• 제목/요약/키워드: Cabin Unit

검색결과 23건 처리시간 0.021초

유니트 캐빈 목업(mock-up)의 차음성능평가 (Evaluation of Sound Insulation Performance of a Unit Cabin Mock-up)

  • 김현실;김상렬;김봉기;김재승;이성현
    • 대한조선학회논문집
    • /
    • 제48권1호
    • /
    • pp.49-55
    • /
    • 2011
  • Sound insulation performance of a unit cabin mock-up is studied, where two identical rooms simulating cruise ship cabin are installed. STL (Sound Transmission Loss) measurement in the mock-up shows that STL of the partition between rooms is degraded by imperfect door ceiling and gap between wall and floor. It is also observed that gap around lighting and electrical outlet slightly affect the STL in high frequency ranges, since lighting and electrical outlet are supported by mineral wool in the back side due to fire-resistance requirement. Even after all possible gaps are sealed, STL of the partition is found to be lower than that measured in the laboratory by 9 dB. Measurement of SBN (Structure-Borne Noise) reveals that flanking transmission of SBN along the steel deck floor can severely deteriorate STL of the partition. Statistical energy analysis (SEA) of the mock-up confirms importance of the floor SBN control, in which increasing damping is essential to ensure high STL.

비등간격 블레이드를 이용한 저소음 쿨링팬 개발 (Development of Low-Noise Cooling Fan Using Uneven Fan Blade Spacing)

  • 이정한;남경욱
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 추계학술대회논문집
    • /
    • pp.1109-1114
    • /
    • 2007
  • When unifying the functions of widely used two-fan, engine cooling system into a single unit, the noise and power issues must be addressed. The noise problem due to the increased fan radius is a serious matter especially as the cabin noise becomes quieter for sedans. Of the fan noise components, discrete noise at BPF's (Blade Passing Frequency) seriously degrades cabin sound quality. Unevenly spaced fan is developed to reduce the tones. The fan blades are spaced such that the center of mass is placed exactly on the fan axis to minimize fan vibration. The resulting fan noise is $3{\sim}11$ dBA quieter in discrete noise level than the even bladed fan.

  • PDF

KTX 운전자지원 단말기장치 통신프로토콜에 관한 연구 (A Study on communication Protocol of KTX TECA(Terminal Cabin))

  • 정성윤;박신호;김형인;김치태;강기석;이병원;이동수;정도원
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2007년도 춘계학술대회 논문집
    • /
    • pp.1714-1721
    • /
    • 2007
  • TECA (Terminal Cabin), the terminal device which offers the information to the driver about the condition of High Speed Train(KTX), analyzes the system of train and plays a role of corrective maintenance guideline to a driver when a breakdown occurs. It also supports the driver to decide the situation of the train by offering a necessary information, in communicating with MPU(Main Processor Unit). For Localization of TECA, it is necessary to analyze communication protocol between TECA and MPU. As a part of analysis, communication protocol between OBCS(on-board computer system) and add-on devices has analyzed for the first step. Also with protocol analyzer appropriate method was offered for TECA and MPU protocol analysis. Finally, by appling proposed method to the drivers consol suitability was verified.

  • PDF

도시철도 객실 공기질 평가모델 개발 (Development of Air Quality Assessment Model for Subway Cabin)

  • 권순박;조영민;박덕신;김세영;박재형;조관현;유건종;김정수
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2010년도 춘계학술대회 논문집
    • /
    • pp.157-160
    • /
    • 2010
  • Management of indoor air quality of underground subway station is an important issue since the limited natural ventilation, limited sunshine incoming, and highly moistured atmosphere. The improvement in IAQ of platform is expected because most stations were installed with platform screen door currently, however, the poor air quality in tunnel might be affecting subway cabin indoor. In this study, we developed the air quality assessment model based on computational fluid dynamics. The geometry of air ventilation unit, seat, LCD monitors, and passengers were modeled using commercial software (Design Modeler) and fluid pattern and pollutants trajectories were analyzed by using CFX. We predicted the thermal comfort by predicted mean vote (PMV), distribution of CO2 and PM10 concentration. It is expected that this model can be used for the performance test of air cleaners which are under development.

  • PDF

KTX 객실의 $CO_2$ 농도와 승객 수 및 터널구간과의 상관관계 (Correlation of $CO_2$ Concentration with Number of Passengers and Tunnel Regions in the KTX Cabin)

  • 권순박;조영민;박덕신;박은영
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2006년도 추계학술대회 논문집
    • /
    • pp.192-195
    • /
    • 2006
  • With increasing concerns of indoor air quality, $CO_2$ concentration in the public transportation, such as train, bus, and subway, draws big interests. The $CO_2$ concentration in the indoor air is regarded as index of ventilation status rather than that of adverse health effect. In this study, we measured the time-series of $CO_2$ concentrations in the KTX cabin during the journey of Gyongbu-line (Seoul-Busan) and Honam-line (Seoul-Mokpo) with the number of passengers on board. At the same time, the concentration of particulate matter (PM), temperature, humidity and gaseous pollutants including HCHO and VOCs were monitored. It is found that the $CO_2$ concentration was correlated linearly with number of passengers and was highly correlated with tunnel regions where the ventilation unit (flap) was closed.

