• 제목/요약/키워드: Cabinet

검색결과 362건 처리시간 0.031초

통신 함체 냉각용 알루미늄과 플라스틱 열교환 소자의 성능 비교 (Aluminum and Plastic Heat Exchange Element : A Performance Comparison for Cooling of Telecommunication Cabinet)

  • 김내현
    • 설비공학논문집
    • /
    • 제29권6호
    • /
    • pp.279-288
    • /
    • 2017
  • Heat generation rate in a telecommunication cabinet increases due to the continued usage of mobile devices. Insufficient removal of heat intensifies the cabinet temperature, resulting in the malfunction of electronic devices. In this study, we assessed both aluminum and plastic heat exchangers used for cooling of the telecommunication cabinet, and compared the results against theoretical predictions. The aluminum heat exchanger was composed of counter flow parallel channels of 4.5 mm pitch, and the plastic heat exchangers were composed of cross flow triangular channels of 2.0 mm pitch. Samples were made by installing two plastic heat exchangers in both series and parallel. Results showed that the heat transfer rate was highest for the series cross flow heat exchanger, and was least for the aluminum heat exchanger. The temperature efficiency of the series cross flow heat exchanger was 59% greater than that of the aluminum heat exchanger, and was 4.3% greater than that of the parallel cross flow heat exchanger. In contrast, the pressure drop of the parallel cross flow heat exchanger was significantly lower than other samples. The heat exchange efficiency was also the largest for the parallel cross flow heat exchanger. The theoretical analysis predicted the temperature efficiency to be within 3.3%, and the pressure drop within 6.1%.

열유동 해석을 이용한 컴퓨터 구조의 소형화 설계 (Optimal Miniaturization of Desk-Top Computer by Thermal Design)

  • 박성관
    • 한국CDE학회논문집
    • /
    • 제4권4호
    • /
    • pp.318-326
    • /
    • 1999
  • Recently, electronic systems including computers have been rapidly shrinking in size while at the same time the complexity and the capability of these systems continue to grow/sup [1]/. Thus, system volumes have decreased as system power has increased, resulting in dramatic increases in system heat density. The high temperature of the computer system is considered as the major reason for low performance and shortening life of the product. It is necessary to solve this problem due to the heat density increased and to develop the design skill of the computer cabinet according to miniaturization. M4500 desk-top computer was selected for analyzing the thermal management inside cabinet. The cabinet volume, the configuration of the heating devices, the size and location of air ventilation, and the fan selection have been investigated as the important parameters to find out an optimal cabinet design. The objectives of this project were to analyze which design parameters would affect cooling performance by thermal strategy, to design an optimal model, and to measure the temperatures of the main parts to confirm the effect of the thermal design. The temperatures of each part of the optimal model were compared with those of the existing model. As a result. the volume of this miniaturized model was about 16% smaller than that of M4500 without any change in operating performance.

  • PDF

군용 차량 탑재 캐비닛 구조물의 구조건전성 분석 (Analysis of the Structural Robustness of Cabinet Structure Equipped with Military Vehicles)

  • 손동훈;강광희;최지호;박도훈
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2014년도 추계학술대회 논문집
    • /
    • pp.273-276
    • /
    • 2014
  • The development of a vehicle-mounted radar to detect the location of enemy artillery is mainly mounted during operation to the mobility of the equipment and efficiency of utilization range. It is equipped with an electronic device responsible for the operation of the radar system. Electronic equipments is performed functionality imparted without an error-specific in spite of disturbances such as vibration / shock caused by vehicle movement. Therefore, vibration / shock resistance is held to prevent damaging from vibration / shock generated from the outside environment during operation. In addition, a standardized and specified cabinet structure equipped with electronic equipment is placed in shelter to ensure additional safety for vibration / shock. In this study, it is evaluated by analytical method with vibration / shock resistance of the cabinet structures for ensuring structural safety factor is applied to the aluminum. It is verified the reliability of the structure and structural dynamics to verify by calculated natural frequencies adding the weight of the cabinet structure and the structural displacement and stress results confirmed with vibration / shock caused by the vehicle movement.

  • PDF

Fragility assessment for electric cabinet in nuclear power plant using response surface methodology

  • Tran, Thanh-Tuan;Cao, Anh-Tuan;Nguyen, Thi-Hong-Xuyen;Kim, Dookie
    • Nuclear Engineering and Technology
    • /
    • 제51권3호
    • /
    • pp.894-903
    • /
    • 2019
  • An approach for collapse risk assessment is proposed to evaluate the vulnerability of electric cabinet in nuclear power plants. The lognormal approaches, namely maximum likelihood estimation and linear regression, are introduced to establish the fragility curves. These two fragility analyses are applied for the numerical models of cabinets considering various boundary conditions, which are expressed by representing restrained and anchored models at the base. The models have been built and verified using the system identification (SI) technique. The fundamental frequency of the electric cabinet is sensitive because of many attached devices. To bypass this complex problem, the average spectral acceleration $S_{\bar{a}}$ in the range of period that cover the first mode period is chosen as an intensity measure on the fragility function. The nonlinear time history analyses for cabinet are conducted using a suite of 40 ground motions. The obtained curves with different approaches are compared, and the variability of risk assessment is evaluated for restrained and anchored models. The fragility curves obtained for anchored model are found to be closer each other, compared to the fragility curves for restrained model. It is also found that the support boundary conditions played a significant role in acceleration response of cabinet.

