• Title/Summary/Keyword: Cable Force

검색결과 351건 처리시간 0.132초

Dry friction losses in axially loaded cables

  • Huang, Xiaolun;Vinogradov, Oleg G.
    • Structural Engineering and Mechanics
    • /
    • 제4권3호
    • /
    • pp.330-344
    • /
    • 1996
  • A model of a cable comprising interacting wires with dry friction forces at the interfaces is subjected to a quasi-static cyclic loading. The first cycle of this process, comprising of axial loading, unloading and reloading is investigated analytically. Explicit load-elongation relationships are obtained for all of the above phases of the cycle. An expression for the hysteretic losses is also obtained in an explicit form. It is shown that losses are proportional to the third power of the amplitude of the oscillating axial force, and are in inverse proportion to the interwire friction forces. The results obtained are used to introduce a model of a cable as a solid rod with an equivalent stiffness and damping properties of the rod material. It is shown that the stiffness of the equivalent rod is weakly nonlinear, whereas the viscous damping coefficient is proportional to the amplitude of the oscillation. Some numerical results illustrating the effect of cable parameters on the losses are given.

UHPC 보도사장교의 장기거동에 관한 연구 (A Study on the Long-Term Behavior of UHPC Pedestrian Cable Stayed Bridge)

  • 진원종;김영진;최은석;김병석
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2010년도 춘계 학술대회 제22권1호
    • /
    • pp.109-110
    • /
    • 2010
  • 한국건설기술연구원내에 테스트베드로서 UHPC 보도사장교(Super Bridge I)를 설계 및 완공하였고, 변형률, 가속도, 장력, 풍향풍속, 온도 등의 각종 데이터를 정기적으로 수집할 수 있는 장기계측시스템을 구축하였다. 이는 UHPC 부재의 역학적 특성 및 사용성 평가에 대한 기본 데이터를 제공하여 장대하이브리드사장교의 거동 특성을 추정하는데 큰 도움이 될 것으로 예상된다.

  • PDF

Load deformation characteristics of shallow suspension footbridge with reverse profiled pre-tensioned cables

  • Huang, Ming-Hui;Thambiratnam, David P.;Perera, Nimal J.
    • Structural Engineering and Mechanics
    • /
    • 제21권4호
    • /
    • pp.375-392
    • /
    • 2005
  • Cable supported structures offer an elegant and economical solution for bridging over long spans with resultant low material content and ease of construction. In this paper, a model of shallow cable supported footbridge with reverse profiled pre-tensioned cables is treated and its load deformation characteristics under different quasi-static loads are investigated. Effects of important parameters such as cable sag and pre-tension are also studied. Numerical results performed on a 3D model show that structural stiffness of this bridge (model) depends not only on the cable sag and cross sectional areas of the cables, but also on the pre-tension in the reverse profiled cables. The tension in the top supporting cables can be adjusted to a high level by the pre-tension in the reverse profiled bottom cables, with the total horizontal force in the bridge structure remaining reasonably constant. It is also evident that pre-tensioned horizontally profiled cables can greatly increase the lateral horizontal stiffness and suppress the lateral horizontal deflection induced by eccentric vertical loads.

유연성 반복과정과 비선형유한요소법에 의한 케이블 구조물의 형태탐색 (A Shape Finding of the Cable Structures by Flexibility Iteration Procedure and Nonlinear FEM)

  • 황보석;서삼열;진권태
    • 전산구조공학
    • /
    • 제3권3호
    • /
    • pp.133-140
    • /
    • 1990
  • 케이블 구조물은 응력-변형도관계에서 비선형성이 강하고 대변위에 의해 기하학적 비선형이 도입되므로 해석이 복잡하다. 그러므로 케이블 구조물의 평형형태 탐색과 해석에 앞서 기하학적 비선형을 고려해야만 한다. 본 논문에서는 이러한 문제를 해결하기 위해 케이블, 네트, 전선, 현수케이블 지붕등에 적용될 수 있는 수치해석과정이 소개된다. 이 과정은 두 부분으로 나눌 수 있는데, 하나는 유연성반복과정에의해 등분포하중을 받는 케이블 구조물의 응력과 평형형태를 구하는 것이고, 다른 한 부분은 비선형 유한요소법에 의해 절점외력을 받는 평형형태를 해석하는 것이다.

