• Title/Summary/Keyword: CW

Search Result 986, Processing Time 0.029 seconds

Artificial Intelligence-Based CW Radar Signal Processing Method for Improving Non-contact Heart Rate Measurement (비접촉형 심박수 측정 정확도 향상을 위한 인공지능 기반 CW 레이더 신호처리)

  • Won Yeol Yoon;Nam Kyu Kwon
    • IEMEK Journal of Embedded Systems and Applications
    • /
    • v.18 no.6
    • /
    • pp.277-283
    • /
    • 2023
  • Vital signals provide essential information regarding the health status of individuals, thereby contributing to health management and medical research. Present monitoring methods, such as ECGs (Electrocardiograms) and smartwatches, demand proximity and fixed postures, which limit their applicability. To address this, Non-contact vital signal measurement methods, such as CW (Continuous-Wave) radar, have emerged as a solution. However, unwanted signal components and a stepwise processing approach lead to errors and limitations in heart rate detection. To overcome these issues, this study introduces an integrated neural network approach that combines noise removal, demodulation, and dominant-frequency detection into a unified process. The neural network employed for signal processing in this research adopts a MLP (Multi-Layer Perceptron) architecture, which analyzes the in-phase and quadrature signals collected within a specified time window, using two distinct input layers. The training of the neural network utilizes CW radar signals and reference heart rates obtained from the ECG. In the experimental evaluation, networks trained on different datasets were compared, and their performance was assessed based on loss and frequency accuracy. The proposed methodology exhibits substantial potential for achieving precise vital signals through non-contact measurements, effectively mitigating the limitations of existing methodologies.

SEMIALGEBRAIC G CW COMPLEX STRUCTURE OF SEMIALGEBRAIC G SPACES

  • Park, Dae-Heui;Suh, Dong-Youp
    • Journal of the Korean Mathematical Society
    • /
    • v.35 no.2
    • /
    • pp.371-386
    • /
    • 1998
  • Let G be a compact Lie group and M a semialgebraic G space in some orthogonal representation space of G. We prove that if G is finite then M has an equivariant semialgebraic triangulation. Moreover this triangulation is unique. When G is not finite we show that M has a semialgebraic G CW complex structure, and this structure is unique. As a consequence compact semialgebraic G space has an equivariant simple homotopy type.

  • PDF

A $LN_2$-cooled, Broadband cw CO Laser (액체질소 냉각형광대역 cw CO 레이저)

  • Kim, Y.P.;Choi, J.W.;Won, J.W.
    • Proceedings of the KIEE Conference
    • /
    • 1989.07a
    • /
    • pp.667-671
    • /
    • 1989
  • The CO laser is one of powerful light source for laser magnetic resonance spectroscopy in the mid-infrared region of the spectrum because of its wideband operational characteristics. In this work, a liquid nitrogen cooled cw CO laser is developed to allow broad-band operation from 5 to 8 ${\mu}m$. The design details will be presented.

  • PDF

A Study on the Tank Monitoring System Using FM-CW (FM-CW파를 이용한 탱크 모니터링 시스템에 관한 연구)

  • 강동균;박규식;김동일
    • Journal of the Korean Institute of Navigation
    • /
    • v.19 no.2
    • /
    • pp.115-120
    • /
    • 1995
  • Recently, the ship automation technology(SAT) has received great attention for the efficient management of the ship with minimum human efforts. Among the SAT, a distance measuring system, the key element is the signal processing unit for the interpretion of the received signal from the remote sensing of the oil tank. In this paper, the tank monitoring system using FM-CW is described for the oil tank level guage measurement with an emphsis of signal processing unit.

