• 제목/요약/키워드: Cable Driven Mechanism

검색결과 10건 처리시간 0.011초

교량 케이블 점검용 이동 로봇 개발 (Development of a Climbing Robot for Inspection of Bridge Cable)

  • 김호문;조경호;진영훈;;최혁렬
    • 로봇학회논문지
    • /
    • 제7권2호
    • /
    • pp.83-91
    • /
    • 2012
  • In this paper, we propose a cable climbing robot which can climb up and down the cables in the bridges. The robot mechanism consists of three parts: a wheel based driving mechanism, adhesion mechanism, and safe landing mechanism. The wheel based driving mechanism is driven by tooth clutches and motors. The adhesion mechanism plays the role of maintaining adhesion force by a combination of pantograph, ball screw, and springs even when the power is lost. The safe landing mechanism is developed for guaranteeing the safety of the robot during operations on cables. It can make the robot fall down with reduced speed by dissipating the gravitational forces. The robot mechanism is designed and manufactured for validating its effectiveness.

Design of a novel haptic mouse system

  • Choi, Hee-Jin;Kwon, Dong-Soo;Kim, Mun-Sang
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2002년도 ICCAS
    • /
    • pp.51.4-51
    • /
    • 2002
  • $\textbullet$ A noval haptic mouse system is developed for human computer interface. $\textbullet$ Five bar mechanism is adapted for 2 dof force feedback with virtual environment. $\textbullet$ Double prismatic joint type mechanism is adapted to reflect 1 dof grabbing force feedback. $\textbullet$ Cable driven mechansim is used for actuation to reduce backlash and endow backdrivability. $\textbullet$ Virtual wall perception experiment is conducted to obtain force specification for haptic mouse. $\textbullet$ Average mouse workspace is measured using magnetic position tracker.

  • PDF

뇌졸중 환자의 일상생활 동작 훈련을 위한 1자유도 손 재활 로봇 설계 (Design of a Novel 1 DOF Hand Rehabilitation Robot for Activities of Daily Living (ADL) Training of Stroke Patients)

  • 구광민;장평훈;손민균;신지현
    • 제어로봇시스템학회논문지
    • /
    • 제16권9호
    • /
    • pp.833-839
    • /
    • 2010
  • In this paper, a novel 1 DOF hand rehabilitation robot is proposed in consideration of ADL training for stroke patients. To perform several ADL trainings, the proposed robot can move the thumb part and the part of 4 fingers simultaneously and realize the full ROM (Range of Motion) in grasp. Based on these characteristics, the proposed robot realizes several types of grasp such as cylindrical grasp, lateral grasp, and pinch grasp by using a passive revolute joint that can change the thumb movement direction. The movement of the thumb is driven by a cable mechanism and the part of 4 fingers is moved by a four-bar linkage mechanism.

복강경 수술용 로봇 인스트루먼트의 간접적 작동력 측정법에 관한 연구 (Study for the Indirect Measuring Method of Operational Force in Surgical Robot Instrument)

  • 김지언;이민철;이태경;최승욱;박민규
    • 제어로봇시스템학회논문지
    • /
    • 제16권9호
    • /
    • pp.840-845
    • /
    • 2010
  • This paper proposes the method indirectly measuring the operating force of the end-effect tip of surgical robot instrument which conducts the surgical operation in the body on behalf of the surgeon's hand. Due to the size and safety obligation to the surgical robot instrument, it is difficult to measure the operation force of its tip like grasping force. However the instrument is driven by cable-pulley torque transmission mechanism and when some force is occurred at the tip, then the reaction force appears on the cable as additional tension. Based on this phenomenon, this paper proposes a method to estimate the operating force from measuring reaction force against the driving motor by using a loadcell. And it induces mathematical equation to calculate the force from loadcell by approaching the modulus of elasticity to high order polynomial. And this paper proves the validity of proposed mechanism by experimental test.

