• Title/Summary/Keyword: Cable Defect

Search Result 61, Processing Time 0.029 seconds

Comparison of Various Neural Network Methods for Partial Discharge Pattern Recognition (여러가지 뉴럴네트웍 기법을 적용한 부분방전 패턴인식 비교)

  • Choi, Won;Kim, Jeong-Tae;Lee, Jeon-Sun;Kim, Jung-Yoon
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.1422-1423
    • /
    • 2007
  • This study deals with various neural network algorithms for the on-site partial discharge pattern recognition. For the purpose, the pattern recognition has been carried out on partial discharge data for the typical artificial defect using 9 different neural network models. In order to enhance on-site applicability, artificial defects were installed in the insulation joint box of extra-high voltage xLPE cables and partial discharges were measured by use of the metal foil sensor and a HFCT as a sensor. As the result, it is found out that the accuracy of pattern recognition could be enhanced through the application of the Sigmoid function, the Momentum algorithm and the Genetic algorism on the artificial neural networks. Although Multilayer Perceptron (MLP) algorism showed the best result among 9 neural network algorisms, it is thought that more researches on others would be needed in consideration of on-site application.

  • PDF

A Study on Pattern Making of Degradation Type Using K-means (K-means를 이용한 열화 형태의 패턴화에 관한 연구)

  • Lee, Deok-Jin
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.27 no.12
    • /
    • pp.877-882
    • /
    • 2014
  • It has been confirmed that the inner defect of transformer and the perfect diagnosis for aging are closely related to safe electric power transmission system and that the detection of accident and diagnosis technique turn out to be very important issues. Since electric power machinery consists of various kinds of components, however, it is very difficult to make a diagnosis for aging by one parameter. Thus, diagnosis for aging is feasible only through the combination of various parameters. Recently, various expert systems have been developed and applied to diagnosis for aging, but they are not yet reliable enough to apply to the real system. In this paper, XLPE which is ultra high voltage cable insulator material were chosen to investigate the influence of void on insulator material using partial discharge. Obtained data have been processed by PRPD (phased resolved partial discharge) distribution function and K-means. And statistical and cluster distribution of partial discharge have been analysed and investigated.

The Treatment of Neuroma-in-Continuity with Interpositional Nerve Graft and Vein Wrapping - A Case Report - (신경 이식과 정맥 포장을 이용한 연속성 신경종의 치료 - 1예 보고 -)

  • Kwon, Boo-Kyung;Baek, Jong-Ryoon;Kim, Dong-Hwan
    • Archives of Reconstructive Microsurgery
    • /
    • v.19 no.2
    • /
    • pp.93-96
    • /
    • 2010
  • We report a case of 44 years old male patient with neuroma-in-continuity of ulna nerve. In the patient's past history, he had received operative treatment for the open supracondylar fracture of right distal humerus and ulnar nerve injury at 10 years ago, and neurolysis was tried 2 times due to severe neuropathic pain. Despite of these operations, the symptom was not improved. In operative field, we noticed neuroma-in-continuity and decided to resect the neuroma until normal nerve fascicle was noted. The nerve cable graft was done with auto sural nerve on the defect site and the nerve was wrapped with small saphenous vein. At post operative 7 months, pain was markedly decreased and sensory recovery was slightly improved and patient was satisfied with the result.

  • PDF

Design and implementation of ESD cable Disconnection Monitoring System (ESD 접지선 단선 모니터링 시스템 설계 및 구현)

  • Seong, Jung-Mo;Chung, Young-Suk;Park, Koo-Rack
    • Journal of the Korea Convergence Society
    • /
    • v.8 no.8
    • /
    • pp.77-82
    • /
    • 2017
  • In the splay manufacturing process, conveyor systems are widely used for conveying panels. In this conveyor, a large number of grounding lines are used in order to prevent a product failure due to static electricity. In many cases, the grounding line is disconnected due to the rotation of the transporting roller or curling, leading to product failure. In order to solve such a problem, there is a growing need for a system capable of detecting disconnection of a ground wire in real time. Therefore, in this paper, we propose a disconnection monitoring system of ESD (Electro-Static Discharge) ground wire caused by friction between the conveyor drive part and the panel. The proposed system is a monitoring system that can detect disconnection and disconnection of ground wire using ATmega 2560 and Wheatstone Bridge circuit. It can detect disconnection of ground wire immediately and can take measures to reduce the defect rate due to static electricity. The system proposed in this paper is expected to be applicable to the production and test equipments of all industries where the ground wire is used.

