In-Cabinet Response Spectrum Comparison of Battery Charger by Numerical Analysis and Shaking Table Test (수치해석 및 진동대 실험을 통한 충전기의 캐비닛내부응답스펙트럼(ICRS) 결과 비교)

  • Lee, Sangjin;Choi, In-Kil;Park, Dong-Uk;Eem, Seung-Hyun
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.15 no.1
    • /
    • pp.53-61
    • /
    • 2019
  • The seismic capacity of electric cabinets in Nuclear Power Plants (NPPs) should be qualified before installation and be maintained during operation. However it can happen that identical devices cannnot be produced for replacement of devices mounted in electric cabinets. In case of when no In-Cabinet Response Spectrum (ICRS) is available for new devices, ICRS can be generated by using Finite Element Analysis (FEA). In this study we investigate structural response and ICRSs of battery charger which is supplied to NPPs. Test results on the battery charger are utilized in this study. The response is measured by accelerometers installed on the housing of the battery charger and local panels in the battery charger. Numerical analysis model is established based on resonant frequency search test results and validated by comparison with 2 types of earthquake testing results. ICRSs produced from the numerical model are compared with measured ICRSs in the seismic tests. Developed analysis model is a simple reduced model and anticipates ICRSs quite well as measured response in the tests overall despite of its structural limitation.

Design of the Through Characteristics Classification Reagent Management System (성상 분류를 통한 시약 관리 시스템 설계)

  • Choi, Hyung-Wook;Jang, Jae-Myung;Chung, Chee-Oh;Kim, Ho-Sung;Jung, Hoe-Kyung
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2016.10a
    • /
    • pp.798-799
    • /
    • 2016
  • Reagent Cabinet of existing that management does not classify the reagents by characteristics it has a problem that can result dangerous situations. Also, the situation impossible the ability to control the reagent cabinet from outside in the event of dangerous situations. In this paper, design a system for managing reagents it can be classified according to the characteristics and the reagent cabinet management on a mobile device. Utilizing the characteristics classification from first to sixth classification management to fit the classification of each reagent. The mobile device transmits the sensor control, reagent and sensor data monitoring, dangerous situation occurs when the alarm message. Accordingly, it is expected through the characteristics classification reduce accidents in the laboratory if the dangerous situation will be a prompt action from the outside.

  • PDF

A Study on the Yin and Yang Poison (陰陽毒) in 『Donguisusebowon』 (『동의수세보원』 음양독(陰陽毒)에 대한 고찰)

  • Lee, Jeongyun
    • Journal of Sasang Constitutional Medicine
    • /
    • v.34 no.1
    • /
    • pp.28-36
    • /
    • 2022
  • Objectives The purpose of this study was to enhance the understanding of Yin and Yang poison by examining and comparing the views of Je-ma Lee and the medicine scholars before Je-ma Lee, including Zhang Zhongjing. Methods We examined and compared the contents related to Yin and Yang poison in 『Essential Prescriptions from the Golden Cabinet (金匱要略)』, 『Donguibogam (東醫寶鑑)』, and 『Donguisusebowon (東醫壽世保元)』. Results and Conclusion In 『Essential Prescriptions from the Golden Cabinet』, Zhang Zhongjing described the symptoms of Yin and Yang poison respectively, but could not suggested each prescription. In 『Donguibogam』, there were several prescriptions for Yin and Yang poison, respectively. In 『Donguisusebowon』, Yang poison belonged to the Soyangin and Taeeumin disease, Yin poison belonged to the Soeumin disease. Je-ma Lee emphasized that interior heat, which has grown suddenly should be controlled quickly for treatment of Yang poison in Soyangin and Taeeumin. And, in order to treat Yin poison caused by chronic course in Soeumin, Ginseng should be used a lot to help the Yang energy. Also, it is a better treatment to take the medicine ahead of time before the disease develops into Yin poison.

Effects of the Excitation Level on the Dynamic Characteristics of Electrical Cabinets of Nuclear Power Plants (진동수준이 원자력발전소 전기 캐비닛의 동특성에 미치는 영향)

  • Cho, Sung-Gook;Kim, Doo-Kie;Go, Sung-Hyuk
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.14 no.3
    • /
    • pp.23-30
    • /
    • 2010
  • Seismic qualification (SQ) is required prior to the installation of safety related electrical cabinets in nuclear power plants (NPPs). Modal identification of the electrical equipment is one of the most significant steps to perform SQ, and is an essential process to construct a realistic analytical model. In this study, shaking table tests were conducted to identify a variation of the dynamic characteristics of a seismic monitoring system cabinet installed in NPPs according to the excitation level. Modal identification of the cabinet has been performed by a frequency domain decomposition method. The results of this study show that the dynamic properties of the cabinet are nonlinearly varied according to the excitation level and the specimen behaves significantly in a nonlinear manner under safe shutdown earthquake motion in Korea. The main sources of the nonlinear behavior of the specimen have been judged by friction forces and geometrical nonlinearity rather than material nonlinearity. The nonlinear variation of the dynamic characteristics of the electrical cabinet might be accepted as an important fact that should be considered during the SQ of safety related equipment.

