• 제목/요약/키워드: Cable Force

검색결과 351건 처리시간 0.038초

Response evaluation and vibration control of a transmission tower-line system in mountain areas subjected to cable rupture

  • Chen, Bo;Wu, Jingbo;Ouyang, Yiqin;Yang, Deng
    • Structural Monitoring and Maintenance
    • /
    • 제5권1호
    • /
    • pp.151-171
    • /
    • 2018
  • Transmission tower-line systems are commonly slender and generally possess a small stiffness and low structural damping. They are prone to impulsive excitations induced by cable rupture and may experience strong vibration. Excessive deformation and vibration of a transmission tower-line system subjected to cable rupture may induce a local destruction and even failure event. A little work has yet been carried out to evaluate the performance of transmission tower-line systems in mountain areas subjected to cable rupture. In addition, the control for cable rupture induced vibration of a transmission tower-line system has not been systematically conducted. In this regard, the dynamic response analysis of a transmission tower-line system in mountain areas subjected to cable rupture is conducted. Furthermore, the feasibility of using viscous fluid dampers to suppress the cable rupture-induced vibration is also investigated. The three dimensional (3D) finite element (FE) model of a transmission tower-line system is first established and the mathematical model of a mountain is developed to describe the equivalent scale and configuration of a mountain. The model of a tower-line-mountain system is developed by taking a real transmission tower-line system constructed in China as an example. The mechanical model for the dynamic interaction between the ground and transmission lines is proposed and the mechanical model of a viscous fluid damper is also presented. The equations of motion of the transmission tower-line system subjected to cable rupture without/with viscous fluid dampers are established. The field measurement is carried out to verify the analytical FE model and determine the damping ratios of the example transmission tower-line system. The dynamic analysis of the tower-line system is carried out to investigate structural performance under cable rupture and the validity of the proposed control approach based on viscous fluid dampers is examined. The made observations demonstrate that cable rupture may induce strong structural vibration and the implementation of viscous fluid dampers with optimal parameters can effectively suppress structural responses.

구조용 케이블의 인장력 모니터링을 위한 무선 임피던스 센서노드 기술의 적용성에 관한 연구 (A Study on Applicability of Wireless Impedance Sensor Nodes Technique for Tensile Force Monitoring of Structural Cables)

  • 박재형;홍동수;김정태;나원배;조현만
    • 한국강구조학회 논문집
    • /
    • 제22권1호
    • /
    • pp.21-31
    • /
    • 2010
  • 본 연구에서는 구조 케이블의 인장력 모니터링을 위한 무선 임피던스 센서노드를 개발하였다. 이를 위해 다음과 같은 연구가 수행되었다. 첫째, 경제적이고 자동화된 구조 케이블의 인장력 모니터링을 위한 무선임피던스 센서노드를 설계/제작 하였다. 둘째, 자동화된 인장력 모니터링을 위해 임피던스 기반 모니터링 기법을 무선 센서노드에 내장하였다. 셋째, 측정 범위가 제한적인 무선임피던스 센서노드의 한계점을 극복하기 위하여 인터페이스 와셔를 이용하는 구조케이블 인장력 모니터링 기법을 제안하였다. 마지막으로 내장형/외장형 텐던을 가지는 모형 프리스트레스트 콘크리트 거더에 대하여 무선임피던스 센서노드와 인터페이스 와셔를 이용하는 모니터링 기법의 적용성을 평가하였다.

전자 제어식 주차브레이크 시스템의 제동력 추정 기법 (A Clamping Force Estimation Method in Electric Parking Brake Systems)

  • 장민석;이영옥;이원구;이충우;손영섭;정정주
    • 전기학회논문지
    • /
    • 제57권12호
    • /
    • pp.2291-2299
    • /
    • 2008
  • Hall effect force sensors have been used to measure clamping force in conventional Electric Parking Brake(EPB) systems. Estimation of clamping force without the sensors has drawn attentions due to mounting space limitations and cost issues. Removing the sensor requires the estimation of the initial contact point where the clamping force is effectively applied to the brake pads. In this paper, we propose how to estimate the initial contact point finding the relation between the angular velocity of an actuator and the initial contact point. For force estimation a look-up table is used as a function of the displacement of parking cable from the initial contact point. The proposed method is validated by experiments. From the experimental results we observe that the proposed method satisfies the specifications. The designed method is also able to estimate clamping force although parking cables are loosened and brake pads are worn out. Applying the proposed method enables manufacturing of low cost EPB systems.