  • PDF

서해대교 시공 공법 소개 (Construction Method of Seohae Grand Bridge)

  • 윤태섭
    • 한국건설관리학회:학술대회논문집
    • /
    • 한국건설관리학회 2000년도 학술대회지
    • /
    • pp.255-266
    • /
    • 2000
  • Since 1993, Seohae grand bridge has been continued construction for 7 years and will be completed late this year. The bridge is a part of west sea castal highway and consists of 3 types of bridge including precast segmental method, free cantilever method and cable stayed bridge. A cable stayed bridge is the core of this bridge and it consists of 5 span, symetrical cable-stayed bridge with a total length of 990 m. The main span between two H-shaped pylons extending approximately 180 M above massive foundation of a cable stayed bridge is 470 m long and an approach span of that is 260 m long respectively. The circular cofferdam with 16 ea of 25 m diameter flat type sheet pile had been applied to construct foundation. The slipform method had been applied for forming of con'c of two H-shaped pylons with 3 cross beams respectively which is varied horizontally and vertically. The deck has been erected with balanced cantilever method using movable derrick crane. The stay cables is a bundle of parallel individually protected, 7 wire high tensile strands. The strands is hot deep galvanized and sheathed with a tight high density polyethylene coating. A petroleum wax fills all the inter-wire voids. The bundle of strands to prevent from deterioration due to the ambient problem covered with high density polyethylene pipe. The Isotension method has been applied for the stressing of cable strands to ensure uniformity of force in all the strands of a syay and such works has been performed on the stay specially provided in the pylon.

  • PDF

지중케이블 고장전류에 의한 단락전자력 영향분석 (The Analysis of the Electromagnetic Force Generated by the Fault Current of Cable)

  • 김남열;김정년;김성윤;김충식;전승익
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.426-427
    • /
    • 2008
  • 전력의 안정적 공급, 공급 신뢰도 향상 및 도심지 인구밀집 지역의 전력공급 및 미화 등의 축면에서 송전분야에서의 지중화는 필수적이며 지속적으로 증가추세에 있다. 그러나 제한적인 지중공간을 활용함에 따른 여러 문제가 발생하고 있다. 지중선로 고장상황으로 1선 지락, 2선지락, 선간단락, 3상단락 등의 사고가 있으며 이러한 고장상황에서 발생하는 고장전류에 의한 열거동은 지중선로에 악영향을 준다. 그러므로 각 고장상황에 따른 지중선로의 영향에 대한 세부적인 검토가 필요하다. 본 논문에서는 각 고장상황에 따른 검토조건으로 1회선과 2회 선일 경우와 상배열이 정삼각배열, 수평/수직배열, 직각배열일 경우를 선정하여 지중선로에 미치는 영향을 EMTP, IDEARS, MARC를 활용하여 분석하였다.

  • PDF

활선 상태에서의 OPGW 가선 시 전기적인 현상 고찰 (Electrical Consideration in OPGW Live-Line Installation)

  • 백주흠;김정년;전승익;김병수;이인호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 전기설비
    • /
    • pp.127-129
    • /
    • 2005
  • OPGW(Optical Ground Wire) whose demand is increasing worldwide have composite function as optical communication and grounding for preventing transmission line from lightning. While continuous efforts have been made to increase the transmission capacity and speed, the working method to replace the existing ground wire with OPGW under live-line condition is coming to force newly as installation aspects. Particularly, this requirement became more serious in developing country that the electric power supply is not sufficient and power outage is impossible for supply and dead of electric power LS cable Ltd. has developed the new installation method in full live-line condition to solve the confronted problem and to meet the market demand. In this paper, Electric Problems in live-line installation is considered to predict dry-band arcing. This can be used by Makers to predict dry-band arcing in insulating ropes installed on earth wire of power transmission system.

