• 제목/요약/키워드: Cabin Unit

검색결과 23건 처리시간 0.043초

고부가가치선의 Unit Cabin Mock-up 을 이용한 캐빈소음 저감 연구 (Cabin Noise Reduction using Unit Cabin Mock-up of High Value Ship)

  • 주원호;송근복
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2010년도 춘계학술대회 논문집
    • /
    • pp.483-484
    • /
    • 2010
  • Unit cabin means room, which is installed in the high value ship such as drill ship and FPSO, after pre-assembled. In order to develop the noise control design for a unit cabin, a variety of acoustic tests such as sound absorption, transmission, and radiated noise measurements were carried out by using the mock-up of living quarter. From the tests, it was found out that the combined noise level of a unit cabin could be dominated by the radiated noise from wall panel in low frequency range and the design guidelines for the noise control of unit cabin were fully established, such as the improvement of sound transmission loss between the cabin and corridor, and radiated cabin noise reduction.

  • PDF

고부가가치선의 Unit Cabin Mock-up을 이용한 캐빈소음 저감 연구 (Cabin Noise Reduction Using Unit Cabin Mock-up of High Value-added Vessel)

  • 송근복;주원호
    • 한국소음진동공학회논문집
    • /
    • 제20권12호
    • /
    • pp.1210-1215
    • /
    • 2010
  • Unit cabin means room, which is installed in the high value-added vessel such as drill ship, offshore platform and FPSO, after pre-assembled. In order to develop the noise control design for a unit cabin, a variety of acoustic tests such as sound absorption, transmission and radiation measurements were carried out by using the deckhouse mock-up. From the tests, it was found out that the sound transmission loss between cabin and corridor was 13 dB below than FPSO standard and the combined noise level of the unit cabin was dominated by the radiated noise from wall panel in low frequency range. Based on the test results, design guidelines for the noise control of the unit cabin were fully established, such as the improvement of sound transmission loss between the cabin and corridor, and radiated cabin noise reduction.

NORSOK 적용 선박의 Cabin Unit Mock Up 차음성능 계측평가 (Sound Insulation Measurement and Evaluation for Cabin Unit Mock Up in Vessel Satisfying NORSOK Standard)

  • 박진형;박형식;박노준;권혁;서용석;서종수
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2014년도 추계학술대회 논문집
    • /
    • pp.18-19
    • /
    • 2014
  • NORWAY 해역에서 시추 및 생산 작업을 위한 시추선 및 생산 설비의 경우, 엄격한 기준인 NORSOK 기준을 만족해야 한다. NORSOK 기준은 선원들의 안전과 안락성을 위한 Working Environment 만족을 요구하고 있다. 특히 선원들의 거주구역에 안락성은 더욱 중요시되고 소음의 기준을 제시하고 만족을 요구한다. Cabin Unit 이 적용되는 선박의 경우 실선과 동일 조건의 Mock Up 을 제작하여 차음성능 계측 및 평가를 실시한다. 본 논문에서는 NORSOK 이 적용되는 선박의 Cabin Unit 의 Mock Up 차음성능 만족 사례를 소개하고자 한다.

  • PDF

크루즈선 객실의 공조 쾌적성 평가에 관한 연구 (The Study for Evaluation of Thermal Comfort in Passenger Cabin on Cruise Ship)

  • 구근회;이호기;최재웅;이재근
    • 대한조선학회논문집
    • /
    • 제48권1호
    • /
    • pp.62-66
    • /
    • 2011
  • The present work focuses on the evaluation of thermal comfort in passenger cabin of a cruise ship. A computational fluid dynamics (CFD(Airpak)) is used to calculate air velocity and temperature distribution in the passenger cabin as well as PMV and PPD. The CFD is used to simulate two different cases, room unit system and wardrobe duct system. Both of cases are simulated in summer environment condition. The room unit system and wardrobe duct system are compared and evaluated by ISO 7730 thermal comfort categories. The performance of room unit system is shown to be more effective for this typical case of passenger cabin.

전동차 소음저감을 위한 슬라이딩플러그 출입문 개발 (Development of a Sliding-Plug Entrance Door System for Urban Electric Transit Unit to Reduce Inside Noise Level)

  • 서승일;임영호;신동국
    • 한국철도학회논문집
    • /
    • 제5권2호
    • /
    • pp.112-117
    • /
    • 2002
  • Reduction of noise level in the cabin of urban transit unit is an important issue to enhance the comfortability of passengers. It is made clear that a cause of increased noise level in cabin is the imperfect airtightness of entrance doors. In this study, the sliding-plug door system is developed to reduce the noise level of cabins by securing the airtightness of entrance door. The sliding-plug door system is composed of air-driven engine, swing arms, guide rails, guide rollers and locking devices. It is economical owing to using the previous door engine system. It is also adequate for the platform system of our subway station. It was tested to prove the reliability of system and was applied to standard urban transit unit. The effectiveness of noise reduction in cabin resulting form the sliding-plug door system was confirmed by test results.

