• 제목/요약/키워드: Cable Joint

검색결과 198건 처리시간 0.027초

XLPE/EPOM 계면의 전기적 특성 (Electrical Characteristics on the Interface between XLPE/EPDM)

  • 한성구;조정형;이창종;김종석;서광석;박대희;한상옥
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1996년도 춘계학술대회 논문집
    • /
    • pp.235-238
    • /
    • 1996
  • In this paper, We intended to evaluate the characteristics of XLPE/EPDM interface which exists in the cable joint. The fault was mainly occurred in this interface. Thus we looked into the electrical characteristics through the conduction current and the breakdown test. Through from the experiment, we obtained the result that the conduction current in this interface flowed less than other dielectric materials, that the breakdown strength was higher and that the pressure dependance ㅐf the breakdown strength was higher.

  • PDF

XLPE/EPDM의 계면처리조건에 따른 절연파괴 특성 (Breakdown Characteritics of XLPE/EPDM on the Treatment Condition of the Interfacial layer)

  • 한성구;조정형;이창종;박양범;박강식;한상옥
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1996년도 추계학술대회 논문집
    • /
    • pp.230-233
    • /
    • 1996
  • In this paper, We intended to evaluate characteristics of XLPE/EPDM interface which exists in the cable joint. Because the fault was mainly occurred in this interface. We investigated breakdown characteristics of XLPE/EPDM double layered insulator as a funtion of temperature, pressure, annealing time, kinds of jointmaterial. It was shown that breakdown strength of XLPE/EPDM insulators is higher that of XLPE/XLPE or EPDM/EPDM

  • PDF

지중송전계통에서 보통접속함의 접지방식에 따른 고장전류분류율 재검토 (Restudy of Fault Current Distribution Ratio with Grounding Type of Normal Joint Box in Underground Transmission Systems)

  • 홍동석;강지원;장태인;김형호;윤형희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 A
    • /
    • pp.500-502
    • /
    • 2002
  • Receltly, Underground transmission system is getting increased. Therefore the design of grounding system becomes very important to discharge overcurrent of lightning and fault through earth and reduce sheath induced voltage and sheath circulation current. This paper describes fault current distribution ratio for grounding line with grounding types of normal joint box and sheath grounding resistor at line-to-ground fault of cable.

  • PDF

작은 그루브 각을 가지는 맞대기 P-GMA 용접에서의 용접아크에 관한 연구 (A Study on the Arc Characteristics in Butt Joint P-GMA Welding with Acute Groove Angles)

  • 김륜한;나석주;김철희
    • 대한용접접합학회:학술대회논문집
    • /
    • 대한용접접합학회 2010년도 춘계학술발표대회 초록집
    • /
    • pp.53-53
    • /
    • 2010
  • The purpose of this paper is to propose a mathematical model of welding current for the P-GMAW by modifying the well known GMAW model. Welding power circuit is simply modeled as a RL electric circuit and solved as an ODE equation. The welding current depends on the joint shape, molten pool and welding parameters. To compare the molten pool effect to the welding current, CFD numerical simulation technique was adopted. Welding experiment is also conducted with the same welding parameters as used in numerical simulations to verify the proposed welding current model. The current model which is considered molten pool shape, is more fit to experiment result.

  • PDF

작은 그루브 각을 가지는 맞대기 P-GMA 용접에서의 용접전류에 관한 연구 (A Study on the Welding Current in Butt Joint P-GMA Welding with Acute Groove Angles)

  • 김륜한;나석주;김철희
    • Journal of Welding and Joining
    • /
    • 제28권4호
    • /
    • pp.55-60
    • /
    • 2010
  • The purpose of this paper is to propose a mathematical model of welding current for the P-GMAW by modifying the well known GMAW model. Welding power circuit is simply modeled as a RL electric circuit and solved as an ODE equation. The welding current depends on the joint shape, molten pool and welding parameters. To compare the molten pool effect to the welding current, CFD numerical simulation technique was adopted. Welding experiment is also conducted with the same welding parameters as used in numerical simulations to verify the proposed welding current model. The current model which is considered molten pool shape, is more fit to experiment result.

230kV XLPE 삽입형 고무몰드 접속함의 개발 (Development of Pre-molded Joint for 230kV XLPE Power Cable)

  • 김화종;김현주;김성용;송재혁;한지훈;이호림;김덕환
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 C
    • /
    • pp.1564-1565
    • /
    • 2006
  • 현재 전세계적으로 170kV급 이하의 초고압 지중케이블 접속함으로 기존의 현장몰드방식의 TMJ(Tape Molded Joint)와 부품조립방식의 PJ(Prefabricated Joint)보다 조립시간이 짧고 작업자의 숙련도가 높지 않아 경제적이며, 유지보수에 장점을 가진 고무몰드 접속함(PMJ)이 채용되고 있으며, 이러한 추세는 적용 전압급이 점차 상승하면서 230kV급까지 그 비중이 늘어나고 있는 경향을 보이고 있다. 당사에서는 이러한 추세에 발맞추어 154kV급 고무몰드접속함의 개발 당시의 Silicone의 기초물성시험 DATA 획득, 고무몰드 UNIT 및 금형 설계 기술 확립과 접속 공법 개발의 경험을 바탕으로 230kV급 고무몰드접속함의 개발에 성공하였다.

