• Title/Summary/Keyword: Cabin Unit

Search Result 23, Processing Time 0.031 seconds

Evaluation of Sound Insulation Performance of a Unit Cabin Mock-up (유니트 캐빈 목업(mock-up)의 차음성능평가)

  • Kim, Hyun-Sil;Kim, Sang-Ryul;Kim, Bong-Ki;Kim, Jae-Seung;Lee, Sung-Hyun
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.48 no.1
    • /
    • pp.49-55
    • /
    • 2011
  • Sound insulation performance of a unit cabin mock-up is studied, where two identical rooms simulating cruise ship cabin are installed. STL (Sound Transmission Loss) measurement in the mock-up shows that STL of the partition between rooms is degraded by imperfect door ceiling and gap between wall and floor. It is also observed that gap around lighting and electrical outlet slightly affect the STL in high frequency ranges, since lighting and electrical outlet are supported by mineral wool in the back side due to fire-resistance requirement. Even after all possible gaps are sealed, STL of the partition is found to be lower than that measured in the laboratory by 9 dB. Measurement of SBN (Structure-Borne Noise) reveals that flanking transmission of SBN along the steel deck floor can severely deteriorate STL of the partition. Statistical energy analysis (SEA) of the mock-up confirms importance of the floor SBN control, in which increasing damping is essential to ensure high STL.

Development of Low-Noise Cooling Fan Using Uneven Fan Blade Spacing (비등간격 블레이드를 이용한 저소음 쿨링팬 개발)

  • Lee, Jeong-Han;Nam, Kyung-Ook
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.11a
    • /
    • pp.1109-1114
    • /
    • 2007
  • When unifying the functions of widely used two-fan, engine cooling system into a single unit, the noise and power issues must be addressed. The noise problem due to the increased fan radius is a serious matter especially as the cabin noise becomes quieter for sedans. Of the fan noise components, discrete noise at BPF's (Blade Passing Frequency) seriously degrades cabin sound quality. Unevenly spaced fan is developed to reduce the tones. The fan blades are spaced such that the center of mass is placed exactly on the fan axis to minimize fan vibration. The resulting fan noise is $3{\sim}11$ dBA quieter in discrete noise level than the even bladed fan.

  • PDF

A Study on communication Protocol of KTX TECA(Terminal Cabin) (KTX 운전자지원 단말기장치 통신프로토콜에 관한 연구)

  • Jung, Sung-Youn;Park, Shin-Ho;Kim, Hyeoung-In;Kim, Chi-Tae;Kang, Ki-Sok;Lee, Byung-Won;Lee, Dong-Soo;Jung, Do-Won
    • Proceedings of the KSR Conference
    • /
    • 2007.05a
    • /
    • pp.1714-1721
    • /
    • 2007
  • TECA (Terminal Cabin), the terminal device which offers the information to the driver about the condition of High Speed Train(KTX), analyzes the system of train and plays a role of corrective maintenance guideline to a driver when a breakdown occurs. It also supports the driver to decide the situation of the train by offering a necessary information, in communicating with MPU(Main Processor Unit). For Localization of TECA, it is necessary to analyze communication protocol between TECA and MPU. As a part of analysis, communication protocol between OBCS(on-board computer system) and add-on devices has analyzed for the first step. Also with protocol analyzer appropriate method was offered for TECA and MPU protocol analysis. Finally, by appling proposed method to the drivers consol suitability was verified.

  • PDF

Development of Air Quality Assessment Model for Subway Cabin (도시철도 객실 공기질 평가모델 개발)

  • Kwon, Soon-Bark;Cho, Young-Min;Park, Duck-Shin;Kim, Se-Young;Park, Jae-Hyung;Cho, Goan-Hyun;Yoo, Gun-Jong;Kim, Jung-Su
    • Proceedings of the KSR Conference
    • /
    • 2010.06a
    • /
    • pp.157-160
    • /
    • 2010
  • Management of indoor air quality of underground subway station is an important issue since the limited natural ventilation, limited sunshine incoming, and highly moistured atmosphere. The improvement in IAQ of platform is expected because most stations were installed with platform screen door currently, however, the poor air quality in tunnel might be affecting subway cabin indoor. In this study, we developed the air quality assessment model based on computational fluid dynamics. The geometry of air ventilation unit, seat, LCD monitors, and passengers were modeled using commercial software (Design Modeler) and fluid pattern and pollutants trajectories were analyzed by using CFX. We predicted the thermal comfort by predicted mean vote (PMV), distribution of CO2 and PM10 concentration. It is expected that this model can be used for the performance test of air cleaners which are under development.