Displacement and force control of complex element structures by Matrix Condensation

  • Saeed, Najmadeen M.;Kwan, Alan S.K.
    • Structural Engineering and Mechanics
    • /
    • 제59권6호
    • /
    • pp.973-992
    • /
    • 2016
  • A direct and relatively simple method for controlling nodal displacements and/or internal bar forces has been developed for prestressable structural assemblies including complex elements ("macro-elements", e.g., the pantographic element), involving Matrix Condensation, in which structural matrices being built up from matrices of elementary elements. The method is aimed at static shape control of geometrically sensitive structures. The paper discusses identification of the most effective bars for actuation, without incurring violation in bar forces, and also with objective of minimal number of actuators or minimum actuation. The advantages of the method is that the changes for both force and displacement regimes are within a single formulation. The method can also be used for adjustment of bar forces to either reduce instances of high forces or increase low forces (e.g., in a cable nearing slack).

가상축력을 이용한 좌굴해석 및 HSB800 강재를 적용한 사장교에 대한 적용성 분석 (Buckling Analysis using Fictitious Axial Forces and Its Application to Cable-Stayed Bridges with HSB800 Steel)

  • 최동호;유훈;권순길;임지훈
    • 한국강구조학회 논문집
    • /
    • 제29권1호
    • /
    • pp.13-24
    • /
    • 2017
  • 사장교의 부재별 임계좌굴하중 산정에는 일반적으로 시스템 좌굴해석이 사용된다. 그러나 기존의 시스템 좌굴해석은 압축력이 미소한 부재에 대하여 과도하게 긴 유효좌굴길이를 산정하는 문제점을 내포하고 있다. 본 연구에서는 가상축력을 이용하여 강사장교 부재의 유효좌굴길이를 합리적으로 결정할 수 있는 좌굴해석 방법을 제안하였다. 또한, 수정된 유효접선탄성계수를 이용한 개선된 비탄성 좌굴해석방법을 제시하였다. 제안방법을 예제 사장교 모델에 적용하여 해석결과를 기존의 좌굴해석 방법과 비교 검증하였다. 검증결과, 제안된 방법은 강사장교 거더와 주탑의 유효좌굴길이를 합리적으로 예측할 수 있었다. 그리고 거더와 주탑에 일반강재 대신 HSB800 강재를 적용하였을 경우, 가상축력을 고려하지 않은 제안된 비탄성 좌굴해석에서는 유효좌굴길이가 축력이 작은 부분에서 약간 감소하였으나, 가상축력을 적용한 제안된 비탄성 좌굴해석에서는 유효좌굴길이의 변화가 거의 나타나지 않았다.

S형 보도사장교의 케이블이 횡방향 거동에 미치는 영향 연구 (Study on the effect of cable on the lateral behavior of S-shaped Pedestrian-CSB)