Defect Diagnosis of Cable Insulating Materials by Partial Discharge Statistical Analysis

  • Shin, Jong-Yeol;Park, Hee-Doo;Lee, Jong-Yong;Hong, Jin-Woong
    • Transactions on Electrical and Electronic Materials
    • /
    • v.11 no.1
    • /
    • pp.42-47
    • /
    • 2010
  • Polymer insulating materials such as cross linked polyethylene (XLPE) are employed in electric cables used for extra high voltage. These materials can degrade due to chemical, mechanical and electric stress, possibly caused by voids, the presence of extrinsic materials and protrusions. Therefore, this study measured discharge patterns, discharge phase angle, quantity and occurrence frequency as well as changes in XLPE under different temperatures and applied voltages. To quantitatively analyze the irregular partial discharge patterns measured, the discharge patterns were examined using a statistical program. A three layer sample was fabricated, wherein the upper and lower layers were composed of non-void XLPE, while the middle layer was composed of an air void and copper particles. After heating to room temperature and $50^{\circ}C$ and $80^{\circ}C$ in silicone oil, partial discharge characteristics were studied by increasing the voltage from the inception voltage to the breakdown voltage. Partial discharge statistical analysis showed that when the K-means clustering was carried out at 9 kV to determine the void discharge characteristics, the amount discharged at low temperatures was small but when the temperature was increased to $80^{\circ}C$, the discharge amount increased to be 5.7 times more than that at room temperature because electric charge injection became easier. An analysis of the kurtosis and the skewness confirmed that positive and negative polarity had counterclockwise and clockwise clustering distribution, respectively. When 5 kV was applied to copper particles, the K-means was conducted as the temperature changed from $50^{\circ}C$ to $80^{\circ}C$. The amount of charge at a positive polarity increased 20.3% and the amount of charge at a negative polarity increased 54.9%. The clustering distribution of a positive polarity and negative polarity showed a straight line in the kurtosis and skewness analyses.

Analysis of Partial Discharge Phenomena by means of CAPD (CAPD기법을 이용한 부분방전 현상 해석에 관한 연구)

  • Kim, Sung-Hong
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.07b
    • /
    • pp.939-944
    • /
    • 2002
  • PD phenomena can be regarded as a deterministic dynamical process where PD should be occurred if the local electric field be reached to be sufficiently high. And thus, its mathematical model can be described by either difference equations or differential equations using several state variables obtained from the time sequential measured data of PD signals. These variables can provide rich and complex behavior of detectable time series, for which Chaos theory can be employed. In this respect, a new PD pattern recognition method is proposed and named as 'Chaotic Analysis of Partial Discharges (CAPD)' for this work. For this purpose, six types of specimen are designed and made as the models of the possible defects that may cause sudden failures of the underground power transmission cables under service, and partial discharge signals, generated from those samples, are detected and then analyzed by means of CAPD. Throughout the work, qualitative and quantitative properties related to the PD signals from different defects are analyzed by use of attractor in phase space, information dimensions ($D_0$ and D2), Lyapunov exponents and K-S entropy as well. Based on these results, it could be pointed out that the nature of defect seems to be identified more distinctively when the CAPD is combined with traditional statistical method such as PRPDA. Furthermore, the relationship between PD magnitude and the occurrence timing is investigated with a view to simulating PD phenomena.

