• Title/Summary/Keyword: Cable요소

Search Result 267, Processing Time 0.025 seconds

Vibrational Characteristics on the Cables in Cable Stayed Bridge (사장교 케이블의 진동거동 특성)

  • Sung, Ikhyun
    • Journal of the Society of Disaster Information
    • /
    • v.13 no.2
    • /
    • pp.249-257
    • /
    • 2017
  • Recently, a cable disconnection accident occurred due to a lightning strike at the Seohae Bridge located in Dangjin-Pyeongtaek City. This is a natural occurrence, but it is a recall that it is very important to review the safety issues due to the disconnection of cable bridges. In other words, the role of cables in cable bridges has a profound effect on the safety of the structure, and it has become necessary to grasp the effect on the entire structural system. The cable bridge is an economic bridge that builds the main tower and supports the bottom plate by cable. The influence of the cable is the main member, which is a big influence on the safety of the whole bridge system. In the cable-stayed bridge, the cables exhibit nonlinear behavior because of the change in sag, due to the dead weight of the cable, which occurs with changing tension in the cable resulting from the movement of the end points of the cable as the bridge is loaded. Modal analysis is conducted using the deformed dead-load tangent stiffness matrix. A new concept was presented by using divided a cable into several elements in order to study the effect of the cable vibration (both in-plane and swinging) on the overall bridge dynamics. The result of this study demonstrates the importance of cable vibration on the overall bridge dynamics.

An analysis of structural characteristic's changing as stranded wire's pitch changing of wind turbine type cable's conductor by CAE techniques (CAE 기법을 활용한 풍력 케이블의 도체 연선 피치 변화에 따른 구조적 특성 변화 분석)

  • Park, Moon-Gun;Jang, Jin-Wook
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.276_277
    • /
    • 2009
  • 풍력 케이블의 nacelle부와 Tower 사이에 포설되는 케이블은 사용 환경의 특성상 장력+비틀림의 스트레스를 받는다. 이러한 사용 환경 때문에 케이블은 전기적인 특성 뿐 아니라 반복 운동을 하는 환경에 대해 구조적인 특성에 대해서도 검토가 요구되어진다. 본 논문에서는 풍력 케이블의 핵심 검토 요소로 도체의 구조적 위험 요소를 줄이기 위한 연구 대상으로 도체의 (*)피치 변화의 특성을 분석하였으며, 피치가 길어지면 도체에 발생되어지는 응력(스트레스)이 작아질 것이고 피치가 짧아지면 도체에 발생되어지는 응력(스트레스)이 커질 것이라는 일반적인 상식을 벗어나 각 피치별 응력(스트레스)의 최저점들을 찾게 되었고 그 중 유연성을 함께 고려하여 품질의 향상을 기여하는 최적 피치를 선정하였다.

  • PDF

System Reliability-Based Safety Assessment of Steel Cable-Stayed Bridges (체계신뢰성방법에 기초한 강사장교의 안전도평가)

  • 조효남;임종권;박경훈
    • Computational Structural Engineering
    • /
    • v.11 no.4
    • /
    • pp.351-360
    • /
    • 1998
  • 본 논문에서는 실용적 체계신뢰성에 기초한 강사장교의 안전도평가를 위한 체계적인 모형을 제안하였다. 공용중인 강사장교의 시스템 안전도평가를 위하여 요소신뢰성해석을 위한 케이블, 주형 그리고 주탑의 한계 상태모형과 각 요소들간의 조합파괴를 포함하는 주파괴경로를 정의할 수 있는 체계신뢰성해석 모형을 제안하였다. 요소신뢰성해석을 위한 수치해석기법으로는 AFOSM(Advanced First Order Second Moment) 방법을 사용하였고, 체계신뢰성해석을 위해서는 부분 ETA(partial Event Tree Analysis) 모형을 사용하였다. 제안된 방법의 타당성을 고찰하기 위하여 진도대교의 안전도 평가에 적용하였다. 부분 ETA 모혀을 사용한 체계신뢰성 평가 방법은 기존의 요소신뢰성 방법에 비해 구조물의 여용성을 충분히 반영하는 상당히 합리적이며 실제적인 결과를 보여주는 실용적인 방법으로 판단된다.

  • PDF

AC Loss Characteristic Analysis of Superconducting Power Cable for High Capacity Power Transmission (대용량 전력 전송을 위한 초전도 전력케이블의 교류손실 특성 분석)

  • Lee, Seok-Ju
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.24 no.2
    • /
    • pp.57-63
    • /
    • 2019
  • In order to facilitate the supply of gradually increasing power demand, it is also necessary to increase the number of power cables for power transmission as well as generation facilities. However, the expansion of electric power cables for supplying power to most urban areas requires a space for installation of additional cables, and the space for installing cables in domestic downtown areas is insufficient at present. The superconducting power cable, which can transmit more power with the same size, has emerged as an alternative to overcome the insufficient cable installation space. However, superconducting power cables, which have the advantage of large power transmission, have some losses in the AC (Alternating Current) system. Therefore, the design and analysis of AC losses are essential to introduce superconducting power cables in AC power transmission systems. In this paper, we analyze the AC loss of various superconducting power cables and consider the actual superconducting power cables and their application to the system. Although there is a theoretical calculation method of AC loss for single superconducting wire, it is not easy to calculate AC loss of superconducting power cable with large number. Therefore, the authors intend to analyze various kinds of superconducting power cable AC loss by using electromagnetic finite element analysis considering E-J (Electric field-Current density) characteristics of superconductivity. The analysis of the AC loss characteristics of the superconducting power cable will be an important factor in the design and development of the superconducting power cable to be applied to the actual system.