Seismic Fragility Evaluation of Cabinet Panel by Nonlinear Time History Analysis (비선형시간이력해석을 이용한 수배전반의 지진취약도 도출)

  • Moon, Jong-Yoon;Kwon, Min-ho;Kim, Jin-Sup;Lim, Jeong-Hee
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.2
    • /
    • pp.50-55
    • /
    • 2018
  • Earthquakes are almost impossible to predict and take place in a short time. In addition, there is little time to take aggressive action when an earthquake occurs. Therefore, there are more casualties and property damage than with other natural disasters. Recently, earthquakes have been occurring all over the world. As the number of earthquakes increase, studies on the safety of structures are being carried out. On the other hand, there are few studies on the electric facilities, which are relatively non - structural factors. Currently, electrical equipment in Korea is often not designed for earthquake safety and is quite vulnerable to damage when an earthquake occurs. Therefore, in this study, modeling was conducted through ABAQUS similar to an actual cabinet panel and 3D dynamic nonlinear analysis was performed using a natural seismic. According to seismic zone I and normal ground rock conditions of the power transmission and transmission facility seismic design practical guide, the maximum response acceleration of the performance level was 0.157g. In this study, however, it was not safe to reach the limit state of 30% of the analytical result at 0.1g for the general cabinet panel. From the results, the seismic fragility curve was derived and analyzed. The derived seismic fragility curve is presented as a quantitative basis for determining the limit state of the cabinet panel and can be utilized as basic data in related research.

Heat Exchange Element Made of Plastic for Cooling of Telecommunication Cabinet (통신 함체 냉각용 플라스틱 재질의 열교환 소자)

  • Kim, Nae-Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.1
    • /
    • pp.702-708
    • /
    • 2017
  • The heat generation rate in a telecommunications cabinet keeps increasing due to the increased usage of mobile devices. Insufficient removal of the heat increases the cabinet temperature, which results in the malfunction of the electronic devices. In this study, tests were conducted on aluminum and plastic heat exchangers for cooling a telecommunications cabinet, and the results were compared with theoretical predictions. The aluminum heat exchanger comprised counter flow parallel channels with 4.5-mm pitch, and the plastic heat exchangers comprised cross or cross-counter flow triangular channels with 2.0-mm pitch. The volume of the cross flow heat exchanger was the same as that of the aluminum heat exchanger, and the volume of the cross-counter heat exchanger was 33% larger than that of the aluminum heat exchanger. The results show that the heat transfer rate is the highest for the cross-counter heat exchanger and lowest for the aluminum one. The temperature efficiency of the cross-counter heat exchanger was 56% higher than that of the aluminum one and 20% higher than that of the cross flow heat exchanger. The pressure drop of the cross-counter heat exchanger was approximately the same as that of the aluminum one. The heat exchange efficiency was the highest for the cross-counter heat exchanger and lowest for the cross flow heat exchanger. The theoretical analysis somewhat overestimated or underestimated the data.

Development of the Safety Cabinet for Respiratory High-Pressure cylinder according to Consequence Analysis of Physical Explosion Damage (호흡용 고압용기 파열 피해영향 분석에 따른 안전충전함 개발)

  • Jang, Kap Man;Kim, Jeong Hwan;Jang, Yu Ri;Lee, Jin Han;Jo, Young Do
    • Journal of the Korean Institute of Gas
    • /
    • v.20 no.6
    • /
    • pp.80-88
    • /
    • 2016
  • A fire station and scuba have operated filling facilities for respiratory high-pressure cylinder without getting authority or reporting according to High-Pressure Gas Safety Control Act. They need facility improvement and special management to make provision for the time of accident during filling process. The Government have strived to correct illegal operations and suggested an alternative, establishing and operating the safety cabinet. It insures a safety being distance from danger caused by overpressure and a safety provoked by the protective wall equals or superiors. The safety cabinet is required to have an internal structure that smoothly distribute overpressure at the time of rupture. Plus, it needs to minimize fragments. It is also equipped with the performance of protective wall that makes overpressure to outside vent on the place where there is no person (top or bottom). This study calculated the consequence of physical explosion damage and built a prototype of safety cabinet. In addition, through the gas burst test, it derives for the ways to mitigate the physical explosion damage.

An Experimental Study on the Furniture Choice and Arrangement Using Scale Down Models according to the Size of Space (축소모형을 이용한 평형별 가구선택과 배치에 대한 실험적 연구)

  • 임소연;안옥희
    • Journal of the Korean housing association
    • /
    • v.6 no.1
    • /
    • pp.39-50
    • /
    • 1995
  • The Plan for effective usage of living room must be suggested because families primarily use living room for public space. And from the viewpoint of function and decoration. the kind of furniture. furniture occupancy quantity. and the arrangement of furniture have much affect on using a dwelling space. So this study will suggest basic data for a good furniture usage through experiment using scale down models. To analyze the data. frequency and percentage were used by running SPSS $PC^+$ program. The major results are as follows. In an experiment using living room and furniture models(Scale 1/20). according to the size of space. TV sizes and furniture occupancy quantity were in proportion to size and space of the living room. Also they chose various types of tea-table and side-tables. In small spaces. subjects chose simple arrangement types (no sofa or I type sofa and cabinet). but in large spaces. they chose \ulcorner type or \ulcorner type sofa and cabinet.

  • PDF