슬라이딩 섭동 관측기를 이용한 수술용 로봇 인스트루먼트의 반력 추정 가능성 평가 (Evaluation of a Possibility of Estimation of Reaction Force of Surgical Robot Instrument using Sliding Perturbation Observer)

  • 윤성민;이민철;김지언;강병호
    • 로봇학회논문지
    • /
    • 제7권1호
    • /
    • pp.20-28
    • /
    • 2012
  • In spite of the difficulties and uncertain characteristic of cable driven method, surgical robot instrument has adopted it as driving mechanism for various reasons. To overcome the problem of cable system, previous research applied SMCSPO (sliding mode control with sliding perturbation observer) algorithm as robust controller to control the instrument and found that the value of SPO (sliding perturbation observer) followed force disturbance, reaction force loaded on the tip very similarly. Thus, this paper confirms that the perturbation observer is sufficient estimator which finds out the mount of loaded force on the surgical robot instrument. To prove the proposition, simulation using the similar model with an actual instrument and experimental evaluation are performed. The results show that it is possible to substitute SPO for sensors to measure the reaction force. This estimated reaction force will be used to realize haptic function by sending the reaction force to a master device for a surgeon. The results will contribute to create surgical benefit such as shortening the practice time of a surgeon and giving haptic information to surgeon by using it as haptic signal to protect an organ by making force boundary.

과소 구동 전동의수의 파지력 제어를 위한 햅틱 시스템 개발 (Development of a Haptic System for Grasp Force Control of Underactuated Prosthetics Hands)

  • 임현상;권효찬;김권희
    • 대한기계학회논문집A
    • /
    • 제41권5호
    • /
    • pp.415-420
    • /
    • 2017
  • 과소 구동 전동의수는 가벼우며 비교적 경제적이라는 장점이 있다. 본 연구에서는 적응파지가 가능한 과소 구동 전동의수를 대상으로 경제적인 파지력 제어 시스템을 제안하였다. 근전도 신호로 구동되는 메인 케이블의 장력으로 파지력이 결정되므로 장력에 따라 사용자의 피부에 부착된 진동모터를 구동하는 촉감기반 피드백 시스템을 구성하였다. 진동 신호에 대한 사용자의 감각적 판단을 기반으로 파지력을 추정하고 제어하기 위하여 파지력과 진동 신호 간의 적절한 변환 관계를 수립하고 시제품 성능시험을 하였다. 최소한의 훈련으로 사용자들은 비교적 정확하게 파지력을 제어할 수 있었다.

최소침습술을 위한 의료용 인스트루먼트의 동작 성능 향상 (Improvement in the Control Performance of Instruments used for Minimally Invasive Surgery)

  • 박현준;원종석;박재흥
    • 제어로봇시스템학회논문지
    • /
    • 제19권12호
    • /
    • pp.1160-1166
    • /
    • 2013
  • This paper presents feedforward controllers to improve the control performance of the motion and grasping force of a surgical instrument used in an MIS (Minimally Invasive Surgery) robot. The surgical instrument has a long distance between the drive motors and its active joints. Therefore, the gripper on the instrument is controlled by a cable drive mechanism, which generates a coupled motion between the wrist joint and the grip direction. In order to solve the problem, this paper analyzes the pulley composition of the surgical instrument and proposes feedforward controllers to eliminate the coupled motion. Furthermore, feedforward controllers to regulate the grasping force are proposed to deal with another coupling problem between the grasping force of the instrument and the motion of the instrument joints. The experimental results demonstrate the improved control performance of the motion and grasping force of the instrument.

A class of actuated deployable and reconfigurable multilink structures

  • Phocas, Marios C.;Georgiou, Niki;Christoforou, Eftychios G.
    • Advances in Computational Design
    • /
    • 제7권3호
    • /
    • pp.189-210
    • /
    • 2022
  • Deployable structures have the ability to shift from a compact state to an expanded functional configuration. By extension, reconfigurability is another function that relies on embedded computation and actuators. Linkage-based mechanisms constitute promising systems in the development of deployable and reconfigurable structures with high flexibility and controllability. The present paper investigates the deployment and reconfigurability of modular linkage structures with a pin and a sliding support, the latter connected to a linear motion actuator. An appropriate control sequence consists of stepwise reconfigurations that involve the selective releasing of one intermediate joint in each closed-loop linkage, effectively reducing it to a 1-DOF "effective crank-slider" mechanism. This approach enables low self-weight and reduced energy consumption. A kinematics and finite-element analysis of different linkage systems, in all intermediate reconfiguration steps of a sequence, have been conducted for different lengths and geometrical characteristics of the members, as well as different actuation methods, i.e., direct and cable-driven actuation. The study provides insight into the impact of various structural typological and geometrical factors on the systems' behavior.