  • PDF

Static analysis of a radially retractable hybrid grid shell in the closed position

  • Cai, Jianguo;Jiang, Chao;Deng, Xiaowei;Feng, Jian;Xu, Yixiang
    • Steel and Composite Structures
    • /
    • 제18권6호
    • /
    • pp.1391-1404
    • /
    • 2015
  • A radially retractable roof structure based on the concept of the hybrid grid shell is proposed in this paper. The single-layer steel trusses of the radially foldable bar structure are diagonally stiffened by cables, which leads to a single-layer lattice shell with triangular mesh. Then comparison between the static behavior between the retractable hybrid grid shell and the corresponding foldable bar shell with quadrangular mesh is discussed. Moreover, the effects of different structural parameters, such as the rise-to-span ratio, the bar cross section area and the pre-stress of the cables, on the structural behaviors are investigated. The results show that prestressed cables can strengthen the foldable bar shell with quadrangular mesh. Higher structural stiffness is anticipated by introducing cables into the hybrid system. When the rise-span ratio is equal to 0.2, where the joint displacement reaches the minimal value, the structure shape of the hyrbid grid shell approaches the reasonable arch axis. The increase of the section of steel bars contributes a lot to the integrity stiffness of the structure. Increasing cable sections would enhance the structure stiffness, but it contributes little to axial forces in structural members. And the level of cable prestress has slight influence on the joint displacements and member forces.

모듈러 신축이음장치 지진거동 모사 실험적 연구 (Experimental Study on the Seismic Behavior Simulation of Modular Expansion Joint)

  • 이정우;최은석
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제26권5호
    • /
    • pp.43-48
    • /
    • 2022
  • 본 논문에서는 신축량이 크고 내구성이 우수한 모듈러 신축이음장치의 내진성능을 평가하기 위해 지진응답 거동해석과 지진거동모사실험을 수행하였다. 지진응답 거동해석은 한국(KS), 미국(AASHTO LRFD), 그리고 유럽(Eurocode)의 설계기준 응답스팩트럼을 적용하여 인공지진파를 생성하였다. 해석대상 교량은 경간 1,000m 사장교를 대상으로 각 기준에 대해 세가지의 인공지진파를 생성하였으며, 지진거동모사실험은 축방향과 횡방향의 동적 유압가력기를 사용하여 인공지진파를 재현하였다. 실험결과 축방향, 횡방향 및 양방향에 인공지진파를 재하하였을 때 신축이음의 거동 이상이나 파괴는 발생하지 않았으며, 신축이음장치의 지진거동에 대한 내구성 및 안전성을 확인하였다.

가교폴리에틸렌 계면에서의 트리성장 분석 (An Analysis of Tree Growth in the XLPE Interface)

  • 김철운;박현빈;김태성;이준웅
    • 한국전기전자재료학회논문지
    • /
    • 제11권2호
    • /
    • pp.90-94
    • /
    • 1998
  • This study aims at analyzing to treeing in the solid-solid interface which is insulation type of cable junction parts, the proceeding of tree-growth and electrical breakdown were research in the study. Interface was made artificially to detect how it influenced the insulating ability of the whole system, the specimen were XLPE generally used in cable. The interface conditions were divided into two parts. First condition being the one focused on the surface of interface, it was treated with sand paper (#80, #600, #1200). For the second condition, the pressure of interface was varied as the value of 1, 5, 10 [$kg/cm^2$]. Using above conditions, treeing and breakdown properties on tree-growth were respectively compared in details. As a result, breakdown time was shorter for the full range of supplied voltage in the case of interface existed in the joint than non-existed interface. In the case of existed interface, the interface which had high-interface pressure and painted with silicon insulating oil was the best in the aspect of breakdown characteristics.

  • PDF

XLPE/EPDM 계면에서의 절연파괴 특성 (Properties of Electrical Breakdown in the Interface between XLPE / EPDM)

  • 조정형;한성구;이창종;김석기;최용식;박강식;서광석;박대희;한상옥
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 C
    • /
    • pp.1469-1471
    • /
    • 1996
  • In this paper, We intended to evaluate the characteristics of XLPE/EPDM interface which exists in the cable joint. The fault of practical cable was mainly occurred in this interface. Thus we looked into the electrical characteristics through the conduction current and the breakdown test. Through the experiment, we obtained the result that the conduction current in this interface flowed less than other dielectric materials, that the breakdown strength was higher and that the pressure dependance of the breakdown strength was higher.

  • PDF