Variation of reliability-based seismic analysis of an electrical cabinet in different NPP location for Korean Peninsula

  • Nahar, Tahmina Tasnim;Rahman, Md Motiur;Kim, Dookie
    • Nuclear Engineering and Technology
    • /
    • 제54권3호
    • /
    • pp.926-939
    • /
    • 2022
  • The area of this study will cover the location-wise seismic response variation of an electrical cabinet in nuclear power point (NPP) based on classical reliability analysis. The location-based seismic ground motion (GM) selection is carried out with the help of probabilistic seismic hazard analysis using PSHRisktool, where the variation of reliability analysis can be understood from the relation between the reliability index and intensity measure. Two different approaches such as the first-order second moment method (FOSM) and Monte Carlo Simulation (MCS) are helped to evaluate and compare the reliability assessment of the cabinet. The cabinet is modeled with material uncertainty utilizing Steel01 as the material model and the fiber section modeling approach is considered to characterize the section's nonlinear reaction behavior. To verify the modal frequency, this study compares the FEM result with recorded data using Least-Squares Complex Exponential (LSCE) method from the impact hammer test. In spite of a few investigations, the main novelty of this study is to introduce the reader to check and compare the seismic reliability assessment variation in different seismic locations and for different earthquake levels. Alongside, the betterment can be found by comparing the result between two considered reliability estimation methods.

원자력발전소 보호시스템 캐비넷의 내진검증 (Seismic Qualification of Plant Protection System Cabinet for Nuclear Power Plant)

  • 정명조;박근배;황원걸
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 1992년도 가을 학술발표회 논문집
    • /
    • pp.148-155
    • /
    • 1992
  • A method to verify seismic qualification of the plant protection system cabinet for a nuclear power plant is presented. A finite element model of the cabinet is developed and correlated to the dynamic properties observed during in-situ vibration test of the actual structure. The results of the modal analysis provide insight into the fundamental dynamic properties of the structure. Techniques for verifying structural integrity and operability are exemplified by summarizing response spectrum and time history analyses of the structure.

  • PDF

원자력발전소 보호시스템 캐비넷의 내진검증 (Seismic Qualification of Plant Protection System Cabinet for Nuclear Power Plant)

  • 정명조;황원걸
    • 전산구조공학
    • /
    • 제6권2호
    • /
    • pp.79-86
    • /
    • 1993
  • 원자력발전소중 안전과 관련된 구조물은 지진의 가능성에 대비하여 그의 구조적 안전성과 가용성이 검증되어야 한다. 본 논문은 원자력발전소 보호시스템 캐비넷을 예를 들어 그에 대한 내진검증 방법을 보였다 캐비넷의 유한요소모델을 작성하여 동특성을 구하였고 그 모우드값을 입력지진스펙트럼과 비교한 결과 구조물의 1차 모우드가 입력 스펙트럼의 peak와 일치함으로써 설계변경의 필요성이 대두되었다. 이 peak값을 피하기 위하여 캐비넷의 구조를 변경하였고 변경된 구조물에 대하여 응답스펙트럼해석과 시간이력해석을 수행하여 구조적 건전성과 가용성을 보임으로써 설계변경된 캐비넷의 내진검증을 확인하였다.

  • PDF

원자로 보호계통 캐비닛의 동해석과 구조 안전성 평가 (Dynamic Analysis and Structural Safety Evaluation of the Cabinet of a Reactor Safety System)

  • 이부윤;조정래;김원진;정동관;손재율
    • 한국정밀공학회지
    • /
    • 제22권12호
    • /
    • pp.131-140
    • /
    • 2005
  • Responses of the cabinet of the reactor safety system under seismic leadings are analyzed, its dynamic characteristics and structural reliability being evaluated. Analyzed natural frequencies are compared with those measured from a resonance test. Structural safety of the cabinet is evaluated in consideration of the required response spectrums of the operation-base and safe-shutdown earthquakes. Transient responses of the cabinet are analyzed with input ground acceleration measured during the seismic test, accelerations being extracted at the locations of the main internal parts. The transient responses are compared with those from the seismic test, favorable results being shown.

지능형 홈 분전반을 이용한 영유아 시설 전기 안전 관리 (A Management of Child Care Facility for Electrical Safety using Home-Smart Cabinet Panel(H-SCP))

  • 안재민;임용배;배석명
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2011년도 제42회 하계학술대회
    • /
    • pp.2144-2145
    • /
    • 2011
  • We carry out a demonstration project to verify performance of a Home- Smart Cabinet Panel(H-SCP) at the child care facility. It is difficult to prevent an electrical disaster using a existing cabinet panel because electrical events are invisible and unforeseeable. So we construct a integrated information system with a Home-Smart Cabinet Panel(H-SCP) for management of low-voltage customers. The integrated information system with the H-SCP maintain the transmitted data from H-SCP, alert a electrical event to a administrator and show a state of customer health in real time respectively. A manager of electrical safety can prevent electrical disaster to maintain electrical facilities after analysis on the integrated information system.

  • PDF