  • PDF

Correlation of $CO_2$ Concentration with Number of Passengers and Tunnel Regions in the KTX Cabin (KTX 객실의 $CO_2$ 농도와 승객 수 및 터널구간과의 상관관계)

  • Kwon, Soon-Bark;Cho, Young-Min;Park, Duck-Shin;Park, Eun-Young
    • Proceedings of the KSR Conference
    • /
    • 2006.11b
    • /
    • pp.192-195
    • /
    • 2006
  • With increasing concerns of indoor air quality, $CO_2$ concentration in the public transportation, such as train, bus, and subway, draws big interests. The $CO_2$ concentration in the indoor air is regarded as index of ventilation status rather than that of adverse health effect. In this study, we measured the time-series of $CO_2$ concentrations in the KTX cabin during the journey of Gyongbu-line (Seoul-Busan) and Honam-line (Seoul-Mokpo) with the number of passengers on board. At the same time, the concentration of particulate matter (PM), temperature, humidity and gaseous pollutants including HCHO and VOCs were monitored. It is found that the $CO_2$ concentration was correlated linearly with number of passengers and was highly correlated with tunnel regions where the ventilation unit (flap) was closed.

  • PDF

A Dynamic Test Facility for Mobile Air Conditioning Systems

  • Gado, Amr;Hwang, Yun-Ho;Radermacher, Reinhard
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.15 no.4
    • /
    • pp.147-155
    • /
    • 2007
  • Mobile air conditioning systems work under widely changing operating conditions. To understand the system behavior under such dynamic conditions, a test facility that can impose transient loads as well as conducting dynamic measurements is needed. To test mobile air conditioning systems including their dynamic performance under various drive cycle patterns without using full scale vehicles in a wind tunnel, a new test facility, called "dynamic simulator," is described. It can replicate real vehicle operating conditions by interacting with the system being tested based on the measured system performance and subsequently adjusting the air properties returning to the test system based on the results of a numerical cabin model. A new dynamic simulator has been designed, constructed, and verified for performing dynamic tests. It was successful in controlling the temperature and relative humidity of the air returning to the test unit within ${\pm}0.7^{\circ}C$ and ${\pm}4%$ of their respective intended values. The verification test under the New European Driving Cycle demonstrated that detailed transient behavior of the mobile air conditioning system could be measured by using this dynamic simulator.

Degradation Behavior of Solder Joint and Implementation Technology for Lead-free Automotive Electronics (자동차 전장제품의 무연솔더 적용기술 및 솔더 접합부 열화거동)

  • Hong, Won Sik;Oh, Chul Min
    • Journal of Welding and Joining
    • /
    • v.31 no.3
    • /
    • pp.22-30
    • /
    • 2013
  • Due to ELV banning, automotive electronics cannot use four kinds of heavy metal element (Pb, Hg, Cd, $Cr^{6+}$) from 2016. Therefore, this study was focused on degradation characteristics of Sn-3.0Ag-0.5Cu Lead-free solder joint with OSP and ENIG finsh under various reliability assessment method, as like to thermal shock test and high temeprature/high humidity test with test duration for cabin electronics. Also, we compared bonding strength degradation to other advanced research results of electronic control unit for engine room because of difference service temperature with mount location in automotive. Whisker growth phenomenon and mitigation method which were essentially consideration items for Pb-free car electronics were examined. Conformal coating is a strong candidate for mitigating whisker growth in automotive electronics. Necessary condition to adapt Pb-free in car electronics was shown.

Research for the Chemical Emergency Oxygen Supply and Lighting System for Aircraft Passengers (항공기 승객용 화학적 비상산소 공급 및 조명시스템에 대한 연구)

  • Kim, Young-In
    • Journal of the Korean Society for Aviation and Aeronautics
    • /
    • v.30 no.2
    • /
    • pp.55-60
    • /
    • 2022
  • A PSU (passenger service unit) is mounted on passenger seats in a cabin on an aircraft and consists of a crew call lamp, a reading lights, an information display lamp, an emergency oxygen generator, and an emergency oxygen mask. It is a safety device for providing convenience to passengers and providing oxygen to passengers in an emergency. This paper is a study on emergency oxygen supply systems and light systems of aircraft PSUs and a control device was developed to operate the system by analyzing the B767-300 aircraft's PSU circuit diagram. And the temperature generated by the B777-200ER aircraft's emergency oxygen generator was also measured by operating it directly. Through this, precautions for explaining the operation of an oxygen mask in an emergency were described and improvements were presented. Data acquired in these research processes can be used in the future to develop aircraft PSU (passenger service unit) and emergency oxygen generators.

Evaluation of Noise Reduction Performance of HVAC System for Ships (선박용 HVAC 시스템의 소음저감성능 평가)

  • Kim, Sang-Ryul;kim, Hyun-Sil;Kim, Jae-Seung;Kim, Bong-Ki;Lee, Sung-Hyun
    • The Journal of the Acoustical Society of Korea
    • /
    • v.29 no.8
    • /
    • pp.497-503
    • /
    • 2010
  • In this paper, evaluation of noise reduction performance of HVAC system for ships by means of HVAC mock-up system is presented. Test is done for six different types of HVAC elements including room unit, silencer, etc. It is found that when diameter of silencer is small and air flow is large, flow noise degrades insertion loss. However, as diameter of silencer becomes larger, the effect of flow noise becomes smaller, and insertion loss up to 25 dB is measured. It is observed that insertion loss of diffuser type room unit is usually between zero and 10 dB, whereas that of the nozzle type room unit can be down to - 15 dB. In addition, it is shown that changing duct arrangement can reduce cabin noise by up to 2 dB, and providing same air flow to each room unit is crucial for generating less noise.