Cable Dome Type Structures (다층 케이블 돔형 구조물의 자기평형을 위한 부재력 비율 결정)

  • Kim, Jae-Yeol
    • Journal of Korean Association for Spatial Structures
    • /
    • v.13 no.2
    • /
    • pp.75-82
    • /
    • 2013
  • For each cable component in a cable dome structure, pre-tension is needed for stability of whole the structure. The summation of these pre-tension at each joint should be zero to achieve the self equilibrium structure. The first step in cable dome structure analysis is to find the ratio of pre-tension in each member which can produce a stable and structure on self-equilibrium. In this paper, a new method based on the basic principle of closed force polygon for equilibrium system is proposed for the determination of self-equilibrium mode of cable dome structure. A single layer cable dome and two multi layer type domes have been analyzed. The ratios of cable members are determined by the presented method, and check the validation of the results by numerical calculation.

A Study on Energy Characteristics in Transient States of OF Cable Systems (OF 케이블 계통에서 과도상태시 에너지 특성 검토)

  • Jung, Chae-Kyun;Lee, Jong-Beom;Kang, Ji-Won;Lee, Dong-Il;Seo, Je-Ho
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.55 no.11
    • /
    • pp.468-475
    • /
    • 2006
  • This paper reviews the energy characteristics of oil filled cables in transient state such as grounding fault and lightning surge. Artificial grounding fault test was firstly performed in 2003 for the analysis of arc voltage and breakdown energy according to the fault current. In this paper, energy of OF cable is variously analysed at joint box based on the actual test. Then more various conditions such as installation types, section lengths and CCPU(Cable Covering Protection Unit) connection types are applied for the simulation using EMTP when the single line to ground fault and direct lightning stroke are occurred on actual underground power cable systems and combined power cable systems, respectively. Finally, the energy by the length of crossbonded lead and grounding lead as well as fault lasting time is also calculated using EMTP simulation.

A Novel Numerical Method for Considering Friction During Pre-stressing Construction of Cable-Supported Structures

  • Zhao, Zhongwei;Liang, Bing;Yan, Renzhang
    • International journal of steel structures
    • /
    • v.18 no.5
    • /
    • pp.1699-1709
    • /
    • 2018
  • Suspen-dome structures are extensively used due to their superiority over traditional structures. The friction between cable and joints may severely influence the distribution of cable force, especially during the pre-stressing construction period. An accurate and efficient numerical method has not yet been developed that can be used for estimating the influence of friction on cable force distribution. Thus, this study proposes an efficient friction element to simulate friction between cable and joint. A flowchart for estimating the value of friction force is introduced. These novel numerical methods were adopted to estimate the influence of friction on cable force distribution. The accuracy and efficiency of these numerical methods were validated through numerical tests.

The Experimental Verification and Fault Cause Analysis of Breakdown on the 6.6kV class Cable Joint (6.6kV급 케이블 중간접속부의 절연파괴 사고원인 분석과 실험 검증)

  • Kim, Young-Seok;Shong, Kil-Mok;Jung, Jin-Su
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.1385_1386
    • /
    • 2009
  • In this paper, we examined the faulted cable joint through the external form analysis, material analysis, experimental verification and it's cause diagnosis system. It was not observed the voild, sharp material from the external form analysis and material variation. From the experimental verification, the thickness decrease of an insulator decreased ac breakdown strength suddenly and the breakdown traces of the insulator that was damaged by knife displayed elliptic shape. Thus, the faulted cable is assumed to accident that become dielectric breakdown by the deterioration of insulation performance that can happen when work.

  • PDF

A study on the analysis and simulation of interfacial breakdown properties with interfacial condition in Epoxy/EPDM (Epoxy/EPDM 이종절연물의 계면조건에 따른 계면절연파괴특성의 분석 및 시뮬레이션에 관한 연구)

  • 정인재;박성민;김영식;김상걸;장인범;김용주;이준응
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1998.11a
    • /
    • pp.227-230
    • /
    • 1998
  • The interfacial breakdown between two internal dielectric surfaces represents one of the major causes of failure for power cable joint. In order to better understand this phenomenon, breakdown experiments were performed for each interfacial condition at Epoxt/EPDM interface found in cable. The specimen were Epoxy resin and EPDM generally used in cable joint. The interface conditions were three parts. First condition was the pressure of interface, we used the value of 1, 2, 3, 4, 5[kg/cm$^2$]. For the second condition, the sanding condition was treated with sand paper #220, #600, #1200. Finally, we observed the breakdown according to the presence of silicon oil at the interface.

  • PDF

A Study on the Insulation Design of Normal Joint in 345kV Oil-Filled Cable (345kV OF 케이블 보통접속재의 절연설계에 관한 연구)

  • Lee, Jung-Bum;Kang, Dong-Sik;Kang, Do-Hyun;Lee, Soo-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 1990.07a
    • /
    • pp.308-311
    • /
    • 1990
  • This paper presents the insulation design of 345kV OF cable normal joint which is essential to construction of underground transmission system. The insulation designs of stress relief cone, pencilling and sleeve were proposed in this paper, and the final insulation design was decided by the results of the electric field and thermal analysis using FEM. It is shown that the designed normal using proves the effect when the developing test is carried out to construct 345kV OF cable if the domestic underground transmission system.

  • PDF

Recent Issues in Musculoskeletal Anatomy Research and Correlation with MRI (근골격 해부학의 최신 지견 및 자기공명영상 소견)

  • Hyerim Park; Joon-Yong Jung
    • Journal of the Korean Society of Radiology
    • /
    • v.81 no.1
    • /
    • pp.2-20
    • /
    • 2020
  • MRI is a valuable imaging technique for the evaluation of intraarticular diseases. Accurate interpretation of joint MRI necessitates sound knowledge of anatomy. In the field of joint anatomy, in addition to the discovery of new structures, previously reported joint components of unexplained function are also detected. In this review, joint anatomy researched actively over the last decade is discussed. Joint components including the rotator cable and the superior capsule of the shoulder, posterolateral corner and the anterolateral ligament complex of the knee, and the distal tibiofibular syndesmosis of the ankle joint are introduced and correlated with their MRI features.

Structural Analysis of a Cable Anchor System for a Cable-Stayed Bridge over the Sea (해상 사장교의 Pipe형 케이블 정착구에 관한 구조해석)

  • KONG BYUNG-SEUNC;HONG NAMSEEG
    • Journal of Ocean Engineering and Technology
    • /
    • v.19 no.5 s.66
    • /
    • pp.34-42
    • /
    • 2005
  • The cable connection zone of the cable-stayed bridge transfers deal-load, live-load, and second-load to the cables on the structural joint zone of the cables and the main girders are the most critical parts in which big cable tensile forces are generated by those loads. Therefore, it is necessary to thoroughly check the main girder, structurally to secure the required stability. Because of the heavy tensile force of cables linked in the connection zone of the cable-stayed bridge, locally concentrated stress, as well as the dispersion of stress, occurs in the structurally contacted point of cable and main girder thus, we need to make a thorough investigation through a detailed structural analysis. Directly delivering the tensile force to the connection zone of the cable, the consequently big effect in the tensile force fluctuation caused by the live-load will make it necessary to review the fatigue strength. As the connection zone of the cable is designed to resist the tensile force of the cable, which is applied to a connecting section as a concentrated force, thick plates are used. These plates are frequently made of welded structure, thus, the investigation of the welding workability is inevitable.