  • PDF

A Dynamic Test Facility for Mobile Air Conditioning Systems

  • Gado, Amr;Hwang, Yun-Ho;Radermacher, Reinhard
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제15권4호
    • /
    • pp.147-155
    • /
    • 2007
  • Mobile air conditioning systems work under widely changing operating conditions. To understand the system behavior under such dynamic conditions, a test facility that can impose transient loads as well as conducting dynamic measurements is needed. To test mobile air conditioning systems including their dynamic performance under various drive cycle patterns without using full scale vehicles in a wind tunnel, a new test facility, called "dynamic simulator," is described. It can replicate real vehicle operating conditions by interacting with the system being tested based on the measured system performance and subsequently adjusting the air properties returning to the test system based on the results of a numerical cabin model. A new dynamic simulator has been designed, constructed, and verified for performing dynamic tests. It was successful in controlling the temperature and relative humidity of the air returning to the test unit within ${\pm}0.7^{\circ}C$ and ${\pm}4%$ of their respective intended values. The verification test under the New European Driving Cycle demonstrated that detailed transient behavior of the mobile air conditioning system could be measured by using this dynamic simulator.

자동차 전장제품의 무연솔더 적용기술 및 솔더 접합부 열화거동 (Degradation Behavior of Solder Joint and Implementation Technology for Lead-free Automotive Electronics)

  • 홍원식;오철민
    • Journal of Welding and Joining
    • /
    • 제31권3호
    • /
    • pp.22-30
    • /
    • 2013
  • Due to ELV banning, automotive electronics cannot use four kinds of heavy metal element (Pb, Hg, Cd, $Cr^{6+}$) from 2016. Therefore, this study was focused on degradation characteristics of Sn-3.0Ag-0.5Cu Lead-free solder joint with OSP and ENIG finsh under various reliability assessment method, as like to thermal shock test and high temeprature/high humidity test with test duration for cabin electronics. Also, we compared bonding strength degradation to other advanced research results of electronic control unit for engine room because of difference service temperature with mount location in automotive. Whisker growth phenomenon and mitigation method which were essentially consideration items for Pb-free car electronics were examined. Conformal coating is a strong candidate for mitigating whisker growth in automotive electronics. Necessary condition to adapt Pb-free in car electronics was shown.

항공기 승객용 화학적 비상산소 공급 및 조명시스템에 대한 연구 (Research for the Chemical Emergency Oxygen Supply and Lighting System for Aircraft Passengers)

  • 김영인
    • 한국항공운항학회지
    • /
    • 제30권2호
    • /
    • pp.55-60
    • /
    • 2022
  • A PSU (passenger service unit) is mounted on passenger seats in a cabin on an aircraft and consists of a crew call lamp, a reading lights, an information display lamp, an emergency oxygen generator, and an emergency oxygen mask. It is a safety device for providing convenience to passengers and providing oxygen to passengers in an emergency. This paper is a study on emergency oxygen supply systems and light systems of aircraft PSUs and a control device was developed to operate the system by analyzing the B767-300 aircraft's PSU circuit diagram. And the temperature generated by the B777-200ER aircraft's emergency oxygen generator was also measured by operating it directly. Through this, precautions for explaining the operation of an oxygen mask in an emergency were described and improvements were presented. Data acquired in these research processes can be used in the future to develop aircraft PSU (passenger service unit) and emergency oxygen generators.

선박용 HVAC 시스템의 소음저감성능 평가 (Evaluation of Noise Reduction Performance of HVAC System for Ships)

  • 김상렬;김현실;김재승;김봉기;이성현
    • 한국음향학회지
    • /
    • 제29권8호
    • /
    • pp.497-503
    • /
    • 2010
  • 본 논문은 여객선용 HVAC 시스템 목업을 구축하여 HVAC 요소의 성능평가를 수행한 결과를 다루었다. 측정은 룸 유니트 (Room Unit), 소음기 등 6가지 종류에 대해 이루어졌으며 여러 유량에 대해 삽입손실을 측정하였다. 소음기 직경이 작고 유량이 클수록 유동소음이 커져서 소음저감효과를 방해하지만, 직경이 커질수록 유동소음의 효과는 작아지고 삽입손실은 최대 25 dB까지 나타남을 확인하였다. 디퓨저 형태의 룸 유니트는 대체로 삽입손실이 0 - 10 dB 이지만 노즐 형태는 삽입손실이 최대 -15 dB 까지 소음이 커질 수 있음을 확인하였다. 또한 덕트 배열에 따라 최대 2 dB 까지 실내소음이 차이날 수 있음을 보였으며 각 룸 유니트에 동일한 유량이 배출하도록 조절하는 것이 보다 낮은 소음레벨을 얻을 수 있음을 확인하였다.