A Study on the Thermal Analysis of Fire-Resistance Cable using FEM (유한요소법을 이용한 내화전선의 열해석에 관한 연구)

  • 오홍석;이상호
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.53 no.5
    • /
    • pp.338-343
    • /
    • 2004
  • In general, the insulation and protective sheaths on electrical conductors are made of combustible substances like PVC, natural or synthetic rubbers, and other organic or synthetic materials. When an electrical fire starts due to overheating of conductors/joints or sparking/arcing, the first thing to ignite is usually the insulation on the cables. When the insulation bums, the produced fumes are very toxic. To solve the problem, we have surely need the fire resistance cable that doesn't bum in a high temperature and emit toxic fume for operating a disaster prevention installation. In this paper, we have simulated the thermal analysis for the fire resistance cable according to the values of current in a overload and a short, and the values of outside flame with the fire resistance cable of the L's company product(600 V, FR-8 : Four Core) using the finite element method(Flux2D).

Transient Phenomena Analysis and Estimation According to Unbalance Factors on Underground Power Cable Systems (지중송전계통에서 불평형 구성요소에 따른 과도현상 해석 및 평가)

  • Jung Chae-Kyun;Lee Jong-Beom;Kang Ji-Won;Lee Dong-Il
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.54 no.8
    • /
    • pp.410-417
    • /
    • 2005
  • This paper analyses the transient phenomena against single line to ground fault and lightning surge on underground power cable systems. For analysis in various fault conditions, several actual underground power cable systems are modeled using ATP In ground fault, the transient characteristic of the conductor and the sheath according to the fault current and the installation types of CCPU are analysed. In lightning surge strokes, the various unbalanced conditions including the length of crossbonded lead, the breakdown of CCPU and distance unbalance are considered. This paper is expected to contribute the establishment of proper protection methods against transients on underground power cable systems.

Nonlinear Analysis of IPS System using the multi-noded cable element (다절점 케이블요소를 이용한 IPS 시스템의 비선형 해석)

  • Lee Jun-Seok;Kim Moon-Young;Han Man-Yop;Kim Sung-Bo;Kim Nak-Kyung
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2006.04a
    • /
    • pp.623-630
    • /
    • 2006
  • In this paper, a geometric nonlinear analysis procedure of beam-column element including multi-noded cable element is presented. For this, first a stiffness matrix about beam-column element which considers the second effect of initial force supposing the curved shape at each time step with Hermitian polynomials as the shape function is derived and second, tangent stiffness matrix about multi-noded cable element being too. To verify geometric nonlinearity of this newly developed multi-noded cable-truss element, IPS(Innovative Prestressed Support) system using this theory is analysed by geometric nonlinear method and the results are compared with those by linear analysis.

  • PDF

Finite Element Analysis on Impedance Parameters of Anchor Plate of Structural Cables Under Cable Force Changes (구조용 케이블의 장력 변화에 따른 정착부의 임피던스 특성에 대한 유한요소해석)

  • Nguyen, Khac-Duy;Park, Jae-Hyung;Hong, Dong-Soo;Lee, Ju-Won;Kim, Jeong-Tae;Na, Won-Bae
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2010.04a
    • /
    • pp.783-786
    • /
    • 2010
  • This paper presents a finite element analysis on impedance parameters of anchor plates of structural cables under the change in cable forces. To achieve the objective, four approaches are implemented as follows: Firstly, theoretical background of electro-mechanical impedance is described. Secondly, anchor plates of structural cables are selected to experimentally examine the relationship between impedance parameters and cable force changes. Thirdly, finite element analysis is performed to verify the experimental results. Fourthly, a comparison between the experimental and numerical analysis on impedance parameters of anchor plate of structural cables under cable force changes is carried out.

  • PDF

An Improved Finite Element Analysis Model of Offshore Cable-Supported Structures (해양 케이블 지지구조물의 구조해석을 위한 개선된 유한요소해석모델)

  • KIM SUN-HOON;SONG MYUNG-KWAN;NOH HYUK-CHUN
    • Journal of Ocean Engineering and Technology
    • /
    • v.18 no.6 s.61
    • /
    • pp.51-57
    • /
    • 2004
  • In this study, the improved three-dimensional analysis model designed for a more accurate analysis of marine cable-supported structures, is presented. In this improved analysis model, the beam elements, of which the stability function is derived using Taylor's series expansions, are used to model space frame structures, and the truss elements. The equivalent elastic modulus of the truss elements is evaluated on the assumption that the deflection curve of a cable has a catenary function. By using the proposed three-dimensional analysis model, nonlinear static analysis is carried out for some cable-supported structures. The results are compared with previous studies and show good agreement with their findings.

Determination of the Boundary of Parameters for Stabilization of Truss Structures Stabilized by Cable Tension (장력안정트러스 구조물의 안정화를 위한 매개변수의 범위 결정에 관한 연구)

  • 권택진;한상을;최옥훈
    • Computational Structural Engineering
    • /
    • v.10 no.3
    • /
    • pp.195-202
    • /
    • 1997
  • The charateristics of stabilization for stabilized truss unit-structures with cable and truss are investigated in this paper. This unit system is composed of a central post and eight cables, and is connected by hinge joints, and stabilized by self-equilibrated stress field. As this unit structure itself is a statically closed and stabilized system individually, it can be employed to assemble structures with various configurations. In this study, for stabilization of truss structures stabilized by cable tension, the structural concept of unit structures, the range of various geometrical parameters and the relationship of governing parameters about unit systems are explained.

  • PDF