트랙터 운전실의 소음 저감에 관한 연구 (Noise Reduction in Tractor Cabin)

  • 김원진;은명우
    • 한국생산제조학회지
    • /
    • 제23권4호
    • /
    • pp.380-384
    • /
    • 2014
  • This study focused on identifying the major noise source in a tractor cabin using experimental methods. The noise levels in a tractor cabin for different engine revolution speeds were analyzed to identify the noise source. The results showed that the power steering unit (PSU) was the major noise source in a tractor cabin. The PSU was moved to the outside from the inside of the cabin in order to reduce the noise in the tractor cabin. As a result, the noise levels on the left and right sides of the operator in the tractor cabin were reduced by 6.8 and 3.9 dB, respectively. Finally, the window method was introduced to evaluate the contribution of the transmission noise. The orders of significance in the tractor noise were the front, bottom, and left area, successively.

자동차 엔진룸용 전장품 유무연 솔더 접합부의 열화특성 (Degradation Characteristics of Eutectic and Pb-free Solder Joint of Electronics mounted for Automotive Engine)

  • 김아영;홍원식
    • Journal of Welding and Joining
    • /
    • 제32권3호
    • /
    • pp.74-80
    • /
    • 2014
  • Due to environmental regulations (RoHS, WEEE and ELV) of the European Union, electronics and automotive electronics have to eliminate toxic substance from their devices and system. Especially, reliability issue of lead-free solder joint is increasing in car electronics due to ELV (End-of-Life Vehicle) banning from 2016. We have prepared engine control unit (ECU) modules soldered with Sn-40Pb and Sn-3.0Ag-0.5Cu (SAC305) solders, respectively. Degradation characteristics of solder joint strength were compared with various conditions of automobile environment such as cabin and engine room. Thermal cycle test (TC, $-40^{\circ}C$ ~ ($85^{\circ}C$ and $125^{\circ}C$), 1500 cycles) were conducted with automotive company standard. To compare shear strength degradation rate with eutectic and Pb-free solder alloy, we measured shear strength of chip components and its size from cabin and engine ECU modules. Based on the TC test results, finally, we have known the difference of degradation level with solder alloys and use environmental conditions. Solder joints degradation rate of engine room ECU is superior to cabin ECU due to large CTE (coefficient of thermal expansion) mismatch in field condition. Degradation rate of engine room ECU is 50~60% larger than cabin room electronics.

주차환기 시스템이 차 실내 열부하에 미치는 영향에 관한 연구 (Study of Pre-ventilation Effects on the Cabin Thermal Load)

  • 이대웅
    • 한국자동차공학회논문집
    • /
    • 제22권5호
    • /
    • pp.84-90
    • /
    • 2014
  • The aim of this paper is to investigate the application of solar energy in reducing cabin thermal load. When a vehicle is parked under the sun in summer, the interior temperature can reach up to $70^{\circ}C$ depending on the solar intensity. Solar power, one of the green energies, is used in automobile air conditioning systems, in order to operate the blower. The power supply of a blower's voltage has been used in a solar sunroof experiment. At the climate wind tunnel, cabin temperature changes were conducted with various operating modes of an air handling system and the preventilation parking conditions of several vehicles, outdoors, was also examined. The test results of the solar sunroof, 39.3W power and 14.1% efficiency were obtained. The thermal load behavior was analysed with the air handling system operating mode differently according to the cabin temperature. By simply operating the blower, average cabin temperature decreased between $5^{\circ}C{\sim}10^{\circ}C$ in those vehicles parked outdoors in summer. This reveals that cabin thermal comfort can be improved without consuming the vehicle's extra energy, and that the performance of the air-conditioning system is better than those currently found in vehicles. Moreover, fuel economy will be increased as a result of the reduction in the use of the air-conditioning system, and many other human advantages will be gained. Such advantages include minimized VOCs and a healthy cabin environment.

전동차의 중련연결시 TCMS장치의 데이터 통신에 관한 네트워크 구현 (The Network Implementation on Data Communication of TCMS in case of multiple configuration of EMU(Electric Multiple Unit))

  • 서상준;한정수;최종묵
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2005년도 춘계학술대회 논문집
    • /
    • pp.744-749
    • /
    • 2005
  • The train configuration is based on one unit like basic 4 cars to multiple unit operation. Each unit has unique node such as train formation number. Some equipments(TC, CC) of TCMS are connected to the master TC through the LonWorks network. When the train is consist of multiple unit, TCMS has to implement quick network for data communication overall train. But a variable time delay is generated when it is performed communication with point to point type using train formation number. In this paper we propose new method to know the node information of adjacent unit. that is to add digital input signals notifying cab direction at any cabin. Also, we provide the optimized screen design that all collected information via network is displayed by each unit.

  • PDF