  • PDF

Adaptive MR damper cable control system based on piezoelectric power harvesting

  • Guan, Xinchun;Huang, Yonghu;Li, Hui;Ou, Jinping
    • Smart Structures and Systems
    • /
    • 제10권1호
    • /
    • pp.33-46
    • /
    • 2012
  • To reduce the vibration of cable-stayed bridges, conventional magnetorheological (MR) damper control system (CMRDS), with separate power supply, sensors and controllers, is widely investigated. In this paper, to improve the reliability and performance of the control system, one adaptive MR damper control system (AMRDS) consisting of MR damper and piezoelectric energy harvester (PEH) is proposed. According to piezoelectric effect, PEH can produce energy for powering MR damper. The energy is proportional to the product of the cable displacement and velocity. Due to the damping force changing with the energy, the new system can be adjustable to reduce the cable vibration. Compared with CMRDS, the new system is structurally simplified, replacing external sensor, power supply and controller with PEH. In the paper, taking the N26 cable of Shandong Binzhou Yellow River Bridge as example, the design method for the whole AMRDS is given, and simple formulas for PEH are derived. To verify the effectiveness of the proposed adaptive control system, the performance is compared with active control case and simple Bang-Bang semi-active control case. It is shown that AMRDS is better than simple Bang-Bang semi-active control case, and still needed to be improved in comparison with active control case.

송전선로 ACSR 케이블의 산화에 따른 결빙 특성 평가 (Evaluation of Ice Adhesion Strength on the Oxidation of Transmission Line ACSR Cable)

  • 조희재;김유섭;정용찬;이수열
    • 한국재료학회지
    • /
    • 제29권6호
    • /
    • pp.378-384
    • /
    • 2019
  • Ice accumulation on Aluminum Conductor Steel Reinforced(ACSR) cable during winter is an important matter in terms of safety, economy, and efficient power supply. In this work, the ice adhesion strengths of ACSR cable oxidized during different periods(7 years oxidized and 15 years oxidized) are evaluated. At first, a plate type dry oxidation standard specimen, whose surface characteristics are similar to those of ACSR cable, is prepared. Dry oxidation standard specimens are heat-treated at $500^{\circ}C$ for 20, 60, and 120 minutes in order to obtain different degrees of oxidation. After the dry oxidation, surface properties are analyzed using contact angle analyzer, atomic force microscopy, spectrophotometer, and gloss meter. The ice adhesion strengths are measured using an ice pull-off tester. Correlations between the surface properties and the ice adhesion strength are obtained through a regression analysis indicating a Boltzmann equation. It is revealed that the ice adhesion strength of 15-year oxidized ACSR cable is approximately 8 times higher than that of ACSR-bare.

Strouhal number of bridge cables with ice accretion at low flow turbulence

  • Gorski, Piotr;Pospisil, Stanislav;Kuznetsov, Sergej;Tatara, Marcin;Marusic, Ante
    • Wind and Structures
    • /
    • 제22권2호
    • /
    • pp.253-272
    • /
    • 2016
  • The paper concerns with the method and results of wind tunnel investigations of the Strouhal number (St) of a stationary iced cable model of cable-supported bridges with respect to different angles of wind attack. The investigations were conducted in the Climatic Wind Tunnel Laboratory of the Czech Academy of Sciences in $Tel{\check{c}}$. The methodology leading to the experimental icing of the inclined cable model was prepared in a climatic section of the laboratory. The shape of the ice on the cable was registered by a photogrammetry method. A section of an iced cable model with a smaller scale was reproduced with a 3D printing procedure for subsequent aerodynamic investigations. The St values were determined within the range of the Reynolds number (Re) between $2.4{\cdot}10^4$ and $16.5{\cdot}10^4$, based on the dominant vortex shedding frequencies measured in the wake of the model. The model was oriented at three principal angles of wind attack for each of selected Re values. The flow regimes were distinguished for each model configuration. In order to recognize the tunnel blockage effect the St of a circular smooth cylinder was also tested. Good agreement with the reported values in the subcritical Re range of a circular cylinder was obtained. The knowledge of the flow regimes of the airflow around an iced cable and the associated St values could constitute a basis to formulate a mathematical description of the vortex-induced force acting on the iced cable of a cable-supported bridge and could allow predicting the cable response due to the vortex excitation phenomenon.