  • PDF

Mechanical Properties and Smoothness of Semiconductive Shield for Power Transmission by Carbon Black Content (카본블랙의 함량에 따른 송전용 반도전 재료의 기계적 특성 및 Smoothness)

  • Lee, Kyoung-Yong;Yang, Jong-Seok;Lee, Kwan-Woo;Choi, Yong-Sung;Park, Dae-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.11a
    • /
    • pp.301-307
    • /
    • 2004
  • To improve mean-life and reliability of power cable in this paper, we have investigated stress-strain and smoothness showing by changing the content of carbon black that is semiconductive additives for underground power transmission. Specimens were made of sheet form with the three of existing resins and the nine of specimens for measurement. Stress-strain of specimens was measured by TENSOMETER 2000. A speed of measurement was 200[mm/min], ranges of stress and strain were $400(Kgf/cm^2)$ and 600[%]. In addition tests of stress-strain were progressed by aging specimens at air oven. Finally we wished to look for protrusion of specimens by using smoothness tester. According to increasing the content of carbon black from this experimental result, yield stress was increased, while strain was decreased. And stress-strain were decreased some after aging because of oxidation reaction of chemical defect. Lastly surface of specimens smoothed generally.

  • PDF

Defects Detection of the Underground Distribution Power Cables by Very Low Frequency Voltage Source (초저주파전원을 이용한 지중배전 전력케이블의 결함검출)

  • 김주용;송일근
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.12 no.3
    • /
    • pp.45-50
    • /
    • 1998
  • This paper presents experimental results on the application of very low frequency(VLF) voltage to replace conventional DC test as an after laying test for underground distribution cables. We carried out several tests to prove defects detecting ability of VLF test on the 5m length real cables having knife-cut or needle type defects which is made in our La.. Through this experiment we proved it is very difficult to initiate electrical tree from the defects inside of the cable insulation but once the electrical tree is initiated it grows very fast and VLF does not make new defects and expand the defect. Therefore VLF test equipment for quality inspection test of manufacture is more effective than field application for underground distribution cables.

  • PDF

Design of Wired and Wireless linkage Hybrid Sensor Network Model over CATV network (CATV망을 이용한 유무선 연동의 하이브리드 센서 네트워크 모델 설계)

  • Lee, Kyung-Sook;Kim, Hyun-Deok
    • Convergence Security Journal
    • /
    • v.12 no.3
    • /
    • pp.67-73
    • /
    • 2012
  • In this paper, in order to overcome the disadvantage of wireless-based sensor network, a hybrid sensor network using wired and wireless linkage is proposed. Proposed a wired and wireless linkage hybrid sensor network can compensate the defect of poor transmission at the indoor wireless environment, and can be free from interference between a wireless LAN and Bluetooth of the same frequency bandwidth due to an attribute of low-loss transmission at the CATV network. Also, proposed a wired and wireless linkage hybrid sensor network make use of CATV network which is well-built infrastructure, is more efficient to design network, assure a stability and high reliability of the sensor network as providing a stability for an inaccuracy and a predictable transmission link for the existing wireless network.

Developing die and Peripheral Equipment Used for the Manufacture of Octagonal Outlet Boxes (8각 아웃렛 박스 제조용 금형 및 주변기기 개발)

  • Chio Kye-Kwang
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.6 no.6
    • /
    • pp.560-565
    • /
    • 2005
  • This paper deals with the development of manually operated die used for the manufacture of octagonal boxes into two sets of automated die. In particular, theoctagonal boxes are used fur the switch boxes intended fur the cable conduit of buildings or f3r wiring connection. Manufacturing these boxes requires forming the materials using the primary press before they undergo 2nd through 6th processing by the press machine including the four sides of the octagonal outlet box and bending. Such complicated process hikes up labor cost, slows down production, and results in defect rate of $10\%$ or higher; hence the overall rise in manufacturing cost. Moreover, workers avoid this type of work due to the roar and vibration coming from the press and the risk of accident. To eliminate such phenomenon, a CAM die made by integrating five sets of die into one set of die and an automatic conveyor system were developed. As a result, unmanned work was realized with only two units of press and two sets of die; thus solving the problem of work being avoided and saving on manufacturing cost.

  • PDF