  • PDF

A Study on the Development of CW(Continuous-Wave)Doppler System for measuring Bi-directional Blood Flow Information (혈류 방향을 구별하는 연속 초음파 도플러 장치에 관한 연구)

  • 강충신;김영길
    • Journal of Biomedical Engineering Research
    • /
    • v.8 no.1
    • /
    • pp.75-80
    • /
    • 1987
  • With the conventional CW Doppler velocity meter, bl-directional velocities cannot be separated. The new CW Doppler system uses quadrature detection and phase rotation to produce simultaneous independent audio and velocity signals for forward and reverse blood flow direction, is fabricated. Specially, this system shows that phase rotation method for flow direction separation provides easy and satisfactory feature. From in vivo blood flow measurement, we can easily differentiate typical artery flow from vein flow, and measure both velocity characteristics qualitatively.

  • PDF

The theoretical analysis of characteristics for temperatures in cw $CO_{2}$ laser (CW $CO_{2}$ 레이저의 온도 특성에 관한 해석)

  • Kang, Dong-Heon;Park, Deug-Il;Lee, Choo-Hie
    • Proceedings of the KIEE Conference
    • /
    • 1988.07a
    • /
    • pp.465-468
    • /
    • 1988
  • The output power is dependent of the vibrational level temperatures and wall temperature of the discharge tube in cw $CO_{2}$ lasers. The method postulates the introduction of a vibrational temperatures Ti for each vibrational mode. The vibrational and wall temperature are dertermined by the equations of the vibrational energy balance and thermal conductivity.

  • PDF

Benign convulsion with mild gastroenteritis

  • Kang, Ben;Kwon, Young Se
    • Clinical and Experimental Pediatrics
    • /
    • v.57 no.7
    • /
    • pp.304-309
    • /
    • 2014
  • Benign convulsion with mild gastroenteritis (CwG) is a type of afebrile seizure that occurs in children. CwG is defined as a convulsion in a previously healthy child with no known central nervous system infection or encephalopathy, accompanying mild diarrhea without fever, electrolyte imbalance, or moderate to severe dehydration. Convulsions in CwG are characterized by multiple brief episodes of generalized or focal seizures. Although the etiology and pathophysiology have yet to be fully explained, many pathogenic mechanisms have been proposed including the possibility of direct invasion of the central nervous system by a gastrointestinal virus such as rotavirus or the possibility of indirect influence by the production and effects of certain mediators. The electroencephalogram findings are benign and long-term antiepileptic treatment is typically not required. Long-term prognosis has been favorable with normal psychomotor development. This review provides a general overview of CwG with the goal of allowing physicians practicing in the field of pediatrics to better recognize this unique entity and, ultimately, to minimize unnecessary evaluation and treatment.

Welding Characteristics of SCP1 on CW Nd:Yag Laser (CW Nd:YAG 레이저에 의한 SCP1의 용접특성)

  • Shin, Byung-Heon;Yoo, Young-Tae;Shin, Ho-Jun;Yun, Chul-Jung
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.24 no.5
    • /
    • pp.35-43
    • /
    • 2007
  • Laser welding of metals has been widely used to improve a wear resistance and a corrosion resistance of the industrial parts. The objective of this research works is to investigate the influence of the process parameters, such as the welding for metals with CW Nd:YAG lasers. The bead-on-plate welding tests are carried out for several combinations of the experimental conditions. In order to quantitatively examine the characteristics of the butt welding, the welding quality of the cut section, stain-stress behavior and the hardness of the welded part are investigated. From the results of the investigation, it has been shown that the optimal welding condition without defects in the vicinity of the welded area and with a good welding quality is 1325W of the laser power, and 1.4m/min of laser welding speed.

Precise Measurement of Magnetic Field Using CW-NMR Technique (CW-NMR 기법을 이용한 자기장 정밀측정)

  • 이정한;이대행;김민철;이순칠;홍계원;이호준
    • Journal of the Korean Magnetics Society
    • /
    • v.5 no.1
    • /
    • pp.79-85
    • /
    • 1995
  • A precise magnetic field probe was designed to measure the field distribution inside a superconducting magnet. The operation principle of the developed equipment is based on cw-NMR. The range of field is from 2.8 T to 5.8 T, and the resolution is better than 0.3 ppm NMR samples were water and heavy water contained in a tube of 4 mm diameter and 4mm height. This equipment can be manufactured very inexpensively compared with the currently available commertial ones.

  • PDF