  • 지선근;임성순
    • 한국산학기술학회논문지
    • /
    • 제20권5호
    • /
    • pp.577-584
    • /
    • 2019
  • 최근 국내 사장교는 경관적인 요소를 위하여 비정형적인 형태가 시도되고 있다. 새로운 기하구조가 적용된 사장교는 그 특성을 명확히 분석하여 구조안전성을 확보할 필요가 있다. 본 연구 대상 교량은 S자형 곡선 보도사장교로 S자형 평면곡선과 역삼각형트러스 횡단면을 가진 보강거더, 곡선반경 내측에 1면으로 배치된 경사 주탑과 modified Fan 타입 주케이블, 수직 백스테이케이블이 적용되었다. 곡선사장교는 직선사장교와 같이 종방향의 거동에만 초점을 두고 장력을 조정할 경우 횡방향으로 과다한 변위와 모멘트가 발생 할 수 있다. 본 연구는 주케이블이 교량의 횡방향 거동에 미치는 영향을 분석하기 위해서, 장력에 의한 주탑의 횡방향 변위 방향에 따라 케이블을 2개 그룹으로 나누었다. 지간중앙부 케이블 그룹을 GR1, 주탑지점부 케이블 그룹을 GR2라 할 때 GR1과 GR2의 조합비율이 보강거더, 받침, 주탑 그리고 수직앵커케이블에 미치는 영향을 분석하였다. 연구대상 교량에 적용된 장력비율을 1.0GR1+1.0GR2라 하였을 때, 1.2GR1+0.8GR2의 조합에서 주탑지점부 보강거더의 좌측과 우측 상현재 응력이 최소가 되었고, 좌우 부재의 편차도 최소가 되었다. 또한, 받침의 수평력, 주탑의 횡방향 변위와 모멘트, 수직백스테이케이블의 장력도 감소하였다. 본 연구는 유사한 기하구조를 가진 사장교의 장력 결정시 기초 자료로 활용될 것으로 기대된다.

사장교의 기하학적 비선형 거동의 해석적 연구 (Analytical Study of Geometric Nonlinear Behavior of Cable-stayed Bridges)

  • 김승준;이기세;김경식;강영종
    • 대한토목학회논문집
    • /
    • 제30권1A호
    • /
    • pp.1-13
    • /
    • 2010
  • 본 연구에서는 사장교의 기하학적 비선형 거동을 기하학적 비선형 유한요소 해석을 통해 분석한다. 사장교의 주탑 및 거더는 휨 모멘트 뿐만 아니라 케이블의 장력에 의해 축력이 작용한다. 즉, 거더와 주탑은 보-기둥 부재와 같이 휨모멘트와 축력의 상호작용에 의한 대변위 거동을 일으킬 수 있다. 본 연구에서는 기하학적 비선형 해석을 통해 완성계 사장교의 대변위 효과, 주탑 및 거더의 보-기둥 효과 그리고 케이블의 새그효과가 모두 고려된 비선형 거동을 검토하였다. 거더 및 주탑은 6자유도 프레임 요소로 모사하고 사장교 케이블은 새그효과를 효율적으로 고려하기 위해 3자유도 등가 트러스 요소를 사용하여 모사하였다. 해석은 먼저 사하중에 대한 초기 형상 해석을 통해 사하중을 고려하고, 이 후 각기 다른 형태의 활하중에 대한 기하학적 비선형 해석을 수행하였다. 해석 후 각 모델의 변형형상, 각 주요 지점의 하중-변위곡선, 케이블 장력의 변화등의 정량적 수치를 분석하여 고려한 활하중 형태 및 사장교 형식에 대한 주요 기하학적 비선형 거동을 규명하였다.

지진력을 받는 해양케이블의 동적 비선형해석 (Dynamic Non-Linear Analysis of Ocean Cables Subjected to Earthquakes)

  • 김남일;신현목
    • 한국지진공학회논문집
    • /
    • 제3권2호
    • /
    • pp.77-86
    • /
    • 1999
  • 이전의 연구에서 하중증분법을 이용하여 지점 변위를 일으키고 자중. 부력, 그리고 조류력을 받는 해양케이블의 초기평형 상태를 결정하였다 본 연구에서는 이 상태를 기준으로 동적으로 지점운동 또는 지진하중에 대하여 첨가질량 및 케이블운동에 의한 Morison force를 고려한 해양케이블의 동적 비선형해석을 수행한다 지점운동과 지진력을 받는 수중케이블에 대하여 기하학적인 비선형해석을 수행하고 해석결과의 분석을 통하여 해양케이블의 동특성을 파악한다.

  • PDF